| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹9.9 L+₹2.8 L (39.2%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹10.2 L+₹3.1 L (42.8%)Rejected-Finance D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | L3 | Rejected-Finance Being Not L1 | |
| 4 | Rejected-Technical MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | - | Rejected-Technical Not enlisted in requisite category | |
| 5 | Rejected-Technical 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
13 Jan 2023, 6:00 pmClosed
Shri Nitesh K Singh, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8442 CERTAIN REPAIRS TO GOODS/PASSENGER LIFTS AT VARIOUS BLDGS INCLUDING LOAD TESTING IN NSTL TECHNICAL AREA UNDER AGE(I) R n D NSTL VISAKHAPATNAM
2022_MES_570659_1
AGE I R AND D NSTL VIZAG 8442
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class E Category c(ii)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹19,000
Yes
20 Jan 2023
22 Dec 2022
16 Jan 2023
22 Dec 2022
13 Jan 2023
30 Dec 2022
Amount
Supply install, testing and commssioning of Automatic Rescue Device(ARD) of Micro processor based, VVVF for power control for passenger lift of capacity 1000kg make: Johnson along with maintance free batteries for backup (sealed type) and with controllers, battery charging circuit unit/circuit, invertor circuits with transformer for break door control to be incorporated all indicators like battery charging rescue operations ON, Lift Moving UP , Lift Moving Down, safety controll complete by removing the unserviceable old ARD Panel complete all as specified and directed. Make:JELTRON/Toshiba/Yasakawa for ARD Make:AMCO/EXIDE for Batteries
Supply install, testing and commssioning in repairs of Car operating Panel made out of stainless steel 304 grade 1.5mm thick hairline finish by removing the underviceable old panel complete all as specified and directed.
Supply install, testing and commssioning in repairs of Landing operating Panel G+3 by removing the unserviceable old panel complete all as specified and directed.
Supply install, testing and commssioning in repairs of Over speed Governer Mechanism inclusive of top & bottom pully's with rope by removing the unserviceable old panel complete all as specified and directed.
Repair/replacement of Lift cabin Fan 35W/230V 50 Hz
Repair/replacement of Lift cabin Light fittings (5W LED) Make: Philips/Havells/CG
S&F in replacement of emergency lights with chargeable battery 230V
S&F in replacement of 800 central opening G+3 Auto door sensor
Repair/replacement of Lift break mechanism for 1000Kg Johnson Lift
S&F in replacement of 800 central opening G+3 Break Liners
Repair/replacement of Auto door fermator drive 1000 Kg Johnson Lift
Material and labour for carryong out Load test to the following Passenger and Goods Lift in various technical buildings along with checking all the mechanical, electrical, safety, spped locks, conditional interlocks, load/strain and light sensors for complait free operation of the lifts including testing for the operation of ARD complete and directed by the Engr in charge all as spacified and as directed by the Engr - in- Charge. (a) Passenger lift 1000 Kg capacity of make Johnson in P-4 Bldg A block
(b) Passenger Lift ( 680 Kg ) of make Johnson in HR Wing G + 4 Floors. The rates quoted by the tenderers shall deemed to be including cost of ARTIFICIAL Loads and other safety items as required during testing
Supply only 10 to 12% W/W concentrated sodium hypochlorate liquid as per IS-11673 Grade-II in sealed container for traetment of drinking water all as specified and directed by Engr-In-Charge. Make: Decrin/ Declibac/ Rmco
Supply and Fix 150 watt very high efficient round highbay Lihgt in PDC housing suitable for industrial application. The luminaire has efficacy upto 130Lm/W with ingress protection of IP66 with additional safety chain. Model: Crompton LHB11-150-CDL/60-HPM or equilant in Havells/Phillips/Bajaj
MONITOR ENGINEERING WORKS
INDUSTRIAL ENGINEERING SYSTEMS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .