Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
4 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS 2
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; Where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. The Definition of similar nature in this tender means "Any Electrical work related to HT/LT installations". (Authority: PCEE / NWR / JP letter No EL/50/0/SNW/Vol.I Dtd. 08.01.2016).
3 conditions · 1 needing a document upload
Bidder / Tenderer should submit GST registration certificate along with PAN card & Bank mandate while bidding / uploading tender documents.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions.
(i) Electrical Work in c/w Provision of centralised monitoring control building with arrangements for unified NMS of Kavach , EI networking, centralised exchange- VOIP an DIP-MPLS, NMS, RDPMS, CCTV etc in Jodhpur DRM Office. (ii) Electrical Work in c/w strengthening / provision of telecom store with office facilities for SSE/JE Telecom at 11 locations and TCM duty room at 23 locations over JU division. (iii) Electrical Work in c/w provision of signal store with other facilities for SSE/JE signal at 28 locations and ESM duty room at 19 locations over JU division
24Rof2026-27~NWR
24Rof2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹2.9 L
13 Oct 2026
13 Oct 2026
21 Oct 2026
127 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,44,08,582.9 | ||
| — | 20.00 | — | — | ||
| Installation of wall mounted split Air Conditioner of capacity 1.0/1.5/2.0 TR indoor and outdoor unit as per specification(Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 95,163.6 | |
| — | 3550.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x6 sq mm PVC insulated multi-strand ( 84 /.30 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required.(Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,38,673.5 | |
| — | 6300.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x4 sq mm PVC insulated multi-strand ( 56 /0.3 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm as per specifications attached as required.(Inspection- RITES , Inspection Charges - To be borne by railway) | — | — | — | 5,50,935 | |
| — | 9600.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x2.5 sq mm PVC insulated ( 36 /0.3 mm ) multi-strand copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required (Inspection- RITES , Inspection Charges - To be borne by railway) | — | — | — | 6,59,328 | |
| — | 12600.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class P.V.C. Pipe along with accessories as required in recess on walls/roof properly including cutting of wall /roof and making good the damages as per specifications attached. (Inspection- RITES , Inspection Charges - To be borne by railway) | — | — | — | 10,07,496 | |
| — | 1200.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class PVC Pipe along with accessories as required in surface on walls/roof properly with saddles and wooden gutties etc. complete as per specifications attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 62,868 | |
| — | 72.00 | — | — | ||
| Supply, install, test & commission of Modular USB charger for Mobile Charging, 300mA/15watts, Type (A+C), Single module. As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 69,444.72 | |
| — | 152.00 | — | — | ||
| Supply, install, test commission of 12Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 88,885.04 | |
| — | 175.00 | — | — | ||
| Supply, install, test commission of 8Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 66,781.75 | |
| — | 194.00 | — | — | ||
| Supply, install, test commission of 4Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 55,806.04 | |
| — | 100.00 | — | — | ||
| Supply, install, test commission of 3Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 21,897 | |
| — | 87.00 | — | — | ||
| Supply, install, test &commission of 2 Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 15,803.55 | |
| — | 330.00 | — | — | ||
| Supply, install, test &commission of Modular 6amp, 5 Pin Socket asper specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 44,196.9 | |
| — | 460.00 | — | — | ||
| Supply, install, test commission of Modular6amp one way/SP Switch, ISI marked asper specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 32,273.6 | |
| — | 172.00 | — | — | ||
| Supply, install, test commissioning of Modular 16 amp, 3/3(6Pin) Socket as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 37,060.84 | |
| — | 172.00 | — | — | ||
| Supply, install, test commission of Modular16 amp one way/SP Switch , 2 Modular ,ISI marked including connection / wiring on lighting switch board asper specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 25,413 | |
| — | 153.00 | — | — | ||
| Supply, install, test &commission of Modular blank plate as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,903.32 | |
| — | 217.00 | — | — | ||
| Supply, install, test commission of Modular type Fan regulator (5step , 2 Modular) including connection/wiring on lighting switchboard as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,08,274.32 | |
| — | 2080.00 | — | — | ||
| Recessed/Surface conduit wiring system-Supply of material and wiring ofLP/TP/FP/Exhaust fan/ Bell point with single core multistrand copper conductor size 1.5 Sq.mm in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc. As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 8,65,820.8 | |
| — | 84.00 | — | — | ||
| Supply, testing, fixing &commissioning of modular Exhaust fan 200-300 mm sweep 1200-1440 RPM and as per specification attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,91,068.92 | |
| — | 6.00 | — | — | ||
| Supply, install, test & commission of 63A 100mA 4P RCCB for incoming in DB. As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 20,928 | |
| — | 6.00 | — | — | ||
| Supply, install, test & commissioning of 4 way TPN-DB (8+12) double door. As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 14,748 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing &commissioning of VTPN type metal double door type 8 way DB with having 01 No. 250Amp., 4 pole MCCB, 36 KA as incomer & 8 Nos. TP MCB, 10KA 'C' curves, 40-63 Amp. Cap. as outgoing having suitable IP-54, IK-09protection as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,05,205.74 | |
| — | 1.00 | — | — | ||
| Supply, installation ,testing & commissioning of MDB with three phase electronic Energy meter, digital ampere meter with CT, selector switch, suitable digital voltmeter and indication lamp with following incoming & outgoing Incoming- MCCB 4 pole 400A,35KA 2 Nos. Outgoing- MCCB 4pole 250A,35KA-06Nos. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,41,956.19 | |
| — | 880.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB (SP-) 6-32A (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,11,552 | |
| — | 130.00 | — | — | ||
| Supply, Fixing of RCCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-RCCB - 25 A/30mA (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,29,488.9 | |
| — | 130.00 | — | — | ||
| Supply. fixing, testing and commissioning of SPN DB 8-way with provision of incoming MCB of 63A,IP 43/IK09, double door at suitable locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,33,193.9 | |
| — | 9.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB(TPN)-63A (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 18,925.56 | |
| — | 27.00 | — | — | ||
| Supply, Fixing, testing and commissioning of VTPN DB 8-way with provision of incoming MCCB of 125A, IP43/IK09, double door at suitable locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,16,312.46 | |
| — | 27.00 | — | — | ||
| Supply, Fixing of MCCB to be provided in the VTPN given above including supply of material as required & as per specifications attached- MCCB 4-pole 100/125A, 25 KA as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,74,865.3 | |
| — | 43.00 | — | — | ||
| Supply, Fixing of MCB TP 63A to be provided in the MCB DB including supply of material as required & as per specifications attached (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 89,734.98 | |
| — | 600.00 | — | — | ||
| laying cable in Air/Wall/Pole already excavated trench etc with fixture(02 nos. per mtrs) as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 14,592 | |
| — | 300.00 | — | — | ||
| Drilling of horizontal bore below track/road by pushing method for laying of RCC/HDPE/DWC pipe of various sizes (As per specifications) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,27,278 | |
| — | 300.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 160 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,37,129 | |
| — | 4250.00 | — | — | ||
| Supply and laying of HDPE pipe confirming to IS 4984:1995, 50 mm dia, wall thickness 3 mm, PN 6 under the road. The work involves laying of HDPE pipe. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,19,135 | |
| — | 6500.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec ( trench work may be on kuchcha/ pucca land and all type of soil as per site requirement and without protective layer of brick). Surface of trench shall be made good in all respect and satisfaction of site engineer. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,64,485 | |
| — | 2250.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 110 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection- RITES , Inspection Charges - To be borne by railway) | — | — | — | 6,82,065 | |
| — | 6.00 | — | — | ||
| J' type cable route marker made of cast iron as per approved Railway drawing. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,339.98 | |
| — | 20.00 | — | — | ||
| Supply & fixing of 7W LED Tiltable Mirror light in Aluminium body with glass cover in sand gray finish in 6000k, Approx dimension 320x78x28mm,catalogue no. LLT 004 (make Ledlum, Bajaj, Wipro or equivalent) as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 15,895.2 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mmthicksize 600x300x600mmwithsuitable MS stand Copper busbar of 200Acapacity and 2x63AMCB 4pole as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 23,035.32 | |
| — | 59.00 | — | — | ||
| Supply, install, test & commission of Ray roll plug socket 20amp SPN Ray Roll Plug socket including connection /wiring of "C" series 32 amps SP-MCB as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 52,857.51 | |
| — | 58.00 | — | — | ||
| Supply, Testing & Fixing of wall mounted cabin fan with regulator three speed, suitable for 220-230 volt ,50HZ AC supply .Model No-Media BW 04 of Bajaj or similar to Usha/ Crompton Greaves /Philips or similar. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,12,195.78 | |
| — | 68.00 | — | — | ||
| Supply of MCB 2 pole, 16 Amps, 240 Volts, AC breaking capacity 10 KA with time current, Characteristics for C curves as per IS 8828- CM/L-7222457, confirms to IEC-60898, MCB should be IP-20 protection, Make- legrand/ ABB/Schneider or similar (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 23,188 | |
| — | 50.00 | — | — | ||
| Supply of Miniature Circuit Breaker 32 2 P with 2 PP as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 35,000 | |
| — | 42.00 | — | — | ||
| Supply of MCB (63 A, 4-pole, C-curve, 10 kA breaking capacity, IS/IEC 60898-1:2002) as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 92,379.84 | |
| — | 860.00 | — | — | ||
| Assembling, fixing, hanging and making connection of Surface pendent mounted box type tube light fitting/street light fitting as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 61,920 | |
| — | 97.00 | — | — | ||
| "B" Class 50 mm dia GI pipe earth Station with digging pit & refilling with charcoal & salt as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,34,330.45 | |
| — | 97.00 | — | — | ||
| Inspection Chamber with cover as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 37,406.11 | |
| — | 970.00 | — | — | ||
| Supply & laying of earth connection from earth electrode with 4 mm GI wire properly fixed on wall with wooden gutties etc. as required. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 11,368.4 | |
| — | 340.00 | — | — | ||
| Supply of material & commissioning of PVC casing caping 25X12 mm with accessories for surface wiring as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 8,313 | |
| — | 60.00 | — | — | ||
| Supplying., laying of GI pipe size 50 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 20,644.8 | |
| — | 630.00 | — | — | ||
| Supply, installation, testing & commissioning of (100 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and having cover on it and all hardware complete as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,45,214.7 | |
| — | 50.00 | — | — | ||
| Supply & installation of Air cooled VRF outdoor unit complete with indoor & outdoor units, as per specification. Refrigerant R-410A, modular type top discharge outdoor unit with multi scroll/twin rotary compressors with fully inverter type compressor, suitable for 320V-460V 50Hz, with auto address setting, auto check function, sandwich type vibration isolator rubber pads. Capacity as per Railway requirement. (1 HP = 1 Nos) As per specification (Inspection- RITES , Inspection Charges - To be borne by contractor) | — | — | — | 12,73,322 | |
| — | 30.00 | — | — | ||
| Supply & installation of Air cooled VRF Hi-wall type indoor unit 1.5/2.0 TR As per specification (Inspection- RITES , Inspection Charges - To be borne by contractor) | — | — | — | 9,24,894.9 | |
| — | 30.00 | — | — | ||
| SITC of cordless remote controller As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 30,641.4 | |
| — | 40.00 | — | — | ||
| SITC of copper distribution joint kit As per specification (Inspection- Consignee ,Inspection Charges- Nil ) | — | — | — | 2,26,854.4 | |
| — | 600.00 | — | — | ||
| SITC of control cabling: Supply & installation of control & transmission wiring between indoor & outdoor unit As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 97,110 | |
| — | 600.00 | — | — | ||
| SITC of Refrigerant piping: Supply & installation of copper refrigerant piping of required sizes with nitrile insulation As per specification (Inspection- RITES , Inspection Charges - To be borne by contractor) | — | — | — | 8,40,072 | |
| — | 50.00 | — | — | ||
| Drain piping; SITC of rigid PVC piping complete with fitting, supports & duly insulated nitrile rubber insulation 32 mm dia As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 11,689 | |
| — | 30.00 | — | — | ||
| Drain piping; SITC of rigid PVC piping complete with fitting, supports & duly insulated nitrile rubber insulation 25 mm dia As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 6,138 | |
| — | 30.00 | — | — | ||
| Supply of gas charging refrigerant R-410A as per OEM design parameter (each cylinder gas 45 Kg) & testing As per specification. (Inspection- RITES , Inspection Charges - To be borne by contractor) | — | — | — | 10,64,217 | |
| — | 10.00 | — | — | ||
| SITC of MS stands As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 45,398.9 | |
| — | 12.00 | — | — | ||
| Supply installation, testing and commissioning of 0.5 HP Mono block Pump as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 72,467.28 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1TO12newCOMPRESSED.pdf
ATTACHMENT
SORTECHNICALSPEC24Rof202627
ATTACHMENT
TD24Rof26-27.pdf
ATTACHMENT
SORSNTcentralisedbuildingNIT24Rof26-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .