Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC CHAKKALAKKAL H KOTTAT P O | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.1 L+₹9,945 (1.11%)Rejected-Finance FIRST FLOOR DOOR NO 3 BQ COMPLEX OPP GRAMAPANCHAYAT MALAYINKEEZHU P O THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695571 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical AROOR P O ALAPPUZHA KERALA 688534 | ALAPPUZHA | ALAPPUZHA | KERALA | 688534 | - | Rejected-Technical L3 |
Tender Value
₹10.8 L
EMD Value
₹26,940
Closing Date
8 Apr 2025, 4:00 pmClosed
Executive Engineer Thrissur corporation
Executive Engineer Thrissur corporation
Thrissur Corporation vilvattom Zonal Division 11 Gandhinagar Minimast Light in Various Places -Project no S2072/25-General Electrical Work
2025_LSGD_757313_23
PW2-17409/18,10.04.25EE2
Open Tender
Electrical Works
Item Rate
180 days
Superintending Engineer Thrissur corporation
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
₹26,940
14 Jul 2025
31 Mar 2025
10 Apr 2025
31 Mar 2025
8 Apr 2025
31 Mar 2025
31 Mar 2025 - 4 Apr 2025
Amount
Mini mast lights
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD545456/2024-2025:Supply and providing tor steel rod for reinforced cement concrete including cutting bending and tying in shape as required.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
OD545448/2024-2025:Supply and fitting in the existing Control panel 24 hours Analog Timer switch supply voltage 230 V 50 Hz for operating automatic on/off function with IP53 grade protection, operating temperature 10 º C - 50º C, contact>16 A for controlling -main contactor-1 Nos and giving connections etc complete.
OD545454/2024-2025:Supply and providing 220V,16A , 2 Pole , contactor for mini mast lighting and giving connections etc as required.(L&T MU 2P or equivalent make)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD545447/2024-2025:Providing independent Ordinary pipe earthing using 2.5 meters of 40 mm dia GI pipe ,earth wire copper and other specials such as common salt ,charcoal bolts and nuts etc. complete required at site.
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD545453/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing MS box/earth bus etc. as required including necessary holes as required. 12x3mm brass nut and bolt
OD545455/2024-2025:Supply and providing the following sizes of bolt and nut with washers on the existing MS box/earth bus etc. as required including necessary holes as required. 25x3mm brass nut and bol
OD545452/2024-2025:Supply and providing 32 A Neutral link mounted on DMC/SMC base, in the meter box and giving connections as required
OD545446/2024-2025:Supplying and fixing of meter box weather proof type (make Sintex IP 67) of size 540x320x200 mm with 2 compartment, for providing single phase energy meter, fuse unit, Isolator, RCCB, Analog Timer. Meter box fixing on the pole using suitable clamps with bolts and nuts etc complete.
OD545450/2024-2025:Supply and providing 32 A HRC fuse unit with HRC fuse link i the meter box and giving connections as required
OD545449/2024-2025:Preparing completion and test certificates for KSEB connection
BOSS LIGHT (BID ID -2189523)
KELTRON LIGHTING DIVISION (BID ID -2186868)
Bidder Name
BIJU JOSE
BOSS LIGHT
KELTRON LIGHTING DIVISION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1230439.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .