| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.8 LAccepted-AOC | L1 | Accepted-AOC First lowest | |
| 2 | L2₹72.5 L+₹67,643.16 (0.94%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹74.9 L+₹3.1 L (4.38%)Rejected-AOC | L3 | Rejected-AOC Third lowest |
Tender Value
₹84.7 L
EMD Value
₹50,000
Closing Date
3 Jul 2024, 2:00 pmClosed
Executive Engineer
O/o Executive Engineer, PWD Buildings division, Idukki
DEPOSIT-Construction of Protection wall for Pre metric hostel Irumbupalam-General Civil Work
2024_PWD_678080_1
02/EE/BL/IDK/2024-25
Open Tender
Civil Works - Buildings
Item Rate
270 days
Irumbupalam
Please refer tender documents
10 documents required · 10 mandatory
₹2,760
Yes
₹50,000
Yes
21 Aug 2024
27 Jun 2024
5 Jul 2024
27 Jun 2024
3 Jul 2024
27 Jun 2024
Amount
Protection wall
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
OD15632/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is not payable separately. All work up to plinth level
OD15633/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions asper IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is not payable separately. All work above plinth level up to floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD106545/2022-2023:Providing and fixing PVC pipes for using weep holes as per direction of Engineer in-charge 75 mm dia 6kgf/cm2 -external work-including all labour charges etc complete.
OD15888/2024-2025:Assembling, jointing and laying of synthetic non woven water permeable Geo-textile at the rear side of retaining wall in between gravel filter media and earth as per the specification & drawing.
OD15887/2024-2025:Supplying, filling, spreading and levelling stone boulders of size range 5cm to 20cm in filter media in the required thickness for all leads and lifts etc. all complete as per the direction of Engineer-in-charge
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Road concreting
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
MANESH JACOB
BENNY JOSEPH
Bidder Name
Binu MG
MANESH JACOB
BENNY JOSEPH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1054467.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .