| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-Finance | ₹1.1 L | L1 | Accepted-Finance First lowest |
| 2 | L2₹1.1 LAccepted-Finance | ₹1.1 L | L2 | Accepted-Finance Second lowest |
| Sl No | Description | Qty | Unit | VIJAYAKUMAR EPWD CONTRACTOR L1 | RATHEESH R L2 |
|---|---|---|---|---|---|
| 1.00electrical works | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 1 | point | 1,689 ₹1,689 | 1,750 ₹1,750 |
| 1.00 | 1.7.1:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC
insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 16 | metre | 376 ₹6,016 | 400 ₹6,400 |
| 1.00 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 1 | each | 5,067 ₹5,067 | 5,100 ₹5,100 |
| 1.00 | OD260295/2025-2026:Supply and providing 9/12Watts inverter bulb, 100lumens/watts , B22type power back up upto 4hours | 10 | each | 509 ₹5,090 | 520 ₹5,200 |
| 1.00 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door | 1 | each | 2,962 ₹2,962 | 3,000 ₹3,000 |
| 1.01 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 1 | each | 1,345 ₹1,345 | 1,500 ₹1,500 |
| 1.01 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 500 ₹500 | 600 ₹600 |
| 1.01 | 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Double door | 1 | each | 2,540 ₹2,540 | 2,600 ₹2,600 |
| 1.01 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 2 | each | 294 ₹588 | 300 ₹600 |
Tender Value
Refer Docs
EMD Value
₹2,643
Closing Date
12 Jan 2026, 6:00 pmClosed
Assistant Executive Engineer
Assistant Executive EngineerPWD Electrical Subdivision, Palakkad
GENERAL-Landscapping and reconstruction and painting compound wall at Vadakkenchery rest house-motor pump set and connected works-General Electrical Work
2026_PWD_826615_1
ET-62/ESDPKD/2025-2026
Open Tender
Electrical Works
122 days
Palakkad
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹2,643
13 Feb 2026
8 Jan 2026
15 Jan 2026
8 Jan 2026
12 Jan 2026
8 Jan 2026
electrical works
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.7.1:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD260295/2025-2026:Supply and providing 9/12Watts inverter bulb, 100lumens/watts , B22type power back up upto 4hours
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
90.12.5.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
OD258480/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 4 sq. mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD258485/2025-2026:Supply and installation of SINTEX loop box GSJB-1510 with suitable bakelite connector and necessary connections as required
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD258489/2025-2026:Supply and Installation of 25W LED, Neutral white Colour, Integral pole-mounted decorative LED post top with spherical shaded polycarbonate diffuser and IP65 protection
OD258494/2025-2026:Supply and providing & fixing 9/12 Watts, b22 type ,cool day white LED bulb philips/osram/CG/eqt on exisitng battern holder
OD213281/2025-2026:Separate the motor and remove the whole burnt stator coil by cutting , pulling and cleaning the slots rewinding the complete the stator slots by using same gauge new super enamelled copper ,re assembling ,providing new lead wires, sockets etc. and test run the motor.
OD260290/2025-2026:Lowering down 1.5 HP submersible bore well motor pump set, position giving connections and trial run on full load
OD260291/2025-2026:Dismantling the 1.5HP submersible pump , removing the foreign materials from the pump, cleaning setting the impeller leaves, supply and greasing the bearings etc including leading to works hop charges to and fro
OD260292/2025-2026:Lifting the damaged 1.5HP motor from the open well submersible motor including all charges
OD244350/2025-2026:SITC of 1.5HP single phase ,180-220 Volt,50-60 Hz, OPEN well motor pump set suitable , Head Range 29M to 15M discharge range 350-25 lph Outlet size 32MM ,texmo/kirloscar/CRI/eqt including all accessories
OD260676/2025-2026:SITC of CG Power 120W/0.16 Hp Automatic Inline Pressure Booster Pump working in single phase suitable to existing washing machine, Operating range 180-240 V,Max Flow Rate:25 LPM (Liters Per Minute) or 1500 LPH, Max Head: 9 Meters ( (Model: CG-IPB120)/Eqt.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1386672.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tendernotice_2.pdf
PDF • 0.05 MB
NIT.pdf
Tender Documents • 0.03 MB
SBD.pdf
Tender Documents • 1.64 MB
BOQ_1386672.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid