| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest-1 | |
| 2 | L-2₹25.7 L+₹65,451.49 (2.61%)Rejected-Finance H NO 29 1 3 PALACE COLONY MANDI DISTT MANDI H P | MANDI | HIMACHAL PRADESH | 175001 | L-2 | Rejected-Finance Lowest-2 |
Tender Value
Refer Docs
EMD Value
₹34,100
Closing Date
7 Jul 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
EXECUTIVE ENGINEER JAL SHAKTI DIVISION BAGGI
AS PER BOQ
2021_HPIPH_49183_1
EE-JSD-BAGGI/2021- 8198-8248 DATED 28/06/2021
Open Tender
Civil Works
Item Rate
90 days
BAGGI
AS PER NIT
6 documents required · 6 mandatory
₹400
EE BAGGI
₹34,100
Yes
27 Dec 2022
29 Jun 2021
8 Jul 2021
29 Jun 2021
7 Jul 2021
29 Jun 2021
120 days
Amount
Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Metres stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition complete in all respects with in all leads & lifts as per the entire satisfaction & directions of Engineer- in- charge.
Providing and laying cement concrete 1:3:6 (1 cement:3sand:6 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work in foundation and plinth within all leads and lifts in all leads and lifts as per the direction and satisfaction of Engineer-in-charge.
Providing and laying Reinforced cement concrete work 1:1.5:3 (1cement: 1.5 sand : 3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:
Foundations,footings bases of columns and the like and mass concrete
Walls ( any thickness but not less than 0.10m thicknes) including attached butteresses, pillaster plinth and string courses etc. from top of foundation level upto floor two level complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge. Floor two level to floor three level, Floor three level to floor four level
Floor four level to floor five level
Columns, pillars posts and struts upto floor two level
Floor two level to floor three level
Floor three level to floor four level
Lintels, beams girders bressumers and cantilevers upto floor two level ,floor three level
Floor two level to floor three level
Floor three level to floor four level
Arches upto floor two level
Floor two level to floor three level
Floor three level to floor four level
Suspended Floor roofs, landing and shelves and their support balconies,beams, girders, bressumers and contilever upto floor two level :- Floor two level Floor three level
Floor three level to floor four level
Providing form work with steel plates 3.15 mm thick welded with angles iron in frame 30 x 30 x 5 mm so as to give a fair finish including centering shuttering struting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for in-situ- reinforced concrete and plain concrete in complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Foundation, footing, basis of columns & the like and mass concrete complete in all respect within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like.
Vertical surface such as wall (any thickness) partition and the like including attached pillasters, butresses, etc. plinth and string course up to 4.00Mtrs . complete job in all respects with in all leads and lifts as per the direction and best satisfaction of Engineer-in-charge. Upto 4.00 mtr
Beyond 4.00mtr to 17.85 Mtrs
Columns, pillars posts and struts upto floor two level:
circular in plan up to 4 mtr height
Beyond 4.00 mtr to 15 mtrs.
Beams canitliver girders lintels bressumers and cantilevers
Providing from work of ordinary timber plankings so as to give a rough finish including centring,shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceililng not exceeding 4 metres and removal of the same for insitu reinforced concrete and plain concrete work in:- two level in arches complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Beyond 4.00 mtr to 12 mtrs.
Beyond 10.00 mtr to 12.50 mtrs.
Providing Mild steel /Tor steel reinforcement for RCC work including bending, binding and placing in position complete in all respect within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces(two coats)to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered material etc.complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Providing and Fixing SFRC Man hole cover of 500mm (MC) dia with frame as per relevant codes and specifications complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge.
Laying, jointing and testing in trenches to be levelled, to grades, GI flanged pipes of following diameter and MS Flanges of Table-17 ( Part-II) having minimum wall thickness and class of pipes specified below, provided and jointed with MS flanges confirming to tables as specified below of BIS 6392-1971, excluding the cost of execavation in trenches complete in all respect , welded at both ends according to relevant BIS standards and detailed specifications complete, with nut & bolts of required sizes, 3mm thick compressed asbestos fiber jointing gasket or synthetic rubber gasket confirming to relevant BIS codes, including all kinds of flanged short pieces, bends, tees & other specials etc made from parent tubes & provided and welded with flanges of tables as applicable for the particular reach as per site conditions, including flushing,cleaning & hydraulic testing of pipe as per directions of Engineer-in-charge. (GI Pipes will be supplied by the department free of cost).
150 mm for Scour pipe
100 mm for Inlet/over flow/outlet pipe
Steel work welded built up section section including cutting, hoisting and fixing in position and applying a priming coat of red lead paint: In grating framed guard bar ladders, railing brakcet and similar work complete as per direction of the Engineer-in-charge in all leads and lifts.
Laying, jointing and testing of GI pipes (Light Class) of following diameter screwed and socketted pipes, including GI fittings in all leads and lifts as per the directions and satisfaction of Engineer-in-charge, (Earth work in trenches to be measured and paid for seperatly):- complete within all leads and lifts as per the direction and satisfaction of Engineer-in-Charge. 25mm dia
Providing & fixing of Cast iron sluice valve (with hand wheel)as per IS 780 class-I upto 150 mm dia including brass spindle and as per IS 2906 class- II for diameters more than 150 mm complete with nuts and bolts and gasket confirming to relevent codes and specifications including complete process of fixing of valve complete in all respect with in all leads & lifts as per the entire satisfaction of the Engineer-in-charge.
150 mm for Scour pipe
100 mm for Inlet/over flow/outlet pipe
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 Cement : 3 Sand : 6 Graded stone aggregated 20mm nominal size) within all leads and lifts in all leads and lifts as per the direction and satisfaction of Engineer-in-charge.
Constructing chamber for sluice valve with CI surface box 100mm top dia 160mm bottom dia & 180mm deep ( inside) with chainded lid RCC top 1:2:4 (1 cement: 2 sand:4 graded stone aggregate 20mm nominal size) 100mm thick foundation concerte and curing 1:5:10 mix (1 cement:5sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortor 1:3 ( 1cement : 3sand) finsihed with a foating coat of neat cement complete including curring complete 600x600x750mm inside size with 150mm thick wall of RCC 1:2:4 (1 cement:2sand:4 graded stone aggregate 20mm nominal size) complete with form work and reinforcement with 6mm bars at not exceeding 150mm centre both wages within in all leads and lifts as per the direction and satisfaction of Engineer-in-charge.
Providing ansd fixing of below items required for OHSR complete within all leads and lifts in all leads and lifts as per the direction and satisfaction of Engineer-in-charge.
Lighting conductor
Water measurement gague
Provision vetilation complete
Flanged bell mouth alon with puddle collars
Expansion joints
Structural design & drawing
Soil testing repor for bearing of soil
V S CONTRACTORS AND ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .