GE AF JORHAT
GE AF JORHAT ASSAM
MANNING AND OPERATION INCLUDING COMPREHENSIVE MAINTENANCE OF OIL FIRED INCINERATOR ELECTRIC SUPPLY COMPLAIN CELL UNDER GE AF JORHAT
2021_MES_431424_1
8867/E8
Open Tender
Miscellaneous Services
Works
335 days
GE AF JORHAT
As per NIT
11 documents required · 11 mandatory
₹500
GE AF JORHAT
₹52,000
Yes
28 May 2021
18 Mar 2021
17 Apr 2021
18 Mar 2021
15 Apr 2021
1 Apr 2021
60 days
Amount
Manning & Operation, of Main Power House of 5AFH along with necessary operation of the following equipments including acessories like AMF Panel, Battery etc as and when required to keep continious electric supply round the clock in THREE SHIFTS OF 8 HOUR WITH Electrician (SK) PER SHIFT PER LOCATION including necessary day to day maintenence and attending daily electric supply complaints at 5AFH in all respect, routine maint, servicing, testing to attending external/ internal electric breakdowns and rpair complete all as specified and as directed by Engineer in charge. LIST OF EQUIPMENT INSTALLED AT POWER HOUSE AF HOSPITAL (a) HT VCB 800 AMPS -01 SET (b) LT ACB 800 AMPS -02 SET (c) LT PANEL BOARD -04 Nos. (d) AMF PANEL BOARD -02 Nos. (e) APFC PANEL BOARD 300 & 150 KVAR -02 Nos. (f) CHANGE OVER SWITCHES etc.
Manning & Opeation, day to day maintenance of following DG Sets including acessories like AMF Panel, Battery etc at Surgical Sub Stn to operate as and when required for THREE SHIFTS OF 8 HOUR WITH FGM (SK) PER SHIFT PER LOCATION including daily cheking of all electrical and mechinical parts complete all as specefied and as directed by Engineer in charge. LIST OF DG SET/ EQUIPMENT INSTALLED AT Surgical Sub Stn:- (a) 320 KVA DG Set(OT Complex) -01 SET (b) 125 KVA DG Set -01 SET (c) 200 KVA DG Set -04 Nos (d) 350 KVA DG Set -02 Nos (e) CHANGE OVER SWITCHES etc.
Manning and Operation for Oil Fired Incinerator including daily running Maintenance ie replacement of small spare parts, cleaning of plant, Change of Oil, replacement of filters, any type of pipe with fittings, maintenance of primary/secondary burner, cleaning of chambers, removing of ash, cleaning of scrubber, water tank, ventury and cleaning inside of scrubber, removing sludges, rust etc, well cleaning, Washing inside of scrubber and periodical checking of serviceability as and when required and rectify any defects immediately in all respect with ONE FGM (SK) PER SHIFT ( 8 HOURS PER SHIFT) to operate as and when required on ALL WORKING DAYS, including SUNDAYS & HOLIDAYS including daily minor maintenance to equipments in all respect complete all as specefied and as directed for Oil Fired Incinerator model HAATPD-3, Make : HOTMAX with panel, Air Blower, Exhaust system). NOTE : FOR ITEM NO. 1,2,3 AND 4 (a) The Term daily operation includes minor maintenance like adjustment of equipments, cleaning, recording of Hourly Reading in each plant. (b) log Sheets will be provided by contractor in standard performa to maintain the records with consulation to Engineer-in-Charge/ JE E/M. (c) Tools , screwdriver etc. are provided by contractor for attending day to day electrial complaints, maintenance and servicing. (d) POL for running of Oil Fired Incinerator shall be issued from MES store, free for operation, under schedule 'B' Rate for collecting/ shifting of POL from MES store to work site shall have to be quoted within the unit rate. (e) Contractor have to provide Grease, Gland and Gasket, Consumable Materials such as Soap, Cotton Waste, Protectuve clothing, Gloves and other Instruments, etc. as requred for Minor Maintenance, manning and operation of Installation from his own sources for which cost of the same shall deem to be included in the QUOTED UNIT RATE. NO EXTRA AMOUNT shall be PAID separately on this account. (f) The Contractor shall be responsible for MAKING GOOD if any damage occurred in installed machinaries/ equipment due to inadequate experience of the staff employed by him and/or negligence of his workmen.
M & L for Periodical Overhauling and greasing/ Oiling of entire Lift,Bed Cum Passenger Lift weight capacity 1360 Kgs (20 Passengers) including Hoist Way Material, Guide Rails, Car, Counter weight, Pulleys, Gear Box,and changing of gear oil etc as on when required including minor parts complete all as specefied and as directed by Engineer-in-Charge. Note : (a) Major Spare Parts will be Measured and paid separately under relevant items. (b) Testing will be carried out annually or as directed by License Holder Lift Engineer for safty of Lift as per IS Specifications in presense of Engineer-in-charge
Supply and Fixing of the following materials for Bed Cum Passenger Lift weight capacity 1360 Kgs (20 Passenge (a) Mother Board in elevator
(b) Power Supply Card 220 V
(c) Transformer 220V/9V
(d) Transformer 440V/135V
(e) Power Supply Card 110V
(f) UP/DN & IL Relay Card
(g) Car Operative Button Set with all accessories (For Lift car & Floor button)
(h) Landing Push button Set
(i) Gate Relay assembly set
(j) Gate bush for Lift Gate.
(k) Gate bearing of colapsible gate
(l) Gate shoe of collapsible gate
Replacement of Car Gate Contact Lock for Lift as per existing specification and fixed including Taking down old Unserviceable Car Gate Contact Lock, complete all as specified and as directed.
M&L Peparing Old Treated surfaces of any description and applying one Coat of White DUCO paint to Lift Cabin and one Coat of Black Synthetic Enamel Paint to Collaspsible Gate of Lift complete all as specefied and as directed.
S&F Elevator door detector (Infrared sensor) of capacity 188/988 A-AC 220 Volt in both side of door with one No power controller of capacity DC24 VIA or AC 120 VIA fix in existing position including taking down old unserviceable door detector complete all as specefied and as directed.
Supply & fixing in replacement of Battery 12 Volt 12 AH for existing ARD of lift at OT complete all as specefied and as directed by Engr-in-charge. (Make : EXIDE/ AMARON.
M&L for Periodical over Hauling of Oil Fired Incinerator with necessary Materials, Man Power and periodical checking of serviceability as and when required and rectify any defects noticed immediately in all respect, complete all as specefied and as directed. Note : (a) Major Spare Parts will be Measured and paid for separately under relevant items. (b) Testing will be carried out annually by License Holder for safty of Oil Fired Incinerator as per IS Specifications in presense of Engineer-in-charge
S&F testing in replacement of ID fan bearing No.22208K MB C3 W33, complete all as specified and as directed by Engineer-in-charge.
Replacement of Diesel Filter with Pipe and fittings as approved and suitable for Oil Fired Incinerator, Complete all as specefied and as directed.
Replacement of Gun metal gate valve with iron wheel head screwed both ends for iron pipe 50mm dia.all as specified
Supply and replacement of LED aviation light luminaries comprising of aluminium housing with red coloured polycorponate enclosure, 302 nos LED are provided,mounted on chimney with GI bracket 6mm thick with all acessories,electrically connecting up and testing complete all as specified and as directed by Engineer-in-charge.Make Cat No. BGAV 302 LED of Bajaj or equivalent from Phillips/Havells.
M&L Preparing Old treated Surfaces of any description and applying One Coat of Heat Resistant Metallic Paint to Oil Fired Incinerator, complete all as specified and as directed.
M&L Preparing Old treated Surfaces of any description and applying One Coat of Heat Resistant Metallic Paint to Chimney of Oil Fired Incinerator,making necessary scafolding arrangement upto 30 ft height, complete all as specified and as directed.
S&F Ventury outlet pipe assembly complete as per existing dimensions complete including lagging with glass wool and covering with aluminium sheet of thickness not less than 2.0mm including making all provisions and inter connecting ,including dismantling old unserviceable ventury out let pipe assembly complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of mild steel pipe of size 9" dia having length 11.5 feet long bend to shape both end jointed by gas welding and flanged intel and outlet both ends bend to 90 degree with heat resistant gasket to fit scrubber to ID Fan of chimney fixed after applying two metallic enamel heta resistant paint after a coat of red oxide primer fixed in existing position including dismantling of old rusted u/s MS pipe complete all as specified and as ditected by Engineer-in-charge
M&L for replacement of water tank of mild steel sheet of thickness 4mm, outer dia of 94" and vertical length of 50" and round shape as per existing dimensions joined by gas welding connecting with all inlet and outlet pipe flange and connecting with overflow drain system, including making all interconnections and fixed after applying a coats of red oxide primer including dismantling of old u/s wtare tank complete all as specified and as ditected by Engineer-in-charge
M&L for replacement of mild steel pipe of size 9" dia and 3 feet long connecting with droplet separator to watre tank with three Nos heat resistent gasket and two Nos of flange bend to shape and MS pipe to 10" dia 10" long from water tank to ventury fioxed in existing position including dismantling of rusted and u/s pipe fixing after applying two coats of metallic enamel heat resistant paint over a coat of red oxide primer using spray gun, complete as ditected by Engineer-in-charge Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
THE SUPPLY AGENCY
RAJIB AND CO
Bidder Name
THE SUPPLY AGENCY
RAJIB AND CO
M/S SANTOSHI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .