Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.3 LAdmitted-Finance | -37.99% | ₹8.3 L | L1 | Admitted-Finance |
| 2 | L2₹8.6 LAdmitted-Finance | -36.10% | ₹8.6 L | L2 | Admitted-Finance |
| 3 | L3₹8.8 LAdmitted-Finance | -34.50% | ₹8.8 L | L3 | Admitted-Finance |
| 4 | L4₹10.4 LAdmitted-Finance | -22.50% | ₹10.4 L | L4 | Admitted-Finance |
| 5 | L5₹11.5 LAdmitted-Finance | -14.14% | ₹11.5 L | L5 | Admitted-Finance |
Tender Value
₹13.4 L
EMD Value
₹26,793
Closing Date
27 Jan 2026, 3:00 pmClosed
Executive Engineer (E)
O/o EE/ELD-8/DDA, 21st floor Vikas Minar.
Sh-Running, maintenance and operation of internal electrical installation, compound lighting i/c replacement of panel and IEI work etc at Community Hall (near Sainik Vihar and Rishi Nagar) Rani Bagh, Pitampura and community hall Shastri nagar.
2026_DDA_894769_1
32/EE/ELD-8/DDA/2025-26
Open Tender
Electrical Works
180 days
Vikas Minar
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹26,793
4 Feb 2026
20 Jan 2026
28 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
Maintenance, cleaning and testing of electrical & mechanical IEI installations on weekly basis such as compound lighting and internal electrical installations as per terms & conditions and inventory enclosed by deplolying following staff. A)1 no.wireman and 1 No.khallasi-2 days in a week in general shift and as and when required for Community Hall (near Sainik Vihar & Rishi Nagar) Rani Bagh, Pitampura and community hall Shastri nagar.
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Rewinding of existing damaged/burnt out ceilling fan of 1200 sweep size in all respect i/c dismantling the existing fan and refixing the same with connection, testing etc complete as required.
Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying and replacement of 3.15 MFD capacitor suitable for 1200mm sweep ceilling fan i/c testing,connection etc required.
Supply and fixing of following electrical wiring from deputed labour accessories i/c connection, testing etc complete as required.
3 mm thick phenolic laminated sheet
5/6 amp one way switch piano type ISI marked
15/16 amp one way switch piano type ISI marked
3 pin 5/6 amp socket outlet piano type ISI marked
6 pin 15/16 A & 5/6A socket outlet Piano type ISI marked
Supplying and drawing of FRLS/HFFR PVC insulated single core copper condutor cable in the existing surface/receses, steel/PVC conduit
1.5 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable
2.5 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable
4 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable
10 sq. mm ISI marked,FRLS/HFFR PVC insulated single core copper condutor cable
Supplying and Replacement of 450 mm sweep size Heavy duty metallic exhaust fan with 1400r/min sweep complete in all respect with louvers suitable for single phase 230 volt,50 Hz AC supply i/c connection, testing etc. complete as reqd.
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150watt
Supplying and fixing of 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete i/c with connections, testing and commissioning etc. as required
Single pole
Double Pole
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders with suitable cubicle panel board type sheet enclousure including drilling holes in cubicle panel/wall surface, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 630 A,50KA,FPMCCB
Supply of FRLS XLPE power cable of 1.1 kV grade aluminium conductor armoured cable of the followng sizes complete as requireda)3.5 core 400 sq.mm
b) 3.5 Core 300 Sq. mm
c) 4 Core 50 Sq. mm
Laying and fixing of one number FRLS PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.a) Above 35 sq. mm and upto 95 sq. mm(clamped with 25x3mm MS flat clamp)
b) Above 185 sq. mm and upto 400 sq. mm(clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a)3½ X 400 sq. mm
b) 3½ X 300 sq. mm
c)4 X 50 sq. mm
Supplying and Installation of following size of Perforated painted with powder coating M.S Cable Trays with perforation not more than 17.5%, in convenient section, joined with connector, suspended from the ceiling with M.S. suspenders including bolts & nuts, paiting suspenders etc as requireda) 100 mm width X 50 mm depth X 1.6 mm thickness
b) 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and Installation of following size of Perforated painted with powder coating M.S Cable Trays bends with perforation not more than 17.5%, in convenient section, joined with connector, suspended from the ceiling with M.S. suspenders including bolts & nuts, paiting suspenders etc as requireda) 100 mm width X 50 mm depth X 1.6 mm thickness
b) 300 mm width X 50 mm depth X 1.6 mm thickness
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.50 MB
BOQ_940488.xls
BOQ • 0.33 MB
TenderDoc32.pdf
Tender Documents • 2.52 MB
Download all tender documents and submit your bid