Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC E76 LGF KALKAJI BHAIRAV MANDIR NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L1 | Accepted-AOC Selected | |
| 2 | L2₹24.1 L+₹2.1 L (9.47%)Rejected-AOC 1853 2ND FLOOR SURYA BAZAAR BHAGIRATH PLACE DELHI 06 | NORTH | DELHI | 110006 | L2 | Rejected-AOC Selected | |
| 3 | L3₹26.8 L+₹4.9 L (22.1%)Rejected-AOC GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | L3 | Rejected-AOC Selected | |
| 4 | L4₹27.9 L+₹5.9 L (26.8%)Rejected-AOC | L4 | Rejected-AOC Selected |
Tender Value
₹26.8 L
EMD Value
₹53,630
Closing Date
2 Jul 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Addition/Alteration work in Electrical Installations in Lockup area at Tis Hazari Court Complex, Delhi
2019_PWD_174724_1
93/EE (E)/PWD DHC and ND/Central /2019-20
Open Tender
Electrical Works
Works
60 days
Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹53,630
11 Nov 2020
21 Jun 2019
2 Jul 2019
21 Jun 2019
2 Jul 2019
21 Jun 2019
Amount
Supplying, installing, testing and commissioning of double skin construction air washer unit with DIDW class-I centrifugal fan (Efficiency >75%), TEFC weather proof motor of IP55 protection at 415±10% volts, 3 phase, 50 cycles power and high efficiency(EFF-I), belt driven, multi sheave pulley mounted on motor and fan shaft, belt guard, motor and fan mounted on common base with metallistik vibration isolators. Fan capacity shall be based on outlet velocity not exceeding 550 M/minute and fan speed not exceeding 1000 RPM, horizontal mono block pumps (1 W + 1 Standby) of suitable rating, of factory mounted on GI channel base with electric motor for circulation of water. Total static pressure & Motor ratings shall be checked by Vendor based on ducting layout. Pumps shall be aligned and suitable for 415±10% volts, 50 cycle’s 3 phase power supply. One No. 3 phase isolator switch in weather proof enclosure shall be provided near motor Pumps shall be aligned and suitable for 415±10% volts, 50 cycles, 3 phase power supply. One No. 3 phase isolator switch in weather proof enclosure shall be provided near motor. etc complete. as required. a) 14000 CFM
Supplying, installation and testing of factory Fabricated GSS sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers inclusive of all necessary supports by MS structural steel, if required, hangers, clamp supports from walls, floors and ceiling including cutting holes and chases in brick, R.C.C. work, making good the same to original condition etc as per approved drawings and specifications of following sheet thickness including painting with one coat of primer and two coats of paint to supports of MS work etc. complete as required. a) 20 gauge galvanised sheet steel (1.0 mm)
b) 18 gauge galvanised sheet steel (1.25 mm)
Supplying, Fabrication, installation and testing of handmade site fabricated sheet metal ducts, as per the IS-655 in accordance with the approved shop drawings and as required by the specifications. The specifications shall be, as per NIT. Quoted price shall be inclusive of all necessary supports by MS structural steel, if required, hangers, clamp supports from walls, floors and ceiling including cutting holes and chases in brick, R.C.C. work, making good the same to original condition complete in all respect with painting with one coat of primer and two coats of paint to supports of MS work etc. complete as required. a) 20 gauge galvanised sheet steel (1.0 mm)
b) 18 gauge galvanised sheet steel (1.25 mm)
Supplying, fabrication, installation and testing the flexible Canvas constructed of fire resistant double resin sleeve etc complete as required, as per the approved drawings.
Supplying, installation, testing and commissioning of GI volume control duct damper in supply air duct collars complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc. etc complete as required.
Supplying and installation of External Thermal closed cell crosslinked polyethelene/Nitrile rubber insulation on ducts, as per the approved specifications. Quoted price shall be inclusive of adhesive, tapes etc complete as required a) 13 mm thickness insulation for supply & return air ducts
Supplying, installing, testing and commissioning of panel motor starter, as per air washer capacity complete with ampers meter, volts meter, overload protection, single phase preventer, indictor light, OFF/ON push button, auto/manual switch, 6 way connector including connection testing etc., as required.
Supplying and installing of following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, bends, Tee, Cross Member, Reducer suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. a) 100 mm width X 50 mm depth X 1.6 mm thickness
b) 150 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing of 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying, installation, testing & commissioning of floor mounted, front openable outdoor type cubical panel board, 300 mm deep suitable for 415Volts, 3 Phase,4 wire, 50 Hz, AC supply with IP:66 protection and approximate size of 2 sq meters suitable for mounting of followings switchgears, fabricated in compartmentalized design with 2mm thickness CRCA sheet including powder coated painting with approved colour in even shade, having suitable size TPN Aluminum bus bars of high conductivity minimum 1.5 times of incommer rating, DMC/SMC bus bars supports, bottom base channel of MS section not less than 75mm x 50mm x 5mm thickness, 2 Nos. earth studs, solid connections from main bus bar to switch gears with required size of Aluminum bus bars and control wiring with 1.5sq.mm FRLS PVC insulated copper conductor single core cable, cable alleys, suitable foundation, connections etc as required
Providing & fixing following switchgears and accessories in the existing cubical panel board including drilling holes and making connections, testing etc. as required. a) 250 ampers 35KA breaking capacity TP MCCB (Icu = 100% Ics)
b) 100 ampers 25 KA breaking capacity TP MCCB (Icu = 100% Ics)
c) Digital Voltmeter with toggle switch.
d) Digital Ammeter with CT and toggle switch
e) Indicating light LED type 3nos .
Earthing with G.I. earth pipe 4.5 meters long, 40 mm diameter including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Installation of WTAC unit in the existing window including modification in the window, sealing the gap with ply etc. as required at site of work. including sealing the gap etc. complete as required at site of work. a) 1.5 TR Capacity Window Type Air Conditioner unit
b) 2.0 TR Capacity Window Type Air Conditioner unit
Installation of STAC unit complete with indoor & outdoor units including refrigerant connection, electrical connection, testing etc. as required at site of work. a) 1.5 TR Capacity Split Type Air Conditioner unit
b) 2.0 TR Capacity Split Type Air Conditioner unit
Supplying, installation, testing & commissioning of following capacity Window type Air-Conditioner unit suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection including accessories, fixing on window including wooden work (fixing plywood of appropriate size) repairing of wall/window with minor civil work at site etc as required. a) 2 TR Capacity Window Type Air Conditioner unit
Less Credit for following items after dismantling the same under buy back arrangement etc. a) 1.5/2.0 TR capacity WTAC unit
b) 1.5/2.0 TR capacity STAC unit
Aas Electric Company
Krishna Electreical Works
Classic Refrigeration Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .