| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹51.5 LAccepted-AOC NO 121 6 SATHANUR MAIN ROAD SATHANUR BANGALORE KARNATAKA 560064 | BENGALURU URBAN | KARNATAKA | 560064 | ₹51.5 L | 1 | Accepted-AOC L1 |
| 2 | 2₹55.0 L+₹3.4 L (6.65%)Rejected-Finance 41 1948 1ST FLOOR CITY MEMORIAL BUILDING T A BEERANKUNJU ROAD ERNAKULAM KERALA INDIA 682018 ERNAKULAM CITY | ERNAKULAM | KERALA | 682018 | ₹55.0 L+₹3.4 L (6.65%) | 2 | Rejected-Finance 2 |
| 3 | 3₹63.9 L+₹12.4 L (24.0%)Rejected-Finance TC 5 140 9 RAGA HEIGHTS PIPELINE ROAD RAVI NAGAR PEROORKKADA P O TRIVANDRUM KERALA 695005 | THIRUVANANTHAPURAM | KERALA | 695005 | ₹63.9 L+₹12.4 L (24.0%) | 3 | Rejected-Finance 3 |
| 4 | 4₹65.5 L+₹14.0 L (27.1%)Rejected-Finance | ₹65.5 L+₹14.0 L (27.1%) | 4 | Rejected-Finance 4 |
| 5 | Not Admitted-Finance | - | - | Not Admitted-Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | Techpool Consultancy Services Pvt Ltd | Perpetual Power Services Pvt Ltd | METRO POWER | HYKON INDIA LIMITED |
|---|---|---|---|---|---|---|---|
| 1.00SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 6 KVA ONLINE UPS WITH BATTERY BANK FOR SDPK CENTRES UNDER VIJNANA KERALAM INITIATIVE | |||||||
| 1.01 | UPS:
• UPS Type: Online Double Conversion
• Capacity: 6 kVA / Minimum 4.8 kW
• Input Voltage Range: 160V – 300V AC
• Input Frequency: 50 Hz ±5%
• Output Voltage: 230V AC ±1%
• Output Frequency: 50 Hz ±0.1%
• Output Power Factor: ≥ 0.8
• Efficiency: ≥ 90% at full load
• LCD / LED showing input/output voltage, load %, battery status, alarms
• Protection : Overload protection, Short Circuit protection, Over/under Voltage protection and Battery deep discharge protection
• Cooling: Forced air cooling
• Form Factor : Tower/Industrial grade | 23 | Nos | 22,16,097.61 ₹22,16,097.61 | 12,21,300 ₹12,21,300 Lowest | 22,16,096 ₹22,16,096 | 13,57,589.03 ₹13,57,589.03 |
| 1.02 | Battery Specifications:
• Battery Type: Sealed Maintenance Free (SMF), VRLA
• Rating: 12V, 65Ah
• Technology: AGM / VRLA
• Battery Quantity – Minimum 12 Nos(Must support 5- 7 hours backup for the specified SDPK Lab Load)
• Backup Time – Minimum 5 hours preferably up to 7 hours
• Battery Rack : Heavy Duty power coated metal rack, proper ventilation and safety arrangement
• Battery manufacturing date less than 6 months from date of supply | 276 | Nos | 67,58,185.68 ₹67,58,185.68 | 54,71,424 ₹54,71,424 Lowest | 63,82,224 ₹63,82,224 | 64,96,432.8 ₹64,96,432.8 |
| 1.03 | Cabling & Accessories
• Battery interconnecting cables with Lugs
• Input and output power cables
• Battery protection using MCB/Fuse
• Earthling provision for UPS and battery bank | 23 | Nos | 46,000 ₹46,000 Lowest | 4,15,242 ₹4,15,242 | 69,000 ₹69,000 | 78,895.52 ₹78,895.52 |
Tender Value
₹54.3 L
EMD Value
₹54,280
Closing Date
10 Feb 2026, 3:30 pmClosed
Member Secretary
India Heights Govt Womens College Road Vazhuthacaud Thiruvananthapuram 695014
Supply, Installation, Testing and Commissioning of 6 kVA Online UPS With Battery Bank for 23 SDPK Centres
2026_KDIC_831512_1
KDISC/SDPK/4364/2025/03
Open Tender
Hardware
Supply and Service
14 days
23 SDPK Centres
As per Tender Document
2 documents required · 2 mandatory
₹29,500
Yes
₹54,280
Yes
K-DISC HQ Vazhuthacaud
18 Jun 2026
28 Jan 2026
11 Feb 2026
28 Jan 2026
10 Feb 2026
28 Jan 2026
28 Jan 2026 - 4 Feb 2026
5 Feb 2026
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 6 KVA ONLINE UPS WITH BATTERY BANK FOR SDPK CENTRES UNDER VIJNANA KERALAM INITIATIVE
UPS: • UPS Type: Online Double Conversion • Capacity: 6 kVA / Minimum 4.8 kW • Input Voltage Range: 160V – 300V AC • Input Frequency: 50 Hz ±5% • Output Voltage: 230V AC ±1% • Output Frequency: 50 Hz ±0.1% • Output Power Factor: ≥ 0.8 • Efficiency: ≥ 90% at full load • LCD / LED showing input/output voltage, load %, battery status, alarms • Protection : Overload protection, Short Circuit protection, Over/under Voltage protection and Battery deep discharge protection • Cooling: Forced air cooling • Form Factor : Tower/Industrial grade
Battery Specifications: • Battery Type: Sealed Maintenance Free (SMF), VRLA • Rating: 12V, 65Ah • Technology: AGM / VRLA • Battery Quantity – Minimum 12 Nos(Must support 5- 7 hours backup for the specified SDPK Lab Load) • Backup Time – Minimum 5 hours preferably up to 7 hours • Battery Rack : Heavy Duty power coated metal rack, proper ventilation and safety arrangement • Battery manufacturing date less than 6 months from date of supply
Cabling & Accessories • Battery interconnecting cables with Lugs • Input and output power cables • Battery protection using MCB/Fuse • Earthling provision for UPS and battery bank
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
SDPKUPS.pdf
Tender Documents • 1.04 MB
BOQ_1397141.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .