Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.1 CrAccepted-AOC | ₹89.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹89.2 CrRejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹89.2 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹98.9 CrRejected-Finance A 104 SYMPHONY PLOT NO 9 NEAR SAHJANAND CHOWK HARMU HOUSING COLONY HARMU RANCHI JHARKHAND | ₹98.9 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹104.4 CrRejected-Finance | ₹104.4 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹107.1 CrRejected-Finance KALIKA GUNJ COLONY SIRSIA GIRIDIH JHARKHAND | GIRIDIH | JHARKHAND | 815301 | ₹107.1 Cr | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹95.0 L
Closing Date
5 Apr 2024, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Office of the State Project Director, Jharkhand Education Project Council, JSCA Stadium Road, Sector III, Dhurwa, Ranchi-834004
Construction of Residential School based on Netrahat Awasiya Vidyalaya, Netrahat/Indira Gandhi Balika Awasiya Vidyalaya, Hazaribagh at Khuntpani located in West Singhbhum District of Kolhan Division of Jharkhand.
2024_HRD_85345_1
JEPC/CIV/03/887/2024/619
Open Tender
Civil Works - Buildings
730 days
West Singhbhum
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹95.0 L
23 Dec 2024
9 Mar 2024
8 Apr 2024
9 Mar 2024
5 Apr 2024
9 Mar 2024
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or in plinth including thick with all leads and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted voume)
Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I. Terrace Floor
Providing randam rubble stone masonry in CM (1:6) in foundation and plinth with hammer dressed stone of less than 0.03 M3 in volume and clean coarse sand of F.M. 2 to 2.5 including cost of screening raking out joints to 20 mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing randam rubble stone masonry in CM (1:6) in superstructureincluding cost of screening of materials scaffolding raking out joints to 20 mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
Extra for shuttering in circular work (20% of respective centering and shuttering items)
Column
Centering and shuttering including strutting, propping etc. and removal of form for Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Edges of slabs and breaks in floors and walls Under 20 cm wide
Cornices and mouldings
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.50 mm thick
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable / recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing precast R.C.C. M-150 with nominal mix of (1:2:4) slab of desired size with approved quality of stone chips and clean coarse sand of F.M. 2.5 to 3 including curing , shuttering carring the slab manually to site and laying in position all complete ( but excluding the cost of reinforcement ) taxes and royalty , all complete as per building specification and direction of E/I.
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063) Floor Joint of 100 mm gap
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 100 mm gap
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063).Roof Joint of 100 mm gap
S/F 35mm thick solid core type non-decorative single leaf flush door and windows with black board core banded with high quality phenol formaldehydes synthetic resin both side commercial veneered of standard make with oxidized iron fittings such as hinges, sliding door bolts tower bolts, handles or rings hooks and eyes, cleats sand block as per schedule taxes and royalty all complete as per building and direction of E/I.(one side teak)
Supplying, fitting & fixing 35mm thick solid core type non-decorative double leaf flush shutter in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
Providing Tor steel reinforcement of 10mm dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
Providing Toe steel reinforcement of 12mm to 32mm dia bars as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel)
Providing and fixing fan hooks of 16mm dia M.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per building specification and direction of E/I.
Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 600X600 mm size
Providing and laying Double Charge vitrified floor tiles in Different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS 15622/ISO 13006, of approved make , in all colour and shades laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointed with grey cement [email protected] kg /sqm including grouting the joints with white cement and matching pigment etc.Size of tiles 600x600mm
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) -with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty as per building direction of E/I.
Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Extra of plaster work over exterior surface for each consecutive floor above above first floor including cost of scaffolding etc. All complete as per direction of E/I. 2ND FLOOR=C
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Ordinary rock
Hard rock (blasting prohibited)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil
Supply and stacking of Fly ash conforming to IRC- 58 at site, including carriage, loading, unloading & stacking up to any lead (measured stacks will be reduced by 20% for payment).
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1. 7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M10 grade with minimum cement content of 220 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementConcrete of M35 grade with minimum cement content of 370 kg /cum
Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.200 mm wide
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonr
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS : 12894, in super structure above plinth upto floor V level.Cement mortar 1: 4 (1 cement: 4 coarse sand)
Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately).Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
Granite stone slab of colour black, Cherry/Ruby red
Area of slab upto 0.50 sqm
Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Marble work
Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete.50 mm long
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
25 mm thick (for cupboard) including ISi marked nickel plated bright finished M.S. piano hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured):Rectangular or square
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Single rubber stopper
Twin rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.
Triple strip vertical type
Double strip (horizontal type)
Providing & Fixing decorative high pressure laminated sheet of plain I wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0mm thick
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
With 2nd class teak wood beading 62X19 mm
With 12 mm mild steel U beading
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in?charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Electric resistance or induction butt welded tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 160 mm
Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement 18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Makrana white second quality
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Agaria White
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand):Light shade pigment using white cement
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand):Medium shade pigment using 50% white cement, 50% ordinary cement
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Medium shade pigment using 50% white cement 50% Grey cement
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre.
15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand)
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In two coats
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with fine sand including finishing the top smooth.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot DipGalvanised with serrations and serrated washers to arrest the wind loadmovement, fasteners, SS 316 Pins and anchor bolts of approved make inSS 316, Nylon separators to prevent bi-metallic contacts all completerequired to perform as per specification and drawing The item includescost of all material & labour component, the cost of all mock ups at site,cost of all samples of the individual components for testing in an approvedlaboratory, field tests on the assembled working curtain wall with aluminiumcomposite panel cladding, cleaning and protection of the curtain wall withaluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics allcomplete , as per the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directed by theEngineer-in-Charge. However, for the purpose of payment, only the actualarea on the external face of the curtain wall with Aluminum CompositePanel Cladding (including width of groove) shall be measuredin sqm. up to two decimal places.
Granite of any colour and shade
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete,80x1.25 mm M.S. laths with 1.25 mm thick top cover including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
Steel work welded in built up section/framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required all complete
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent Engineer-in-Charge :
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 600X600 mm size
Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying Ceramic glazed floor tiles 300 x 300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in all coloures, shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc. complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 MM
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. Clip 110mm
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 275
Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm asper IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sideof the sheet and polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratches duringtransportation and should be supplied in single length upto 12 metre or asdesired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete uptoany pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shapewherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester topRidges plain (500 - 600mm) coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Flashings/ Aprons.( Upto 600 mm)
Gutter (600 mm over all girth)
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : 279
Neat cement punning
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement
12 mm cement plaster
20 mm cement plaster
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand).
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)
Applying priming coat:With ready mixed red oxide zinc chromate primer of 307
Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour .Two Coat
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coat
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :15 mm wide and 15 mm deep groove
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameter
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supplying and stacking at site Good earth
Supplying and stacking at site.
90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Stone screening 13.2 mm nominal size (Type A)
Stone screening 11.2 mm nominal size (Type B)
Red bajri
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber.finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete prepared with batch mixing machine
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408)Using Concrete Batching and Mixing Plant
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorised sign asper IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
Road Delineators (Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings.)
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified)
Metal Beam Crash Barrier:-Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)
Flexible Crash Barrier, Wire Rope Safety Barrier (Providing and erecting a wire rope safety barrier with vertical posts of medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m), 1.50 m long 0.85 m above ground and 0.65 m below ground level, split at the bottom for better grip, embedded in M 15 grade cement concrete 450 x 450 x 450 mm, 1.50 m center to center and with 4 horizontal steel wire rope 40 mm dia and anchored at terminal posts 15 m apart. Terminal post to be embedded in M 15 gradecementconcretefoundation2400 x 450 x 900 mm (depth), strengthened by a strut of RS joist 100 x 75 mm, 2 m long at 450 inclination and a tie 100 x 8 mm, 1.50 m long at the bottom, all embedded in foundation concrete as per approved design and drawing, rate excluding excavation and cement concrete.)
Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately))
Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed)
In rows 15 cm apart in either direction
In rows 7.5 cm apart in either direction
Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm)
Maintenance of Lawns or Turfing of Slopes (Maintenance of lawns or Turfing of slopes (rough grassing) for a period of one year including watering etc)
Turfing Lawns with Fine Grassing including Ploughing, Dressing (Turfing lawns with fine grassing including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying doobs grass roots at 10 cm apart, including supplying and spreading of farm yard manure at rate of0.6 cum per 100 sqm)
Maintenance of Lawns with Fine Grassing for the First Year
a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart)Maintenance of Hedge for one year
Maintenance of Hedge for one year
a) Planting Flowering Plants and Shrubs in Central Verge
Maintenance of Flowering Plants and Shrubs in Central Verge for one Year
Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year)
Renovation Lawns including, Weeding, Forking the Ground, Top Dressing with Forked Soil (Renovation lawns including, weeding, forking the ground, top dressing with forked soil, watering and maintenance the lawns, for 30 days or more, till the grass forms a thick lawn, free from weeds, and fit for moving and disposal of rubbish as directed, including supplying good earth, if needed but excluding the cost of well decayed farm yard manure)
Supply at Site Well Decayed Farm Yard Manure (Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking)
Wrought Iron and Mild Steel Welded Work (Wrought iron and mild steel welded work) (using angles, square bars, tees and channel grills, grating frames, gates and tree guards of any size and design etc. including cost of screens and welding rods or bolts and nuts complete fixed in position but without the cost of excavation and concrete for fixing which will be paid separately)
Tree Guard with MS Angle Iron and Steel Wire (Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3 mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together)
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer Using rough kota stone
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :Using rough Kota stone
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion - Powder coated aluminium (minimum thickness of powdercoating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing offittings wherever required including the cost of EPDM rubber /neoprene gasket required (Fittings shall be paid for separately) - Powder coated aluminium (minimum thickness of powdercoating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windowspre-laminated particle board with decorative lamination on both sides shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer?in-charge.With stainless steel cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in chargPowder coated minimum thickness 50 micron aluminium
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :Dumb bell with central bulb (180 mm wide, 8 mm thick)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. 523
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in Charge
Excavation in Ordinary Rock with Dozer with lead upto 100 metres (Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres ), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.)
Excavation in Hard Rock (requiring blasting) with disposal upto 1000 metres (Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with in all lifts and leads upto 1000 metres )
Excavation in Hard Rock (controlled blasting) with disposal upto 1000 metres (Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, loading and disposal of cut road with in all lifts and leads upto 1000 metres )
Embankment Construction with Fly ash/Pond ash available from coal or lignite burning Thermal Plants as waste material. (Construction of embankment with fly ash conforming to table 1 of IRC: SP: 58 - 2001 obtained from coal or lignite burning thermal power stations as waste material, spread and compacted in layer of 200mm thickness each at OMC, all as specified in IRC: SP: 58-2001 and as per approved plans.)
Carriage of materials
Bricks - 8km (1k + 7p)
Fly Ash Brick - 15km
Sand - 10 km
Chips - 22 km
Local Sand - 3 km
Sanitary Works
Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 liters C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware ware footrest to be fixed than 50 gms, 15mm PVC connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. 510 mm long with 12.50 Litre low level cistern
Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. With 'P' trap - 12.5 lit low level PVC Cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required.510x1040 mm bowl depth 250 mm
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China a Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 40 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bor
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore
Providing and fixing toilet paper holder :C.P. brass
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :
For 100 mm dia pipe
For 75 mm dia pipe
Providing, fixing, testing and commissioning of motorised butterfly valve/ball valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 2 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc. 40 mm dia
Providing, fixing, testing and commissioning of motorised butterfly valve/ball valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 2 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.50 mm dia
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15kg /sqcm with threaded / flanged joints complete with nuts, bolts, gaskets. washers etc. 15 mm dia
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15kg /sqcm with threaded / flanged joints complete with nuts, bolts, gaskets. washers etc. 20 mm dia
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15kg /sqcm with threaded / flanged joints complete with nuts, bolts, gaskets. washers etc. 25 mm dia
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15kg /sqcm with threaded / flanged joints complete with nuts, bolts, gaskets. washers etc. 32 mm dia
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15kg /sqcm with threaded / flanged joints complete with nuts, bolts, gaskets. washers etc. 40 mm dia
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15kg /sqcm with threaded / flanged joints complete with nuts, bolts, gaskets. washers etc. 50 mm dia
Providing & Fixing water purifier cum water cooler made of stainless steel having storage capacity of 80 liter & cooling capacity 60 liter / hour with Reverse osmosis system & ultra voilet membrane TDS reduction 90% having automatic back wash system with filtration unit & all other required accessories complete in all respect as per direction of the engineer in charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore
32 mm nominal bore.
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :100 mm dia
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :100 mm dia nominal bore
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :100 mm dia
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
40 mm nominal bore:-Horizontal
41 mm nominal bore:-Vertical
50 mm nominal bore:- Horizontal
51 mm nominal bore:- Vertical
80 mm nominal bore :-Vertical
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
15 mm diameter pipe
20 mm diameter pipe
25 mm diameter pipe
32 mm diameter pipe
40 mm diameter pipe
50 mm diameter pipe
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality EHD - 35 Circular shape 560 mm internal dia
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :
Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :icks of class designation 7.
Jointing glazed stoneware pipes with stiff mixture of cement mortar in the proportion of (1:1).150 mm diameter
200 mm diameter
250 mm diameter
300 mm diameter
150 mm diameter S.W. pipe
200 mm diameter S.W. pipe
250 mm diameter S.W. pipe
180x150 mm size P type
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
500 mm dia. R.C.C. pipe
600 mm dia. R.C.C. pipe
1:5:10 (1 cement : 5 coarse sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Size 120x90 cm
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD 20 grade designation) 560 mm internal diameter conform ing to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).200 mm dia
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in?charge.All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Providing and fixing PTMT grating of approved quality and colour.
Circular type - 100mm dia
Circular type - 125mm dia
Laying cement concrete (1:5:10) alround S.W. pipes:100 mm diameter S.W. pipe
Electrical Works
Point wiring in PVC conduit, with modular type switch - Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.Group C
Twin Control Point Wiring in PVC Conduit, with Modular type Switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc as required.
Power Plug wiring in PVC Conduit (2X4 Sq.mm) :- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor songle core cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required.
Power plug wiring in PVC conduit (4 x 4 sq.mm.) - Wiring for light/power with 4 x 4 sq.mm. FR PVC insulated copper conductor single core cable in surface recessed PVC conduit, along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
2x1.5 Sqmm + 1x1.5 sqmm earth wire(for Single Separate 5A from nearest switch board and wall fans)
2 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire
2x1.5 Sqmm + 1x1.5 sqmm earth wire(for Single Separate 5A from nearest switch board and wall fans)
4 x 10.0 sq.mm. + 2 x 10.0 sq.mm. earth wire
Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit including dismantling as required.
6 x 1.5 sq.mm.
9 x 1.5 sq.mm.
Telephone Wiring in Existing Conduit:-Supplying and drawing following pair,0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required.2 Pair
TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required.
S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.20mm
S/F PVC Conduit:-Supplying and fixing of following sizes of PVC conduit alongwith the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required for Tele, RJ45 Cat 6 data outlet for computer network.25mm
S/F Modular type switch socket - Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required
5/6 amps, one way switch
5/6 amps, 3 pin socket outlet
Telephone socket outlet
TV antenna socket outlet
S/F Modular type electronic fan regulator:- Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
S/F Modular Boxes, base & cover plate:-Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (78 mm x 78 mm x 45 mm)
S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required
S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
S/F twin twisted cable in conduit - Providing and fixing plain 16/0.20mm (0.50 sq.mm.) twin twisted, flexible, FR PVC insulated copper cable, in polythene sleeve of suitable size on the floor/wall, or side of the table door etc. as required.
ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.
ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required.
ITC exhaust fan upto 450mm sweeo - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.
Fixing louvers shutter for exhuast fan - Extra for fixing the louvers shutters complete with frame for a exhaust fan of all sizes.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)
6 way, Single door (For Solar))
12 way, single door
S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door, Horizontal type
8 way (4 + 24), Double door, Horizontal type
S/F 'C' series SP MCB:-Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Make- Legrand/Schneider/ Siemens.6/32A Single Pole
S/F SP MCB blanking plate - Supplying and fixing single pole blanking plate in existing MCB DB complete etc. as required.
S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
S/F following rating single pole 240 volts isolator in the existing MCB DB complete with connection testing and commissioning etc. a srequired
S/F SPN RCCB - Supplying and fixing following rating, double pole, (Single phase and netural) 240 volts, residual current circuit breaker (RCCB) having a sensitivity current 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps
G.I. earth plate electrode - Earthing with G.I. earth plate 600mm 600mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But without charcoal or coke and salt)
P/F 25mmx 5mm G.I. earth strip in ground - Providing and fixing 25mm x 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
P/F 6 SWG earth wire with conduit/cable - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm
MV Cable Laying upto 25 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required.
MV cable laying upto 35 sq.mm. in pipe - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. in the existing RCC/HUME/STONEWARE/METAL pipe as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :120 sq. mm
11 KV cable laying upto 400 sq.mm. in pipe - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size exceeding 120 sq. mm but not exceeding 400 sq.mm. in the existing RCC/HUME/STONEWARE/METAL pipe as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 300 sq. mm (70mm)
3½ X 240 sq. mm (62mm)
3½ X 185 sq. mm (57mm)
3½ X 150 sq. mm (50mm)
3½ X 120 sq. mm (45mm)
3½ X 95 sq. mm (45mm)
3½ X 70 sq. mm (38mm)
3½ X 35 sq. mm (32mm)
3½ X 25 sq. mm (28mm)
4 X 16 sq. mm (28mm)
4 X 10 sq. mm (25mm)
2 X 16 sq. mm (22mm)
2 X 10 sq. mm (19mm)
2 X 6 sq. mm (19mm)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
150 mm dia
250 mm dia
300 mm dia
G.I. earth plate electrode - Earthing with G.I. earth plate 600mm 600mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (with charcoal or coke and salt)
Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (with charcoal or coke and salt)
P/F 25mmx 5mm G.I. earth strip in ground - Providing and fixing 25mm x 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
P/F 25mmx 5mm copper earth strip in ground - Providing and fixing 25mm x 5mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
P/F 25mm x 5mm copper earth strip in surface/recess - Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required.
P/F 25mm x 5mm G.I. earth strip in surface/recess - Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connections etc. as required.
P/F 6 SWG G.I. loop earthing wire in surface/recess - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
P/F 6 SWG earth wire with conduit/cable - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required.
Providing and fixing earth bush of 50mm x 5mm copper strip on surface for connections etc. as required
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Erection of metallic pole upto 13m in C.C - Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre
Above 6.5 metre and upto 8.0 metre
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.32 mm dia
Supplying and drawing of following Sizes of FR PVC insulated Copper Conductor, Single core Cable in the existing Surface / recessed Steel/ PVC conduit as required.
Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to 15 1239/3589 including Fittings like elbows, tees flanges, tapers nuts, bolts, gaskets etc and fixing the pipe on the wall/ ceiling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.25 mm dia
Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to 15 1239/3589 including Fittings like elbows, tees flanges, tapers nuts, bolts, gaskets etc and fixing the pipe on the wall/ ceiling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.80 mm dia
Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to 15 1239/3589 including Fittings like elbows, tees flanges, tapers nuts, bolts, gaskets etc and fixing the pipe on the wall/ ceiling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia
Providing Laying Testing and Commissioning of C class Heavy duty MS Pipe Conforming to 15 1239/3589 including Fittings like elbows, tees flanges, tapers nuts, bolts, gaskets etc and fixing the pipe on the wall/ ceiling with suitable clamp /support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.150 mm dia
Supplying Fixing Testing and Commissioning of butterfly valve of PE 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts, bolts washers gaskets conforming to 15: 13095 of following stres as required.200 mm dia
Supplying Fixing Testing and Commissioning of butterfly valve of PE 1.6 Rating with Bronze Gunmetal Sheet duly ISI marked complete with nuts, bolts washers gaskets conforming to 15: 13095 of following stres as required.150 mm dia
Supplying Fixing Testing and Commissioning of double flange sluice valve of Rating PN 1.6 with non rising spindle, bronze/gunmetal seat ISI marked complete with nuts boits rubber washers and gaskets conforming to B / 180 of following sizes as required.150 mm dia
Providing Installation Testing and Commissioning of Non Retum valve of following sizes contorming to 15:5312 complete with rubber gasket Gl Bolts, Nuts, washers etc as required. 100 mm dia
Providing Installation Testing and Commissioning of Non Retum valve of following sizes contorming to 15:5312 complete with rubber gasket Gl Bolts, Nuts, washers etc as required. 150 mm dia
Providing Installation Testing and Commissioning of Stainless Steel Y Strainer fabricated out of 1.6 mm thick stainless steel Grade 304, Sheet with 3 mm dia holes with stainless steel flange.150 mm dia
Supplying and Fixing First aid hose reel with MS Construction Spray painted in Past office red conforming to IS: 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile Reinforced Type as per 15: 12585 as per IS: 12585 20 mm nominal internal dia gunmetal globe valve and nozzle Drum and Brackets for fixing the equipments on wall Connections from Riser with 25 mm dia stop gunmetal valve and MS Pipe and socket.36.5 Metre Length
Supplying and Fixing of Fire brigade connection of Cast iron body with gunmetal male intantaneous inlet coupling complete with cap and chain as required for suitable dia ms pipe connection conforming to IS: 904 as required .2.Way 100 mm dia MS Pipe
Supplying and Fixing Air Vessel made of 250 mm dia 8 mm thick ms sheet 1200 mm in height with air release valve on top and flanged connection to times dram arrangement withh 25 mm dia gunmetal wheel valve with required accessories pressure gauge and painting with synthetic enaniel paint of approved shade as required
Providing and Fixing of Pressure Switch in MS Pipe Line including connection etc as
Non Schedule
Providing and Fixing of Wodden Fire rated door as per BS:476 Part-20 & 22 & IS 3614 Part-2 For stablity ,integrity and thermal insulation 03 criteria wodden door .Fire door shall be tested at CBRI,Roorkee for maximum rating of 2hr any deviation in specification other than what is mentioned in the test certificates are not allowed .proper label conforming the type of door and the hourly rating is mandatory.
Providing & Fixing Door Locks for fire rated fittings as per manufactures specifications and direction of the Engineer-In- Charge.
Providing & Fixing "Glass (Wired) Vision Panel Of Size 200mm X 300mm" For following fire rated fittings as per manufactures specifications and direction of the Engineer-In- Charge
Providing & Fixing "Door closure" for following fire rated fittings as per manufactures specifications and direction of the Engineer-In-Charge
Providing & Fixing "SS Door Handles for following fire rated fittings as per manufactures specifications and direction of the Engineer-In-Charge
Providing & Fixing "SS Tower Bolts for following fire rated fittings as per manufactures specifications and direction of the Engineer-In-Charge
Providing & Fixing "Panic bar for S/L door" for following fire rated fittings as per manufactures specifications and direction of the Engineer-In-Charge.
Providing & Fixing "Panic bars for D/L doors for following fire rated fittings as per manufactures specifications and direction of the Engineer-in-Charge
Providing & Fixing "External trim for panic bars for following fire rated fittings as per manufactures specifications and direction of the Engineer-in-Charge
Providing & Fixing 50 mm precast glass reinforced concrete jali as por the architectural design including fixing throughout in cement mortar 1:3 (1 cement 3 coarse sand), including pointing in white cement mortar 12 (1 white cement 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers efc complete as per the direction of Engineer-in-charge
Granite work Gang saw cut (Polished and Machine Cut) of thickness of 18mm for wall linning,skirting,and dado(veneer work) in cement mortar 1:3(1cement :3coarse sand )including Pointing with White cement mortar 1:2(1 White cement :2marble Dust)With an admixture of pigment to match the maple shade (to be secured to the backing by means of cramos Which shall be paid seperately)
Diluting and Injecting Chemical Emulsion for pre Constructional anti-termite Treatment and creating a continous Chemical barrier Under all round the column Pits ,Wall trenches ,Basement Excavation,Top Surface Plinth Filling.Junction of Wall and floor ,along the external perimeter of the building ,expansion joints over the top surface of consolidated earth on which apron is to be laid.Sorrounding of pipes and condults etc.complete as per Specification .(Plinth area of the building at ground floor only shall be measured in sqm for Payment).with chlorpyriphos/lindane E.C. 20% with 1% concentration.
Providing and fixing up to floor Five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3(1 cement :3coarse sand ).cost of required centering ,shuttering compelete.1:3:6 (1cement :3coarse sand:6 graded stone aggregate 20mm nominal Size)
Providing & laying Light Weight Foam Concrete of density 500kg/cum. In sunken portion at all level as per direction of Engineer -in -charge.
Providing & Fixing mirror of Superior glass 6mm thick (of approved Quality)and of required shape and size With Wooden moulded frame of approved make and design with 6mm hard board of backing
Granite work Gang saw cut (Polished and Machine Cut) of thickness of 18mm for wall linning,skirting,and dado(veneer work) in cement mortar 1:3(1cement :3coarse sand )including Pointing with White cement mortar 1:2(1 White cement :2marble Dust)With an admixture of pigment to match the maple shade (to be secured to the backing by means of cramos Which shall be paid seperately)
Providing and Laying Ceramic rectified tiles in different Sizes(thickness to be Specified by the manufacturer),with water absorption less than 0.08% and conforming to IS; 15622,of approved brand & manufracturer ,in all colours and shade ,in skirting ,riser of steps ,laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477(Type-2 adhesive ),in average 6mm Thickness ,including grouting of joints (payment for grouting of joints to be made seperately).
Providing and Fixing Clay tiles Work for Wall linning with Special Adhesive like Araldite or equivalent over 10mm thick bed of cement mortar 1:3(1Cement :3 coarse sand) including Pointing in White Cement With an Admixture of pigment to match the stone shade.
Supplying,Storing.Handling,Shifting,Installation,Testing and commissioning of cp Flexible hose ,spray ,Wall Flange ,etc.complete
Providing and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and fixing CP brass single lever low flow wall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete including cutting and making good the walls where required.
Providing & Fixing of Grab Bar size 600mm long in handicap toilet complete as required.
Providing Fixing satin finish stainless steel AISI 316 grade wall mounted coat hook on door complete.
Fixing of Storage type water heater/ Geyser with required accessories like 15 mm CP angle valve on inlet, heavy duty reinforced flexible PVC connector for cold water line and flexible CP brass connector with CP checkout for hot water line, CPVC line connection, MS bracket with two coats of enamel paint, anchor fastners etc to hang the units, providing and fixing of 16 A 3 Pin plug of Anchor make, etc complete as required. Capacity 25 liters
Providing and fixing sound insulated Polyproplene piping system as per ON EN 1451-Part 1-6 & EN 12056 Part 1-5 with 3 layer pipe made of PP-C + PP-MV PP-C in Blue Ral 5014 (halogen and calcium free) colour, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA as per DIN 4109 at a flow rate of 4 1/s and having pipe nng stiffness as per 1S0/DIS 9969 and lightness as per EN 1277/B and C and DIN 19560. density of pipe = 1.25gms/cm3, elonoation= 0.05mm / m * OK and tensile strength > 24 N/mm2 with all necessary fittings in blue colour, fitted with factory fitted lip ring incluiding painting with ordinary cement based paint for external installation. (POLOPLAST PKNG/REHAU) 110 mm OD
Providing and fixing sound insulated Polyproplene piping system as per ON EN 1451-Part 1-6 & EN 12056 Part 1-5 with 3 layer pipe made of PP-C + PP-MV PP-C in Blue Ral 5014 (halogen and calcium free) colour, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA as per DIN 4109 at a flow rate of 4 1/s and having pipe nng stiffness as per 1S0/DIS 9969 and lightness as per EN 1277/B and C and DIN 19560. density of pipe = 1.25gms/cm3, elonoation= 0.05mm / m * OK and tensile strength > 24 N/mm2 with all necessary fittings in blue colour, fitted with factory fitted lip ring incluiding painting with ordinary cement based paint for external installation. (POLOPLAST PKNG/REHAU) 75 mm OD
Providing and fixing PP white Trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connections 110 mm inlet & 110 mm outlet.Providing and fixing floor drain (FD) with 50mm outlet and 100/110 mm inlet
Providing and fixing floor drain (FD) with 50mm outlet and 100/110 mm inlet.
roviding and fixing clean out pipe (door piece) of POLO KAL NG or equivalent for cleaning.with 100 mm dia. Pipe
Providing and fixing F.R.P. Grating drain cover M.S. Angle ( 35 * 35 * 5mm ) . (Load Bearing cap. 2.5 T, suitable for car parking, basement, Pump room. Parking Area ) THERMO DRAIN or Equivalent.
Providing and fixing sound insulated Polyproplene piping system with 3 layer pipe, push-fit type, food safe, having high impact and stiffness, offering sound levels of not more than 22 dBA with all necessary fittings, fitted with factory fitted lip ring. (POLOPLAST-PKNG), RAUPIANO PLUS or equivalent).
Providing and fixing Gl pipes complete (IS: 1239 medium class) with GI fittings conforming to IS: 1879 and clamps including MS pipe supports, painting with two or more coats of synthetic enamel paint including one coat of primer as per specification cutting and making good the walls etc, complete. 65 mm dia, nominal bore
Providing and fixing Gl pipes complete (IS: 1239 medium class) with GI fittings conforming to IS: 1879 and clamps including MS pipe supports, painting with two or more coats of synthetic enamel paint including one coat of primer as per specification cutting and making good the walls etc, complete. 80 mm dia, nominal bore
Providing and fixing Gl pipes complete (IS: 1239 medium class) with GI fittings conforming to IS: 1879 and clamps including MS pipe supports, painting with two or more coats of synthetic enamel paint including one coat of primer as per specification cutting and making good the walls etc, complete. 100 mm dia. nominal bore
Providing and fixing C.I. butterfly valves PN-1.6 complete with bolts, nuts, 1.5 mm thick compressed asbestos gasket and flanges as per Table "E" complete. 65 mm dia
Providing and fixing C.I. butterfly valves PN-1.6 complete with bolts, nuts, 1.5 mm thick compressed asbestos gasket and flanges as per Table "E" complete. 80 mm dia
Providing and fixing C.I. butterfly valves PN-1.6 complete with bolts, nuts, 1.5 mm thick compressed asbestos gasket and flanges as per Table "E" complete. 100 mm dia
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover.
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover.10 pair Tag block
Supply, installation, testing and commissioning of following krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover.30 pair Tag block
Supply, installation, testing & commissioning of Bulk Head Luminare delivering an initial system lumen of 700 lumens & the luminaire shall be with system efficacy ≥ 70 lm/W. Housing: Die Cast Aluminium. IP65, Diffuser OPAL Polycarbonate. The operating CCT shall be 5700K with CRI of 270. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270VTHD <= 20% & PF >= 0.95 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (cat no. LW07-141-XXX-57-XX)
Supply, installation, testing & commissioning of 65 W Recessed Mounted LED luminaire delivering an initial system lumen of 6500 lumens & the luminaire shall be with system efficacy >= 90lm / W The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V THD <= 20% & PF >= 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply, installation, testing & commissioning of 15W Surface mounted Round Led Downlighter delivering an initial system lumen of 1527 lumens & the luminaire shall be with system efficacy >= 84 Im / W. Housing: Die Cast Aluminium. IP20, Optics: PMMA LGP/Polysterene Diffuser. The operating CCT shall be 6000K with CRI of 280. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V, THD S 20% & PF >= 0.95 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (cat no. LD80-171-XXX-60-SM)
Supply, installation, testing & commissioning of 4ft Linear LED luminaire delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of 280. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V, THD <= 20% & PF 2 0.95, 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard(cat. no.LL20-221-XXX-65-NE3)
Supply, installation, testing & commissioning of 10W Wall mounted LED luminaire delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The luminaire Housing shall be made of extruded Aluminium & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of 280. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V THD <= 20% & PF >= 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.
Supply of decorative wall mounted light fixture with lampbase E27. Housing made of metal synthetic. (cat no.LM91-L180-CRWH)
Supply, installation, testing & commissioning of 36W Surface/ Suspended 500mm Round Led Fixture delivering an initial system lumen of 3230 lumens & the luminaire shall be with system efficacy >= 95 lm/W. Housing: CRCA. IP20, Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of 280. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V, THD <= 10% * 8 PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (cat no. LM71-441-XXX-57-XX)
Supply, Installation, testing and commissioning of SW LED mirror light shall be 6500K. Housing shall be synthetic chrome/Engineering plastic with IP20 protection having lumen output of min 900 lumes having minimum system efficacy of 90lm/w & THD<25%..complying to above specifications.. Wipro Make LL20-111-XXX-65NE3 or equivalent as specified in the approved list of make.)
Supply, Installation, Testing and Commissioning of 150W chandlier LED lightPhilips Lighting Cat no- or equivalent as specified in the approved list of make.)
Supply, installation, testing & commissioning of 12W Surface mounted Round Led Downlighter delivering an initial system lumen of 1527 lumens & the luminaire shall be with system efficacy ≥ 84 Im / W. Housing: Die Cast Aluminium. IP20, Optics: PMMA LGP/Polysterene Diffuser. The operating CCT shall be 6000K with CRI of 280. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V, THD S 20% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. (cat no.LD80-171-XXX-60-SM)
Supplying of following items Power Saver A.C. electric Ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 Volts, 50 Hz, single phase, A.C. supply etc. as reqd. i. 1200mm fan
Supplying of 300 mm dia Exhaust fan (Ventilating Fans), complete with louvers mounting rings frame as reqd.
IPDOME (Indoor): 2Megapixel@25fps, H.265Compression, 1/3"Lowlllumination CMOSSensor, IPVANDALDOMECamerawith2megapixelHD2.8-12mmVarifocal Lensupto25meters, withAudioln/Out. SupportsiOS&AndroidApps. SupportsSDCard SupportsONVIF.IP66 Protection Rating. Supports POE
IPBullet Camera, 2Megapixel@25fps, H.265Compression, 1/3"LowIlluminationC MOSSensor, IPBullet Camerawith2megapixelHD2.8-12MMVarifocalLensupto35meterswithAudioIn/Out, SupportsiOS & AndroidApps SupportsONVIF.Supports SD Card, IP66 Protection Rating. Supports POE.
Network Video Recorder-H.264/MPEG4decoding.-4ChannellPcamerasinputs, 1Audioln &1AudioOut, 1 Videoout@VGA(1080P), 1HDMlout(1080P)withRecording Modein Manual, Schedule & Alarm, Recording&Playback Upto25fps@PALperCH,8xSATAHDD(1ESATAoutof8) port, 8alarminput&1output, NetworkethernetInterfacesupportsRJ45gigaethernet, Multi- useronlinesimultaneous,, backupbyUSB, Withremotecontrol. PS2interfaceformo use. SupportsDDNS, PTZControl, RS-485, DigitalZoom, Motion Detection, VideoLoss, Alarmrecording, Buzzer, EachCh annelBackup, Password Control, Firmware Update and Mobile applications
Special Surveillance4TB3.5" SATAHDDinternal(ForNVR's)etc all complete
55"FullHDLEDdisplay, HDMI, VGA, 20Winbuiltspeaker, IPS LED display, with wall mount bracket
24UITEquipmentrack, withventilation, slidingshelves, power strips,
Wallmounted6UITEquipmentrack, withventilation, slidingshelves, power strips,
8PortsIndustrialgradeswitch, POE+, 2GigabitSFPSlots, 8KMACaddresstable, Ri ngrecovertime<20ms, SupportSTP, RSTP, MST, 802.1QVLAN, Supporttelnet, S SH,MAC- BasedVLAN, IPSubnetbasedVLAN, Devicemanagement: topology View, FLoorVi ew MapView, Dashboard, trafficmonitoring, Cablediagnostics, UL, CE, FCCCertifi ed, IP40protection, Operatingtemperature-40°Cto75°C, Storage Temperature- 40°C to 85°C, Humidity 5 to 95% RH
Cat6ArmouredCableforPOEpurpose. 10- GigabitEthernetspeedwithfrequencyupto500MHz.Maxcablelengthof90meters (as per actual)
6 Core Armoured OFC Cable as per actual)
RJ-45 outlets near the cameras
8portloadedfiberLlUboxwithpigtailsandcouplerswithallrequired accessories
Accessoriesforcameratermination. Thisalsoincludes Camera Distributor/Junctio In Box/Interfaces
TWO POLE STRUCTURE Supplying, installing, structural steel tubular pole conforming to IS-2713, 410 SP-51, 164 Kg weight with base plate of 300 mm x 300 mm x 6 mm for erecting 11 KV two pole structure comprising of 11 Mtr pole, Vo welding, cutting, revetting, bolting and painting the entire structures with red oxide primer and two coats of synthetic enamel paint and necessary foundations including excavation and earth work for the steel structure with PCC 1:2:4 with following accessories i- Supplying, installing 11 KV 9 KA discharge current single pole lightning arrestor with insulated base and necessary hardware. 3 Nos. ii- Supplying & installing 11 KV single pole strain insulators complete with all necessary hardware for termination. - 3 Nos. iii- Supplying & installing 11 KV 3 phase, 200 Amp. Vertical type gang operated switch with hot dip galvanised channels post type, insulator, tinned copper contacts, arcing horns. Gl pipe gang operating handle, limit switch etc. (wiring with 4 * 2.5 sq.mm PVC insulated copper wire upto HT breaker laid in GI pipe of 40mm dia) locking arrangements etc. complete in all respects-1Set. iv- Supplying & installing 11 KV post type insulators for jumper supports - 3 Nos. v- 11 KV. 3 phase 200 Amp dropout fuse unit with 60 Amp fuses, Hot dip galvanished channel, post type insulator, tinned copper contacts bakelite fuse, carriers etc. complete in all respects.- 1 Set vi- Supplying & installing of "DOG" 6/186 Al. Plus 7/0.062 Steel ACSR overhead conductor - 10 Mirs. vii- Cross arms of shape and size as shown on drawing and made out of M.S. channels 100mmx50mm with flats and fixed to poles with M.S. clamps, Gl bolts, nuts and washers and all hardware, jumpers & thimbles etc. of required size. viii- Anti Climbing devices on each pole made out of 2 mm barbed wire coiled alongwith pole. Danger Notice Boards with Skull & Bones in red colour made out of 14 SWG sheet in Hindi & English with voltage indicated. x- Supplying & installing 150 mm dia Gl pipe - 10 Mtr. xi- Earthing & Gi Strips. xii- Stay Assembly.
OIL TYPE OUTDOOR TRANSFORMER Supplying, installing, testing & commissioning of Oil Type Outdoor Transformer with copper winding having a continuous rating of following capacity, 11 KV/433 V, 3 Phase, 50 Hz, having bushing on HV side suitable for 11 KV XLPE cable & on 433 Volt L.V. side suitable for 3 Nos 3.5C * 300 Sq mm XLPE Cable. The Transformer shall have On load tap changing links on HV side, for +5.0% to -15.0% in steps of 1.25% It shall also have Earthing Terminal, Lifting hooks, base channels skid type suitable for mounting on floor and plinth. i- 630 KVA
Supplying, installing, testing & commissioning of Trickle Boost Charger of 24 Volt complete with automatic trickle charger, change over complete with voltmeter, ammeter 50 Hz. AC supply & DC ammeter/voltmeter complete with 12 Nos. 2 Volt batteries, 40 AH etc. as required.
Supplying, installation, testing and commissioning of double door, lockable, factory fabricated, distribution feeder panel suitable for out door installation made out of 2mm thik CRCA sheet, IP 55 inclosure, duly enamel painted and 450mm high from ground level, black painted M.S. angle iron stand complete with following switchgears, connection, inter connection etc. as per details below including suitable size 4 strip Al. bus bar etc. Plumbing Panel (Pump Room) INCOMER 1 No. 160A 4P MCCB,25 kA breaking capacity with thermal release and adjustable setting and with rotary handle with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB METERING & INDICATION 1 set of RY,B phase indicating lamps arter with 10A T1 set of ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB BUS-BAR 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 3 Nos. 12 HP Star Delta Starter with 63A TP MCB (Borewell Pumps-1.2.1 2 Nos. 3 HP DOL Starter with 16A TP MCB (Filter Feed Pump- 1w + 18 ) 2 Nos. 3 HP DOL Starter with 20A TP MCB (STP Make Up Pump- 1w + 18 ) 2. Nos. 6 HP Star Delta Starter with 20A TP MCB (Domestic Water Supply Pump- 1w + 18 ) 2 Nos. 3 HP Star Delta Starter with 16A TP MCB (Domestic Water Supply Pump- 1w + 18 ) 2 Nos. 2HP DOL Starter with 10A TP MCB (Drainage Sump Pump-1W+15) 1 Nos 0.5HP DOL Starter with 16A SPN MCB (Chemical Doser-1W) 2 No. 20A TPN MCB 1 No. 16A TPN MCB 2 Nos. 10A TPN MCB 1 No. 16A SPN MCB NOTE: All starters shall have ON & OFF push button & suitable rating of contractor and overload relays Supplying, Receiving, fixing, testing & commissioning of above described Panel
STP Panel INCOMER 1 No. 100A 4P MCCB, 25 kA breaking capacity with thermal release and adjustable setting and with rotary handle, with ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB METERING & INDICATION 1 set of R,Y,B phase indicating lamps 1 set of ON/OFF/TRIP indication Lamps, MFM with Communication Facility along with control SP MCB BUS-BAR 1 Set of 125A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS 2 Nos. 2 HP DOL Starter with 10A TP MCB (Raw Sewage Relift Pumps- 1W + 1S ) 2 Nos. 2 HP DOL Starter with 10A TP MCB (Sludge Recirculation Pumps 1W + 1S ) 2 Nos. 2 HP DOL Starter with 10A TP MCB (Plant Room Sump Pumps- 1W + 1S 2 Nos. 2 HP DOL Starter with 10A TP MCB (Sludge Loading Pumps- 1W + 1S 2 Nos. 6 HP DOL Starter with 10A TP MCB (Air Blowers-1W+1S) 2 No. 2 HP DOL StP MCB (Centrifugal Pump- | w + 1S ) 2 Nos. 3 HP DOL Starter with 16A TP MCB (Filter Feed Pumps- 1W + 1S ) 2 Nos. 2 HP DOL Starter with 16A TP MCB (Softner Feed Pumps 1W + 1S ) 2 Nos. 2 HP DOL Starter with 16A TP MCB (Soft water transfer Pumps-1W+1S) 2 Nos. 4 HP Star Delta Starter with 40A TP MCB (Flushing Water Transfer Pump- W + 1S ) 1W + 1S ) 2 Nos. 3 HP DOL Starter with 20A TP MCB (Irrigation Water Pumps- 2 No. 0.5 HP DOL Starter with 16A DP MCB (Chemical Dozer-1W) 2 No. 3 HP DOL Starter with 10A TP MCB (UV System) 1 No. 40A TPN MCB 1 No. 16A TPN MCB 4 Nos. 10A TPN MCB 1 No. 16A SPN MCB NOTE: All starters shall have ON & OFF push button & suitable rating of contractor and overload relays Supplying, Receiving, fixing, testing & commissioning of above described Panel
SUBHEAD-II-D.G. SETS Design, manufacture, supply, erection, testing & commissioning of following rating of DG Sets in Accoustic Enclosure, having self excited & self regulated 415 V, 3 Phase, 4-Wire, 50 Hz, 0.8 p.f. Alternator coupled with multi-cylinder, turbo-charged/ turbo-charged after cooled as called for, Diesel Engine capable to generate the power not less than the required BHP to achieve the alternator capacity as given below, with radiator Cooled, Residential type silencers and Electronic governer (G3 Governing System), DG set controller suitable for Auto Synchronization & Auto Load Sharing with microprocessor based Synchronization relay like Woodward/Dief/ Deepsea or equivalent including providing of Engine control panel, 24V batteries of suitable rating, battery-charger with battery leads, inbuilt oil fuel tank of capacity as per OEM standards and complete with all standard accessories & protection as required and as per specifications, including first filling of lube oil, fuel tank, providing common base plate, anti vibration pads, drip trays, foundation bolts, nuts, bolts, cable termination/adopter box sutiable to terminate upto NO. of run 3.5Cx300 sq.mm, XLPE cables as required for a
380 KVA (With Acoustic Enclosure)
320 KVA (With Acoustic Enclosure)
Supply, installation, testing and commissioning of exhaust pipe fabricated out of 6 mm thick MS pipe Class C Heavy duty conforming to IS:3589 with all fixing accessories and hardwares. The work include necessary cladding of exhaust pipe work using 50 mm thick Loosely bound resin (LBR) mattress/ mineral wool/ Rockwool, density not less than 120kg / m * 3 and aluminium cladding (0.6 mm thick) for the complete portion. The exhaust pipe work includes necessary supports, foundation etc. to avoid any load & stress on turbo charger/exhaust piping. The exhaust pipe shall be run along the existing wall of the building duly clamped/supported on independent structure for which, the design and Drawing for such structure shall be got approved from the Engineer-in-charge.125 mm dia
Design, supply, fabrication and erection of steel structure from channel /angle iron of suitable sizes to support the chimney /exhaust MS pipe duly taking into consideration of the wind load/pressure at the site etc. including the cost of civil foundations as required to support a maximum of 2 nos exhaust chimneys on the overhead platform complete as required. The structure shall be given primer coat and two coats of enamel painting.
SS Flexible Bellow 125 mm dia
Aluminium cladding for the residential silencers
Supply & Fixing of Y Bend for Exhaust pipe
SUBHEAD-III-SUPPLYING AND LAYING OF CABLES H.T. CABLE Supply of following size of 11 KV (UE) XLPE cable circular aluminium conductor, conducto screened, XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape. Aluminium round wire armoured and overall PVC sheathe earthed cable conforming to 1S / 7098 / 11 / 85 with latest amendments.3 Core 300 Sq.mm.
Supply and laying following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty. Armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (Conforms to 1S / 1554 ,part-1)
3.5 x 300sq .mm.
3.5 x 240sq .mm.
3.5 X 185sq .mm.
3.5 x 150 sq.mm.
3.5 X120sq .mm
3.5 X 95sq .mm.
3.5 X 70sq .mm.
3.5 X 35sq .mm
3.5 X 25sq .mm
4 X 16sq .mm
4 X 10sq .mm
4 X 6sq .mm.
2 X 16sq .mm.
2 X 10sq .mm.
2 X 6sq .mm.
Supplying, fixing, testing and commissioning of following bare Copper/ Gl flat including all necessary fixing accessories and effecting connections.
50mm X 6 mm thick Cu flat
50mm X 6n thick GI flat
Supply & erection of the following equipment at suitable place in the sub-station building as required and as per detailed specifications.
First aid box as approved by St. John Ambulance Brigade/ Indian Red Cross conforming to IS:5424-1969.
Shock treatment chart at least in three languages as required.
Insulating mat 2.5 mm thick to withstand 11 KV dielectric strength as per 1S / 15652 - 2006
Insulating mat 2 mm thick to withstand 3.3 KV dielectric strength as per IS: 15652-2006
Supplying Rubber hand gloves suitable for 11 KV.
Supply, installation, testing & commissioning of IP Bullet Camera, 2 Megapixel @ 25fps, H.265 Compression, 1/3" Low Illumination CMOS Sensor, IP Bullet Camera with 2 megapixel HD 2.8- 12MM Varifocal Lens upto 35 meters with Audio In/Out, Supports IOS & Android Apps. Supports ONVIF. Supports SD Card. IP66 Protection Rating. Supports POE
Supply, installation, testing & commissioning of 6MP Fish Eye Panoramic Dome Camera, H.265 Compression, 1/2.8" Progressive CMOS sensor, 1.07mm Lens with 360 deg Wide Angle View Supports IOS & Android Apps. Supports ONVIF. IP67 Protection Rating. Supports POE
Supply, installation, testing & commissioning of Network Video Recorder- H.264/MPEG4 decoding.- 32 Channel IP cameras inputs, 1 Audio In & 1 Audio Out, 1 Video out @ VGA(1080P), 1 HDMI out (1080P) with Recording Mode in Manual, Schedule & Alarm, Recording & Playback Up to 25fps@ PAL per CH, 8x SATA HDD (1 ESATA out of 8) port, 8 alarm input & 1 output, Network ethernet Interface supports RJ45 giga ethernet, Multi user online simultaneous, backup by USB, With remote control. PS2 interface for mouse Supports DDNS, PTZ Control, RS-485, Digital Zoom, Motion Detection, Video Loss, Alarm recording, Buzzer, Each Channel Backup, Password Control, Firmware Update and Mobile applications etc all complete
Supply, Installation, testing & Commissioning Special Surveillance 4TB 3.5" SATA HDD internal( For NVR's) etc all complete
Supply, Installation, testing & Commissioning of 55" Full HD LED display, HDMI, VGA, 20W in built speaker, IPS LED display, with wall mount bracket etc all complete
Supply, Installation, testing & Commissioning of 24 U IT Equipment rack, with ventilation, sliding shelves, power strips, etc. all complete
Supply, Installation, testing & Commissioning of Wall mounted 6U IT Equipment rack, with ventilation, sliding shelves, power strips, etc. all complete
Supply, Installation, testing & Commissioning of 24 port switch 24X 10/100/1000 Base X ports, 4 X RJ45 10/100/1000 base T copper ports (Combo), Support Static routing, Should support inter VALN routing, 4 K mac tables, 4K VLANs STP, RSTP, MSTP, PVSTP, dual redundant PSU support switch should be rack mountable, Operating temperature -5°C to 40°C, Relative hummidity upto 85 % etc. all complete etc. all complete
Supply, Installation, testing & Commissioning of 8 Ports Industrial grade switch, POE+, 2 Gigabit SFP Slots, 8K MAC address table, Ring recover ne < 20r , Support STP, RSTP, MST, 802.1Q VLAN, Support telnet, SSH, MAC-Based VLAN, IP Subnet based VLAN, Device management topology View, FLoor View Map View Dash board, traffic monitoring Cable diagnostics. UL.CE,FCC Certified, IP 40 protection, Operating temperature -40°C to 75°C. Storage Temperature -40°C to 85°C, Humidity 5 to 95% RH, etc. all complete.
Supply, Installation, testing & Commissioning of 6 Core Armoured OFC Cable as per actual) etc. all complete
Supply, Installation, testing & Commissioning of RJ-45 outlets near the cameras etc. all complete
Supply, Installation, testing & Commissioning of 8 port loaded fiber LIU box with pigtails and couplers with all required accessories etc all complete
Supply, Installation, testing & Commissioning of Accessories for camera termination. This also includes Camera Distributor/Junction Box/Interfaces etc. all complete
Supply, Installation, Testing & Commissioning of 7 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x16 mm base plate, fixing arrangement of light complete with 4 Nos 24mm dia x 700 mm long foundation bolts, RCC foundation etc as complete as required.
Supply, Installation, Testing & Commissioning of 4 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x12 mm base plate and 750 mm long single arm bracket complete with 4 Nos 20mm dia x 450 mm long foundation bolts, RCC foundation etc as complete as required.
Supplying, installing, testing & commissioning of following accessories in the existing inbuilt control box complete with connection interconnection as required. i) 4 strip Al. bus bar of suitable length. ii) 10A SP MCB
Supply, Installation, Testing & Commissioning of LED light fixture 120 watt, 12000 lumen, integral driver, protection IP 66, CLASS I as complete as required. (Make Philips, Cat No- BVP120 LED 70 CW NB FG S1 PSU GR or equivalent)
Supply, Installation, Testing & Commissioning of LED street light fixture 20 watt, clour cool white integral driver, protection IP 65 as complete as required. (Make Philips, BRP022 LED 20 CW MR S1 PSU GR or equivalent).
Supply. Receiving, Unloading, Shifting, Installation, Testing & commissioning of gate light 1 x 70 watt SON of Philips Make SPC 101 or equivalent.
Supply of garden light bollard fitting made out aluminum die cast bottom pole & top aluminum pressure die cast fitting duly primer & painted with PU paint. As approved color with 10 W power LED complete etc as required. (Hi-Lite Cat - HL-143)
Supplying and erection of 65 mm dia. 0.50 Mtr. G.I. Pipe (medium class) complete with base plate of appropriate size having grouting/ fixing arrangemant in cement concrete on post for providing gate light as per site requirement, painting etc. as required.
Supply and laying following sizes and core PVC/XLPE insulated PVC sheathed, heavy duty. Armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (Conforms to IS:1554, part-1)
4 x 16 sq.mm.
4 x 6 sq.mm.
Supply, installation, testing and commissiong of Solar street light with IP 65 LED fixture having a system wattage of 43W of Philips BRP 403 make with 3500 lumen system output, 2X100Wp high efficiency crystalline solar panel certified IEC 61215 and 2x100Ah tubular lead-acid battery with BIS approval. The LED driver should have 92% efficiency. The battery shall not be discharged beyond 75% of capacity. The solar charge controller should be of Microprocessor Based MPPT make with 96% efficiency and enclosed in IP 65 box. The charge controller shall provide all safety protections and temperature compensated charging of the batter. The battery should be housed in a box made from galvanized steel and powder coated so that it withstands corrosion. The solar system should be mounted on a 7.0 Mtrs Octagonal Pole above ground. The solar street light shall comply with standards such as IEC 61215, IEC 61730, IEC 62124, IEC 61347-2-13, IEC 62384, CISPR 15, IEC 61547, IEC 60598. Type test certificate with compliance to EN 50530 should be provided. The solar panel and battery shall be of reputed make and manufactured in India. The approved makes of LEDs are CREE, Nichia and Philips Lumileds and LM80, LM 79 report to be submitted. The Panel sizing and battery sizing need to be provided using insolation of 5kwh/sqm/day efficiency factor from provided test certificate, dust factor of 0.75. panel ageing of 10%, battery efficiency of 90%. The calculation should be for backup for 36 hours such as Philips BRP 403 43W solar
Supply, forwadig to site, unloading, forwarding, shifting from stores to site, storing, inspection, handling. assembling, installation in correct assigned position, making proper connections, testing and commissioning of 20 Meter High Mast (pole in 2 section) Lighting system (as per CP3-TRT/1996 of ILE, UK) consisting of totally hot dip galvanised by single dip method high mast, lantern, carriage suitable for upto 12 nos. Luminiares, mast head assembly, 2 nos. Aviation obstruction Neon lights, double drum type self sustaining winch, integral power tool (winch motor with control circuit), hot dip galvanised heavy duty pipe Lightning Finial, suitable ropes and Cement concrete foundation of M-15 grade complete as required. The mast is constructed from M.S. plate (as per BS-EN 10025) cut & folded to form a polygonal section, telescopic jointed and welding as per BS-5135. The complete work shall be supervised and certified by the manufactures for satisfactory supply, erection, testing & commissioning of high mast.
Supplying, installation, testing and commissioning of Flood light fitting suitable for 200 watt IP 66 LED having system lumen output of minimum 25000 lumens complete with all accessories and lamp.
Supply, Installation Testing & Commissioning of grid interactive roof top solar photo voltaic power generation system i/c frame but without battery.
Providing and fixing dial type pressure gauge with isolation cock and copper pipe on main header Dial diameter 100 mm celebration 0-16/sq. cm
Providing and fuing Fire Extinguishers (CO2 type powder) 45 Kg Capacity complete with all accessories as per manufacturers specifications
Providing and fixing Fire Extinguishers (A, B, C type powder 16 Kg Capacity complete with all accessories as per manufacturers specifications.
Providing and faing Fire Extinguishers (A, B, C type powder 19 Kg Capacity complete with all accessories as per manufacturers specifications.
Supplying and Fixing Air Vessel made of 450 mm dia 8 mm thick rms sheet 2000 mm in height with air release valve on top and flanged connection to riser drain arrangement with 25 mm dis gunmetal wheel valve with required accessories pressure gauge and painting with synthetic enamel paint of approved shade as required
Providing & fixing double flanged flexicon rubber expansion joint with unit contro of standard length as per maufacturers specs. Tested to a pressure of 20Kg /Sqcn including rubber gaskets, flanges, nuts, bolts and washers complete as required.100 mm dia
Providing & fixing double flanged flexicon rubber expansion joint with unit contro of standard length as per maufacturers specs. Tested to a pressure of 20Kg /Sqcn including rubber gaskets, flanges, nuts, bolts and washers complete as required.150 mm dia
Add 18 % GST
Add 1% Labour Cess
M/s Raj Construction
Excel Venture Construction (P) Ltd.
HEIGHTEN CONSTRUCTIONS
NIRANJAN RAI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid