Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹7,740
Closing Date
28 Oct 2026, 1:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Renovation to the E.I. Work of Ground Floor Pathology Room of L.D.V Hospital Kolkata.
2026_WBPWD_5078647_1
WBPWD/AE/KMCESD/NIQ-40/26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,740
8 Oct 2026
8 Oct 2026
30 Oct 2026
9 Oct 2026
28 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Part I: Electrical Installation work.
A. Distribution wiring:---
Dismantling the existing E.I. work by Co's own tools & tackles and remove unnecessary,scrap items away from site by maintening normalcy as far as possible and deposit necessary materials to section office as per direction of EIC . | 1 | item | - | - |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C | 12 | pt | - | - |
| 3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | |||||
| 3.1 | b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | - | RM | - | - |
| 3.2 | c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | - | RM | - | - |
| 3.3 | d) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 20 | RM | - | - |
| 4 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5 sqmm | 24 | Each | - | - |
| 4.1 | b) 4 sqmm | 16 | Each | - | - |
| 4.2 | c) 6 sqmm | 8 | Each | - | - |
| 5 | B. BDB, PDB, VTPN etc:---
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (4 + 18), Double door | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
suspension.pdf
Additional Documents • 2.91 MB
2911_Form.pdf
Tender Documents • 0.50 MB
BOQ_5179310.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .