Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAccepted-Finance MADHAVI NAGAR GADAI PURA A B ROAD GWALIOR DIST GWALIOR M P | GWALIOR | MADHYA PRADESH | 474001 | ₹8.5 Cr | L1 | Accepted-Finance Financially qualify |
| 2 | L2₹8.5 Cr+₹2.0 L (0.24%)Rejected-Finance AMRAVATI COLONY MALLI BAMORI HALDWANI | NAINITAL | UTTARAKHAND | 244713 | ₹8.5 Cr+₹2.0 L (0.24%) | L2 | Rejected-Finance Financially disqualify |
| 3 | L3₹8.5 Cr+₹2.5 L (0.30%)Rejected-Finance | ₹8.5 Cr+₹2.5 L (0.30%) | L3 | Rejected-Finance Financially disqualify |
| Sl No | Description | Qty | Unit | Ratan Construction L2 | VRINDA CONSTRUCTIONS L3 | Mudgal Construction Company L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). | 56.94 | cu.m | 9,854 ₹5,61,086.76 | 9,862 ₹5,61,542.28 | 9,825 ₹5,59,435.5 Lowest |
| 2.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes | 1,177.5 | Kg | 189 ₹2,22,547.5 Lowest | 189 ₹2,22,547.5 Lowest | 189 ₹2,22,547.5 Lowest |
| 3.00 | Earth work in excavation in trenches for foundation and for pipes cables etc. in ordinary soil including fitup to 1.5m and dressing of sides and ramming bottoms and disposal of surplus excavated earth as directed by the engineer with in a lead of 50m. | 2,213.69 | cu.m | 254 ₹5,62,277.26 | 254 ₹5,62,277.26 | 253 ₹5,60,063.57 Lowest |
| 4.00 | Filing available excavated earth in trenches ,plinth,sides of foundation tec.in layers not exceeding 20cm in the depth ,consolidation each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. | 557.92 | cu.m | 191 ₹1,06,562.72 | 191 ₹1,06,562.72 | 190 ₹1,06,004.8 Lowest |
| 5.00 | Providing and laying in cement concrte 1:4:8(1cement :4fine sand:08graded brick aggregated 40mm .nominal size.) and curing complete excluding cost of form work in foundation and floors. | 190.85 | cu.m | 6,635 ₹12,66,289.75 | 6,640 ₹12,67,244 | 6,615 ₹12,62,472.75 Lowest |
| 6.00 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level | 313.84 | cu.m | 9,257 ₹29,05,216.88 | 9,265 ₹29,07,727.6 | 9,230 ₹28,96,743.2 Lowest |
| 7.00 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level | 432.13 | cu.m | 9,604 ₹41,50,176.52 | 9,611 ₹41,53,201.43 | 9,575 ₹41,37,644.75 Lowest |
| 8.00 | Centering shuttering including strutting, propping etc. and removal of form work Foundations, footings, bases of columns, etc. for mass
concrete | 1,534.39 | sqm | 382 ₹5,86,136.98 | 382 ₹5,86,136.98 | 381 ₹5,84,602.59 Lowest |
| 9.00 | Centering shuttering including strutting, propping etc. and removal of form work Columns, Pillars, Piers, Abutments, Posts and Struts. | 719.76 | sqm | 936 ₹6,73,695.36 | 937 ₹6,74,415.12 | 933 ₹6,71,536.08 Lowest |
| 10.00 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand). | 49.88 | cu.m | 6,947 ₹3,46,516.36 | 6,952 ₹3,46,765.76 | 6,926 ₹3,45,468.88 Lowest |
Tender Value
₹9.2 Cr
EMD Value
₹18.5 L
Closing Date
19 Dec 2025, 12:00 pmClosed
GM(T)
UKKUVB, Rudrapur
Civil infrastructure and development work under PM E-Bus Sewa Scheme for Uttarakhand Transport Corporation in District Haridwar
2025_UAPMB_89434_1
e-nivida-715/2025
Open Tender
Civil Works
Item Rate
450 days
Haridwar
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
GM(T), UKKUVB, Rudrapur
₹18.5 L
20 Dec 2025
4 Dec 2025
19 Dec 2025
4 Dec 2025
19 Dec 2025
4 Dec 2025
Amount
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Earth work in excavation in trenches for foundation and for pipes cables etc. in ordinary soil including fitup to 1.5m and dressing of sides and ramming bottoms and disposal of surplus excavated earth as directed by the engineer with in a lead of 50m.
Filing available excavated earth in trenches ,plinth,sides of foundation tec.in layers not exceeding 20cm in the depth ,consolidation each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
Providing and laying in cement concrte 1:4:8(1cement :4fine sand:08graded brick aggregated 40mm .nominal size.) and curing complete excluding cost of form work in foundation and floors.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level
Centering shuttering including strutting, propping etc. and removal of form work Foundations, footings, bases of columns, etc. for mass concrete
Centering shuttering including strutting, propping etc. and removal of form work Columns, Pillars, Piers, Abutments, Posts and Struts.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Reinforcement for R.C.C work including straighting,cutting,bending ,placing in position and bending all complete TMT.
15mm thick plaster on the plain in side of mix 1:6 mortor
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and fixing concertina coil fencing with punched tape concertinacoil 600 mm dia 10 metre openable length ( total length 90 m), having 50nos rounds per 6 metre length, upto 3 m height of wall with existing angleiron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T.reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retainhorizontal, including necessary bolts or G.I. barbed wire tied to angle iron,all complete as per direction of Engineer-in-charge, with reinforced barbedtape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources)
Centering shuttering including strutting, propping etc. and removal of form work Lintels, beams, plinth beams, girders, bressumers and cantilevers
230th Brick work withcommon burnt clayF.P.S. (non modular) brick of class designation 75 in foundation & plinth in cement mortar 1:6
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
12mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar
6mm thick cement plaster of ceiling of mix 1:3 ( 1 cement : 3 fine sand) mortar
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Centering shuttering including strutting, propping etc. and removal of form work Suspended floors, roofs, landings, balconies and access platform
Half brick masonry with F.P.S bricks of class designation 75 in superstructure above plinth level up to floor five level in cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S.bars at every third course of half brick masonry (with F.P.S.bricks).
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 25mm thick pre-laminated medium density fibre board exterior grade ( Grade-I) IS: 14587:1998 marked with one side decorative and other side balancing lamination for cupboard shutters edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S.piano hinges conforming to IS:3818 marked with necessary screw etc all complete
Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer in-charge.
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement prime.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified floor tiles polished finish of size Size of Tile 600 x 600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :125x64x2.50 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m².
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth White Agaria Marble Stone.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cuRange of two urinal basins with 5 litre white P.V.C. automatic flushing cisterntting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing G.I. pipes complete with G.I. fittings andclamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall 15mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings andclamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall 25 mm dia. nominal bore
Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 25 mm dia. nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions 15mm nominal bore:
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. COUPLER 75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. COUPLER 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. BENDS 75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. BENDS 110 mm diameter
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms.18.51.1 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore D.S.R
Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms.
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cuRange of two urinal basins with 5 litre white P.V.C. automatic flushing cisterntting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm dia. nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm dia. nominal bore
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 10 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A DP MCB
S/F DP RCCB : Supplying and fixing following rating, double pole, (single phase and neutral), 30 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A FP MCB
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A FP MCB
S/F 4P RCCB : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
S/F 4P RCCB : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 10 sq. mm.
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 16 sq. mm.
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 120 sq. mm.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo mechanically treated bars
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 Rectangular shape 600x450 mm internal dimensions
Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS - 1729
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S&S as per IS - 1729
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long co mplete as per standard design With common burnt clay F.P.S. (non modular) bricks of classdesignation
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
Supplying, installation, testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.(Common For Sprinkler & Hydrant System) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 lpm at 88 m Head.
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head.
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 88 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for nclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head.
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing and fixing of pressure switches in MS pipe line including connection extra as required.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 250 mm dia
Supplying, fixing, testing and commissioning of double flanged sluice valve of PN 1.6 rating with non rising spindle ,bronze/ gun metal seat,ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required. 250 mm dia
Supplying, fixing, testing and commissioning of double flanged sluice valve of PN 1.6 rating with non rising spindle ,bronze/ gun metal seat,ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required. 200 mm dia
Supplying, fixing, testing and commissioning of double flanged sluice valve of PN 1.6 rating with non rising spindle ,bronze/ gun metal seat,ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required. 150 mm dia
Supplying, fixing, testing and commissioning of double flanged sluice valve of PN 1.6 rating with non rising spindle ,bronze/ gun metal seat,ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required. 80 mm dia
Supplying, fixing, testing and commissioning of NON - RETURN VALVE of following sizes conforming to IS 5312 complete with rubber gasket, GI bolts, nuts, washer etc as reuired 200 mm dia
Supplying, fixing, testing and commissioning of NON - RETURN VALVE of following sizes conforming to IS 5312 complete with rubber gasket, GI bolts, nuts, washer etc as reuired 150 mm dia
Supplying, fixing, testing and commissioning of NON - RETURN VALVE of following sizes conforming to IS 5312 complete with rubber gasket, GI bolts, nuts, washer etc as reuired 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia
Supplying, fixing, testing and commissioning of Butterfly valves PN 16 with bronze / gunmetal sheet duly ISI maked complete with nuts, bolts, washers, gasket conforming to IS 13095 of following sizes as required: 150 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Stainless steel
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30M
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way-150 mm dia M.S. Pipe
Fabricating and Installing following size of perforated Hot dip G.I cable tray including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and including painting etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Fabricating and Installing following size of perforated Hot dip G.I cable tray including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and including painting etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supply, Laying, Fixing, Testing and Commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper / aluminium conductor cable of 1.1 KV grade on existing cable tray / surface as required. 4 core x 2.5 Sq mm copper conductor armoured control cable.
Supply and making end termination with brass compression gland and copper/ aluminium lugs for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. 3 core x 10Sq.mm. Aluminium Armoured
Providing and fixing following size of GI strips/ GI wire etc. on surface or in recess for connections, including GI clamps etc. as required. 25 mm x 5 mm GI strip
Providing and fixing following size of GI strips/ GI wire etc. on surface or in recess for connections, including GI clamps etc. as required. 6 SWG dia G.I. wire
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
12 mm cement plaster finished with a floating coat of neat cement :1:4 (1 cement : 4 fine sand)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 1800 mm dia RCC pipes. (Laying by manual/ machanical means)
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil All types of soil 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.. 200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil.
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Clearing Grass and Removal of Rubbish Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201. (By Manual Means)
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5.
Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. Using naturally occuring gravel
Cement Concrete (PCC M-30) Pavement:- Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
Supplying of Surface mounted mirror optics light fixture suitable for 1 No. 18 watt LED Light complete as required. Bajaj : BZSSQL 18 W or equivalent.
Supplying of Planter light fitting miniature integral flood light luminaire 9W LED with pressure die cast aluminium housing (IP65) complete as required. Bajaj : BGSBL 9 W LED or equivalent.
Supplying of Wall mounted tube light fixture suitable for 1 No. 18 Watts LED light complete as required.LED closed batten extruded aluminium housing fitted with eng plastic and end plates complete as required. Bajaj : BCLSB 18 W or equivalent .
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply of 1200 mm. dia. Ceiling Fan complete as required.
Supply of EXOUST FEN complete as required.
Supply of LPI ESE Stormaster type Lightning Protection complete with the Lightning Air Terminal - Configured as a Spheroid which is comprised of separate electrically isolated 4 panels surrounding an earthed central finial. The Insulation material used to electrically isolate the panels (Stainless steel) shall be comprised of a base polymer which provides high Ozone & UV resistance with a di-electric strength of 24-38 KV/mm tested as per NFC 17-102 & IEC 60-1:1989. As per NF C 17–102, the ESE air terminal shall be tested with the “Switching Impulse Voltage” of 700 KV and “Direct Voltage” of 70 KV and certified by an international testing laboratory. The early streamer emission terminal shall be tested & certified by CPRI (Central Power Research Institute), Govt of India for the Impulse current of 45 KA (8/20 micro sec) with 5 positive & 5 negative impulse. The ESE Stormaster terminal shall be recommended from DGMS (Director General of Mines Safety), Govt of India. The ESE terminal shall not have any electronic circuit or any batteries inside to operate and it shall not depend on wind or solar to operate. The ESE terminal shall be tested and certified by any international laboratory as per IEC 60-1:1989 for an impulse current (8/20 micro sec) of more than 160 KA. The serial number displayed on theese lightning arrester shall be duly supported with the "certificate of country of origin" issued and duly sealed by the respective country (exported)" chember of Commerce & Industry" indicating the serial number of the product supplied. The ESE terminal shall offer protection radius of mtrs at Level III / Standard protection and perferably to bemounted on the roof top & centre. Make: LPI (Australia) Model: Stormaster 30 SS - 48mtrs (Level I / High Protection) (8/20 micro sec) with 5 positive & 5 negative impulse. The ESE Stormaster terminal shall be recommended from DGMS (Director General of Mines Safety), Govt of India. The ESE terminal shall not have any electronic circuit or any batteries inside to operate and it shall not depend on wind or solar to operate. The ESE terminal shall be tested and certified by any international laboratory as per IEC 60-1:1989 for an impulse current (8/20 micro sec) of more than 160 KA. The serial number displayed on the ese lightning arrester shall be duly supported with the "certificate of country of origin" issued and duly sealed by the respective country (exported)" chember of Commerce & Industry" indicating the serial number of the product supplied. The ESE terminal shall offer protection radius of mtrs at Level III / Standard protection and perferably to bemounted on the roof top & centre. Make: LPI (Australia) Model: Stormaster 30 SS - 48mtrs (Level I / High Protection) or equivalent.
Supply of Mast (G.I. pipe of 5 mtrs height) for mounting the terminal & adaptor with the Stormaster ESE Air Terminal along with supporting stray wires, etc.
Supply of heavy duty weather proof environment friendly polyplastic earth pit chamber with cover of autolocking facility with the following dimensions - 254mm dia (top), 330mm dia (bottom) and 260mm height. 4 knock-out openings are provided for the easy interconnection of earth strips between the earth pits to form a grid.
Supply of down conductor of 70 sq.mm single core insulated flexible copper cable with necessary accessories, etc.
Supply of Test Link Joint Kit in a IP 55 weather proof enclosure of suitable dimension etc. complete as required.
Installation cost of total Advance Lightning Protection System.
Supply, installation, testing & commissioning of Sub-Panels, cubicle type, made out of 2 mm thick CRCA sheet, totally enclosed, IP-42, free standing, floor/Wall mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars, including internal wiring with suitable size wires / cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories as per specifications. MAIN ELECTRICAL PANEL FOR NON-ESSENTIAL LOADS INCOMING 250 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-250 Amps digital ammeter with 250/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 6 Nos. 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and erection of the following equipment at suitable place in the sub-station building as required. M.S. Buckets (6 Nos.) of 15/20 litres capacity painted with Red Oxide paint & lettered as ‘Fire’ with White and mounted on free standing stand, as required including filling with dry sand.
Supplying and erection of the following equipment at suitable place in the sub-station building as required. First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross society conforming to IS : 2217 - 1963.
Supplying and erection of the following equipment at suitable place in the sub-station building as required. Shock Treatment Chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English)
Supplying and erection of the following equipment at suitable place in the sub-station building as required. Rubber Mat 914.4 mm. wide and 6 mm. thick to withstand 1.1 KV dielectric strength.
Supplying and erection of the following equipment at suitable place in the sub-station building as required. Supply and fixing of Dry Chemical Fire Extinguishers 5 Kg. as per IS: 2171-1976 mounted on wall hooks.
Supplying and erection of the following equipment at suitable place in the sub-station building as required. Providing and fixing Single Line Diagram duly mounted on a wooden frame with glass on, as required.
Supply, installation, testing and commissioning of 10 KVA TRUE ONLINE double conversion VFI Technology UPS (High frequency PWM using IGBT technology), Parallel redundant, Single Phase AC input & Single Phase AC output, 30 min backup, fully microprocessor based UPS system suitable for 220 VAC, +10% -10%, 50 Hz supply, variation +/- 1%, Power Factor-0.8. Battery consisting of following:- Galvanic Isolation Transformer at Inverter Input with Delta star connection to separate Input and Output Neutral. Input range should be 320 VAC – 480 VAC. IGBT Rectifier with each UPS. Fully microprocessor Digital Signal Processing (DSP) based with diagnostics capability . Maintenance by-pass module. Microprocessor based LCD display indication for various parameter's display & LED indication for alarm for major status parameters and provisions for remote indications. The system shall be as per detailed specifications and shall be complete with all connections / inter-connections & provisions for static bypass etc. with required accessories as required. Suitable size and Nos. of Valve Regulated Lead Acid (VRLA) Sealed Maintenance Free batteries in suitable numbers and Ampere hour capacity suitable for 10 KVA UPS system for providing 30 minutes back up time at full load, with interconnecting cables, mounting racks / stands for stacking the batteries, along with connections, interconnections and standard accessories etc. complete as required. (12V Cells, 5 year Design life). 10 KVA UPS
Supplying, Installation, Testing & Commissioning of 16 M high mast light
Supplying, installing, testing and commissioning of multistage centifugal pumpset with mechanical seal, CI casing & impeller, Carbon steel shaft connected to a TEFC induction motor of suitable rating, 415+ 10% volts, three phase, 50 Hz A.C. supply, complete with vibration isolators, base plate, foundation, including providing pump controller & level switches to start and stop the pump automatically at predecided levels of the water in the tank with provision of protection for dry run including wiring etc all panels should be MCB isolation DOL/ SD Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump. complete as required. Domestic & Flushing Water Transfer Pump Capacity - 650 LPM Head - 60 mtr HP -20 (2 No. of pump in 1 Set (1W+1S) Soft Water Transfer Pump Capacity - 250 LPM Head - 25 mtr HP - 4 (2 No. of pump in 1 Set (1W+1S)
Supplying, Installation, Testing and commissioning of submersible pump and electrical panel suitable for 8" dia casing of bore with SS impeller, high tensile SS shaft, copper wound squirrel cage directely coupled wet type induction motor 15 H.P. (minimum), 2900 rpm, suitable for operating on 415+10% V, 50 Hz,3 phase A.C. supply, conforming to ISS: 8034-1976, capacity 15 m3 per hour, at 150 mtr head, water lubricated bearings and provided with pivoted segment type thrust bearings to withstand non-vertical lead with minimum wear and tear and duly fitted with device to take up the expansion of water with heating of motor. The contractor to obtain approval for model and make of pumpset & suitable Electrical panel after having yield report of fully developed tube well and submit actual bore strata chart. including supplying laying and fixing 3 mtr water proof PVC insulated flat submersible cable 1x4Cx6 sqmm with end termination with its accessories. complete in all respect as required..
Supplying of following sizes PVC insulated and PVC sheathed Power cable of 1.1 KV grade armoured LT cable as required confirming to IS:1554/IS-7098 (Part-I) 1988 4C x 6 sq. mm.
Supplying of following sizes PVC insulated and PVC sheathed Power cable of 1.1 KV grade armoured LT cable as required confirming to IS:1554/IS-7098 (Part-I) 19884C x 10 sq. mm.
Supplying of following sizes PVC insulated and PVC sheathed Power cable of 1.1 KV grade armoured LT cable as required confirming to IS:1554/IS-7098 (Part-I) 1988 4C x 16 sq. mm.
Supplying of following sizes PVC insulated and PVC sheathed Power cable of 1.1 KV grade armoured LT cable as required confirming to IS:1554/IS-7098 (Part-I) 1988 3.5C x 120 sq. mm.
Supplying, laying & termination control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable between various sensors and system controller/starter etc. in pump house and out side on surface/existing cable tray complete with connections at both end with glands etc. as required. 8C x 2.5 sq. mm.
Supplying, laying & termination control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable between various sensors and system controller/starter etc. in pump house and out side on surface/existing cable tray complete with connections at both end with glands etc. as required. 6C x 2.5 sq. mm
Supplying, laying & termination control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable between various sensors and system controller/starter etc. in pump house and out side on surface/existing cable tray complete with connections at both end with glands etc. as required. 4C x 2.5 sq. mm
Supplying, laying & termination control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable between various sensors and system controller/starter etc. in pump house and out side on surface/existing cable tray complete with connections at both end with glands etc. as required. 2C x 2.5 sq. mm
Supply and Fixing D.G Set 200 KVA
SUPPLY OF SUBMERSIBLE PUMP 1500 LPM 80 HEAD KSB MAKE
S/F OF 50 HP ELECTRONIC PANNEL WITH MINI RTU SCADA
FLENGE
SUPPLY OF RUBBER PACKING SHEET FOR FLANGES
SUPPLY OF 150M DIA SLUICE VALVE
SUPPLY OF 150MM DIA REFLEX VALVE
SUPPLY OF 150MM DIA BAND
SUPPLY OF 150MM DIA TEE
100MM D/F PIPE
250MM DF CAP
REDUCER OF 150MM DIA SUBMERSIBLE PUMP
20MM RUBBER SHEET
NUT BOLT 2X5/8
25MM DIA SUBMERSIBLE CABLE
SITC OF PUMPING PLANT
EARTHING
DOZING PUMP
70MM ALMUNIUM CABLE
PROVISON 250 AMP WITH BOARD MAIN SWITCH 200A WITH HRC FUSE WITH ANGLE IRON FRAME CHANGE OVER SWITCH CFL ETC
60KVA SARVO
Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 .
Providing & fixing double flanged Rubber expansion bellow with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 200 mm dia
Providing & fixing double flanged Rubber expansion bellow with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications. 80 mm dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926.
SITC weather proof M.S Door and glass fire door size 750 mm x 600 x 250mm or as per arch. Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 750 mm x 600 x 250mm fabricated from 1.6mm thick M.S. sheets and M.S angle complete with glass, locking arrangements to accommodate the following: - a) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. b) Short branch - 1 No. c) Fireman's Axe - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade.
Supplying and fixing of Deluge Valve of 150mm dia with drain assebly complete as required with all acessores , contoler wiring etc complete in all respect
Providing and fixing fire extinguisher consisting of brand new high pressure steel cylinder bearing IS and having the approval of controller of explosives Nagpur, wheel type valve bearing IS mark internal discharge tube, high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. 4.5kg capacity cylinder (Co2)
Providing and fixing fire extinguisher consisting of brand new high pressure steel cylinder bearing IS and having the approval of controller of explosives Nagpur, wheel type valve bearing IS mark internal discharge tube, high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. ABC type extinguisher with cylinder fully charged with 6 Kg. capacity.
Providing and fixing fire extinguisher consisting of brand new high pressure steel cylinder bearing IS and having the approval of controller of explosives Nagpur, wheel type valve bearing IS mark internal discharge tube, high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. Co2 Type 9 kg
Providing and fixing fire extinguisher consisting of brand new high pressure steel cylinder bearing IS and having the approval of controller of explosives Nagpur, wheel type valve bearing IS mark internal discharge tube, high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. Co2 Type Trolley Mounted 22.5 kg
Providing and fixing fire extinguisher consisting of brand new high pressure steel cylinder bearing IS and having the approval of controller of explosives Nagpur, wheel type valve bearing IS mark internal discharge tube, high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed. Mechanical Foam Type Trolley Mounted 50kg
Supply, Laying, Fixing, Testing and Commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper / aluminium conductor cable of 1.1 KV grade on existing cable tray / surface as required. 3 core x 35 Sq.mm. Aluminium Armoured
Supply, Laying, Fixing, Testing and Commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper / aluminium conductor cable of 1.1 KV grade on existing cable tray / surface as required. 3 core x 10Sq.mm. Aluminium Armoured
Supply and making end termination with brass compression gland and copper/ aluminium lugs for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. 4 core x 2.5 Sq mm copper conductor armoured control cable.
Supply and making end termination with brass compression gland and copper/ aluminium lugs for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. 3 core x 35 Sq.mm. Aluminium Armoured
Supply, installion, testing and commissioning of UL / FM / VDS Approved Dual Action Addressable Manual Pull Station. It shall have Red Light Emitting Diode (LED) for the Alarm indicator and an Amber/Yellow LED for the Fault indicator. The Pull Station should have provision for a Metallic Key lock for Easy reset.The Pull Station shall have a translucent plastic panel at the center enabling the visibility of an internal LED & the LED should be visible even when the Pull Station is closed with Junction Box and other mounting accessories for proper installation. Make-Advanced/Apollo/Mircom/Secutron/Honeywell-Gamewell.
Supply, install, test and commissioning of UL / FM / VDS approved Analogue addressable Input module with inbuilt isolator / isolator Module with LED indicator to be supplied with Junction Box, Glands and other mounting accessories for proper installation. Make-Advanced/Apollo/Mircom/Secutron/Honeywell-Gamewell.
Supply of UL / FM / VDS approved Fire Panel Supervised Voice Evacuation Speaker with 25 & 70 volt line matching transformers and include output power taps of 1⁄4, 1⁄2, 1 and 2 watt(s). High dBA output (over 90 dBA at 10 feet @ 2 watts) with moulded terminal block connection & equipped with a ground wire and frequency response of 400 to 4000Hz for Voice Evacuation with suitable rating amplifiers with Fire alarm panel including. Make-Advanced/Apollo/Mircom/Secutron/Honeywell-Gamewell.
Over Head Fire Fighting Water Tank For Admin Block
Over Head Fire Fighting Water Tank For Workshop Block
Ratan Construction (BID ID -410811)
VRINDA CONSTRUCTIONS (BID ID -410791)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
doc.pdf
Tender Documents • 11.06 MB
BOQ_106049.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .