| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | Admitted-Finance |
| 2 | Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | Admitted-Finance |
| 3 | Admitted-Finance DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | Admitted-Finance |
| 4 | Admitted-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | Admitted-Finance |
| 5 | Rejected-Technical D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | Rejected-Technical The bidder has revoked his offer vide letter No. Nil dated 18 Jul 2024 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
11 Jul 2024, 6:00 pmClosed
GE U-II Vizag
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
RELOCATION SHIFTING OF WATER SUPPLY PIPELINE FOR RUNWAY RESURFACING AND DEVELOPMENT INFRASTRUCTURE AT INS DEGA PROVISION OF FRESH WATER SUPPLY PIPELINE FOR SUBMARINE ESCAPE TRAINING TOWER SETT AT ESCAPE TRAINING SCHOOL INS SATAVAHNA SPECIAL REPAIR RE
2024_MES_657105_1
8976
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Utility-II
₹87,000
Yes
24 Jul 2024
3 Jun 2024
13 Jul 2024
3 Jun 2024
11 Jul 2024
24 Jun 2024
3 Jun 2024 - 10 Jun 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth and getting out soft / loose soil for laying of cables, pipes etc, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, complete all as specified and as directed.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
Taking down old unserviceable GI pipe of 80mm dia including fittings complete all as specified.and directed.
Supply and fix 80 mm bore GI tubes, medium grade, galvanised with all fittings and fixed/laid in trenches complete all as specified.and directed. Note: Earth work shall be measured and paid separately under relevant items.
Supplying and laying 150 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with Spigot and Socket ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating, complete all as specified and as directed.
Supplying and laying 100 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with Spigot and Socket ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating complete all as specified and as directed.
Supplying and fixing DI fittings such as bends [any type and angle], tapers any type [straight, bend, increasing, decreasing or double socket etc], sockets, tail pieces, connecting pieces, tee pieces, single branch, "Y" junction, double branch, cross, [all sockets or socket and spigot], collars, caps and plugs of size upto 150mm bore confirming to IS 9523-2000, complete all as specified and as directed.
S & F in repairs Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, 100 mm Dia, confirming to IS – 14846, Class PN –1.0,Non raising type, Long Body including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer, complete all as specified and as directed.
S & F in repairs Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, 80 mm Dia, confirming to IS – 14846, Class PN –1.0,Non raising type, Long Body including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, washer, complete all as specified and as directed.
S & F in repairs 150mm bore Cast Iron Double Outlet Air Valve, with Flanged End conforming to IS – 14845 fixed to DI water supply mains with necessary rubber insertion sheet, bolts, nuts & washers including taking down existing valve of any description, complete all as specified and as directed.
M & L for Cutting the existing road/PCC hard standing for taking out/laying of pipe including making good the existing surfaces with same finish to match the original finish, complete all as specified and as directed.
M & L for Plain cement concrete Type C1 [Nominal Mix] 1:3:6 using 20mm graded stone aggregate Base foundation of Pipe Line, Bed Blocks or Copings or Bed Plates etc including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, including applying three coats of white washing and Demolition of existing Cement Concrete bed block/coping of any size and any description and removing rubbish to a distance not exceeding 1.50 KM, complete all as specified and as directed.
M & L for construction of valves pit chamber having intermal dimention 100 cm x 100 cm x 100 cm (internal height) using PCC (1:4:8) 40mm graded stone aggregate for foundation 15 cms. Thick, 23 cm tick wall in CM (1:4), 10mm tick rendering all around the brick work with 1:6 cement mortar, PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm tick MS top sheet cover with locking arrangement including 50mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surpuls soil to a distance not exceeding 50 mtrs all as specified and includung demolition/ dismentling of existing valve chamber, complete all as specified and directed.
M & L for Cutting/drilling of CI/DI/MS pipe of size 200 MM bore and inserting 150/100 mm dia pipe including all fittings, complete all as specified and directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note:- The punned down thickness shall be measured for payment.
Supplying and laying bricks in trenches, fly ash bricks laid flat as cable cover, complete all as specified and as directed.
Dismantling of existing old U/S BER DG Set with complete with all accessories from the existing arrangement and transporting the same to MES Store yard, complete all as specified and directed.
Supply, Install, Testing and commissioning of Silent Diesel Engine driven Generating Set of Capacity 75 KVA /60 KW, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364, conforming to CPCB IV approved norms complete with relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS and foundation etc. including following: Make: Greaves Cotton/Kirloskar Green / Cummins / Ashok Leyland
A. ENGINE: Direct Injection, Turbo charged Water Cooled Engine, 3 Cylinder, in-line, 4 Stroke developing suitable BHP but not less than 103.4 HP(Gross Engine Power) @ 1500 RPM complete with a provision of 10% over load for one hour , conforming to BS – 5514 and having following specifications: [i] In- line fuel pump with Electronic Governor for [ii] Stainless Steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI Sheet Cladding & extended outside the building. [iii] Silencer [iv] Radiator [v] Coolant Inhibitor [vi] Plate type Lub Oil Cooler [vii] Spin-On-Filters-Coolant, Fuel, Fuel & Lub Oil [viii] Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restriction Indicator [ix] Flywheel Housing and Flywheel to suit Single Bearing Alternator [x] Electrical Starter Motor [xi] Battery Charging Alternator [xii] 1 X 12 Volts Batteries, 88 AH Capacity or higher capacity as recommended by OEM. [xiii] First fill of Lub Oil.
B. ALTERNATOR: [i] Self Excited & Self Regulated [ii] Voltage Regulation ± 1 % [iii] Class H Insulation [iv] 4 Pole rotating Field [v] Digital Automatic Voltage Regulator [vi] Standard Enclosure IP-23 [vii] Telephone Interference Factor: 50 [viii] Total Harmonic Factor: Better than 2% [ix] Supplying power to variable electrical load for unlimited hours. Prime Power [PRP] is in accordance with ISO 8528. 10% over load capacity for one hour every 12 Hours of operation and will be suitable for tropical condition. (x) Unbalanced load capability is 25 percent of rated power.
C. ENGINE CONTROL WITH AMF PANEL: Standard Control Panel along with DG Set, Cubicle with CRCA Sheet of 2 mm thick and angle iron structure including following accessories: [i] MCCB, FP, 125 Amps – 3 Nos. [ii] Contactor, 4 Pole, 125 Amps capacity – 2 Nos [iii] Contactor, 4 Pole,125 Amps capacity – 1 Nos for Neutral [iv] Microprocessor based LED type Multifunctional Intelligent Panel Meter for showing Current, Voltage, Frequency, Power Factor, Energy Consumed, Speed, Temperature of Engine, Oil Level, Battery Voltage,Battery Charger etc. [v] Digital Frequency Meter – 1 No [vi] Digital Power Factor Meter with CTs – 1 No [vii] Three Phase, 400 / 5 CT Operated Digital KWH Meter 160 Amps – 1 No [viii] Indicating Lamps for "DG ON & LOAD ON" [ix] Instrument displaying Water Temperature, Lube Oil Pressure, Engine RPM, Battery Charging. [x] PVC Sleeve insulated Tinned Aluminium bus Bar suitable for 300 Amps current carrying capacity [TPN] [xi] Instrumentation, Control Switch Fuses / MCBs duly wired and ferruled. [xii] Coolant Heater with Thermostatic Switch [xiii] Lub Oil Heater
D. FUEL TANK: In-Built Fuel Tank of suitable capacity not less than 130 Litres capacity with all fittings and accessories. E. ACOUSTIC ENCLOSURE: [i] Designed to meet stringent MOEF / CPCB norms 75 dBA @ 1 m at 75% load under free field conditions. [ii] Air Inlet Louvers shall be designed to operate at rated load even at 50°C Air Inlet Temperature. [iii] Cubicle shall be powder coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment. Stain Steel hardware shall be used. [iv] Insulation Material shall meet / conform to IS – 8183 Specifications for better sound attenuation [v] Provision of Genset Controller for Engine & Alternator. F. ACCESSORIES: [i] Periodical Maintenance Tools as per Manufacture [ii] Operational, Spare Parts, & Installation Guidelines and Catalogue.
Note for Serial Item No. 1: Quoted rate shall deemed to be inclusive of followings: [i] Provision of 200mm thick PCC 1:1½:3, Type A1, using 20mm graded stone aggregate Foundation over 200mm thick PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 200mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick complete as per manufacturer's instructions with Anti-Vibration Mounting Pads as per manufacturer’s guidelines including necessary earthwork excavation, return filling, removal surplus soil and applying two coats of Cement Based paint over a coat of Alkali Resistant Primer complete etc. complete all as directed. [ii] Testing of DG Set shall be carried out by the IEM or rep of accepting officer. [iii] Artificial load i.e. strip heaters of suitable capacity to be made available during test. [iv] Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for ACB’s / MCCB's if required. [v] U/G cable shall be laid / connected to DG Set Cubicle Panel to AMF Control Panel [Changeover Panel] all as specified.
[vi] Provision of cable gland & Aluminium lugs of suitable size for terminating the cable at both ends. [vii] DG Set shall be covered with Galvalume Sheet Roofing / Canopy of minimum size of 3.5m X 1.9 m X 2.5m with pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size and using Mild Steel Tubular Trusses, Posts, Frame work etc. including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS - 1161, Grade YST - 240, Medium Grade of approved sections complete all as directed and the rate quoted shall be deemed to be included for the same. [viii] Exhaust Pipe shall be insulated with 25mm thick Resin Bonded Fibre Glass Wool of density 32 kg/Cu.m and wrapped with 24 SWG Aluminium sheet duly painted with approved colour & quality complete as per ISO 8528 and 3046 / BS 5514 Specification and IS – 4722 and IS – 1460 complete all as specified.
Supplying, laying and testing XLPE insulated and PVC sheathed, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 70 Sqmm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description, complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 240 Sqmm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description, complete all as specified and as directed.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description, complete all as specified and as directed.
S & F change over switch 4 pole 315 A in sheet metal enclosures, complete all as specified and as directed.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 1, Flat, of size 300mm x 180mm x 40mm, complete all as specified and as directed.
Supply, Install, Testing and commissioning of Silent Diesel Engine driven Generating Set of Capacity 160 KVA /128 KW, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364, conforming to latest CPCB-IV complete with relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS and foundation etc. including following: Make: Greaves Cotton/Kirloskar Green / Cummins / Ashok Leyland
A. ENGINE: Direct Injection, Turbo charged Water Cooled Engine, 4 Cylinder, in-line, 4 Stroke developing suitable BHP but not less than 155.1 HP(Gross Engine Power) @ 1500 RPM complete with a provision of 10% over load for one hour,conforming to BS – 5514 and having following specifications: [i] In- line fuel pump with Electronic Governor for [ii] Stainless Steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI Sheet Cladding & extended outside the building. [iii] Silencer [iv] Radiator [v] Coolant Inhibitor [vi] Plate type Lub Oil Cooler [vii] Spin-On-Filters-Coolant, Fuel, Fuel & Lub Oil [viii] Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restriction Indicator [ix] Flywheel Housing and Flywheel to suit Single Bearing Alternator [x] Electrical Starter Motor [xi] Battery Charging Alternator [xii] 1 X 12 Volts Batteries, 88 AH or higher capacity as recommended by OEM. [xiii] First fill of Lub Oil.
B. ALTERNATOR: [i] Self Excited & Self Regulated [ii] Voltage Regulation ± 1 % [iii] Class H Insulation [iv] 4 Pole rotating Field [v] Digital Automatic Voltage Regulator [vi] Standard Enclosure IP-23 [vii] Telephone Interference Factor: 50 [viii] Total Harmonic Factor: Better than 2% [ix] Supplying power to variable electrical load for unlimited hours. Prime Power [PRP] is in accordance with ISO 8528. 10% over load capacity for one hour every 12 Hours of operation and will be suitable for tropical condition. (x) Unbalanced load capability is 25 percent of rated power.
C. ENGINE CONTROL WITH AMF PANEL: Standard Control Panel along with DG Set, Cubicle with CRCA Sheet of 2 mm thick and angle iron structure including following accessories: [i] MCCB, FP, 200 Amps – 3 Nos. [ii] Contactor, 4 Pole, 200 Amps capacity – 2 Nos [iii] Contactor, 4 Pole, 200 Amps capacity – 1 Nos for Neutral [iv] Microprocessor based LED type Multifunctional Intelligent Panel Meter for showing Current, Voltage, Frequency, Power Factor, Energy Consumed, Speed, Temperature of Engine, Oil Level, Battery Voltage, Battery charger etc. [v] Digital Frequency Meter – 1 No [vi] Digital Power Factor Meter with CTs – 1 No [vii] Three Phase, 400 / 5 CT Operated Digital KWH Meter 160 Amps – 1 No [viii] Indicating Lamps for "DG ON & LOAD ON" [ix] Instrument displaying Water Temperature, Lube Oil Pressure, Engine RPM, Battery Charging. [x] PVC Sleeve insulated Tinned Aluminium bus Bar suitable for 300 Amps current carrying capacity [TPN] [xi] Instrumentation, Control Switch Fuses / MCBs duly wired and ferruled. [xii] Coolant Heater with Thermostatic Switch [xiii] Lub Oil Heater
D. FUEL TANK: In-Built Fuel Tank of suitable capacity but not less than 200 Litres capacity with all fittings and accessories. E. ACOUSTIC ENCLOSURE: [i] Designed to meet stringent MOEF / CPCB norms 75 dBA @ 1 m at 75% load under free field conditions. [ii] Air Inlet Louvers shall be designed to operate at rated load even at 50°C Air Inlet Temperature. [iii] Cubicle shall be powder coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment. Stain Steel hardware shall be used. [iv] Insulation Material shall meet / conform to IS – 8183 Specifications for better sound attenuation [v] Provision of Genset Controller for Engine & Alternator. F. ACCESSORIES: [i] Periodical Maintenance Tools as per Manufacture [ii] Operational, Spare Parts, & Installation Guidelines and Catalogue.
Note for Serial Item No. 16: Quoted rate shall deemed to be inclusive of followings: [i] Provision of 200mm thick PCC 1:1½:3, Type A1, using 20mm graded stone aggregate Foundation over 200mm thick PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 200mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick complete as per manufacturer's instructions with Anti-Vibration Mounting Pads as per manufacturer’s guidelines including necessary earthwork excavation, return filling, removal surplus soil and applying two coats of Cement Based paint over a coat of Alkali Resistant Primer complete etc. complete all as directed. [ii] Testing of DG Set shall be carried out by the IEM or rep of accepting officer. [iii] Artificial load i.e. strip heaters of suitable capacity to be made available during test. [iv] Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for ACB’s / MCCB's if required. [v] U/G cable shall be laid / connected to DG Set Cubicle Panel to AMF Control Panel [Changeover Panel] all as specified.
[vi] Provision of cable gland & Aluminium lugs of suitable size for terminating the cable at both ends. [viii] Exhaust Pipe shall be insulated with 25mm thick Resin Bonded Fibre Glass Wool of density 32 kg/Cu.m and wrapped with 24 SWG Aluminium sheet duly painted with approved colour & quality complete as per ISO 8528 and 3046 / BS 5514 Specification and IS – 4722 and IS – 1460 complete all as specified. [vii] DG Set shall be covered with Galvalume Sheet Roofing / Canopy of minimum size of 4.3m X 2.2m X 3m with pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size and using Mild Steel Tubular Trusses, Posts, Frame work etc. including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS - 1161, Grade YST - 240, Medium Grade of approved sections complete all as directed and the rate quoted shall be deemed to be included for the same.
SCHEDULE OF CREDIT Note :- Amount of Rs. 10,600.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
SRI SRK ENGINEERS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
Prasad and Suresh Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .