Risk and Cost Tender for Balance work of Construction of North East Centre of Indian Statistical Institute at Tezpur, Assam
NBCC/SBG/NER/ISI/TENDER/2021/04
NBCC/SBG/NER/ISI/TENDER/2021/04
Open Tender-Domestic
Civil Works General
Sonitpur, Assam
₹11,800
Exempted
21 Sept 2021
24 Aug 2021
21 Sept 2021
21 Sept 2021
29 Oct 2021
Bill of Quantity
Rate Amount Rate Amount
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 315.53 13.95 4401.6435
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 426.41 125.95 53706.3395
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 1136.58 125.75 142924.935
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 38.66 917.75 35480.215
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 3 6547.7 19643.1
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
Extra cement concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc.
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 7.34 193.95 1423.593
2.08 4.1 Providing and laying in position cement concrete of specified
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum
aggregate 20 mm nominal size). 265693.834
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 88.51 7250.05 641701.9255
3.03 5.22 Reinforcement for RCC work including straightening,
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting,
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 0 56.54150203 0
Part Rate Admin Block Kg
3.05 5.9 Centering and shuttering including strutting, propping etc. and
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 283.67 422.3 119793.841
5.9.5 access platform
Lintels, beams, plinth beams, girders, bressumers and Sqm 896.58 342.9 307437.282
5.9.7 cantilevers
Stairs, (excluding landings) except spiral- staircases. Sqm 8.42 419.35 3530.927
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 198.67 467.85 92947.7595
5.9.4 Shelves Sqm
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 36.37 193.95 7053.9615
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
5.9.16.1 Under 20 cm wide metre 0 122.2 0
5.9.14 Extra for shuttering in circular work (20% of respective Sqm
3.06 5.35 centering
Add and shuttering
for using items)
extra cement in the items of design mix over and Quintal 111.32 672.75 74890.53
3.07 5.11 above theadditional
Extra for specified cement
height incontent therein.
centering, shuttering where ever
required with adequate bracing, propping etc., including cost of
Digitally signed by
AVANISH AVANISH KUMAR
KUMAR 18:33:21 IST
Rate Amount Rate Amount
5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan Sqm 574 171.5 98441
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm
plinth and string courses etc. 1409803.88
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
Cement mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 49.12 4751.65 233401.048
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular)
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
with 150mm/230mm/300 mm thick AAC blocks in super Cum 240 5687.1 1364904
Substitute Diff Item No 6.4.2 to 6.47
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry
with 100 mm thick AAC blocks in super structure above plinth
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 56.35 6818.6 384228.11
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 12 1796.65 21559.8
7.25 Providing and fixing stainless steel cramps of required size and Kgs
shape for 21559.8
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 13 3113.3 40472.9
6.02 8.5 Extra for providing opening of required size & shape for each 15 427.95 6419.25
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 26 266.25 6922.5
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
6.05 8.13 Providing and laying Polished Granite stone flooring in
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 95 306.25 29093.75
Providing edge moulding to 18 mm thick marble stone
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to
8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen
8.2.2.1 Area of slab upto 0.50 sqm Sqm
8.12 Providing and laying flamed finish Granite stone flooring in
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm
Brown, Cat Eye or equivalent. 188982.886
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 0.82 92743.05 76049.301
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
Part necessary
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 51 212.45 10834.95
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 12 88.1 1057.2
7.05 9.100 Providing and fixing aluminium handle ISI marked
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 52 51.1 2657.2
7.06 9.101 Providing and fixing aluminium hanging floor door
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 6 38 228
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 6 622.15 3732.9
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 45.78 518 67471.84
Substitute Diff Item No 9.127.1 to 9.127.2
9.127.2 1.0mm thick Sqm
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 192 118.6 22771.2
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
2nd classframes with iron screws, plugs and priming coat on
Rate Amount Rate Amount
9.66 Providing and fixing ISI marked oxidised M.S. handles
9.66.3 conforming
75 mm to IS:4992 with necessary screws etc. complete : each
9.67 Providing and fixing oxidised M.S. hasp and staple (safety
9.67.2 type)mm
115 conforming to IS : 363 with necessary screws etc. each
9.68 Providing and fixing oxidised M.S. casement stays (straight peg
9.68.1 type)mm
300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm
Extraminimum depthvision
for providing on allpanel
edgesnotof flush door shutters
exceeding 0.1 sqm (over
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
9.7 Providing and fixing panelling or panelling and glazing in
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding, Kgs 166 472.4 78418.4
8.03 10.11 Providing and fixing factory made ISI marked steel
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs
8.04 21.1 cement
Providingconcrete
and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
21.1.1 ventilators
For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 384.5 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
10.27 Providing and fixing carbon steel galvanised ( minimum
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded
10.7 Providing and fixing ball bearing for rolling shutters. each
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 44.63 1119.4 49958.822
Part Rate Admin Block 554.37 55.97 31028.09
11.46 Providing and laying Vitrified tiles in different sizes (thickness
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 250.66 744.8 186691.568
Part Rate Adminto IS: 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick
25 mm laid over and jointed with grey cement slurry mixed
Part Rate Admin Block 86.71 231.6199977 20083.77
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 4 1238.2 4952.8
11.37 dado and pillars
Providing and layinglaid Ceramic
on 12 mmglazed(average)
floor thick cement
tiles of size Sqm
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 13.29 747.9 9939.591
Part Rate Admin to Block
be specified by the manufacturer), of 1st 167.71 152.6035359 25593.139
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand
with aggregate)
20 mm nominalfinished
sizewith a floating
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeterfalse
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at allmm madeincluding
height of 0.40 mm
1200 and fixing
mm centre of frame
to centre, onework made
flange fixedofto special sections,
the ceiling with
mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 958.65 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 227.37 438.45 99690.3765
Rate Adminthickness
Block of approved size) on roofs jointed 905.63 77.71 70376.4935
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each
12.21 cm cementgola
Providing concrete
cement :concrete
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre
12.44 Providing and fixing to the inlet mouth of rain water pipe Each
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
"T" runners in be
usingon GIinter
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
plasterboard having glass fibre conforming to IS: 2095 part I, of 197341.932
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
Rate Amount Rate Amount
11.02 13.16 6 mm cement plaster of mix:
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 42.11 255.55 10761.2105
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 569.75 71 40452.25
11.06 13.61 Painting with synthetic enamel paint of approved brand
or more coats toon
even shade Sqm 10 78.4 784
11.07 13.45 Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ Sqm 1452 150.65 218743.8
Distempering over and
washable coat of exterior of
13.41.1 approved
New brandor more
work (two and manufacture
coats) overtoand give an even shade
including water : Sqm 476 93.7 44601.2
11.09 thinnable priming
13.50 Applying primingcoatcoat with cement primer
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat)
13.68.1 Two or more coats on new works including a coat of wood filler Sqm
11.11 13.80 Providing and applying white cement based putty of average Sqm
thickness 1 mm, of approved brand and manufacturer, over the 506555.1605
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 2117 444.9 941853.3
Part Ratecoating
Admin50Block micron) 175 155.71 27249.25
12.02 21.3 Providing and fixing glazing in aluminium door, window,
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 95.64 1003.95 96017.778
12.03 21.8 Filling the gap in between aluminium frame & adjacent
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 131.91 62.45 8237.7795
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 102 359 36618
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 123 55.5 6826.5
12.06 21.16 Providing and fixing aluminium round shape handle of outer
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 195 68.3 13318.5
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each
17.32 tubular handle
Providing bar mirror of superior glass (of approved
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required
21.1.2 shade accordingofto doors,
For shutters IS: 1868,windows
Minimum&anodic coating including
ventilators of grade
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade
21.16 Providing and fixing aluminium round shape handle of outer
Anodized (ACwith15SS screws etc. complete as per direction of
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 37 505.9 18718.3
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 149.47 327.55 48958.8985
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
for final Sqm 7 1034.65 7242.55
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 63.05 5583.8 352058.59
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
coarse sand) mixed
(iii) Finishing with water
top with stone proofing
aggregatecompound
nominal size spreading @ 8 cudm/sqm thoroughly embedded in
Rate Amount Rate Amount
22.1.1 Using rough kota stone. Sqm
22.2 Providing and laying integral cement based treatment for water
22.2.1 proofing
rough vertical
Kota stone surface by fixing specified stone slab Sqm
22.4 Providing and Placing in position suitable PVC water stops
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 30 362.6 10878
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 17.93 1801.53 32301.4329
dado and pillars laid on 12 mm (average) thick cement 43179.4329
SUB TOTAL (A) 7157577.086
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 262.83 13.95 3666.4785
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 1513.75 125.95 190656.8125
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 2622.24 125.75 329746.68
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 68.76 917.75 63104.49
1.06 2.34 watering,
Supplyingramming,
chemicalconsolidating
emulsion in andsealed
dressing complete.
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 1879 51.75 97238.25
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 3 6547.7 19643.1
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc.
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum
aggregate 20 mm nominal size). 414774.4455
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
level Cum 0 6446.45 0
3.02 5.33.2 All works above plinth level upto floor V level Cum 128.17 7250.05 929238.9085
3.03 5.22 Reinforcement for RCC work including straightening,
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 2 56.6 113.2
3.04 5.22A Reinforcement for RCC work including straightening, cutting,
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 3746.43 56.6 212047.938
3.05 5.9 Centering and shuttering including strutting, propping etc. and
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 267.21 422.3 112842.783
5.9.5 access platform
Lintels, beams, plinth beams, girders, bressumers and Sqm 203.59 342.9 69811.011
5.9.7 cantilevers
Stairs, (excluding landings) except spiral- staircases. Sqm 48 419.35 20128.8
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 113.27 467.85 52993.3695
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 86 193.95 16679.7
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
5.9.16.1 Under 20 cm wide metre 364 122.2 44480.8
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 22 93.57 2058.54
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 34.56 672.75 23250.24
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 378.6 0
plinth and string courses etc. 1678339.247
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation
Rate Amount Rate Amount
6.1.2 a) Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 32.55 4751.65 154666.2075
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular)
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
with 150mm/230mm/300 mm thick AAC blocks in super Cum 542 5687.1 3082408.2
Substitute Diff Item No 6.4.2 to 6.47
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry
with 100 mm thick AAC blocks in super structure above plinth
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 63.71 6818.6 434413.006
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm
7.25 Providing and fixing stainless steel cramps of required size and Kgs
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 19 3113.3 59152.7
6.02 8.5 Extra for providing opening of required size & shape for each 21 427.95 8986.95
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
6.05 8.13 Providing and laying Polished Granite stone flooring in
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 197 306.25 60331.25
Providing edge moulding to 18 mm thick marble stone
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to
8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen
8.2.2.1 Area of slab upto 0.50 sqm Sqm
8.12 Providing and laying flamed finish Granite stone flooring in
8.12.1 required designgranite
Flamed finish and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Brown, Cat Eye or equivalent. 578899.785
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 0.57 92743.05 52863.5385
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 80 212.45 16996
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 80 88.1 7048
7.05 9.100 Providing and fixing aluminium handle ISI marked
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 125 51.1 6387.5
7.06 9.101 Providing and fixing aluminium hanging floor door
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 75 38 2850
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 58 622.15 36084.7
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 302 837.4 252894.8
Substitute Diff Item No 9.127.1 to 9.127.2
9.127.2 1.0mm thick Sqm
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 390 118.6 46254
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
9.40.1 2nd classframes with iron screws, plugs and priming coat on
9.40.1.1 50x12 mm meter
9.66 Providing and fixing ISI marked oxidised M.S. handles
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each
9.67 Providing and fixing oxidised M.S. hasp and staple (safety
9.67.2 115 conforming to IS : 363 with necessary screws etc. each
9.68 Providing and fixing oxidised M.S. casement stays (straight peg
type) with necessary screws etc. complete.
Rate Amount Rate Amount
9.68.1 300 mm weighing not less than 200 gms each
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm
9.24 mm minimum
Extra depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
9.7 Providing and fixing panelling or panelling and glazing in
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding, Kgs 691 472.4 326428.4
8.03 10.11 Providing and fixing factory made ISI marked steel
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
21.1.1 ventilators
For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent Kgs
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
10.27 Providing and fixing carbon steel galvanised ( minimum
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded
10.7 Providing and fixing ball bearing for rolling shutters. each
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 1364.01 314.65 429188.59
Part Rate Admin Block
Part Rate Academic Block
11.46 Providing and laying Vitrified tiles in different sizes (thickness
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 179 1135.2 203200.8
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 267.66 744.8 199353.168
9.03 11.26 conforming
Kota stone toslab
15622 (thickness
over 20 mm to (average)
25 mmlaid over and jointed with grey cement slurry mixed
Part Rate Admin Block
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 3 1238.2 3714.6
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 473 747.9 353756.7
Part Rate Admin to Block
be specified by the manufacturer), of 1st
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand
with aggregate)
20 mm nominalfinished
sizewith a floating
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeter false
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 958.65 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 1447 438.45 634437.15
Rate Adminthickness
Block of approved size) on roofs jointed
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 4 187.6 750.4
12.21 cm cementgola
Providing concrete
cement :concrete
sand (1: 4cement
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 4 40.9 163.6
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
plasterboard having glass fibre conforming to IS: 2095 part I, of 1102365.714
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix:
13.16.1 1:3 (1 cement : 3 fine sand) Sqm 0 143.8 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 276.55 255.55 70672.3525
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content
Rate Amount Rate Amount
Part Rate Academic Block 2643.53 7.1 18769.1
Part Rate Canteen Block
11.06 13.61 Painting with synthetic enamel paint of approved brand
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 10 78.4 784
11.07 13.45 Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ Sqm 1565 150.65 235767.25
Distempering over and
washablecoat of exterior of
13.41.1 approved
New work (two brandor more
and manufacture
coats) overtoand
give an even shade
including water : Sqm 295.82 93.7 27718.334
Part priming Block
Rate Canteen coat with cement primer
11.09 13.50 Applying priming coat
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat)
13.68.1 Two or more coats on new works including a coat of wood filler Sqm
11.11 13.80 Providing and applying white cement based putty of average Sqm
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 1540.93 444.9 685559.757
Part Ratecoating
Admin50Block micron) 1266.07 155.71 197139.54
Part Rate Academic Block
12.02 21.3 Providing and fixing glazing in aluminium door, window,
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 256 1003.95 257011.2
12.03 21.8 Filling the gap in between aluminium frame & adjacent
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 733 62.45 45775.85
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 239 359 85801
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 239 55.5 13264.5
12.06 21.16 Providing and fixing aluminium round shape handle of outer
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 239 68.3 16323.7
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each
17.32 tubular handle
Providing bar mirror of superior glass (of approved
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
21.3.3 shade according
With float to IS: of
glass panes 1868,
thicknessanodic coating of grade
21.16 Providing and fixing aluminium round shape handle of outer
Anodized (ACwith15SS screws etc. complete as per direction of
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 81 505.9 40977.9
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 103.53 327.55 33911.2515
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 109 5583.8 608634.2
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm
22.2 Providing and laying integral cement based treatment for water
proofing on the vertical surface by fixing specified stone slab
Rate Amount Rate Amount
22.2.1 Using rough Kota stone Sqm
22.4 Providing and Placing in position suitable PVC water stops
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 65 362.6 23569
14.02 MR dry brickstone
Granite aggregate
40 mmthickthick nominal
in risers size including
of steps, skirting, Sqm 29.22 1801.53 52640.7066
dado and pillars laid on 12 mm (average) thick cement 76209.7066
SUB TOTAL (B) 13000305.03
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 104.29 13.95 1454.8455
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 126.91 125.95 15984.3145
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 711.42 125.75 89461.065
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 40.62 917.75 37279.005
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment of soil under existing floors anti-termite treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apartE.C. including
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 662 51.75 34258.5
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 162657.694
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 29.15 7250.05 211338.9575
3.03 5.22 Reinforcement for RCC work including straightening, -31470.5 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 7314.53 56.6 414002.398
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 142.27 422.3 60080.621
5.9.5 access platform
Lintels, beams, plinth beams, girders, bressumers and Sqm 137.61 342.9 47186.469
5.9.7 cantilevers
Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 81.52 467.85 38139.132
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 35 193.95 6788.25
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 21 93.57 1964.97
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 42.69 672.75 28719.6975
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 0 0
plinth and string courses etc. 1035633.131
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 49.04 4751.65 233020.916
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular)
class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
Rate Amount Rate Amount
4.03 6.12 Half brick masonry with common burnt clay
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 94 5687.1 534587.4
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 16.445 6818.6 112131.877
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 0 1796.65 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,
Granite of anypremoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 31 3113.3 96512.3
6.02 8.5 Extra for providing opening of required size & shape for each 12 427.95 5135.4
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 44 266.25 11715
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 88 306.25 26950
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 13 3351.95 43575.35
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Brown, Cat Eye or equivalent. 604458.65
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 1 92743.05 92743.05
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 8 212.45 1699.6
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 4 88.1 352.4
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 24 51.1 1226.4
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 12 38 456
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 4 622.15 2488.6
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked withhighsix leverslaminated
pressure and a pairsheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 44 837.4 36845.6
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 72 118.6 8539.2
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
9.40.1 2nd classframes with iron screws, plugs and priming coat on
9.40.1.1 50x12 mm meter
9.66 Providing and fixing ISI marked oxidised M.S. handles
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each
9.67 Providing and fixing oxidised M.S. hasp and staple (safety
9.67.2 115 conforming to IS : 363 with necessary screws etc. each
9.68 Providing and fixing oxidised M.S. casement stays (straight peg
9.68.1 300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 22 365.85 8048.7
Extraminimum depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
type of flush doors (cost of glass excluded) (overall area of door
Rate Amount Rate Amount
9.24.1 Rectangular or square Sqm
9.7 Providing and fixing panelling or panelling and glazing in
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 50 85.95 4297.5
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding, Kgs
8.03 10.11 Providing and fixing factory made ISI marked steel
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 0 113.6 0
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
21.1.1 ventilators
For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent Kgs
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
10.27 Providing and fixing carbon steel galvanised ( minimum
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded
10.7 Providing and fixing ball bearing for rolling shutters. each
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 320 1119.4 358208
11.46 Providing and laying Vitrified tiles in different sizes (thickness
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 285 1135.2 323532
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 27.05 744.8 20146.84
9.03 11.26 conforming
Kota stone toslab
15622 (thickness
over 20 mm to (average)
25 mm laid over and jointed with grey cement slurry mixed
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 2 1238.2 2476.4
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed (average)
floor thick cement
tiles of size Sqm 0 688.35 0
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 127 747.9 94983.3
New 11.3 mm (thickness
Cement to beflooring
concrete specified1:2:4
(1manufacturer), of 1st sand
cement : 2 coarse
40 gradedthickstone
with aggregate)
20 mm nominal finished
sizewith a floating
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicatea Perimeter false
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with
mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 1224 438.45 536662.8
Part Rate nominal
Block of approved size) on roofs jointed
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each
12.21 cm cementgola
Providing concrete
mm (1 in cement
cement :concrete
sand (1: 4cement
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep aggregate 10 mm and down gauge),
12.44 Providing and fixing to the inlet mouth of rain water pipe Each
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
"T" runners in be
horizontalfrom level,ceiling
usingon GIinter
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
plasterboard having glass fibre conforming to IS: 2095 part I, of 536662.8
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
13.4.2 1:6 (1 cement : 6 coarse sand) Sqm 0 168.25 0
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 193.95 255.55 49563.9225
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 146 118.7 17330.2
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 61.68 35.5 2189.64
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 10 78.4 784
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 802 150.65 120821.3
Distempering over andoil including
washable coat of exterior of
distemper 0 0 0
approved brand and manufacture to give an even shade :
Rate Amount Rate Amount
13.41.1 New work (two or more coats) over and including water Sqm 101.92 93.7 9549.904
Part priming Block
Rate Canteen coat with cement primer 561.08 46.85 26286.598
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the 0 0 0
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 690 444.9 306981
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 56 1003.95 56221.2
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 203 62.45 12677.35
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 46 359 16514
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 92 55.5 5106
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 92 68.3 6283.6
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 10 384.5 3845
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 8 4608.85 36870.8
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 8 509.3 4074.4
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 6 1323.1 7938.6
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade
21.16 Providing and fixing aluminium round shape handle of outer
Anodized (ACwith15SS screws etc. complete as per direction of
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
(ii) IInd coursemixed
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 469.08 327.55 153647.154
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
22.7.1 for a minimum
With period of of
average thickness two120 weeks
mm for andcuring
minimum and thickness
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 92 5583.8 513709.6
Providingaggregate 20 mm
and laying nominal
integral size)based treatment for water
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm
22.2 Providing and laying integral cement based treatment for water
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm
22.4 Providing and Placing in position suitable PVC water stops
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 27 1801.53 48641.31
dado and pillars laid on 12 mm (average) thick cement 48641.31
Rate Amount Rate Amount
SUB TOTAL (C) 5893942.612
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 301.33 13.95 4203.5535
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 1438.08 125.95 181126.176
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 2343.45 125.75 294688.8375
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 115.64 917.75 106128.61
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 99.85 185.95 18567.1075
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 1972 51.75 102051
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 4 6547.7 26190.8
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 24.56 193.95 4763.412
2.08 4.1 Providing and laying in position cement concrete of specified
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum
aggregate 20 mm nominal size). 662639.819
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
level Cum 0 6446.45 0
3.02 5.33.2 All works above plinth level upto floor V level Cum 466.85 7250.05 3384685.843
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 7963.63 56.6 450741.458
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
Foundation,of form for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 2202.45 422.3 930094.635
Part Rateplatform
Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 1538.33 342.9 527493.357
Part Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 32 419.35 13419.2
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 474.57 467.85 222027.5745
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 252 193.95 48875.4
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 753 122.2 92016.6
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 428.3 672.75 288138.825
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm
plinth and string courses etc. 6004866.222
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular)
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay
F.P.S. (non modular) bricks of class designation 7.5
Rate Amount Rate Amount
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
with 150mm/230mm/300 mm thick AAC blocks in super Cum 577 5687.1 3281456.7
Substitute Diff Item No 6.4.2 to 6.47
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry
with 100 mm thick AAC blocks in super structure above plinth
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 26.91 6818.6 183488.526
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm
7.25 Providing and fixing stainless steel cramps of required size and Kgs
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 32 3113.3 99625.6
6.02 8.5 Extra for providing opening of required size & shape for each 21 427.95 8986.95
6.03 8.4 wash basin/kitchen
Extra for fixing marblesink/granite
stone,platform,
above metre 50 266.25 13312.5
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
6.05 8.13 Providing and laying Polished Granite stone flooring in
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 87 306.25 26643.75
Providing edge moulding to 18 mm thick marble stone
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to
8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen
8.2.2.1 Area of slab upto 0.50 sqm Sqm
8.12 Providing and laying flamed finish Granite stone flooring in
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm
Brown, Cat Eye or equivalent. 342457
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 3.12 92743.05 289358.316
Part Rate Boys Hostel 2.88 9274.3 26709.984
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 116 212.45 24644.2
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked
9.97.2 anodised
250x10 mm (anodic coating not less than grade AC 10 as per Each 58 88.1 5109.8
7.05 9.100 Providing and fixing aluminium handle ISI marked
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 294 51.1 15023.4
7.06 9.101 Providing and fixing aluminium hanging floor door
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 147 38 5586
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 138 622.15 85856.7
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked withhighsix leverslaminated
pressure and a pairsheet of
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 634 837.4 530911.6
Substitute Diff Item No 9.127.1 to 9.127.2
9.127.2 1.0mm thick Sqm
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 828 118.6 98200.8
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
9.40.1 2nd classframes with iron screws, plugs and priming coat on
9.40.1.1 50x12 mm meter
9.66 Providing and fixing ISI marked oxidised M.S. handles
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 432 19.15 8272.8
9.67 Providing and fixing oxidised M.S. hasp and staple (safety
9.67.2 115 conforming to IS : 363 with necessary screws etc. each 432 20.3 8769.6
9.68 Providing and fixing oxidised M.S. casement stays (straight peg
9.68.1 300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm
9.24 mm minimum
Extra depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
type of flush or
9.24.1 Rectangular doors (cost of glass excluded) (overall area of door
9.7 Providing and fixing panelling or panelling and glazing in
Rate Amount Rate Amount
9.7.7 Float glass panes
9.7.7.2 5.5 mm thick glass panes Sqm
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
of Hollow tubes, channels, plates etc., including welding, Kgs
8.03 10.11 Providing and fixing factory made ISI marked steel
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 3511 113.6 398849.6
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
21.1.1 ventilators
For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent Kgs
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
10.27 Providing and fixing carbon steel galvanised ( minimum
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded
10.7 Providing and fixing ball bearing for rolling shutters. each
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm
Part Rate Admin Block
Part Rate Academic Block
11.46 Providing and laying Vitrified tiles in different sizes (thickness
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 526 744.8 391764.8
Rate Admin 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick
25 mm laid over and jointed with grey cement slurry mixed
Part Rate Admin Block
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 1814 688.35 1248666.9
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm
Part Rate Admin to Block
be specified by the manufacturer), of 1st
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand
40 graded stone
thick with aggregate)
20 mm nominalfinished
sizewith a floating
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeter false
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 1506 438.45 660305.7
Part Ratenominal
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 10 187.6 1876
12.21 cm cementgola
Providing concrete
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 10 40.9 409
10.05 12.52 cast iron grating
Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 872296.7
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix:
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 2905 255.55 742372.75
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 3207 118.7 380670.9
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior
13.83.2 grade, having VOC (Volatile Organic Compound ) content
Two coats Sqm 3207 71 227697
Rate Amount Rate Amount
Part Rate Academic Block
Part Rate Canteen Block
11.06 13.61 Painting with synthetic enamel paint of approved brand
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 276 78.4 21638.4
11.07 13.45 Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ Sqm 2905 150.65 437638.25
Distempering over and
washablecoat of exterior of
13.41.1 approved
New work (twobrandor more
and manufacture
coats) overtoand
give an even shade
including water : Sqm 1900 93.7 178030
thinnable priming Block
Part Rate Canteen coat with cement primer
11.09 13.50 Applying priming coat
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat)
13.68.1 Two or more coats on new works including a coat of wood filler Sqm
11.11 13.80 Providing and applying white cement based putty of average Sqm
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs
Part Ratecoating
Admin50Block micron)
Part Rate Academic Block
12.02 21.3 Providing and fixing glazing in aluminium door, window,
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 320 1003.95 321264
12.03 21.8 Filling the gap in between aluminium frame & adjacent
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 940 62.45 58703
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 359 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 55.5 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 68.3 0
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each
17.32 tubular handle
Providing bar mirror of superior glass (of approved
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each
21.1 Providing and fixing aluminium work for doors, windows,
21.1.1 ventilators
For and partitions with extruded built up standard
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade
21.16 Providing and fixing aluminium round shape handle of outer
Anodized (ACwith15SS screws etc. complete as per direction of
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 175 505.9 88532.5
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 1506 327.55 493290.3
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
b) Laying of cement
cement admixed
concrete usingwith proprietary
broken water bats
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 113 5583.8 630969.4
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm
22.2 Providing and laying integral cement based treatment for water
22.2.1 proofing
Using rough on the
stone surface by fixing specified stone slab Sqm
Rate Amount Rate Amount
22.4 Providing and Placing in position suitable PVC water stops
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm
dado and pillars laid on 12 mm (average) thick cement 0
SUB TOTAL (D) 21245559.72
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 1040.06 13.95 14508.837
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 2038.94 125.95 256804.493
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 1769.06 125.75 222459.295
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 55.17 917.75 50632.2675
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL anti-termite
Treatment of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 1801 51.75 93201.75
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 3 6547.7 19643.1
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 17.42 193.95 3378.609
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 555989.1275
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 305.064 7250.05 2211729.253
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 22792.44 56.6 1290052.104
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 559.11 422.3 236112.153
Part Rateplatform
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 604.4 342.9 207248.76
Part Rate Girls Hostel 2337.6 15.91115246 37193.91
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 22 419.35 9225.7
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 283.81 467.85 132780.5085
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 204 193.95 39565.8
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 675 122.2 82485
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 385.86 672.75 259587.315
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm
plinth and string courses etc. 4841175.175
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
Rate Amount Rate Amount
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 388 5687.1 2206594.8
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 26.91 6818.6 183488.526
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 0 1796.65 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 521.1 0
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut 0 0 0
8.2.2.2 Area of slab over 0.50 sum. Sqm 28 3113.3 87172.4
6.02 8.5 Extra for providing opening of required size & shape for each 13 427.95 5563.35
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 38 266.25 10117.5
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 62 306.25 18987.5
Providing edge moulding to 18 mm thick marble stone
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to
8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen
8.2.2.1 Area of slab upto 0.50 sqm Sqm
8.12 Providing and laying flamed finish Granite stone flooring in
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm
Brown, Cat Eye or equivalent. 277538.85
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 2.08 92743.05 192905.544
Part Rate Girls Hostel 1.92 9274.3 17806.656
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
Part necessary
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 84 212.45 17845.8
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 42 88.1 3700.2
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 182 51.1 9300.2
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 91 38 3458
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 82 622.15 51016.3
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
sheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 438 837.4 366781.2
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 492 118.6 58351.2
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 336 19.15 6434.4
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
115 mm conforming to IS : 363 with necessary screws etc. each 336 20.3 6820.8
Rate Amount Rate Amount
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 type)mm
300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
edgesnotof flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 2498 113.6 283772.8
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 332 744.8 247273.6
Part Rate Adminto IS: 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mmlaid over and jointed with grey cement slurry mixed
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing and layinglaid Ceramic
on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 1438 688.35 989847.3
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeter false
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 1488 438.45 652413.6
Rate Adminthickness
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 10 187.6 1876
12.21 cm cementgola
Providing concrete
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 97 153 14841
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 10 40.9 409
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 798359
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 1065.03 255.55 272168.4165
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 2386 118.7 283218.2
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
grade, having VOC (Volatile Organic Compound ) content
Rate Amount Rate Amount
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 202 78.4 15836.8
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 2437 150.65 367134.05
Distempering over and
washablecoat of exterior of
distemper 0 0 0
13.41.1 approved
New work (two brandor more
and manufacture
coats) overtoand
give an even shade
including water : Sqm 1340 93.7 125558
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the 0 0 0
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 228 1003.95 228900.6
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 671 62.45 41903.95
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 359 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 55.5 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 68.3 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shade according
With float to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of 0 0 0
of 20mm with waterplaster
cement proofing
cement : 3 0 0 0
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied 0 0 0
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 73 505.9 36930.7
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 1488 327.55 487394.4
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 112 5583.8 625385.6
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
proofing on the vertical surface by fixing specified stone slab
Rate Amount Rate Amount
22.2.1 Using rough Kota stone Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 32 362.6 11603.2
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 14 1801.53 25221.42
dado and pillars laid on 12 mm (average) thick cement 36824.62
SUB TOTAL (E) 16529467.79
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 0 13.95 0
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 285.8 125.95 35996.51
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 817.35 125.75 102781.7625
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 18.57 917.75 17042.6175
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 1273 51.75 65877.75
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 2 6547.7 13095.4
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 71.88 193.95 13941.126
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 237692.0285
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
level Cum 0 6446.45 0
3.02 5.33.2 All works above plinth level upto floor V level Cum 535.12 7250.05 3879646.756
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.51251096 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 60188.6 56.51251139 3401408.943
Part Rate Admin Block Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Head's quarter Kg 0 0 0
Part Rate T Qtr 60 Sqm Kg 0 0 0
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
Foundation,of form for : bases of columns etc. for mass concrete
footing, Sqm 0.2 193.95 38.79
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 1687.1 422.3 712462.33
Part Rateplatform
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 1550.17 342.9 531553.293
Part Rate Guest House 1003.83 36.292 36430.99836
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 39 419.35 16354.65
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 603.6 467.85 282394.26
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 42 193.95 8145.9
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 530 122.2 64766
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering
Add and shuttering
for using items)
extra cement in the items of design mix over and Quintal 501.36 672.75 337289.94
3.07 5.11 above theadditional
Extra for specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
required with adequate bracing, propping etc., including cost of
Rate Amount Rate Amount
5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan Sqm 935 171.5 160352.5
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 0 0
plinth and string courses etc. 9464722.374
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
Cement mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 0 4751.65 0
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
sand) Sqm 0 593.5 0
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 418 5687.1 2377207.8
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 7.245 6818.6 49400.757
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 0 1796.65 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 521.1 0
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 33 3113.3 102738.9
6.02 8.5 Extra for providing opening of required size & shape for each 6 427.95 2567.7
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 50 266.25 13312.5
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 108 306.25 33075
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 0 0 0
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 348520
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 4 92743.05 370972.2
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 182 212.45 38665.9
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 91 88.1 8017.1
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 276 51.1 14103.6
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 138 38 5244
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 47 622.15 29241.05
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
sheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 385 837.4 322399
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 564 118.6 66890.4
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
Rate Amount Rate Amount
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 conforming
75 mm to IS:4992 with necessary screws etc. complete : each 108 19.15 2068.2
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 type)mm
115 conforming to IS : 363 with necessary screws etc. each 108 20.3 2192.4
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 type)mm
300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
edgesnotof flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 1159 113.6 131662.4
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required size M.S.
80x1.20 mm M.S. laths
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Academic Block 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 288 744.8 214502.4
Rate Admin 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 1355 688.35 932714.25
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
40 graded stone
thick with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeterfalse
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at allmm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework made
flange fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 1286 438.45 563846.7
Part Ratenominal
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 0 0
12.21 cm cementgola
Providing concrete
cement :concrete
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 695661.9
Rate Amount Rate Amount
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 2115 255.55 540488.25
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 2432 118.7 288678.4
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 2432 71 172672
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 149 78.4 11681.6
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 2115 150.65 318624.75
Distempering over and
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New brandor more
work (two and manufacture
coats) overtoand give an even shade
including water : Sqm 1366 93.7 127994.2
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
Frenchand manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the 0 0 0
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 106 1003.95 106418.7
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 297 62.45 18547.65
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 4 4608.85 18435.4
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 4 509.3 2037.2
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing compound
or/residual bitumen inapplied
(iv) 1.7course
IVth kg perofsqm400 ofmicron
area. thick PVC sheet (Overlaps cum 55 505.9 27824.5
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric pasted
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry ofcoatsurface
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) The whole mortarterrace
of mix 1:4 (1 cement
so finished : 4flooded
shall be coarse sand)
with water 0 0 0
for a minimum period of two weeks for curing and for final
Rate Amount Rate Amount
22.7.1 With average thickness of 120 mm and minimum thickness Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 97 5583.8 541628.6
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
25 mm a 25thick
cement base of cement
mortar 1:3 (1mortar 1:33
cement: 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 44 362.6 15954.4
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 22 1801.53 39633.66
dado and pillars laid on 12 mm (average) thick cement 55588.06
SUB TOTAL (F) 19300562.61
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 91.91 13.95 1282.1445
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 9.36 125.95 1178.892
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 190.64 125.75 23972.98
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
20cm in Cum 4 0 0
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 7.38 917.75 6772.995
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 44 185.95 8181.8
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 0 51.75 0
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
proofing 10 47.95 479.5
2.06 4.13 material
Providingin &cement concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 84317.335
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
level Cum 0 6446.45 0
3.02 5.33.2 All works above plinth level upto floor V level Cum 0 7250.05 0
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically Treated andbars
binding all complete. Above Kg 1364.2 56.6 77213.72
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 0 422.3 0
5.9.5 access platform
Lintels, beams, plinth beams, girders, bressumers and Sqm 96.44 342.9 33069.276
5.9.7 cantilevers
Stairs, (excluding landings) except spiral- staircases. Sqm 10 419.35 4193.5
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 1.39 467.85 650.3115
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 23 193.95 4460.85
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 0 122.2 0
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
centering and shuttering items)
Rate Amount Rate Amount
3.06 5.35 Add for using extra cement in the items of design mix over and Quintal 0 672.75 0
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams and etc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm
plinth and string courses etc. 127314.945
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
Cement mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 0.49 4751.65 2328.3085
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 105 5687.1 597145.5
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 16.79 6818.6 114484.294
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 13 1796.65 23356.45
7.25 Providing and fixing stainless steel cramps of required size and Kgs 35 521.1 18238.5
shape for 41594.95
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 5 3113.3 15566.5
6.02 8.5 Extra for providing opening of required size & shape for each 6 427.95 2567.7
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 13 266.25 3461.25
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 14 306.25 4287.5
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 14 3351.95 46927.3
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Brown, Cat Eye or equivalent. 407259.4
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 0.09 92743.05 8346.8745
Part Rate Amenities 0.91 13911.46 12659.4286
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
Part necessary
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 48 212.45 10197.6
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 24 88.1 2114.4
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 48 51.1 2452.8
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 24 38 912
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 24 622.15 14931.6
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
sheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 94 837.4 78715.6
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 144 118.6 17078.4
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
conforming to IS : 2202 (Part I) decorative type, core
Rate Amount Rate Amount
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 conforming
75 mm to IS:4992 with necessary screws etc. complete : each 58 19.15 1110.7
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 type)mm
115 conforming to IS : 363 with necessary screws etc. each 58 20.3 1177.4
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 type)mm
300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
edgesnotof flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 9 162.6 1463.4
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 panelled
Float glassor panes 0 0 0
9.7.7.2 5.5 mm thick glass panes Sqm 1 1456.8 1456.8
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 130 85.95 11173.5
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 0 0 0
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required size M.S.
80x1.20 mm M.S. laths
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 84 688.35 57821.4
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 40 744.8 29792
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 150 744.8 111720
9.03 11.26 conforming
Kota stone toslab
15622 (thickness
over 20 mm to (average)
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed (average)
floor thick cement
tiles of size Sqm 146 688.35 100499.1
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
Extra for preslab.
finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
New 11.3 mm (thickness
Cement to beflooring
concrete specified1:2:4
(1manufacturer), of 1st sand
cement : 2 coarse 0 0 0
40 graded stone
thick with aggregate)
20 mm nominal finished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged 0 0 0
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeterfalse
angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at allmm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework made
flange fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 304 438.45 133288.8
12.22 20 mm nominal
Making thicknesswith
khurra 45x45cm of approved size) on roofs
average minimum jointedof 5
thickness Each 7 187.6 1313.2
12.21 cm cementgola
Providing concrete
cement :concrete
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 7 40.9 286.3
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 134888.3
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0 0
Rate Amount Rate Amount
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 62.83 255.55 16056.2065 16056.2065
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 827 71 58717 58717
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0 0
13.61.1 and manufacture
Two or more coats toon
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 419 150.65 63122.35 63122.35
Distempering over and
washable coat of exterior of
distemper 0 0 0 0
13.41.1 approved
New brandor more
work (two and manufacture
coats) overtoand give an even shade
including water : Sqm 337 93.7 31576.9 31576.9
11.09 thinnable priming
13.50 Applying primingcoatcoat with cement primer 0 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the 0 0 0 0
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing
Powder and coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 577 444.9 256707.3
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 53 1003.95 53209.35
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 157 62.45 9804.65
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 5 4608.85 23044.25
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 4 509.3 2037.2
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 10 1323.1 13231
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 providing
Anodised and fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 9 505.9 4553.1
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 44.97 327.55 14729.9235
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 23 5583.8 128427.4
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using rough size kota
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
Rate Amount Rate Amount
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough vertical
Kota stone surface by fixing specified stone slab Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 15 362.6 5439
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 13 1801.53 23419.89
dado and pillars laid on 12 mm (average) thick cement 28858.89
SUB TOTAL (G) 2975131.355
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 74.6 13.95 1040.67
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 62.89 125.95 7920.9955
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 211.57 125.75 26604.9275
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
20cm in Cum 0 0 0
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 20 917.75 18355
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 33 185.95 6136.35
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 16.95 51.75 877.1625
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
proofing 7 47.95 335.65
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 106454.674
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 10.92 7250.05 79170.546
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 1721.12 56.6 97415.392
Part Rate T Qtr 60 Sqm Kg 4705.88 6.54 30789.628
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 22.72 422.3 9594.656
5.9.5 access platform
Lintels, beams, plinth beams, girders, bressumers and Sqm 35.38 342.9 12131.802
5.9.7 cantilevers
Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 30.76 467.85 14391.066
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 19 193.95 3685.05
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 74 122.2 9042.8
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 14.24 672.75 9579.96
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 0 0
plinth and string courses etc. 285123.267
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
bricks of class designation
Rate Amount Rate Amount
6.1.2 a) Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 5.08 4751.65 24138.382
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 31 5687.1 176300.1
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 9.2 6818.6 62731.12
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 16 1796.65 28746.4
7.25 Providing and fixing stainless steel cramps of required size and Kgs
shape for 28746.4
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 5 3113.3 15566.5
6.02 8.5 Extra for providing opening of required size & shape for each 6 427.95 2567.7
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 11 266.25 2928.75
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 42 306.25 12862.5
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 0 0 0
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required designgranite
Flamed finish and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 72115.55
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 1 92743.05 92743.05
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 20 212.45 4249
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 10 88.1 881
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 28 51.1 1430.8
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 14 38 532
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 14 622.15 8710.1
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
sheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 54 837.4 45219.6
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 84 118.6 9962.4
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 24 19.15 459.6
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 115 conforming to IS : 363 with necessary screws etc. each 24 20.3 487.2
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
type) with necessary screws etc. complete.
Rate Amount Rate Amount
9.68.1 300 mm weighing not less than 200 gms each 24 30.95 742.8
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work, 0 0 0
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 0 0 0
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 323 113.6 36692.8
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm
11.46 Providing and laying Vitrified tiles in different sizes (thickness
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 41 744.8 30536.8
Part Rate Adminto IS: 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing and layinglaid Ceramic
on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 130 688.35 89485.5
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeter false
angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 216 438.45 94705.2
Part Ratenominal
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 0 0
12.21 cm cementgola
Providing concrete
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 12.52 cast iron grating
Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 94705.2
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 260 255.55 66443
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 370 118.7 43919
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade, having VOC (Volatile Organic Compound ) content
Two coats Sqm 370 71 26270
Rate Amount Rate Amount
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 0 78.4 0
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 260 150.65 39169
Distempering over and
washablecoat of exterior of
distemper 0 0 0
13.41.1 approved
New work (twobrandor more
and manufacture
coats) overtoand
give an even shade
including water : Sqm 130 93.7 12181
thinnable priming Block
Part Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including 0 0 0
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 30 1003.95 30118.5
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 77 62.45 4808.65
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 0 0 0
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 15.91 327.55 5211.3205
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) Laying of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 17 5583.8 94924.6
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
Using rough on the
stone surface by fixing specified stone slab Sqm 0 0 0
Rate Amount Rate Amount
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 0 0
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 16 1801.53 28824.48
dado and pillars laid on 12 mm (average) thick cement 28824.48
SUB TOTAL (H) 1737649.149
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 143.24 13.95 1998.198
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 0 125.95 0
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 194.51 125.75 24459.6325
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
20cm in Cum 0 0 0
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 26.96 917.75 24742.54
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 1.45 185.95 269.6275
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL anti-termite
Treatment of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 0 51.75 0
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1.5 6547.7 9821.55
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
proofing 12 47.95 575.4
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 125897.8195
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
3.01 5.33.1 mixed design
All works uptomix M-25
Plinth grade cement concrete for reinforced
level Cum 0 6446.45 0
3.02 5.33.2 All works above plinth level upto floor V level Cum 87.36 7250.05 633364.368
3.03 5.22 Reinforcement for RCC work including straightening, -21942.5 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically Treated andbars
binding all complete. Above Kg 8603.55 56.6 486960.93
Part Rate Admin Block Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Head's quarter Kg 0 0 0
Part Rate T Qtr 60 Sqm Kg 0 0 0
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
footing, Sqm 0 193.95 0
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 387 422.3 163430.1
Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 216.36 342.9 74189.844
Part Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 0.42 467.85 196.497
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 33 193.95 6400.35
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering and shuttering
Add for using items)
extra cement in the items of design mix over and Quintal 73.25 672.75 49278.9375
above the specified cement content therein.
Rate Amount Rate Amount
3.07 5.11 Extra for additional height in centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams and etc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm
plinth and string courses etc. 1445736.527
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
Cement mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 24.28 4751.65 115370.062
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
class designation
1:6 (1 cement : 6 coarse sand) Cum 0 0 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular) bricks:4 of
1:4 (1 cement class
coarse designation 7.5
sand) Sqm 0 0 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 0 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 76.5 5687.1 435063.15
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 15.18 6818.6 103506.348
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 28.5 1796.65 51204.525
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 0 0
shape for 51204.525
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut 0 0 0
8.2.2.2 Area of slab over 0.50 sum. Sqm 12 3113.3 37359.6
6.02 8.5 Extra for providing opening of required size & shape for each 9 427.95 3851.55
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 27 266.25 7188.75
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 63 306.25 19293.75
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 0 0 0
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 124978.8
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 1.5 92743.05 139114.575
Part Rate Admin Block 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Amenities 0 0 0
Part Rate Boys Hostel 0 0 0
Part Rate Girls Hostel 0 0 0
Part Rate T Qtr 90 Sqm 0 0 0
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
with necessary
Part Rate Admin screws
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 30 212.45 6373.5
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 15 88.1 1321.5
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 48 51.1 2452.8
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 24 38 912
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 24 622.15 14931.6
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
sheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 90 837.4 75366
Rate Amount Rate Amount
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 144 118.6 17078.4
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 conforming
75 mm to IS:4992 with necessary screws etc. complete : each 36 19.15 689.4
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 type)mm
115 conforming to IS : 363 with necessary screws etc. each 36 20.3 730.8
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 type)mm
300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
edgesnotof flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 panelled
Float glassor panes 0 0 0
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 0 0 0
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 414 113.6 47030.4
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes 0 0 0
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Academic Block 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 120 744.8 89376
Rate Admin 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 231 688.35 159008.85
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
Extrastone slab.
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
40 graded stone
thick with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate false
a Perimeter wallceiling
angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000 mm
false ceiling at all madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework made
flange fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick12.5 tapered
x 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 373.5 438.45 163761.075
Partmm nominal
Rate Adminthickness
Block of approved size) on roofs jointed 0 0 0
Rate Amount Rate Amount
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 0 0
12.21 cm cementgola
Providing concrete
mm (1 in cement
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep aggregate 10 mm and down gauge),
chase metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 12.52 cast iron grating
Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 163761.075
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 558 255.55 142596.9
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 798 118.7 94722.6
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 798 71 56658
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
or more coats toon
even shade Sqm 0 78.4 0
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 558 150.65 84062.7
Distempering over andoil including
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New work (twobrandor more
and manufacture
coats) overtoand give an even shade
including water : Sqm 231 93.7 21644.7
Part priming Block
Rate Canteen coat with cement primer
11.09 13.50 Applying priming coat
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat)
13.68.1 Two or more coats on new works including a coat of wood filler Sqm
11.11 13.80 Providing and applying white cement based putty of average Sqm
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 39 1003.95 39154.05
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 103.5 62.45 6463.575
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved
Providing and quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators and partitions with extruded built up standard
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mmwith waterplaster
cement proofing
(iii) IIIrdsand) mixed
course with water
of applying blownproofing compound
or/residual bitumen inapplied
hot at 1.7 kg per sqm of area.
Rate Amount Rate Amount
(iv) IVth course of 400 micron thick PVC sheet (Overlaps cum 0 0 0
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 373.5 327.55 122339.925
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying andincluding preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
With a minimum period of of
average thickness two120weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 28.5 5583.8 159138.3
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
25 mm a 25thick
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 0 0
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 12 1801.53 21618.36
dado and pillars laid on 12 mm (average) thick cement 21618.36
SUB TOTAL (I) 4197321.75
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 88.82 13.95 1239.039
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 0 125.95 0
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 414.75 125.75 52154.8125
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 11.4 917.75 10462.35
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 347 51.75 17957.25
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
1:3:6 excluding
(1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 108102.2675
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
works uptomix M-25
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 21.83 7250.05 158268.5915
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically andbars
Treated binding all complete. Above Kg 5630.44 56.6 318682.904
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 67.93 422.3 28686.839
access platform
Rate Amount Rate Amount
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 47.6 342.9 16322.04
5.9.7 cantilevers
Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 26.35 467.85 12327.8475
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 26 193.95 5042.7
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering and shuttering
Add for using items)
extra cement in the items of design mix over and Quintal 24.94 672.75 16778.385
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 0 0
plinth and string courses etc. 589641.1165
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 6.35 4751.65 30172.9775
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
Cement (nonmortarmodular)
1:4 (1 cementbricks:4 of class
coarse designation 7.5
sand) Sqm 0 0 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 0 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 49 5687.1 278667.9
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 14.375 6818.6 98017.375
Substitute Diff Item No 6.13.2 & 6.15to 6.239* 0 0 0
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with 0 0 0
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3 0 0 0
7.38.1.1 Granite stone of any colour and shade Sqm 0 0 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 0 0
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 7 3113.3 21793.1
6.02 8.5 Extra for providing opening of required size & shape for each 8 427.95 3423.6
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 15 266.25 3993.75
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 46 306.25 14087.5
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 0 0 0
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required designgranite
Flamed finish and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 84425.75
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 0.14 92743.05 12984.027
Part Rate T Qtr 90 Sqm 0.86 13911.46 11963.8556
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 16 212.45 3399.2
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 8 88.1 704.8
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 40 51.1 2044
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper ISI marked
a) Twin rubber stopper anodised (anodic coating not less than Each 20 38 760
Rate Amount Rate Amount
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 20 622.15 12443
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked withhighsix leverslaminated
pressure and a pairsheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 76 837.4 63642.4
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 120 118.6 14232
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 24 19.15 459.6
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 115 conforming to IS : 363 with necessary screws etc. each 24 20.3 487.2
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
type of flush or
9.24.1 Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
Float glassor panes 0 0 0
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 0 0 0
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 251 113.6 28513.6
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required size M.S.
80x1.20 mm M.S. laths
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Academic Block 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 69 744.8 51391.2
Rate Admin 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 185 688.35 127344.75
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
40 graded stone
thick with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicate false
a Perimeter wallceiling
angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000 mm
false ceiling at all madeincluding
height of 0.40 mm 0 0 0
providing and fixing
1200 mm centre of frame
to centre, onework made
flange fixedofto special sections,
the ceiling with 0 0 0
dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts,
Rate Amount Rate Amount
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 291 438.45 127588.95
Part Ratenominal
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 0 0
12.21 cm cementgola
Providing concrete
mm (1 in cement
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep aggregate 10 mm and down gauge),
chase metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
Main595x595 mm to
"T" runners in be
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 127588.95
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 36.22 255.55 9256.021
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 930 118.7 110391
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 930 71 66030
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 0 0 0
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 342 150.65 51522.3
Distempering over andoil including
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New work (twobrandor more
and manufacture
coats) overtoand give an even shade
including water : Sqm 185 93.7 17334.5
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 23 1003.95 23090.85
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 66 62.45 4121.7
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
Providinghandle bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
vertical and horizontal surfaces of depressed portions of
Rate Amount Rate Amount
(i) Ist course of applying cement slurry @
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 32.99 327.55 10805.8745
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo 100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120 weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 22 5583.8 122843.6
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layer on of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 0 0
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 18 1801.53 32427.54
dado and pillars laid on 12 mm (average) thick cement 32427.54
SUB TOTAL (J) 2284650.512
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 255.08 13.95 3558.366
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 102.34 125.95 12889.723
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 479.77 125.75 60331.0775
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 37.69 917.75 34589.9975
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 185.95 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 0 51.75 0
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 2 6547.7 13095.4
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 0 193.95 0
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 229497.814
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
works uptomix M-25
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 90.49 7250.05 656057.0245
3.03 5.22 Reinforcement for RCC work including straightening, -41824.2 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically andbars
Treated binding all complete. Above Kg 10191.83 56.6 576857.578
Rate Amount Rate Amount
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 376.94 422.3 159181.762
Part Rateplatform
Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 215.2 342.9 73792.08
Part Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 183.2 467.85 85710.12
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 46 193.95 8921.7
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 91.32 672.75 61435.53
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 0 0
plinth and string courses etc. 1677511.766
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortar modular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular)
1:4 (1 cementbricks:4 of class
coarse designation 7.5
sand) Sqm 0 0 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 0 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 92 5687.1 523213.2
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 48.07 6818.6 327770.102
Substitute Diff Item No 6.13.2 & 6.15to 6.239* 0 0 0
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3 0 0 0
7.38.1.1 Granite stone of any colour and shade Sqm 0 0 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 0 0
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 18 3113.3 56039.4
6.02 8.5 Extra for providing opening of required size & shape for each 12 427.95 5135.4
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 42 266.25 11182.5
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 46 306.25 14087.5
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,
Granite ofpremoulded and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 0 0 0
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required designgranite
Flamed finish and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 127572.6
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 4 92743.05 370972.2
Part Rate Admin Block 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Amenities 0 0 0
Part Rate Boys Hostel 0 0 0
Part Rate Girls Hostel 0 0 0
Part Rate T Qtr 90 Sqm 0 0 0
Rate Amount Rate Amount
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
Part necessary
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 48 212.45 10197.6
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 24 88.1 2114.4
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 88 51.1 4496.8
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 44 38 1672
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 44 622.15 27374.6
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked withhighsix leverslaminated
pressure and a pairsheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 176 837.4 147382.4
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 264 118.6 31310.4
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 88 19.15 1685.2
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 115 conforming to IS : 363 with necessary screws etc. each 88 20.3 1786.4
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
type of flush or
9.24.1 Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 Float glassor panes 0 0 0
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 0 0 0
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 936 113.6 106329.6
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required size M.S.
80x1.20 mm M.S. laths
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 272 744.8 202585.6
Part Rate Adminto IS: 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 2 1238.2 2476.4
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed
floor thick cement
tiles of size Sqm 450 688.35 309757.5
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part (thickness
Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
Rate Amount Rate Amount
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
40 graded stone
thick with aggregate) finished
20 mm nominal sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicatea Perimeter false
angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with 0 0 0
mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 720 438.45 315684
Part Ratenominal
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 0 0
12.21 cm cementgola
Providing concrete
mm (1 in cement
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 315684
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 249.97 255.55 63879.8335
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarse of 2sand)
thickness Sqm 1598 118.7 189682.6
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 1598 71 113458
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 0 0 0
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 442 150.65 66587.3
Distempering over andoil including
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New work (twobrandor moreand manufacture
coats) overtoand give an even shade
including water : Sqm 474 93.7 44413.8
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the 0 0 0
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness andglasspartitions
mmEPDM rubber / Sqm 86 1003.95 86339.7
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 242 62.45 15112.9
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
includingfastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle bar including
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shade accordingofto doors,
For shutters IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
providing and fixing hinges/ pivots and making provision for
Rate Amount Rate Amount
21.1.2.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868, Minimum
8 mm anodic coating of grade
thickness 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith
15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
vertical and horizontal
(i) Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 0 0 0
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 49.01 327.55 16053.2255
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo 100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120 weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 54 5583.8 301525.2
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layer on of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 0 0
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 40 1801.53 72061.2
dado and pillars laid on 12 mm (average) thick cement 72061.2
SUB TOTAL (K) 6564096.025
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 90.3 13.95 1259.685
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 75.05 125.95 9452.5475
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 290 125.75 36467.5
1.04 1.1.2 plinth,
of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
20cm in Cum 0 0 0
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 43 917.75 39463.25
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 42 185.95 7809.9
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 335 51.75 17336.25
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade excluding
1:4:8 (1 Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
proofing 10 47.95 479.5
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 13.83 193.95 2682.3285
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 199271.954
Rate Amount Rate Amount
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
works uptomix M-25
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 75 7250.05 543753.75
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 3269.98 56.6 185080.868
Part Rate Head's quarter 7855.02 5.66 44459.4132
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically Treated andbars
binding all complete. Above Kg 8923 56.6 505041.8
Part Rate Admin Block Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Head's quarter Kg 0 0 0
Part Rate T Qtr 60 Sqm Kg 0 0 0
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 337 422.3 142315.1
Part Rateplatform
Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 305 342.9 104584.5
Part Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 138.17 467.85 64642.8345
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 9 193.95 1745.55
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 80 122.2 9776
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 29 93.57 2713.53
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 83.82 672.75 56389.905
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm
plinth and string courses etc. 1783409.466
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 16 4751.65 76026.4
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 0 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortar modular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular)
1:4 (1 cementbricks:4 of class
coarse designation 7.5
sand) Sqm 0 0 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 0 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 32 5687.1 181987.2
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 9.2 6818.6 62731.12
Substitute Diff Item No 6.13.2 & 6.15to 6.239*
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 0 1796.65 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut
8.2.2.2 Area of slab over 0.50 sum. Sqm 5 3113.3 15566.5
6.02 8.5 Extra for providing opening of required size & shape for each 4 427.95 1711.8
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 10 266.25 2662.5
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 28 306.25 8575
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
polished, premoulded and prepolished, machine cut for kitchen
Rate Amount Rate Amount
8.2.2 Granite of any colour and shade 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 0 0 0
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 54955.1
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 1 92743.05 92743.05
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
7.03 9.96 with necessary
Providing and screws
fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 16 212.45 3399.2
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 8 88.1 704.8
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 24 51.1 1226.4
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 15 38 570
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 10 622.15 6221.5
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked withhighsix leverslaminated
pressure and a pairsheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 48 837.4 40195.2
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 60 118.6 7116
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 42 19.15 804.3
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 115 conforming to IS : 363 with necessary screws etc. each 42 20.3 852.6
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
type of flush or
9.24.1 Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 Float glassor panes 0 0 0
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work, 0 0 0
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 0 0 0
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 387 113.6 43963.2
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm 0 0 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 0 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 66 744.8 49156.8
9.03 11.26 conforming
Kota stone toslab
15622 (thickness
over 20 mm to (average)
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
dado and pillars laid on 12 mm (average) thick cement
Rate Amount Rate Amount
11.37 Providing and laying Ceramic glazed floor tiles of size Sqm 181 688.35 124591.35
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
New 11.3 mm (thickness
Cement to beflooring
concrete specified1:2:4
by the(1manufacturer), of 1st sand
cement : 2 coarse 0 0 0
40 graded stone
thick with aggregate)
20 mm nominal finished
sizewith a floating
aggregate Sqm 0 0 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
resting light walls/partitions
on periphery weight calciumonsilicatea Perimeter false
angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 312 438.45 136796.4
12.22 20 mm nominal
Making thicknesswith
khurra 45x45cm of approved size) on roofs
average minimum jointedof 5
thickness Each 0 0 0
12.21 cm cementgola
Providing concrete
mm (1 in cement
cement :concrete
sand (1: 4cement
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 136796.4
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
13.4.2 1:6 (1 cement : 6 coarse sand) Sqm 300 168.25 50475
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 224 255.55 57243.2
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarse of 2sand)
thickness Sqm 300 118.7 35610
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 300 71 21300
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 0 0 0
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 224 150.65 33745.6
Distempering over andoil including
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New work (twobrandor moreand manufacture
coats) overtoand give an even shade
including water : Sqm 181 93.7 16959.7
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness andglasspartitions
mmEPDM rubber / Sqm 36 1003.95 36142.2
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 108 62.45 6744.6
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
includingfastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle bar including
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
ventilators and partitions with extruded built up standard
Rate Amount Rate Amount
21.1.1 For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868, Minimum
8 mm anodic coating of grade
thickness 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith
15SS screws etc. complete as per direction of
) aluminium 0 0 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
of 20mm with waterplaster
cement proofing
cement : 3 0 0 0
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied 0 0 0
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 0 0 0
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 312 327.55 102195.6
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) The whole mortarterrace
of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120 weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 24 5583.8 134011.2
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 0 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 0 0 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 0 0
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 6 1801.53 10809.18
dado and pillars laid on 12 mm (average) thick cement 10809.18
SUB TOTAL (L) 3583471.252
RECREATION BLOCK
2.0 EARTH WORK
2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 0 13.95 0
2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 0 125.95 0
2.25 Filling available excavated earth (excluding rock) in trenches, Cum 0 125.75 0
1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
20cm in Cum 0 0 0
2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 0 0 0
2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 0 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 0 51.75 0
5.0 R.C.C. WORK
5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 0 56.6 0
5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically Treatedandbars
binding all complete. Above Kg 0 0 0
SUB TOTAL (M) 0
GATE & GUARD ROOM
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
vegetation and in-equalities not exceeding 15 cm deep and
Rate Amount Rate Amount
2.28.1 All kinds of soil. Sqm 200 13.95 2790
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 537 125.95 67635.15
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 471 125.75 59228.25
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 10 917.75 9177.5
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 40 185.95 7438
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 455.19 51.75 23556.0825
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
plinth Sqm 0 450.35 0
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
proofing 10 47.95 479.5
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 25 193.95 4848.75
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 4814.55 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 5481.95 0
aggregate 20 mm nominal size). 127653.4
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
All worksdesign
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 80 7250.05 580004
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 8733 56.6 494287.8
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
bending, placing in position
5.22A.6 Thermo-Mechanically Treated andbars
binding all complete. Above Kg 7960 56.6 450536
Part Rate Admin Block Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Head's quarter Kg 0 0 0
Part Rate T Qtr 60 Sqm Kg 0 0 0
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
Foundation,of form for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 188 422.3 79392.4
Part Rateplatform
Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 340 342.9 116586
Part Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 0 419.35 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 65 467.85 30410.25
5.9.4 Shelves Sqm 0 422.3 0
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 0 193.95 0
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 92 122.2 11242.4
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 93.57 0
3.06 5.35 centering
Add and shuttering
for using extra cementitems)
in the items of design mix over and Quintal 151.2 672.75 101719.8
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
5.9.2 area to(any
Walls be measured)
thickness) including attached pilasters, butteresses, Sqm 0 378.6 0
plinth and string courses etc. 2659250.7
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular)
a) Cementof class
mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 5 4751.65 23758.25
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 5582.85 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
sand) Sqm 0 593.5 0
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
F.P.S. (non modular) bricks of class designation 7.5
Rate Amount Rate Amount
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 0 684.2 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 56.85 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 143 5687.1 813255.3
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 0 6818.6 0
Substitute Diff Item No 6.13.2 & 6.15to 6.239* 0 0 0
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3 0 0 0
7.38.1.1 Granite stone of any colour and shade Sqm 0 1796.65 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 521.1 0
6.00 8.0 MARBLE WORK
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut 0 0 0
8.2.2.2 Area of slab over 0.50 sum. Sqm 3 3113.3 9339.9
6.02 8.5 Extra for providing opening of required size & shape for each 0 427.95 0
6.03 8.4 wash basin/kitchen
Extra for fixing marblesink/granite
stone,platform,
above metre 0 266.25 0
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 2831.95 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 0 306.25 0
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 245.7 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 5 3351.95 16759.75
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 2887.85 0
Brown, Cat Eye or equivalent. 26099.65
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 0.100994 92743.05 9366.468406
Part Rate Admin Block 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Amenities 0 0 0
Part Rate Boys Hostel 0 0 0
Part Rate Girls Hostel 0 0 0
Part Rate T Qtr 90 Sqm 0 0 0
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
Part necessary
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 4 212.45 849.8
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 2 88.1 176.2
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
9.100.1 anodised
125 mm (anodic coating not less than grade AC 10 as Each 4 51.1 204.4
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 2 38 76
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 2 622.15 1244.3
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked with
highsix leverslaminated
pressure and a pair
sheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 14 837.4 11723.6
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 16 118.6 1897.6
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 2488.95 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 0 19.15 0
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
115 mm conforming to IS : 363 with necessary screws etc. each 0 20.3 0
Rate Amount Rate Amount
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 type)mm
300 with necessary
weighing notscrews etc.200
less than complete.
gms each 0 30.95 0
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 365.85 0
9.24 mm minimum
Extra depthvision
for providing on allpanel
edgesnotof flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
9.24.1 type of flush or
Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 162.6 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 panelled
Float or panes
9.7.7.2 5.5 mm thick glass panes Sqm 0 1456.8 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 472.4 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 0 113.6 0
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 355.2 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm 0 1841.4 0
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 2870.25 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 74.75 0
10.7 Providing and fixing ball bearing for rolling shutters. each 0 379.3 0
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 1119.4 0
Part Rate Admin Block 0 0 0
Part Rate Academic Block 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 1135.2 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 0 744.8 0
Rate Admin 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 1158.1 0
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 1238.2 0
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 63 688.35 43366.05
11.31 300x300 mmfinished
Extra for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 84.85 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 306.25 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 747.9 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
40 graded stone
thick with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 0 362.6 0
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged 0 0 0
resting light walls/partitions
on periphery weight calciumonsilicate
a Perimeterfalse
angle Sqm 0 1497.9 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at allmm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework made
flange fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 958.65 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 188 438.45 82428.6
Rate Adminthickness
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 187.6 0
12.21 cm cementgola
Providing concrete
cement :concrete
graded : 0 0 0
12.21.1 2 coarse
In 75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 153 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 40.9 0
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
plasterboard having glass fibre conforming to IS: 2095 part I, of 82428.6
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
13.4.2 1:6 (1 cement : 6 coarse sand) Sqm 588 168.25 98931
11.02 13.16 6 mm cement plaster of mix: 0 0 0
Rate Amount Rate Amount
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 417 255.55 106564.35
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarseof 2sand)
thickness Sqm 0 118.7 0
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 775 71 55025
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 200 78.4 15680
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 417 150.65 62821.05
Distempering over and
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New brandor more
work (two and manufacture
coats) overtoand give an even shade
including water : Sqm 0 93.7 0
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 15.6 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 209.75 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 87.35 0
thickness 1 mm, of approved brand and manufacturer, over the
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 528 444.9 234907.2
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 48 1003.95 48189.6
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 88 62.45 5495.6
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 359 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 55.5 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 68.3 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 384.5 0
21.18 coating 50and
Providing micron)
fixing 12 mm thick frameless toughened glass Sqm 0 4608.85 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 509.3 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 1323.1 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 355 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 415.05 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 1153.9 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 62.5 0
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of
(ii) IInd coursemixed
of 20mm with waterplaster
cement proofing
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing compound
or/residual bitumen inapplied 0 0 0
(iv) 1.7course
IVth kg perofsqm400 ofmicron
area. thick PVC sheet (Overlaps cum 0 505.9 0
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 188 327.55 61579.4
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry ofcoatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed
surfacewithwith
20mm thick waterjoint proofing
e) The wholemortarterrace
of mix 1:4 (1 cement
so finished : 4flooded
shall be coarse sand)
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120weeks
mm forandcuring
minimum and thickness
for final Sqm 0 1034.65 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 15 5583.8 83757
Providingaggregate 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
proofing on horizontal surface at all depth below ground level
Rate Amount Rate Amount
i) Ist layer of 22 mm to 25 mm thick approved and specified 0 0 0
25 mm a 25thick
cement of cement
mortar 1:3 (1mortar 1:33
cement: 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using size kota
rough spreading
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 0 1017.55 0
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 0 1253.3 0
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide,expansion joints
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 362.6 0
14.02 MR dry brickstone
Granite aggregate ofmm
thickthick nominal
in risers size including
of steps, skirting, Sqm 0 1801.53 0
dado and pillars laid on 12 mm (average) thick cement 0
SUB TOTAL (N) 4919093.321
UGT, DG & OTHER FOUNDATION
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in-equalities not exceeding 15 cm deep and Sqm 75 13.95 1046.25
1.02 2.6 Earthwork in excavation by mechanical means (Hydraulic 0 0 0
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30cm in depth, Cum 1030 125.95 129728.5
1.03 2.25 Filling available excavated earth (excluding rock) in trenches, Cum 248 125.75 31186
1.04 1.1.2 plinth, sides
Disposal of of foundations
surplus earth etc. in layers nottransport
by mechanical exceedingincluding
1.05 2.27 loading, unloading
Supplying and fillingfor a lead with
in plinth upto sand
Km. floors, including Cum 5 917.75 4588.75
1.06 2.34 watering, ramming,
Supplying chemicalconsolidating
emulsion in andsealed
dressing complete.
containers 0 0 0
2.34.1 including delivery asLindane
Chlorpyriphos/ specified. emulsifiable concentrate of Litre 0 0 0
Diluting and injecting chemical emulsion for 0 0 0
2.35.3 POSTCONSTRUCTIONAL
Treatment anti-termite
of soil under existing floors treatmentemulsion
using chemical 0 0 0
2.35.3.1 @ oneChlorpyriphos/Lindane
With litre per hole, 300 mm apart
20% withdrilling
1.09 2.26 concentration
Extra for every additional lift of 1.5 m or part thereof in 0 0 0
2.26.1 excavation
All kinds of/banking
soil excavated or stacked materials. cum 445 51.75 23028.75
2.00 4.0 CONCRETE WORK
2.01 4.1 Providing and laying in position cement concrete of specified
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering and shuttering
(zone-III) : 8 graded -stone
2.02 4.2 aggregate 40
Providing andmm nominal
laying size) concrete in retaining walls,
cement 0 0 0
4.2.3 return(1walls,
1:2:4 Cementwalls (anysand
: 2 coarse thickness) including
: 4 graded attached
stone aggregate 20 Cum 1 6547.7 6547.7
2.03 4.17 mm nominal
Making size)protection 50mm thick of cement concrete
plinth Sqm 0 0 0
Providing and : laying
3 coarsedamp-proof
sand : 6 graded
2.05 4.12 with cement
Extra concrete 1:2:4
for providing and (1mixing
2 coarse sand (zone- Per 50 kg
proofing 2 47.95 95.9
2.06 4.13 material in &cement
Providing concrete
applying workofin residual
a coat doses petroleum
by weight of cement
2.07 4.3 bitumen of and
Centering gradeshuttering
of VG-10including
of approved qualitypropping
strutting, using etc. 0 0 0
4.3.1 and removal footing,
Foundation, of form bases
for : of columns etc. Sqm 40 193.95 7758
2.08 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.6 grade excluding
1:3:6 (1 Cementthe: cost of centering
3 coarse and shuttering
sand (zone-III): - All work
6 graded stone Cum 0 0 0
New 4.1.3 aggregate
1:2:4 40 mm: 2nominal
(1 cement size).(zone-III) : 4 graded stone
coarse sand Cum 0 0 0
aggregate 20 mm nominal size). 213570.2
3.00 5.0 R.C.C. WORK
5.33 Providing and laying in position machine batched and machine
works uptomix M-25
Plinth grade cement concrete for reinforced
3.02 5.33.2 All works above plinth level upto floor V level Cum 11 7250.05 79750.55
3.03 5.22 Reinforcement for RCC work including straightening, 0 0 0
5.22.6 cutting, bending, placing
Thermo-Mechanically in position
Treated bars and binding all Kg 18503 56.6 1047269.8
3.04 5.22A Reinforcement for RCC work including straightening, cutting, 0 0 0
5.22A.6 bending, placing in position
Thermo-Mechanically andbars
Treated binding all complete. Above Kg 982 56.6 55581.2
Part Rate Admin Block Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Guest House Kg 0 0 0
Part Rate Head's quarter Kg 0 0 0
Part Rate T Qtr 60 Sqm Kg 0 0 0
3.05 5.9 Centering and shuttering including strutting, propping etc. and 0 0 0
5.9.1 removal of form
Foundation, for : bases of columns etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies, and Sqm 199 422.3 84037.7
Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.5 Lintels, beams, plinth beams, girders, bressumers and Sqm 52 342.9 17830.8
Part Rate Girls Hostel 0 0 0
Part Rate Guest House 0 0 0
5.9.7 Stairs, (excluding landings) except spiral- staircases. Sqm 0 0 0
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 46 467.85 21521.1
Rate Amount Rate Amount
5.9.4 Shelves Sqm 0 0 0
5.9.15 Small lintels not exceeding 1.5 m clear span, moulding Sqm 0 0 0
5.9.16 as in cornices,
Edges of slabswindow sills, string
and breaks courses,
in floors bands, copings,
and walls 0 0 0
5.9.16.1 Under 20 cm wide metre 219 122.2 26761.8
5.9.14 Extra for shuttering in circular work (20% of respective Sqm 0 0 0
3.06 5.35 centering
Add and shuttering
for using items)
extra cement in the items of design mix over and Quintal 195.3 672.75 131388.075
3.07 above for
5.11 Extra theadditional
specified cement
height incontent therein.
centering, shuttering where ever 0 0 0
5.11.1 required with
Suspended adequate
floors, roofs,bracing,
landing,propping
beams andetc., including
balconies cost of
thickness) including attached pilasters, butteresses, Sqm 788 378.6 298336.8
plinth and string courses etc. 3120482.375
4.00 6.0 BRICK WORK
4.01 6.1 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
a) Cementof class
mortardesignation
1:6 (1 cement : 6 coarse sand) Cum 9 4751.65 42764.85
4.02 6.4 Brick work with common burnt clay F.P.S. (non modular) 0 0 0
6.4.2 bricks ofmortar
Cement class designation
1:6 (1 cement : 6 coarse sand) Cum 0 0 0
4.03 6.12 Half brick masonry with common burnt clay 0 0 0
mortarmodular) bricks: 4 coarse
1:4 (1 cement of class designation 7.5 in
sand) Sqm 0 0 0
4.04 6.13 Half brick masonry with common burnt clay 0 0 0
6.13.2 F.P.S. (non
Cement mortarmodular)
1:4 (1 cementbricks:4 of class
coarse designation 7.5
sand) Sqm 0 0 0
4.05 6.15 Extra for providing and placing in position 2 Nos 6mm dia. Sqm 0 0 0
4.06 6.47 M.S. barsand
Providing at laying
everyautoclaved
third course of half
aerated brick blocks
cement masonry.
masonry 0 0 0
with 150mm/230mm/300 mm thick AAC blocks in super Cum 15 5687.1 85306.5
Substitute Diff Item No 6.4.2 to 6.47 0 0 0
4.07 6.38 Providing and laying autoclaved aerated cement blocks masonry 0 0 0
with 100 mm thick AAC blocks in super structure above plinth 0 0 0
level up to floor V level in cement mortar 1:4 (1 cement : 4 Cum 0 0 0
Substitute Diff Item No 6.13.2 & 6.15to 6.239* 0 0 0
5.00 7.0 STONE WORK
5.01 7.38 Stone tile work for wall lining upto 10 m height with
7.38.1 specialthick
(mirrorover 12 mm
polished and thick
edge) mortar 1:3
7.38.1.1 Granite stone of any colour and shade Sqm 0 0 0
7.25 Providing and fixing stainless steel cramps of required size and Kgs 0 0 0
shape for 0 0 0
6.00 8.0 MARBLE WORK 0 0 0
6.01 8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,of any
Granite premoulded
shadeprepolished, machine cut 0 0 0
8.2.2.2 Area of slab over 0.50 sum. Sqm 0 0 0
6.02 8.5 Extra for providing opening of required size & shape for each 0 0 0
6.03 8.4 wash for
Extra basin/kitchen
fixing marblesink/granite
stone,platform,
above metre 0 0 0
6.04 8.10 corresponding
Providing basicstone
and fixing item,slabinwith
width upto 0 0 0
8.10.2 roundedStone
Granite and polished, of size
of approved 75x50 cm deep and 1.8 cm thick,
shade Sqm 0 0 0
6.05 8.13 Providing and laying Polished Granite stone flooring in 0 0 0
8.13.1 required design
Polished Graniteand stone
patterns, in linear
slab as wellCherry
jet Black, as curvilinear
Red, Sqm 0 0 0
6.06 11.24 Elite Brown,
Extra Cat Eyenosing
for pre finished or equivalent.
to treads of steps of marble M 0 0 0
Providing edge moulding to 18 mm thick marble stone 0 0 0
8.3.2 counters,work
Granite Vanities etc., including machine polishing to edge to 0 0 0
8.2 Providing and fixing 18 mm thick gang saw cut, mirror 0 0 0
8.2.2 polished,ofpremoulded
Granite and shade
any colour and prepolished, machine cut for kitchen 0 0 0
8.2.2.1 Area of slab upto 0.50 sqm Sqm 2 3351.95 6703.9
8.12 Providing and laying flamed finish Granite stone flooring in 0 0 0
8.12.1 required finish
Flamed designgranite
and patterns, in linear
stone slab Jet as well Cherry
Black, as curvilinear
Red, Elite Sqm 0 0 0
Brown, Cat Eye or equivalent. 6703.9
7.00 9.0 WOOD WORK
7.01 9.1 Providing wood work in frames of doors, windows,
9.1.1 clerestory
Second classwindows
teak woodand other frames, wrought framed Cum 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Amenities 0 0 0
Part Rate Boys Hostel 0 0 0
Part Rate Girls Hostel 0 0 0
Part Rate T Qtr 90 Sqm 0 0 0
7.02 9.21 Providing and fixing ISI marked flush door shutters conforming 0 0 0
thick(Part I) nonISI
including decorative type, coreSteel
marked Stainless of block
hinges Sqm 0 0 0
Part necessary
7.03 9.96 Providing and fixing aluminium sliding door bolts ISI 0 0 0
9.96.1 marked mm
300x16 anodised (anodic coating not less than grade AC 10 as Each 0 0 0
7.04 9.97 Providing and fixing aluminium tower bolts ISI marked 0 0 0
9.97.2 anodisedmm
250x10 (anodic coating not less than grade AC 10 as per Each 0 0 0
7.05 9.100 Providing and fixing aluminium handle ISI marked 0 0 0
anodised (anodic coating not less than grade AC 10 as
Rate Amount Rate Amount
7.06 9.101 Providing and fixing aluminium hanging floor door 0 0 0
9.101.2 stopper
Twin rubber stopper anodised (anodic coating not less than Each 0 0 0
7.07 9.103 Providing and fixing bright finished brass 100mm mortice Each 0 0 0
7.08 9.127 latch and &
Providing lock ISI decorative
Fixing marked withhighsix leverslaminated
pressure and a pairsheet of 0 0 0
9.127.1 of plainthick
1.5mm / wood grain in gloss / matt / suede finish with high Sqm 0 0 0
Substitute Diff Item No 9.127.1 to 9.127.2 0 0 0
9.127.2 1.0mm thick Sqm 0 0 0
7.09 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including each 0 0 0
9.20 fixing to frame
Providing with 10
and fixing ISI mm diameter
marked flushbolts,
doornuts and wooden
shutters 0 0 0
9.20.1 conforming
35 mm thick to IS : 2202
including (Part I)Stainless
ISI marked decorative
Steeltype, core
butt hinges Sqm 0 0 0
7.10 9.40 with necessary
Providing screwswooden moulded beading to door and
and fixing 0 0 0
9.40.1 2nd classframes with iron screws, plugs and priming coat on
teak wood 0 0 0
9.66 Providing and fixing ISI marked oxidised M.S. handles 0 0 0
9.66.3 75 mm to IS:4992 with necessary screws etc. complete : each 2 19.15 38.3
9.67 Providing and fixing oxidised M.S. hasp and staple (safety 0 0 0
9.67.2 115 conforming to IS : 363 with necessary screws etc. each 2 20.3 40.6
9.68 Providing and fixing oxidised M.S. casement stays (straight peg 0 0 0
9.68.1 300 with necessary
weighing notscrews etc.200
less than complete.
9.23 Extra for providing lipping with 2nd class teak wood battens 25 Sqm 0 0 0
Extraminimum depthvision
for providing on allpanel
of flush door shutters
exceeding 0.1 sqm (over
in all all 0 0 0
type of flush or
9.24.1 Rectangular doors (cost of glass excluded) (overall area of door
square Sqm 0 0 0
9.7 Providing and fixing panelling or panelling and glazing in 0 0 0
9.7.7 Float glassor panes 0 0 0
9.7.7.2 5.5 mm thick glass panes Sqm 0 0 0
8.00 10.0 STEEL WORK
8.01 10.25 Steel work welded in built up sections/ framed work,
10.25.2 including
In gratings,cutting,hoisting,
frames, guardfixing bar, inladder,
position and applying
brackets, Kgs 0 0 0
8.02 10.28 gates and similar
Providing worksstainless steel ( Grade 304) railing made
and fixing 0 0 0
of Hollow tubes, channels, plates etc., including welding, Kgs 0 0 0
8.03 10.11 Providing and fixing factory made ISI marked steel 0 0 0
10.11.1 glazed doors,
Fixing windows
with 15x3 mmand ventilators,
lugs 10 cm side /top /centrein
long embedded Kgs 52.8 113.6 5998.08
8.04 cement concrete
21.1 Providing and fixingblock 15x10x10
aluminium work cm of C.C.
for doors, 1:3:6 (1
windows, 0 0 0
21.1.1 ventilators
For fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent Kgs 0 0 0
10.6 Supplying
or dyed to and fixingshade
required rollingaccording
IS: make, made of 0 0 0
10.6.2 required mm
80x1.20 size M.S.
1.20 mmtogether
thick topthrough
cover their Sqm 9 1841.4 16572.6
10.5 Providing and fixing 1mm thick M.S. sheet door with frame of 0 0 0
Using M.S.mm angle40x40x6
angles iron and mm
3 mmforM.S. gusset
diagonal plates at the
braces Sqm 0 0 0
10.27 Providing and fixing carbon steel galvanised ( minimum 0 0 0
10.27.2 coating
micron) dash fastener of 10 mm dia double threaded 0 0 0
10.7 Providing and fixing ball bearing for rolling shutters. each 2 379.3 758.6
9.00 11.0 FLOORING
9.01 11.41 Providing and laying vitrified floor tiles in different sizes
11.41.2 (thickness
Size of Tileto600x600
mm by the manufacturer) with water Sqm 0 0 0
Part Rate Admin Block 0 0 0
Part Rate Academic Block 0 0 0
11.46 Providing and laying Vitrified tiles in different sizes (thickness 0 0 0
11.46.2 to beof
Size specified by manufacturer),
Tile 600x600 mm with water absorption less Sqm 0 0 0
9.02 11.36 Providing and fixing Ist quality ceramic glazed wall tiles Sqm 445 744.8 331436
Rate Admin 15622 (thickness to be specified
9.03 11.26 Kota stone slab flooring over 20 mm (average) thick 0 0 0
25 mm laid over and jointed with grey cement slurry mixed
thick Sqm 0 0 0
Part Rate Admin Block 0 0 0
9.04 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, Sqm 0 0 0
11.37 dado and pillars
Providing laid Ceramic
and laying on 12 mmglazed(average)
floor thick cement
tiles of size Sqm 200 688.35 137670
Extra mmfinished
for pre (thickness to in
nosing betreads
specified by the
of steps of manufacturer)
Kota stone/ metre 0 0 0
11.24 sand stone
for pre finished nosing to treads of steps of marble stone. metre 0 0 0
9.05 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 Sqm 0 0 0
Part Rate Admin to Block
be specified by the manufacturer), of 1st 0 0 0
New 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand 0 0 0
40 graded stone
thick with aggregate)
20 mm nominalfinished
sizewith a floating
aggregate Sqm 54 362.6 19580.4
10.00 12.0 ROOFING
10.01 12.53 Providing and Fixing 15 mm thick densified tegular edged
eco friendly light weight calcium silicate false ceiling
Rate Amount Rate Amount
resting on periphery walls/partitions on a Perimeter wall angle Sqm 0 0 0
10.03 12.45 pre-coatedand
Providing steelfixing
of size(24x24X3000
false ceiling at all mm madeincluding
height of 0.40 mm 0 0 0
1200 and fixing
mm centre of frame
to centre, onework
fixedofto special sections,
the ceiling with 0 0 0
12.45.3 dash fastener
12.5 mm thick 12.5 tapered
mm diaedgex 50mm longmoisture
gypsum with 6mm dia bolts,
resistant board Sqm 0 0 0
10.04 12.20 Providing and laying pressed clay tiles (as per approved pattern Sqm 33 438.45 14468.85
Part Ratenominal
Block of approved size) on roofs jointed 0 0 0
12.22 Making khurra 45x45cm with average minimum thickness of 5 Each 0 0 0
12.21 cm cementgola
Providing concrete
mm (1 in cement
cement :concrete
sand (1: 4cement
graded : 0 0 0
75x75sand : 4 stone
mm deep chaseaggregate 10 mm and down gauge), metre 0 0 0
12.44 Providing and fixing to the inlet mouth of rain water pipe Each 0 0 0
10.05 cast iron grating
12.52 Providing and fixing 15 tiled
cm diameter andofweighing
false ceiling specifiednot less of
materials 0 0 0
"T" runners in be
horizontalfromlevel,ceiling
usingon GIinter
slotted 0 0 0
x 37 Perforated
x 25 x1.6 mm fixed to
Gypsum ceiling
Board tilewith
from Sqm 0 0 0
plasterboard having glass fibre conforming to IS: 2095 part I, of 14468.85
11.00 13.0 FINISHING
11.01 13.4 12 mm cement plaster of mix :
13.4.2 1:6 (1 cement : 6 coarse sand) Sqm 108 168.25 18171
11.02 13.16 6 mm cement plaster of mix: 0 0 0
11.03 13.11 18 mm cement plaster in two coats under layer 12 mm Sqm 108 255.55 27599.4
11.04 13.26 thick cement
Providing plaster 1:5
and applying (1 cement
plaster of paris: 5putty
coarse of 2sand)
thickness Sqm 0 0 0
over plastered
Substitute Diffsurface
prepare the surface even and
11.05 13.83 Wall painting with premium acrylic emulsion paint of interior 0 0 0
13.83.2 grade,coats
Two having VOC (Volatile Organic Compound ) content Sqm 141 71 10011
Part Rate Academic Block 0 0 0
Part Rate Canteen Block 0 0 0
11.06 13.61 Painting with synthetic enamel paint of approved brand 0 0 0
13.61.1 and manufacture
Two or more coats toon
even shade Sqm 0 0 0
11.07 13.45 Finishing walls with textured exterior paint of required shade : 0 0 0
13.45.1 New work (Two or more coats applied @ Sqm 108 150.65 16270.2
Distempering over andoil including
washable coat of exterior of
distemper 0 0 0
13.41.1 approved
New work (twobrandor moreand manufacture
coats) overtoand give an even shade
including water : Sqm 0 0 0
Part priming Block
Rate Canteen coat with cement primer 0 0 0
11.09 13.50 Applying priming coat 0 0 0
13.50.4 With ready mixed red oxide zinc chromate primer of approved Sqm 0 0 0
11.10 brand and
13.68 French manufacture
spirit polishing on steel work (second coat) 0 0 0
13.68.1 Two or more coats on new works including a coat of wood filler Sqm 0 0 0
11.11 13.80 Providing and applying white cement based putty of average Sqm 0 0 0
thickness 1 mm, of approved brand and manufacturer, over the 0 0 0
12.00 21.0 ALUMINIUM WORKS
12.01 21.1.2 For shutters of doors, windows & ventilators including
21.1.2.2 providing and
Powder coatedfixingaluminium
hinges/ pivots(minimum
and making provision
thickness of for Kgs 0 0 0
Part Ratecoating
Admin50Block micron) 0 0 0
Part Rate Academic Block 0 0 0
12.02 21.3 Providing and fixing glazing in aluminium door, window, 0 0 0
21.3.2 ventilator
With floatshutters
thickness and glasspartitions
mmEPDM rubber / Sqm 5 1003.95 5019.75
12.03 21.8 Filling the gap in between aluminium frame & adjacent 0 0 0
21.8.1 RCC/5mm
mm widthby providing weather silicon metre 11 62.45 686.95
12.04 21.13 Providing and fixing 100mm brass locks (best make of Each 0 0 0
12.05 21.15 approved and
Providing quality)
fixing for aluminiumcasement
aluminium doors windows
including fastener 0 0 0
21.15.2 of required
Powder lengthminimum
aluminium for aluminium windowscoated
50 thickness with micron
necessary Each 0 0 0
12.06 21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Powder with minimum
coated SS screwsthickness
etc. complete as per aluminium
50 micron direction of Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.2 Powder coated aluminium (minimum thickness of powder Kg 0 0 0
Providing 50and
fixing 12 mm thick frameless toughened glass Sqm 0 0 0
21.12 door shutter
Providing andoffixing
approved brand and
aluminium manufacture,
tubular handle barincluding
21.12.2 outer dia,
coated thick &thickness
minimum 2100 mm50 long with aluminium
micron SS screws etc Each 0 0 0
17.32 tubular handle
Providing bar mirror of superior glass (of approved
and fixing 0 0 0
17.32.4 quality) and of
Rectangular required
1500x450 and size with plastic moulded Each 0 0 0
21.1 Providing and fixing aluminium work for doors, windows, 0 0 0
21.1.1 ventilators
For and partitions with extruded built up standard
fixed portion 0 0 0
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required 0 0 0
21.1.2 shadeshutters
For accordingofto doors,
IS: 1868,windows
Minimum&anodic coating including
ventilators of grade 0 0 0
21.1.2.1 Anodised fixing hinges/
aluminium pivots
(anodised and making
transparent provision
to required 0 0 0
21.3.3 shadefloat
With according to IS: of
glass panes 1868,
thicknessanodic coating of grade 0 0 0
21.16 Providing and fixing aluminium round shape handle of outer 0 0 0
Anodized (ACwith15SS screws etc. complete as per direction of
) aluminium 0 0 0
Rate Amount Rate Amount
13.00 22.0 WATER PROOFING
13.01 22.3 Providing and laying water proofing treatment to 0 0 0
(i) and horizontal
Ist course surfaces
of applying of depressed
cement slurry @ portions of 0 0 0
of 20mm with waterplaster
cement proofing
cement : 3 0 0 0
(iii) IIIrdsand)
coursemixed with water
of applying blownproofing
or/residualcompound
bitumen inapplied 0 0 0
(iv) IVth1.7course
kg perofsqm 400 ofmicron
area. thick PVC sheet (Overlaps cum 0 0 0
13.02 22.22A at joints and
Providing of applying
PVC sheet fibreshould be 100mm
reinforced wide and
elastomeric liquidpasted Sqm 207 327.55 67802.85
13.03 22.7 water proofing
Providing membrane
and laying withcement
integral resilient acrylic
based waterpolymers having
proofing 0 0 0
a) Applying and including preparation
grouting a slurry of coatsurface
of neat as required
cement using 0 0 0
b) kg/sqm. of cement
cement admixed
concrete usingwith proprietary
broken water bats
bricks / brick 0 0 0
c) Aftertotwo100daysmm size with
of proper 50%applying
curing cement mortar
a second1:5coat(1 of 0 0 0
Finishing admixed withwith
surface proprietary
20mm thick waterjoint proofing
e) mortarterrace
The whole of mix 1:4 (1 cement
so finished shall be: 4flooded
with water 0 0 0
22.7.1 for a minimum
With period of of
average thickness two120 weeks
mm for andcuring
minimum and thickness
for final Sqm 0 0 0
13.04 22.14 at khurra roof
Grading as 65for
mm.water proofing treatment with 0 0 0
22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded Cum 16 5583.8 89340.8
22.1 stone aggregate
Providing 20 mm
and laying nominal
integral size)based treatment for water
cement 0 0 0
i) Ist layeron of
to 25 mm at allthick
depth below ground
approved level
and specified 0 0 0
(ii) 2ndstone slab
cement base of cement
mortar 1:3 (1mortar
cement:1:33 0 0 0
(iii) sand) mixed
Finishing with water
top with stone proofing
aggregatecompound
22.1.1 nominal
Using rough size kota
stone.@ 8 cudm/sqm thoroughly embedded in Sqm 286 1017.55 291019.3
22.2 Providing and laying integral cement based treatment for water 0 0 0
22.2.1 proofing
rough Kotavertical
stone surface by fixing specified stone slab Sqm 371 1253.3 464974.3
22.4 Providing and Placing in position suitable PVC water stops 0 0 0
22.4.2 conforming
Dumb to IS:12200
bell with for construction/
central bulb (180 mm wide, expansion joints
8 mm thick) 0 0 0
14.01 MR Providing and laying 250 mm thick compacted bed of Sqm 0 0 0
14.02 MR dry brickstone
Granite aggregate
thickthick nominal
in risers size including
of steps, skirting, Sqm 0 0 0
dado and pillars laid on 12 mm (average) thick cement 0
SUB TOTAL (O) 5339950.215
SANITARY & PLUMBING
1 17.3 Providing and fixing white vitreous china pedestal type water
17.3.1 closet pan
W.C. (European
with ISItype) withwhite
marked seat and
solidlid, 10 litre
plastic seatlow
lid white Each 102 4593.75 468562.5
2 17.7 Providing and fixing wash basin with C.I. brackets, 15 0 0 0
White brass China
Vitreous pillar Wash
taps, 32 mmsize
basin C.P.630x450
mm of standard
with a pair Each 96 2298.55 220660.8
Part mm C.P. brass pillar taps 40 655.08 26203.28
3 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) 0 0 0
17.10.1 Kitchen sink with
as per IS: Board
Drain 13983 with C.I. brackets and stainless 0 0 0
4 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin 0 0 0
17.28.2 Flexible P.V.C. waste fittings complete. 0 0 0
17.28.1 Semi rigid pipe 0 0 0
5 17.4 Providing and fixing white vitreous china flat back or wall 0 0 0
17.4.1 One type basin
430x260x350 mm and
automatic Each 11 3494.15 38435.65
Part Ratecistern 11 594.01 6534.11
6 17.31 Providing and fixing mirror of superior glass (of approved Each 117 817.95 95700.15
7 quality) complete
17.34 Providing with
and fixing 6 mm
paper hard board ground fixed to
holder 0 0 0
8 17.35 Providing and Fixing soil, waste and vent pipes 0 0 0
17.35.1.2 Centrifugally cast (spun) iron socketed pipe as per IS: 3989 M 1415 921.65 1304134.75
17.35.2.2 Centrifugally cast (spun) iron socketed pipe as per IS: 3989 M 307 794.55 243926.85
9 17.70 Providing and fixing PTMT Bottle Trap for Wash basin and 0 0 0
sink. trap 38 mm single piece moulded with height of 270
10 mm, effective
17.72 Providing and length
ring from the centre
trapezoidal of the
11 mm long, 200
17.73 Providing andmm widePTMT
fixing with minimum
towel raildistances
completeof 37 mm
17.73.2 600 fixedtowel
mm long to wooden
rail withcleats
lengthCPofbrass screws
645 mm, 78 with
12 wide and effective
17.60 Providing and Fixing height
selfmm, weighing
cleansing not with
design less than 190
screwed 0 0 0
17.60.2 100mm hinged
75 mmwith or without vent arm complete,
outlet 0 0 0
17.60.2.1 Sand cast iron S&S as per IS - 3989 Each 354 1072.8 379771.2
13 17.65 Painting sand cast iron/centrifugally cast (spun) iron soil, waste 0 0 0
17.65.1 a) pipes dia
100mm andmeter
fittings with paint of any colour such as
17.65.2 b) 75mm dia meter pipe M 307 31 9517
14 17.37 Providing and fixing MS holder-bat clamps of approved 0 0 0
design to Sand Cast iron/cast iron (spun) pipe embedded in
Rate Amount Rate Amount
17.37.2 For 75mm dia pipe Each 20 165.05 3301
15 17.38 Providing and fixing bend of required degree with access 0 0 0
door insertion rubber washer 3mm thick bolts and nuts
17.38.1.2 Sand Cast iron S&S as per IS-3989 Each 140 384.9 53886
17.38.2.2 Sand Cast iron S&S as per IS-3989 Each 40 317.85 12714
16 17.39 Providing and fixing plain bend of required degree 0 0 0
17.39.1.2 Sand Cast iron S&S as per IS-3989 Each 160 334.95 53592
17.39.2.2 Sand Cast iron S&S as per IS-3989 Each 60 248.2 14892
17 17.40 Providing and fixing heal rest sanitary bend 0 0 0
17.40.1.2 Sand Cast iron S&S as per IS-3989 Each 140 370.95 51933
17.40.2.2 Sand Cast iron S&S as per IS-3989 Each 40 312.05 12482
18 17.43 Providing and fixing single equal plain junction of required 0 0 0
degree with access
17.43.1 100x100x100 mm door, insertion rubber washer 3 mm thick, 0 0 0
17.43.1.2 Sand cast iron S&S as per IS - 3989 Each 120 623 74760
19 17.56 Providing and fixing terminal guard 0 0 0
17.56.1.2 Sand Cast iron S&S as per IS-3989 Each 160 333.8 53408
20 17.57 Providing and fixing collars 0 0 0
17.57.1.2 Sand Cast iron S&S as per IS-3989 Each 1572 351.2 552086.4
21 17.58 Providing lead caulked joints to sand cast 0 0 0
iron/centrifugally
17.58.1 a) 100mm cast (spun) iron pipes & fittings of dia Each 1382 309.95 428350.9
22 17.59 Providing and fixing MS stays and clamps for sand cast iron/ 0 0 0
centrifugally cast (spun) iron pipes of diameter.
23 18.49 Providing and fixing C.P. brass bib cock of approved quality to 0 0 0
18.49.1 15 mm nominal to ISbore
24 18.51 Providing and fixing C.P. brass long body bib cock of 0 0 0
18.51.1 15 qualitybore
mm nominal conforming to IS standards and weighing not Each 20 492.55 9851
25 18.52 Providing and fixing C.P. brass stop cock (concealed) of 0 0 0
18.52.1 15 design and
mm nominal boreof approved make conforming to IS : 8931. Each 127 545.95 69335.65
26 18.53 Providing and fixing C.P. brass angle valve for basin mixer and 0 0 0
18.53.1 15 mmpoints
nominal of approved
bore quality conforming to IS : 8931 Each 508 475.7 241655.6
27 18.65 Providing and fixing PTMT soap Dish Holder having length of Each 115 112.3 12914.5
28 138mm, breadth
17.61 Cutting chases 102mm,
in brickheight of 75mm
masonry wallswith
following 0 0 0
17.61.1 diameter
100 mm dia sand cast iron/centrifugally cast (spun) iron pipes M 424.5621 355.7 151016.739
29 18.76 Cutting holes upto 30 X 30 cm in walls including making good 0 0 0
18.76.1 With common burnt clay F.P.S. (non modular) bricks Each 94 219.2 20604.8
30 18.78 Making chases upto 7.5 X 7.5 cm in walls including making M 100 93.85 9385
good afterwork
Internal housing
- Exposed on wall 0 0 0
18.7.2 20mm nominal outer dia pipes M 42 179.95 7557.9
18.7.3 25mm nominal outer dia pipes M 896 216.2 193715.2
18.7.4 32mm nominal outer dia pipes M 1173.66 289.05 339246.423
18.7.5 40mm nominal outer dia pipes M 60.85 385.5 23457.675
18.7.6 50mm nominal outer dia pipes M 48 548.55 26330.4
32 18.8 Providing and fixing Chlorinated Polyvinyl Chloride 0 0 0
Concealed workhaving thermal
including stability
cutting for and
chases hot & cold water
making good 0 0 0
etc., outer dia pipes M 701 246.2 172586.2
18.8.2 20mm nominal outer dia pipes M 451.4 284.85 128581.29
18.8.3 25mm nominal outer dia pipes M 0 333.6 0
18.8.4 32mm nominal outer dia pipes M 23.2 412.9 9579.28
32 18.9 Providing and fixing Chlorinated Polyvinyl Chloride 0 0 0
External pipes,
work having thermal stability for hot & cold water 0 0 0
18.9.5 40mm nominal outer dia pipes M 0 0 0
18.9.6 50mm nominal outer dia pipes M 100 484.25 48425
18.9.7 62.5mm nominal outer dia pipes M 400 1081.75 432700
18.9.8 75mm nominal outer dia pipes M 400 1201.05 480420
33 18.17 Providing and fixing gun metal gate valve with C.I. Wheel of 0 0 0
18.17.1 25 mm dia. quality
nominal(screwed
bore end). Each 80 428.2 34256
18.17.2 32 mm dia. nominal bore Each 80 500.75 40060
18.17.3 40 mm dia. nominal bore Each 60 584.7 35082
18.17.4 50 mm dia. nominal bore Each 40 749.9 29996
18.17.5 65 mm dia. nominal bore Each 20 1286.8 25736
18.17.6 80 mm dia. nominal bore Each 10 1919.5 19195
34 18.18 Providing and fixing ball valve (brass) of approved 0 0 0
18.18.3 quality, High or
25 mm nominal borelow pressure,with plastic floats complete : Each 75 331.95 24896.25
Rate Amount Rate Amount
35 18.19 Providing and fixing gun metal non-return valve of approved 0 0 0
18.19.4 32 mm (screwed end).
nominal bore 0 0 0
36 18.21 Providing and fixing unplasticised PVC connection pipe with 0 0 0
18.21.1 30 cmunions.
length 0 0 0
18.21.1.1 15 mm nominal bore Each 300 59.4 17820
37 18.22 Providing and fixing C.P. brass shower rose with 15mm or 0 0 0
38 18.48 Providing and placing on terrace (at all floor levels) Litre 22500 7.25 163125
part rate water storage tank ISI : 12701 marked indicating 37500 1.60 60020
40 2.10 Excavating trenches of required width for pipes, cables, etc 0 0 0
2.10.1 All kinds of soil 0 0 0
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 M 1340 225.45 302103
41 19.4 mm dia. and fixing square-mouth S.W. gully trap grade 'A'
Providing 0 0 0
P type brick masonry chamber with water 0 0 0
19.4.1.2 With Sewer bricks conforming to IS : 4885 Each 232 1619.55 375735.6
42 19.7 Constructing brick masonry manhole in cement mortar 1:4 0 0 0
19.7.1 Inside size 90: 4Xcoarse
cm deep topincluding
covermix 0 0 0
19.7.1.2 With Sewer (light
bricks duty) 455 Xto610
conforming mm internal
19.7.3 Inside size 120 X 90 cm and 90 cm deep including C.I. 0 0 0
19.7.3.2 With with frame
bricks(medium duty)to500
conforming IS : mm
4885internal diameter, Each 1 23088.6 23088.6
43 19.8 Extra for depth of manholes 0 0 0
19.8.1.2 With Sewer bricks conforming to IS : 4885 Meter 140 5848.95 818853
19.8.2.2 With Sewer bricks conforming to IS : 4885 Meter 1 7006.1 7006.1
44 19.27 Constructing brick masonry road gully chamber 50 X 45 X 60 0 0 0
19.27.1 With bricks
F.P.S. of class designation 75 in cement mortar 1:4 (1
45 19.32 Making soak pit 2.5 m diameter 3.0 m deep with 45 X 45 cm 0 0 0
19.32.1 With honey burnt
common comb clay
with bricks of class bricks
(non modular) designation
47 class designation
12.41 Providing 7.5 on wall face unplasticised Rigid
and Fixing 0 0 0
12.41.2 110 raindiameter
water pipes conforming to IS : 13592 Type A, Metre 204.81 236.35 48406.8435
49 12.42 Providing and Fixing on wall face unplasticised PVC 0 0 0
moulded fittings/ accessories for unplasticized Rigid PVC
12.42.6 Shoe (Plain) 0 0 0
50 12.43 Providing and fixing unplasticised PVC pipe clips of 0 0 0
approved design to unplasticized PVC rain water pipes by
51 12.44 Providing and fixing to the inlet mouth of rain water pipe cast Each 128 40.9 5235.2
52 19.6 iron gratingand
Providing 15 cm diameter
laying and weighing
non-pressure NP2 not less(light
class than 440
19.6.3 250 mmpipes with collars
dia. R.C.C. pipe jointed with stiff mixture of meter 10 482.05 4820.5
19.6.7 600 mm dia. R.C.C. pipe meter 0 0 0
53 8.10 Providing and fixing stone slab table rubbed,edges rounded 0 0 0
8.10.2 Granite stone ofofapproved
shadedeep and 1.8cm thick fixed in Sqm 3.75 2831.95 10619.8125
57.1 23.1 Boring/drilling bore well of required dia for casing/ 0 0 0
23.1.1 All typespipe,
of soilby suitable method prescribed in IS: 2800 0 0 0
57.2 23.3 Supplying, assembling, lowering and fixing in vertical 0 0 0
23.3.1 150 in bore well, unplasticized PVC medium well casing
mm dia Meter 30 289.85 8695.5
57.3 23.4 Supplying, assembling, lowering and fixing in vertical 0 0 0
a). 23.4.1 position
100 mmindiabore well unplasticized PVC medium well screen Meter 20 448.05 8961
57.4 23.8 Gravel packing in tubewell construction in accordance with IS: Cum 6 1175.6 7053.6
57.4 23.12 4097, including
Development of providing gravel
tube well in fine/ medium/
accordance with IS coarse, in I)
23.13 Providing to establish
and fixing suitablemaximum rate mild
size threaded of usable
a). 23.13.2 spot welded
150mm dia plate to the top of bore well housing/ casing pipe, Each 2 182.95 365.9
57.6 23.14 Providing and fixing M.S. clamp of required dia to the top of 0 0 0
a). casing / dia
23.14.2 150mm housing pipe of tubewell as per IS: 2800 (part I), Each 2 1017.7 2035.4
57.11 18.17 Providing & fixing gun metal gate valve with C.I wheel 0 0 0
i). 18.17.4 of50 approved
mm dia Quality (screwed end): Each 2 749.9 1499.8
57.12 18.19 Providing & fixing gun metal non-return valve of approved 0 0 0
18.19.4 50 (screwedbore
mm nominal end): 0 0 0
39 MR Providing & fixing C.P. brass shower assembly consisting of Each 93 3540.46 329262.78
46 MR wallfeeding
For mixer (Jaquar model no. CON-281KN),
Domestic/Flushing water to entirewith wall Variable
Project. flanges 0
(a) Speed-Location
Capacity 1 LPS each minimum 0
Head 10 Mts. 0
Rate Amount Rate Amount
(b) Capacity 2 LPS each minimum 0
Head 20 Mts. 0
(c ) Capacity 5 LPS each minimum 0
Head 75 Mts. 0
54 MR Providing and fixing Float Glass Mirror of minimum 6mm sqm 100 1140.46 114046
55 MR thickness, &
Providing of fixing
required shape
Hand and (Health
Shower size of Faucet)
with 8mm"Saint 0
For 1M long of PVC tubefixtures
sanitary and wallas hook CP brass
per above wall
details Each 119 813.74 96835.06
57.7 N.S. Providing sanitary sealing on top as per I.S. with 1:3:6 PCC Each 2 4427.48 8854.96
58.9 N.S. Block of sizeInstallation,
Supplying, 1m x 1m x 1m.Testing, commissioning and 0
a). N.S. lowering
Total headof -submersible
50 mts. pumps set as per specifications 0
Flow rate - 8000 ltr/ hr.(Minimum)-5 hp motor (appx.) Each 2 49618.32 99236.64
57.10 N.S. Supply & Installation of G.I Class `C' column pipe with flanges 0 0 0
50 mmintervals
dia including all fittings, flanges, clamps as Meter 50 687.02 34351
58 N.S Supply, erection, installation in line and level with underground 0
mm O.D. with Nu drain pipes complying to IS- 15382
pipeline Meter 2000 771.76 1543520
(b) 250 mm O.D. pipeline Meter 972 1232.82 1198301.04
Part Rate 616.41 184923
59 MR Supply Installation, Testing and Commisioing of 0
Grab Toilet (Mirror
Bar 600mm specialfinish
fixtures of make
stainless steelParryware
32 mm diaor Each 6 5375 32250
Support 600mm U type mirror finish stainless steel, 32 Each 6 10604 63624
600mm thickness
x 600 mm (Mirror finish stainless steel 32 each 6 5707 34242
60 12.7 mm dia 1.5mm
Providing thickness)
and fixing 15 cm wide, 45 cm overall semi-circular 0
12.7.1 plainmm
0.80 G.S.thick
zinc iron brackets
coating 40x3mm
not less than size, bolts,
SUPPLY OF MANUALLY OPERATED ELECTRICAL
1.0 FIRE ALARM
Supplying, installation, testing & commissioning of addressable Each
manual callinstallation,
Supplying, point complete as required.
testing & commissioning of addressable Each
2.0 horn cum OF
HANDHELD EXTINGUISHERS
2a CO2 GAS type handheld fire extinguishers - 4.5 kg Nos
2b ABC - dry powder type handheld fire extinguishers- - 6kg Nos
2c CO2 cartridge triggered water type handheld extinguishers - 5 Nos
TERRACE LEVEL BOOSTER PUMP
3.0 Supplying, installation, testing and commissioning of electric
900 lpmterrace
m Head suitable for automatic operation and Set
MR Providing and fixing ISI Marked of approved make Fire
a) ABC dry completepowder with
stored all accessories
pressure typeas per6 kg capacity Nos 66 3000 198000
FIRE HYDRANT SYSTEM
Providing, laying, testing & commissioning of 'C' class heavy
150mm pipe conforming to IS 3589/IS 1239 Mtr
2.0 Providing 63 mm dia GM single outlet flanged inlet Nos
3.0 oblique type
Providing fire hydrant
approved drum type landing valve with
wall mounted C.I.hose
first aid hand
Providing , swivelling
in position 2 lengths180 of degrees consisting
15 mtr long and 63mmof dia, Nos
5.0 controlled, Fire
Providing percolated RRLinlet
Brigade linedSiamese
canvass connection
hose (Conforming to
fabricated Nos
6.0 from 150mm
Providing suitable G.M. Drain valve of 25mm dia. and GI Nos
7.0 drain pipe inof required
Providing position length
cast iron including
150 mmPN dia16 kg/sqcm standard pattern (Horizontal / Nos
100 mm dia Nos
8.0 Providing heavy approved quality cast iron dual plate type
diavalves with pressure rating PN 16 kg/sqcm Nos
10.0 Providing of pressure gauge, glycerine filled with guage cock, Nos
11.0 siphon andofsocket
Providing welded
200 Lit throughtank
diaphragm pipes etc.pressure
with complete switch etc, Nos
12.0 complete for
Providing auto operation
of Fireman axe of Hydrant and Sprinkler pump Nos
SUB TOTAL (Q) 0 198000
SWERAGE TREATMENT PLANT (STP)
56 MR SEWAGE TREATMENT PLANT - MBR Based
Design, Supplying, Installing, Testing & Commissioning of
Daily Treatment
average flow Plant flow /capacity
- 50 Cum Day as mentioned below with
Influent Characterstics - 50 KLD
Rate Amount Rate Amount
BOD 3 - 250 to 400 mg/l
Suspended Solids 200 - 450 mg/l
COD - 600 to 800 mg/l
Effluent discharge standard after treatment
BOD3 - < 10 mg/l
Suspeded Solids - < 10 mg/l
COD - < 80 mg/l
Invert Level of Sewer to STP = As per consultant
Sewage treatment plant shall include the following items
Grease removal unit - 1 No.
Sewage Equalization tank in RCC const.-1 No.
(Below ground as per sewer invert level)
Submersible Sewage Lift Pumps in Equalisation
Membrane Bio reactor with UF submersible
Membrane module and aeration
U.V. Disinfection Chamber - 1 No.
Filter Press / Centrifuge basket type/draimad system
Treated Water Tank in HDPE const.
Air Blowers, Pumps & equipment
Piping, valves etc
Electrical Panel & Cabling
Common plant room adjacent to STP.
Soft water tank (when required)
All piping, valves & level indicator/controller etc within plant
Supply, installation, testing & commissioning of 2 Nos. Set
Stainless Steel
Providing finePerforated
screen ofScreen with suitable
self cleaning typelifting
before effluent Set
entering installation,
Supply, to MBR tank.testingContractor shall ensure submission
& commissioning of
of non clogging
shall have CI casing, impeller complete with all
following: Set
Submersible Raw Effluent Sump Pumps (2 Nos - 1 working + 1
Make - KSB/ Grundfos/ Shimge/ JS/ Wilo (Solid handling cap
Flow rate (each) = 3.75 m3/hr
Provision of guide ropes to guide submersible pump from upper
level to operational
Supply, installation,level in sump
testing and basin with channels
commissioning / angle
bioreactoreffluent
Permeate having membranes of ultrafiltation
capacity : 50.00 KLD suitable for Job
Air diffusion system shall include the following :
2 Nos. twin type rotary air blowers (one working & one Set
piping shallBeta / Everest
comprise of/ pipes
Usha) droppers/laterals
with acoustic cover with SS Lot
Non clog type in MS
dispersionwith all fittings
system capablesuch
of as tees, 6-7
cfm equalization
For of air with oxygen transfer
tank (coarse with efficiency of 3-4%
For Aeration tank (fine bubble) Lot
Bronze Ball Valve / Butterfly Valve and air dispersion grid as Lot
dispersion as described
system shall beabove
provided for Equalisation Tank,
Providing and Aerated
fixing Biomedia
all pipingReactor
(as described below) and
isolation control
Supply, valvestesting
installation, for making the system complete.
& commissioning of Chlorine Job
dosing pumpinstalling,
Supplying, with tanktesting
& of dosing capacity
commissioning ofdosing
Permeate pumps
Suction (make-Kirloskar,CRI,Eqv.) along with
Capacity - 3.75 m3/hr
No. of Pumps 2 no's (1 working + 1 standby)
Back Wash Pumps Set
Capacity - 3.75 m3/hr
No. of Pumps 2 no's (1 working + 1 standby)
Treated Water Transfer Pumps Set
Capacity - 3.75 m3/hr
Head : 10 -12 M
No. of Pumps 2 no's (1 working + 1 standby)
Operation of pump shall be based on PLC required to operate
for recommended
Supply, installation, operation of permeate
testing and suction of
commissioning pump
filter press of
Screw Capacity
Capacity 0.5frame,
m3/hrPP@plates complete with filter
Size of Plate 12" x 12" Approx.
No. of Plates - 12 No's
ELECTRICAL INSTALLATION FOR STP
Design, fabrication, assembling, wiring, supply, installation,
testing Control
Motor and commissioning
Centre of motor control centre fabricated
Incoming125 amps TPN MCCB with the following accessories:
a. 0-500 volts 96 x 96 mm square electronic voltmeter with
selector switch shall be protected by 2 amps TP MCB. 1 Set
Rate Amount Rate Amount
b. 0-100 amps 96 x 96 mm square electronic ammeter with
c. Phase switch and 100./5
indicating ampsbe
lamps shall 10protected
VA CL:1by CTs. 1 SetSP MCB
125 amps TPN (15 KA) copper bus bar with heat shrinkable
insulation sleeves.
a. Required Nos of required capacity TPN MCB for direct on Nos
starter/star deltaofstarters and out
following going feeders
capacities: i. 32toamps
c. 3 Nos.cable alleys, internal / cabling, wiring, cabling
NotesMCC: to various pumps / equipment and interlocking,
a. All MCCBs / MCBs shall be of 15 KA breaking capacity and
All motor dutyshall
starters application
be provided with Automatic level
c. DOL starters shall be used for mototrs below 10HP and Star-
d.Provision for other
shall be mademotors.
for providing potential free contacts
TOTAL Forstarters
50 KLD MCCPlantforcomplete
all STP equipments/pumps
as above as set 0 2262400 0
SUB TOTAL (R) 0 791840
EXTERNAL DEVELOPMENT
1.00 2.0 EARTH WORK
1.01 2.28 Surface dressing of the ground including removing
2.28.1 vegetation
All kinds ofandsoil.in- equalities not exceeding 15 cm deep and Sqm 0 13.29140821 0
Part Rate 0 0 0
1.02 2.25 Filling available excavated earth (excluding rock) in Cum 6000 125.75 754500
trenches, plinth, sides of foundations etc. in layers not 0 0 0
2.00 4.0 CONCRETE WORK 0 0 0
2.01 4.1 Providing and laying in position cement concrete of specified 0 0 0
4.1.8 grade (1
1:4:8 excluding
Cement the cost ofsand
: 4 coarse centering
(zone-and shuttering - All work Cum 170 4478.15 761285.5
III) : 8 graded stone aggregate 40 mm nominal size) 0 0 0
3.00 ROAD WORK 0 0 0
3.01 16.1 Preparation and consolidation of sub grade with power road Sqm 2917 90.1 262821.7
Part of 8 to 12 tonne capacity after excavating earth to an 3600 9.01 32436
3.02 16.68 Providing and laying 60mm thick faciory made cement Sqm 2017 615.7 1241866.9
3.03 16.78 concrete interlocking
Construction of granular paver block by
sub-base of providing
M -30 gradeclose made 0 0 0
16.78.3 gradedmaterial
With Material conforming
conforming to specifications,
to Grade-III (size rangemixing
Part Rate mm ) having CBR Value-20 0 0 0
3.04 16.79 Providing, laying, spreading and compacting graded Cum 225 2132.25 479756.25
Part aggregate (size range 53 mm to 0.075 mm ) to wet 900 213.225 191902.5
3.05 16.55 Providing and laying bituminous macadam using 0 0 0
16.55.1 crushed
50 to 100stone mmaggregates of
average compacted specified
thickness grading
with bitumen Cum 293 5708.05 1672458.65
3.06 16.57 of grade VG-30
Providing and laying Bituminous concrete using 0 0 0
16.57.1 crushedmm compacted
40/50 stone aggregatesthickness of with
bitumen grading,
Providing 5.5% (percentage
applying by weight
tack coat usingof total mix)
bitumen and lime
emulsion 0 0 0
16.31.1 conforming
rapid setting 8887, emulsion
bitumen using emulsion pressure 0 0 0
16.31.1.2 On bituminous surface @ 0.25kg/sqm Sqm 4500 8.65 38925
16.31.2 With medium setting bitumen emulsion 0 0 0
3.08 16.69 Providing and laying at or near ground level factory made 0 0 0
(Precast of M-kerb25 grade
shall concrete in position
be approved to the
by Engineer-in- Cum 281.68 5012.65 1411963.252
4.01 2.6 Earth work in excavation by mechanical means (Hydraulic
2.6.1 excavator)/manual
a) All kinds of soil means over areas (exceeding 30 cm in depth, Cum 4105 125.95 517024.75
4.02 MR Providing & Laying100 mm depth Granular Fill compacted to Cum 415 1250 518750
4.03 22.21 95% dry density
Providing and laying Geotextile, 120 gsm non woven, 100% Sqm 4105 76.65 314648.25
polyester of thickness 1 to 1.25 mm as per manufactures
5.00 HORTICULTURE
5.01 MR PLUMERIA ALBA Nos 100 700 70000
5.03 MR FICUS BENJAMINA Nos 25 200 5000
5.04 MR ROYSTONEA REGIA Nos 25 800 20000
5.05 MR AZADIRACHTA INDICA Nos 25 150 3750
5.06 MR ALBIZIA SAMAN Nos 25 150 3750
5.07 MR CASSIA FISTULA Nos 25 200 5000
5.08 MR FICUS BENGHALENSIS Nos 5 200 1000
5.09 MR FICUS RELIGIOSA Nos 25 200 5000
5.10 MR CRAPE MYRTLE Nos 25 400 10000
5.11 MR MANGIFERA INDICA Nos 25 300 7500
5.12 MR JUNIPERUS VIRGINIANA Nos 25 200 5000
5.13 MR DALBERGIA SISSOO Nos 25 300 7500
5.14 MR HERITIERA FOMES Nos 25 400 10000
5.15 MR SHOREA ROBUSTA Nos 25 200 5000
5.16 MR MADHUCA LONGIFOLIA Nos 25 400 10000
5.17 MR ARECA CATECHU Nos 25 200 5000
Rate Amount Rate Amount
5.18 MR CASIA JAVANICA Nos 25 1000 25000
5.19 MR FOXTAIL ORCHID Nos 25 200 5000
5.20 MR DELONIX REGIA Nos 25 800 20000
5.21 MR WASHINGTONIA FILIFERA Nos 25 400 10000
5.22 MR SRACA ASOKA Nos 25 800 20000
5.23 MR CYCUS REVOLUTA Nos 25 60 1500
5.24 MR FICUS PANDA Nos 500 45 22500
5.25 MR FICUS DANIELLA Nos 500 200 100000
5.26 MR FICUS STARLITE Nos 500 60 30000
5.27 MR HEMELIA PATENS Nos 500 30 15000
5.28 MR DURANTA GOLDEN Nos 500 60 30000
5.29 MR FICUS ELASTICA Nos 500 20 10000
5.30 MR OPHIOPOGON JAPONICUS Nos 500 30 15000
5.31 MR PENNISETUM SETACEUM RUBRUM Nos 500 40 20000
5.32 MR PENNISETUM SETACEUM RUBRUM Nos 500 30 15000
5.33 MR RHOEO SPATHACCA Nos 500 40 20000
5.36 2.3 Supplying and stacking of good earth at site and profile making SQ M 4000 332.55 1330200
with available/
SUB TOTAL (S) supplied earth in terraces, slopes, mounds as per 9644819.735 3908398.25
ELECTRICAL WORKS
1 Point Wiring
1.01 1.100 Wiring for light point/ fan point/ exhaust fan point/ call bell
1.10.3 point with
Group C 1.5 sq.mm FR PVC insulated copper conductor Point 2460 757 1862220
1.02 1.120 Wiring for light/ power plug with 2X4 sq. mm FR PVC Metre 5178.53 168 869993.04
1.03 1.130 insulatedfor
light/conductor
power plugsinglewith
4X4 insq.surface/
mm FR PVC Metre 3480 281 977880
1.04 1.240 insulated copper
Supplying conductor
and fixing singlemodular
following core cable in surface/
switch/ socket on the 0 0 0
1.24.1 existing
5/6 ampsmodular
switch plate & switch box including connections but Each 929 84 78036
1.24.4 3 pin 5/6 amp socket outlet Each 1043 81 84483
1.24.5 6 pin 15/16 amp socket outlet Each 299 153 45747
1.24.8 Bell push Each 50 114 5700
1.05 1.250 Supplying and fixing stepped type electronic fan regulator on Each 376 288 108288
1.06 1.260 the existingand
Supplying modular
fixingplate switchblanking
modular box including
plate connections but
on the existing Each 250 24 6000
1.07 1.270 modular plate
Supplying and&fixing
switch box excluding
following modular
size/module, GIplate
along with 0 0 0
1.27.1 Modular
1 base & cover plate on existing modular metal boxes
or 2 Module Each 0 175 0
2 Submain and Control Wiring
2.01 1.1 Wiring for circuit/ submain wiring alongwith earth wire with
1.14.1 thex following
2 1.5 sq. mmsizes
x 1.5 PVC insulated
mm copper conductor,
earth wire Metre 4128 112 462336
1.14.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire Metre 0 137 0
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire Metre 500 168 84000
1.14.4 2 x 6 sq. mm + 1 x 6 sq. mm earth wire Metre 0 227 0
1.14.5 2 x 10 sq. mm + 1 x 6 sq. mm earth wire Metre 300 299 89700
1.14.6 2 x 16 sq. mm + 1 x 6 sq. mm earth wire Metre 900 408 367200
Extra DSR 1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire Metre 0 0 0
Extra DSR 1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre 0 0 0
2.02 1.2 Supplying and fixing of following sizes of medium class PVC 0 0 0
1.21.2 conduit
25 mm along with accessories in surface/recess including Metre 7500 69 517500
Part Rate 0 0 0
3.01 7.1 Laying of one number PVC insulated and PVC sheathed /
7.1.1 XLPE35power
Upto sq mmcable of 1.1 KV grade of following size direct in Metre 2396 206 493576
7.1.2 Above 35 sq mm and upto 95 sq mm Metre 350 214 74900
7.1.3 Above 95 sq mm and upto 185 sq mm Metre 470 223 104810
7.1.4 Above 185 sq mm and upto 400 sq mm Metre 1895 248 469960
3.02 9.1 Supplying and making end termination with brass compression 0 0 0
3½ and aluminium
X 400 lugs for following size of PVC insulated
Rate Amount Rate Amount
Extra DSR 9.1.29 3½ X 240 sq. mm (62mm) Each 0 0 0
3.03 8.100 Laying of one number PVC insulated and PVC sheathed/ XLPE 0 0 0
8.5.2 power cable
120 sq. 11kV grade
sq mm size direct in ground Metre 100 301 30100
4.01 2.1 Supplying and fixing single pole blanking plate in the existing Each 200 7 1400
4.02 2.1 MCB DB complete
Supplying and fixingetc.
amps to 32 amps rating, 240/415 volts, 0 0 0
2.10.1 "C" curve,
Single poleminiature circuit breaker suitable for inductive load Each 825 173 142725
2.1 Supplying and fixing following rating, four pole, 415 volts, 0 0 0
2.13.1 isolator
40 ampsin the existing MCB DB complete with connections, Each 30 667 20010
4.03 2.5 Supplying and fixing following way, vertical type three pole 0 0 0
8 wayneutral, sheet
(4 + 24), steel, door
Double MCB distribution board, 415 volts, on Each 32 5664 181248
Extra 2.2 Providing and fixing following rating and breaking capacity and
pole MCCB with thermomagnetic release and terminal
2.2.13 100 A, 30kA,TPN MCCB Each
4.04 2.1 Supplying and fixing following rating, double pole, (single
25 and neutral), 240 volts, residual current circuit breaker
2.2 Supplying and fixing following rating, four pole, (three phase 0 0 0
2.15.3 andAneutral), 415 V, residual current circuit breaker (RCCB),
2.4 Supplying and fixing following way, horizontal type three pole 0 0 0
(4 + 18), steel, door
Double MCB distribution board, 415 V, on Each 0 2659 0
5 PROVISIONS FOR VOICE, DATA, SECURITY & TV 0 0 0
5.01 1.2 SYSTEMSand fixing following modular switch / socket on the
Supplying 0 0 0
1.24.6 existing
Telephonemodular
outlet& switch box including connections but Set 183 96 17568
1.24.7 TV socket outlet Set 158 97 15326
5.02 1.18.2 Supplying and drawing following pair, 0.5 sq.mm FR PVC 0 0 0
2 Pair copper conductor, unarmoured telephone cable in the Mtr. 3660 19 69540
6 LIGHTING FIXTURES & FITTINGS
6.01 1.41 Installation, testing and commissioning of pre-wired, Each 1260 100 126000
6.02 1.45 fluorescent fitting
Installation, testing/ compact fluorescent fitting
and commissioning of all
of ceiling fantypes, with
including Nos. 378 132 49896
6.03 1.50.1 wiring the down
Installation rods of fan
of exhaust standard
in thelenght (uptoopening,
existing 30 cm) with 1.5
including Nos. 145 224 32480
mmthe damage, connection, testing, commissioning
6.04 1.51 Extra for fixing the louvers/ shutters complete with frame for Nos. 145 99 14355
exhaust fan of all sizes. 0 0 0
7.01 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick Set 42 4327 181734
7.02 5.6 includingwith
Earthing accessories,
Copper andearthproviding
plate 600masonry
600 mm Xwith 3 mm Set 4 8289 33156
7.03 5.9 thick including
Supplying and accessories,
laying 25 mm andXproviding
5 mm G.I masonry
strip atenclosure
0.50 metre Metre 200 85 17000
7.04 5.14 below ground
Providing and as strip25
mmelectrode, including
X 5 mm Copper connection/
strip on surface or Metre 0 698 0
7.05 5.15 in recess for
Providing connections
and fixing 25 mmetc. Xas 5required.
mm G.I. strip on surface or in Metre 200 129 25800
7.06 5.18 recess for connections
Providing and fixing etc.
6 SWGas required.
dia G.I. wire on surface or in Metre 1000 23 23000
7.07 5.70 recess for loop
Supplying and earthing
SWGwith G.I.existing
wire atsurface/ recessed
0.50 metre below Metre 100 28 2800
ground level for conductor earth electrode, including
9 Substation Equipments
9.04 10.5 11 KV CABLE JOINTING:
Supplying and making outdoor cable end terminations with heat
10.5.4 shrinkable
300sq mm cable jointing kit complete with all accessories nos. 4 9464 37856
Rate Amount Rate Amount
10 SAFETY ITEMS 0 0 0
10.07 2.21 Providing and fixing MV danger notice plate of 200mm x nos. 30 149 4470
Providing andoffixing
mm thick, andofvitreos
plate 250mm x nos. 5 163 815
200mm made of mild steel, atleast 2 mm thick, and vitreos 0 0 0
11 LIGHTNING 0 0 0
11.01 6.2 Providing and fixing of lightening conductor finial, made of 25 Each 25 304 7600
11.02 6.3 mm diaof
Fixing 300 mm long,conductor
lightening G.I. tube, finial
top, base Each 25 170 4250
11.03 6.4 plate including
Jointing copper/holesG.I. etc.
tapecomplete as required.
(with another copper/ G I tape, base Each 50 57 2850
11.04 6.7 of the finialand
Providing or fixing
any otherG.I.mettallic
tape 20 object)
mm X 3bymm rivetting/
thick onnutparapet Metre 375 66 24750
11.05 6.8 or surface of
Providing andwall for lightning
fixing conductor
G.I. tape 20 mm X 3complete
mm thick as on
parapet Metre 150 100 15000
11.06 6.12 or surface of
Providing andwall for lightning
fixing conductor
testing joint, madecomplete
of 20 mm as required.
11.07 6.14 thick G.I. strip,
Providing and 125 mmG.I.
laying long, with324 nos.
tape mm of X G.I.
6 mmbolts, nuts,earth
from Metre 250 112 28000
electrode directly in ground as required.
4.1 Supplying and installing following size of perforated painted
X 50 mm depth X 1.6 mm thickness Metre
3.04 MR Supply of following XPLE armourned 1.1 KV grade
Supply of tofollowing
I.S.7098/1554sizes Aluminium
of PVC Conductor Cables :
sheathed PVC/XLPE
3.5c x 400Aluminium
sqm XLPEconductor
cable armoured cable of 1.1 KV RM 500 1293 646500
Extra (b) 3.5c x 300 sqm XLPE cable RM 200 1015 203000
Extra (c ) 3.5c x 240 sqm XLPE cable RM 1195 828 989460
(d) 3.5 C x 185 Sqmm XLPE cable RM 250 658 164500
(e) 3.5 C x 120 Sqmm XLPE cable RM 100 445 44500
(f) 3.5 C x 95 Sqmm XLPE cable RM 120 356 42720
(g) 3.5 C x 70 Sqmm XLPE cable RM 150 295 44250
(h) 3.5 C x 50 Sqmm XLPE cable RM 10 217 2170
(i) 3.5 C x 35 Sqmm XLPE cable RM 0 161.1 0
Part Rate 0 0 0
Part Rate 30 3.92 117.6
(l) 4c x 10 sqm XLPE cable RM 50 98 4900
6 LIGHTING FIXTURES & FITTINGS 0 0 0
6.05 MR Supply of ISI marked energy efficient exhaust fan plastic ideal Each 145 1030.53 149426.85
6.06 MR for mounting
Supply of LED on Tubelight
glass window with
batten 200mm sweep
including (Havells
lamp fitting andCat
6.07 MR accessories
Supply of ISIas required. (Philipsefficient
marked energy Cat no. BEE- 31082 slimline
FIVE STAR18rated 0 0 0
sweepfan with double ball bearing, motor, blades, down Each 378 1403.82 530643.96
6.08 MR Supply, Installation, Testing and Commissioning of Hot dip Each 45 8778.63 395038.35
6.09 MR Galvanized
Supply, octagonal pole
installation, with integral
testing cotrol box, MCB
and commissioning of and
6.1 MR performance
Supply of LED 72W LED street
concealed light 7200
lighting suitablelumens, with
for 2x2 false ceiling Each 0 4541.98 0
6.11 MR grid including
Supply lamp fitting
of 1 x 12watt LED andwallall accessories
mounted lightas required.
fixture for mirror Each 101 1141.22 115263.22
6.12 MR light complete
Supply of 60W with lamp
wall and all accessories
light/bracket as required.
light with lamp and all Each 20 2213.74 44274.8
6.13 MR accessories
Surface 1 xas15watt
required.LED (Philips Cat No
mounted 36677 - My
downlighter Living
fitting and all Each 108 1488.55 160763.4
6.14 MR accessories as required.
Supply, Installation, (Philips
Testing andCat no. -
Commisioning of Wall fan of Each 0 1910.69 0
size 400mm with minimum RPM of 1360 or above with wiring
8 PANEL BOARDS
8.01 MR MAIN LT PANEL
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
All MCCBs in Main LT Panel shall have minimum 50 kA
The capacityshall be electrically inter-locked as shown in
Colour: Graydiagram
Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 1600 Amps. 4 pole ACB and 2 nos. 630 Amps 4 pole
a) i.e four pole
Independent horizontal
manual springdraw out type
closing air circuitNo.
b) Microprocessor release (EMI & EMC certified) for over
current,Digital
c) earth fault
type &Voltmeter,
short circuit protection-1set.
with selector switch & back up
HRC fuses/MCB’s-1
Digital type Ammeter, with selector switch and one set of
e) Nos.ofPhase
indication Class
lamps for andeach
f) Amp tripbackcoil
HRCVfuse,AC. breaker ‘ON’ indicating light
1 No.-800 Amps horizontal four pole drawout type, ACB of
a) Independentcapacity
manual50 KA (ICS=ICU
spring up to 433V) No.
closing mechanism-1
b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse
Bus Bars: block, fuses, circuits as per standard practice,
TPN aluminum bus bars of minimum of 1600 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
Electrical through advance contacts in ACB's/MCCB’s
Outgoings:& Bus Couplers) and mechanical (Castel Key)
Rate Amount Rate Amount
(a) 630 Amps TPN MCCB (ICS = 36kA) - 2 Nos.
(b) 400 Amps TPN MCCB (ICS=36 kA) - 2 Nos.
(c) 250 Amps TPN MCCB (ICS=25 kA) - 2 Nos.
(d) 200 Amps TPN MCCB (ICS=25 kA) - 4 Nos.
(e) 160 Amps TPN MCCB (ICS=25 kA) - 2 Nos.
(f) 100 Amps TPN MCCB (ICS=25 kA) - 12 Nos.
(g) 63 Amps, TPN, MCB -12 Nos.
CAPACITOR PANEL (320 KVAR):
Supply, install, test and commissioning of floor mounted
Panel panel 320
as above Capacity
capacitor step automatic
8.02 MR METER PANEL
Design, fabrication, assembling, wiring, supply, installation,
testing andshall
Approval commissioning
be obtainedoffrom
concerenedTYPE cubicle type
Electricity Board
The shop drawings
metering before
panel shall fabrication.
comprise the following
Trivector Meter of Secure make, accuracy class 0.5
3 nos cast resin CT's of 5/1 amps CT ratio, 15VA burden and
phase0.5potential transformer of approved make by
Electricity Board
VA Burden 100VA
The metering panel shall be complete with all interconnections Set
etc. as above including calibration of instruments as per
8.03 MR Sub Main Panel for Academic Block
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 250 Amps. 4 pole MCCB , i.e four pole Moulded Case
a) Breaker of manual
Independent fault breaking
spring capacity 36 KA (ICS=ICU
closing mechanism-1 No. up
b) Microprocessor release (EMI & EMC certified) for over
current,Digital
c) earth fault
type &Voltmeter,
short circuit protection-1set.
with selector switch & back up
HRC fuses/MCB’s-1
Digital type Ammeter, with selector switch and one set of
e) Nos.ofPhase
indicationClass
lamps for andeach
AC. breaker ‘ON’ indicating light
TPN aluminum bus bars of minimum of 500 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(a) 100 Amps TPN MCCB - 2 Nos.
(b) 63 Amps, TPN, MCB -8 Nos.
MR Panel complete as above each
8.04 MR Sub Main Panel for Boys Hostel
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 250 Amps. 4 pole MCCB , i.e four pole Moulded Case
Bus Breaker of fault breaking capacity 25 KA (ICS=ICU up
TPN aluminum bus bars of minimum of 320 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(a) 63 Amps, TPN, MCB -6 Nos.
Panel complete as above each
8.05 MR Sub Main Panel for Girls Hostel/Guest House
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 200 Amps. 4 pole MCCB , i.e four pole Moulded Case
Bus Breaker of fault breaking capacity 25 KA (ICS=ICU up
TPN aluminum bus bars of minimum of 400 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(b) 63 Amps, TPN, MCB - 4 Nos.
Rate Amount Rate Amount
Panel complete as above each
8.06 MR Sub Main Panel for Admin/ Canteen/ Amenities/ Recreation
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 100 Amps. 4 pole MCCB , i.e four pole Moulded Case
Bus Breaker of fault breaking capacity 25 KA (ICS=ICU up
TPN aluminum bus bars of minimum of 200 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(b) 63 Amps, TPN, MCB - 2 Nos.
MR Panel complete as above each
8.07 Plumbing Panel
Supplying, installation, testing and commissioning of cubical
Incomer: 1nospanel
MCCB. suitable outdoor use for 415 V,
1 no 96mm x 96mm digital Voltmeter and Ammeter with LCD
1 set of for voltage
three phase&indicating
current with suitably
lamps rated CTs
with suitable and MCB
Busbar: Equally sized three phase and neutral copper bus bars
suitably sized to carry 300A current with colour coded heat
6nos 63A TPN MCBs
2nos 25A TPN MCBs
6nos 16A TPN MCBs
MR Panel complete as above each
8.07 External lighting panel
Supplying, installation, testing and commissioning of cubical
type outdoor panel
Incomer:1nos with canopy
63A TPN MCCB suitable outdoor use for 415 V,
1 no 96mm x 96mm digital Voltmeter and Ammeter with LCD
1 set of for voltage
three phase&indicating
current with suitably
lamps rated CTs
with suitable and MCB
Busbar: Equally sized three phase and neutral copper bus bars
suitably sized to carry 100A current with colour coded heat
5nos 32A TPN MCBs
Panel complete as above each
8.09 MR Supply, Installation, Testing and Commisioning of Cubical type
(a) compartmentalized
Suitable for set of meter board Main
2 quarters made meter
of 1.6mm thick
board steel as
H PANEL BOARDS
H.1 MR MAIN LT PANEL
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
All MCCBs in Main LT Panel shall have minimum 50 kA
The capacityshall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
3 nos, 800 Amps. 4 pole ACB and 1 nos. 320 Amps 4 pole
a) i.e four pole
Independent horizontal
manual springdraw out type
closing air circuitNo.
b) Microprocessor release (EMI & EMC certified) for over
Digital fault Voltmeter,
& short circuit
withprotection-1set.
selector switch & back up
HRC fuses/MCB’s-1
Digital type Ammeter, with selector switch and one set of
e) Nos.of ratioindication
Phase 1600/5A Class I accuracy
LED lamps and incoming
for each 15 VA
f) Amp tripbackcoil
AC. breaker ‘ON’ indicating light
1 No.-1000 Amps horizontal four pole drawout type and 1 No.
Independent four pole
manual drawout
spring closingtype, ACB of fault
mechanism-1 No.
b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse
Bus Bars: block, fuses, circuits as per standard practice,
TPN aluminum bus bars of minimum of 1600 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
Electrical through advance contacts in ACB's/MCCB’s
(Incomers & Bus Couplers) and mechanical (Castel Key)
(a) 630 Amps TPN MCCB (ICS = 36kA) - 4 Nos.
(b) 400 Amps TPN MCCB (ICS=36 kA) - 2 Nos.
(c) 250 Amps TPN MCCB (ICS=25 kA) - 2 Nos.
(d) 200 Amps TPN MCCB (ICS=25 kA) - 4 Nos.
(e) 160 Amps TPN MCCB (ICS=25 kA) - 2 Nos.
(f) 100 Amps TPN MCCB (ICS=25 kA) - 8 Nos.
Rate Amount Rate Amount
(g) 63 Amps, TPN, MCB -8 Nos.
CAPACITOR PANEL (320 KVAR): -
Supply, install, test and commissioning of floor mounted
Panel panel 320
as above Capacity
capacitor step automatic
(1) SITC of PLC for auto selection of DG sets depending on the
Additional switching
Capacitor of bus
of 180 KVAR for safety and error free
H.2 MR METER PANEL
Design, fabrication, assembling, wiring, supply, installation,
testing and commissioning
arrangement for sealing the of OUTDOOR
covers and doors,TYPE cubicle typeof
Approval angle
shall iron, channels,
be obtained T sections Electricity
from concerened of flats wherever
The shop drawings
metering before
panel shall fabrication.
comprise the following
Trivector Meter of Secure make, accuracy class 0.5
3 nos cast resin CT's of 5/1 amps CT ratio, 15VA burden and
1 classpotential
no. 3 phase 0.5 transformer of approved make by
Electricity Board
VA Burden 100VA
The metering panel shall be complete with all interconnections Set 1 225000 225000
etc. as above including calibration of instruments as per
H.3 MR Sub Main Panel for Academic Block
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 630 Amps. 4 pole MCCB , i.e four pole Moulded Case
a) Breaker of manual
Independent fault breaking
spring capacity 50 KA (ICS=ICU
closing mechanism-1 No. up
b) Microprocessor release (EMI & EMC certified) for over
Digital fault Voltmeter,
& short circuit
withprotection-1set.
selector switch & back up
HRC fuses/MCB’s-1
Digital type Ammeter, with selector switch and one set of
e) Nos.of ratioindication
Phase 1000/5A Class I accuracy
LED lamps and incoming
for each 15 VA
AC. breaker ‘ON’ indicating light
TPN aluminum bus bars of minimum of 800 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(a) 200 Amps TPN MCCB - 2 Nos.
(b) 160 Amps TPN MCCB - 2 Nos.
(c) 100 Amps TPN MCCB - 6 Nos.
(d) 63 Amps, TPN, MCB -12 Nos.
MR Panel complete as above each 0 201620 0
Part Rate 1 20162 20162
H.4 MR Sub Main Panel for Guest House
Designing, fabricating, transporting, unloading, storing, fixing
Typeposition, testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 400 Amps. 4 pole MCCB , i.e four pole Moulded Case
a) Breaker of manual
Independent fault breaking
spring capacity 50 KA (ICS=ICU
closing mechanism-1 No. up
b) Microprocessor release (EMI & EMC certified) for over
Digital fault Voltmeter,
& short circuit
withprotection-1set.
selector switch & back up
HRC fuses/MCB’s-1
Digital type Ammeter, with selector switch and one set of
e) Nos.of ratioindication
Phase 1000/5A Class I accuracy
LED lamps and incoming
for each 15 VA
AC. breaker ‘ON’ indicating light
TPN aluminum bus bars of minimum of 630 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(a) 160 Amps TPN MCCB - 2 Nos.
(b) 100 Amps TPN MCCB - 4 Nos.
(c) 63 Amps, TPN, MCB -6 Nos.
MR Panel complete as above each 1 156600 156600
H.5 MR Sub Main Panel for Boys Hostel/ Admin Building
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: diagram
Gray Powder and as detailed
Coated, as perinapproved
the Specifications
Rate Amount Rate Amount
1 nos, 250 Amps. 4 pole MCCB , i.e four pole Moulded Case
Bus Breaker of fault breaking capacity 25 KA (ICS=ICU up
TPN aluminum bus bars of minimum of 320 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(a) 100 Amps, TPN, MCCB -2 Nos.
(b) 63 Amps, TPN, MCB -12 Nos.
MR Panel complete as above each 0 99830 0
H.6 MR Sub Main Panel for Girls Hostel/ Canteen
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: Graydiagram
Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 200 Amps. 4 pole MCCB , i.e four pole Moulded Case
Bus Breaker of fault breaking capacity 25 KA (ICS=ICU up
TPN aluminum bus bars of minimum of 400 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(a) 63 Amps, TPN, MCB -8 Nos.
MR Panel complete as above each 0 65250 0
H.7 MR Sub Main Panel for Amenities
Designing, fabricating, transporting, unloading, storing, fixing
Type testing andForm
of construction: commissioning
3 the following sheet steel
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Colour: Graydiagram
Powder and as detailed
Coated, as perinapproved
the Specifications
1 nos, 160 Amps. 4 pole MCCB , i.e four pole Moulded Case
Bus Breaker of fault breaking capacity 25 KA (ICS=ICU up
TPN aluminum bus bars of minimum of 200 Amps capacity
with heat shrinkable colored sleeves and I/C DMC/SMC bus
(b) 63 Amps, TPN, MCB -4 Nos.
Panel complete as above each 0 48285 0
H.8 Plumbing Panel
Supplying, installation, testing and commissioning of cubical
Incomer: 1nospanel
MCCB. suitable outdoor use for 415 V,
1 no 96mm x 96mm digital Voltmeter and Ammeter with LCD
1 set of for voltage
three phase&indicating
current with suitably
lamps rated CTs
with suitable and MCB
Busbar: Equally sized three phase and neutral copper bus bars
suitably sized to carry 300A current with colour coded heat
6nos 63A TPN MCBs
2nos 25A TPN MCBs
6nos 16A TPN MCBs
MR Panel complete as above each 1 70470 70470
H.9 External lighting panel
Supplying, installation, testing and commissioning of cubical
type outdoor panel
Incomer:1nos with canopy
63A TPN MCCB suitable outdoor use for 415 V,
1 no 96mm x 96mm digital Voltmeter and Ammeter with LCD
1 set of for voltage
three phase&indicating
current with suitably
lamps rated CTs
with suitable and MCB
Busbar: Equally sized three phase and neutral copper bus bars
suitably sized to carry 100A current with colour coded heat
5nos 32A TPN MCBs
Panel complete as above each 4 38824 155296
H.10 Supply, Installation, Testing and Commisioning of Cubical type
(a) compartmentalized
Suitable for set of 2 meter
Mainmade of 1.6mm
meter thick steel
board complete as nos 7 30015 210105
above for set of 2 quarters Main meter board complete as
9 Substation Equipments
9.01 MR TRANSFORMER:
Supply, Installation, testing and commissioning, of 800kVA, nos.
11kV HT VCB 3 Phase
PANEL , oilBOARD:
type transformer, 50 Hz Delta Star
Supply, Installation, Testing and Commisioning of High
Voltage Switchgear
Complete as above suitable for indoor installation 11 KV 3 nos. 1 305344 305344
9.03 MR HT XLPE Cable 11 KV:
Supplying, laying, testing & commissioning cable XLPE
3 C x 300screened
sq mm PVC bedded, galvanized steel strip or wire meter 100 3140.46 314046
Rate Amount Rate Amount
10 SAFETY ITEMS
10.01 MR Providing of Rubber mat 1 metre wide and 6mm thick to with mtrs 5 1841.22 9206.1
10.02 MR stand 3.3KV
Providing of dielectric
Rubber matstrength Latestwide
1 metre as perand
12mm thick to mtrs 5 2761.83 13809.15
10.03 MR withstand 15KV
Providing of Set dielectric
of 4 Nos. strength Latest asGIper
9 Litre capacity IS 15652.
bucket painted in nos 2 3129.77 6259.54
10.04 MR post office red
Supplying andcolour
ofprior coat of
Carbon red-oxide
dioxide (CO2)painttype
and fire 0 0 0
9 KG of 4.5 Kg each mounted on wall hooks confirming nos 4 10606.11 42424.44
10.05 MR Providing of First Aid Box as approved by St. John Ambulance nos 4 1012.98 4051.92
10.06 MR Brigade/Indian
and fixing Cross
Foamconforming to IS 2217-1963.
fire extinguishers, portable 9 litre Nos. 4 2407.63 9630.52
SUB TOTAL hanged on wall with bracket complete as required.
COMPACT SUBSTATION
Extra MR Supply & Installation of 11kV Compact Substation comprising Nos 0 2250000 0
Part KVA CRT dry type distribution transformer of same
SUB TOTAL (U) 0 450000
9.05 MR Supply, Installation, Testing, Commisioning (SITC) of 250 nos.
Extra MR KVA of D.G.
Supply, Set, complete
Installation, withCommisioning
Testing, engine, alternator, base of
Part of D.G. Set, complete with engine, alternator, base frame, 1 280000 280000
Extra MR Supply, Installation, Testing, Commisioning (SITC) of 200 nos. 0 1400000 0
Part of D.G. Set, complete with engine, alternator, base frame, 1 59000 59000
SUB TOTAL (V) 0 339000
External Lighting
Supp MR Supplying, Installation, Testing and Commisioning of 8 W LED Each 26 3864 100464
Supp MR BOLLARD
Supply, Housing made
Installation, up ofand
Testing aluminum pipe powder
Commisioning of coated
Standalone Solar LED Street lighting Blue tooth operated
SUB TOTAL (W) 0 900009
Extra MR AIR CONDITIONING WORKS
1.1 Supplying, Installation, Testing and Commisioning of BEE Nos 7 45000 315000
1.2 certified 2 TR
Supplying, (Carrier, O-Genral
Installation, Testing &and
Diakin) split type airof BEE
Commisioning Nos 13 37500 487500
1.3 certified 1.5 Installation,
Supplying, TR (Carrier, O-Genral
Testing and& Diakin) split type of
Commisioning air BEE Nos 20 30000 600000
1.4 certified 1.0
Supply, TR (Carrier,
Installation, O-Genral
testing and &commisioning
Diakin) split type
of aircopper RM 400 1239 495600
1.5 refrigerant
of Rigid PVCcomplete
Pipingwith elbowwith
complete bandfittings,
complete fittings as
supports RMT 400 212 84800
1.6 per specifications
epoxy coated stand insulated
for ODU with Units
for Split 6mm thickness of Nos 54 2183 117882
1.7 High Wall and Ducted Units 2X2.5sq.mm Copper Cable Rmt 350 104.4 36540
1.8 High Wall and Ducted Units 4X2.5sq.mm Copper Cable Rmt 350 168.2 58870
1.9 Supply of AC Stablizers
SUB TOTAL (X) 0 2196192
1.0 Supply, Installation, Testing & Commissioning of 10 Pair No. 0 725 0
Part Module as per given Specification etc. all complete.
2.0 Supply, Installation, Testing & Commissioning of 200 Pair No. 1 9465 9465
Part Box with Mounting Frame as per given Specification etc. 0 0 0
3.0 Supply, Installation, Testing & Commissioning of 25 Pair Mtr. 3830 315 1206450
Part Rate Riser cable as per given Specification etc. all 670 157.5 105525
4.0 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the No. 1418 34 48212
Part Ratesurface/ recessed steel/ PVC conduit as required 3032 10.2 30926.4
5.0 Supply, Installation, Testing & Commissioning of 100% Non No. 0 525000 0
Part Rate Fully Digital Integrated Services Digital 1 157500 157500
6.0 Supply, Installation, Testing & Commissioning of 16 Port No. 0 24180 0
Part Rate Card etc. all complete. 1 7254 7254
7.0 Supply, Installation, Testing & Commissioning of High End No. 1 25740 25740
Digital Key Phone 6x24 Display with 24 Programmable Dual 0 0 0
8.0 Supplying and fixing of following sizes of medium class PVC 0 0 0
conduit along with accessories in surface/recess including
SUB TOTAL (Y) 0 1780314.9
1.0 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the Mtrs. 4290 34 145860
Part Ratesurface/ recessed steel/ PVC conduit as required 4710 10.2 48042
1 Supplying and drawing of UTP 4 pair CAT 6A LAN Mtrs. 0 0 0
Part in the existing surface/ recessed steel/ PVC conduit as 0 0 0
2.0 Supplying, installing, testing and commissioning of Cat 6 , Tool Nos 100 315 31500
less Information outlet for Data,Voice & Wi-Fi. Cat6 U/UTP 0 0 0
2 Supplying,installation, testing and commissioning of Cat Nos 0 0 0
Part Ratestone including GI box 0 0 0
3.0 Supplying, installing, testing and commissioning of following Nos 150 210 31500
Part of Cat - 6 patch cord. 4 Feet : CAT6 UTP 23 AWG Patch
3 Supplying, installing, testing and commissioning of following Nos 0 0 0
length of Cat - 6A patch cord. 4 Feet : CAT6A UTP 23 AWG
Rate Amount Rate Amount
Part Rate 0 0 0
4.0 Supplying, installing, testing and commissioning of following Nos 150 230 34500
Part of Cat - 6 patch cord. 7 Feet : CAT6 UTP 23 AWG Patch
4 Supplying, installing, testing and commissioning of following Nos 0 0 0
Part of Cat - 6 patch cord. 7 Feet : CAT6A UTP 23 AWG
5.0 Supplying, installing, testing and commissioning of 24 port Cat Nos 2.333333 7615 17768.33333
Part panels available with block of four equipped with tool
5 Supplying, installing, testing and commissioning of 24 port Cat Nos 0 0 0
Rate panels available with block of four equipped 0 0 0
6.0 Supplying and fixing following Modular base & cover plate on Nos. 100 82 8200
existing modular metal boxes etc. as required. 0 0 0
8.0 Supplying and fixing of following sizes of medium class PVC 0 0 0
conduit along with accessories in surface/recess including Metre 2610 69 180090
6 2-port British-style shuttered faceplate for CAT 6A, WHITE Nos 0 0 0
Part Rate 0 0 0
BACKBONE CABLING 0 0 0
1.0 Supplying, laying and fixing of 6 core outdoor Singlemode Mtr. 2500 105 262500
Optical Fiber of size Outdoor Universal loose tube PVC jacket 0 0 0
1a Supplying, laying and fixing of 6 core outdoor Mtr. 0 0 0
1b Supplying, laying and fixing of 24 core outdoor Mtr. 0 0 0
2.0 Supplying, installing, testing and commissioning of 6 port Nos 12 7600 91200
3.0 LCS2 Adapter
Supplying, plate, loaded
installing, testingwith
and 6commissioning
nos. of duplex of
LCLIUunit24forport
4.0 LC type LCS2.
Supplying, Rack Mount
installing, testing19" modular
and type unloaded
commissioning to be
Supplying, SC Pigtails
installing, MM 50/125mn.
testing Approved Makes
and commissioning of 10 :- 0 0 0
GB - 50/125μm OM3 SC Pigtails MM 50/125mn. 0 0 0
5.0 Supplying, installing, testing and commissioning of SM Patch Nos 30 3300 99000
Cord - SC/LC Duplex Cords - 2 mtrs. Approved 0 0 0
5a Supplying, installing, testing and commissioning of MM Nos 0 0 0
6.0 Supplying, installing, testing and commissioning of Blanking Nos 36 450 16200
RACK and Modular Patch Panel (Size 6 X RJ45
ACCESSORIES 0 0 0
1.0 Supplying, installing, testing and commissioning of 15U Wall- Nos 7 9450 66150
2.0 mounting cabinets.
Supplying, sizetesting
installing, 771.35X600X500mm (HXWXD))
and commissioning with
of Cabinet. Nos 0 70800 0
Part 2026 X 800 X 800 mm (HXWXD) following accessories, 2 21240 42480
3.0 Supply, Installation, testing and commissioning of 1 U Nos 28 650 18200
Part Rate Wire Manager 60mm depth (Front Side) 2 195 390
Active Components 0 0 0
1.0 Supply, Installation, Testing & Commissioning of Core Switch Nos 0 548700 0
Part GbE SFP+ ports and 4 10GBASE-T/SFP+ combo ports, 1 164610 164610
2.0 Supply, Installation, Testing & Commissioning of 24 POE Nos 6 108000 648000
Part Rate ports+4 Gigabit SFP ports Switch Flow Control; 6 32400 194400
2a Supply, Installation, Testing & Commissioning of 24 Port Nos 0 0 0
2b 8 Port POE switch Nos 0 0 0
3.0 Supply, Installation, Testing & Commissioning of Modules Nos 22 26500 583000
Part Rate SX SFP, SF 220 & 550 meters, LC connector, 4 2650 10600
3a Supply, Installation, Testing & Commissioning of Modules Nos 0 0 0
Part Rate SX Multimode SFP, MMF 220 & 550 meters, LC 0 0 0
4.0 Supply , Installation , Testing and Comissioning of 3x3 Mimo Nos 0 34500 0
Part mbps to should work to Hardware controller. 75 8625 646875
5.0 Supply , Installation , Testing and comissioning of wilreless Nos 0 315000 0
Part ontroller supportable for 100 Aps in high availability 1 78750 78750
SUB TOTAL (Z) 0 3569426.333
GRAND TOTAL 172745768.6
GRAND TOTAL 172745768.6
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
1 NIT ISI final R1.pdf
Tender Document
3 Contracting GCC-April-2016.pdf
Tender Document
4 Technical_Specifications _ISI Tezpur.pdf
Tender Document
6 SCC.pdf
Tender Document
Approved makes merged.pdf
Tender Document
Amendment in GCC EMD.pdf
Tender Document
Amendment in GCC PBG.pdf
Tender Document
BOQ.pdf
Tender Document
corrigendum-282-Corrigendum 6.pdf
pdf • 0.17 MB
corrigendum-243-Corrigendum 5.pdf
pdf • 0.17 MB
corrigendum-242-Corrigendum 4 scc.pdf
pdf • 0.28 MB
corrigendum-236-Corrigendum 3.pdf
pdf • 0.17 MB
corrigendum-229-Corrigendum 2.pdf
pdf • 0.51 MB
corrigendum-222-Corrigendum 1.pdf
pdf • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .