Executive Engineer SMD PHE Dte
Chetla
Providing Fire Station near BURIR KHAL beside Road no 6 connection Ganga Sagar Mela 2027 under South 24 Pgs. Mechanical Division, PHE Dte.
2026_PHED_5088250_14
WBPHE/EE/SMD/NIeT-30 of 2026-27
Open Tender
FIRE FIGHTING M/R
Item Rate
60 days
Ganga Sagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.0 L
21 Nov 2026
21 Nov 2026
3 Dec 2026
21 Nov 2026
1 Dec 2026
21 Nov 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, delivery & storage at site diesel engine driven horizontal centrifugal end suction top delivery fire fighting pump conforming to TAC Norms complete with pump, diesle engine, coupling, coupling guard, local panel, maintenance free battery, battery charger, fuel tank and all other accessroies as per technical specification.
Capacity : 137m3/Hr. Generated Head : 70 MWC (Min) Engine KW at 1500 RPM (94 HP) | 1 | Set | - | - |
| 2 | Supply, delivery & storage at site centrifugal pump for use as Jockey Pump for firefighting system, complete with coupling, coupling guard, common base frame for pump motor set (skid mounting) having the following duty parameters:-
Capacity : 11.0 Cum/Hr.
Generated Head : 75 MWC
Speed : 3000 rpm (Syn) max.
Duty : On/off service as Jockey Pump
No. of Stage : 4 Max.
Type : End suction top delivery/radically split multi stage.
MOC : Casing : IS 210 FG 260
Impeller : Bronze
Shaft : EN 8
Installation : Outdoor, temporary
Pumping Fluid : Clear water at ambient temperature.
The Pump should be positive suction, shaft sleeve: SS 410, wiring ring (casing) : CI IS 210 FG 260
[Make: Flowmore/M&P/WPIL/KBL] (2 Sets in One Station)
TC of pump needed. Riverine charges @5% included. | 2 | Each | - | - |
| 3 | Supply, delivery and storage at site horizontal floor mounted squirrel cage induction motor of suitable rating for the above pump for Jockey application.
The motor will be installed on the pump motor skid and shall have auto start/stop based on procure sensing as described in the operating philosophy.
Motor rating to have minimum 25% margin over duty point BKW of the pump. The motor should be IE-3, IP-55 (W), IS: 12615, 11KW 415V, 50Hz., ±5%, Class-F, 2 Pole, TEFC, 500C. [Make: ABB/Marathon/CGL/Siemens] (Two Nos. in One Station)
TC of motor needed. Riverine charges @5% included. | 2 | Each | - | - |
| 4 | Supply, delivery and storage at site of DN 150 mm ERW medium Pipes with bends, flanges, reducers, enlargers, tee, all complete with nuts, bolts, wahsers for suction and delivery line including supply of DN 150 mm Non Return Valves, Bellow, Gate Valves & Globe Valves. | 1 | LS | - | - |
| 5 | Supply, delivery and storage at site of Dn 50 mm MS ERW medium Pipes with flanged, and other fittings to connect the Jockey Pumps with the Engine and with the system including supply of 50 mm Gate and Non Return Valve, nuts, bolts all complete with pressure gauges, syphon all complete as per direction of the EIC. | 1 | Set | - | - |
| 6 | Supply, delivery and storage at site free standing, outdoor type portable MCC cum Control Panel for the Jockey Pumps to perform as applicable. The pump shall have star-delta starter and have auto operation based on header pressure. There shall be signal communication between this panel and panel for fire pump for auto starting of the fire pump with alarm. The panel should have one no. spare starter, fuse less PDB & MCB/MCCB, DOL starter with Type-2 contactor, 80 Micron Epoxy painted, FRLS wiring, MPCB/MCCB/MCB needed, power contactor Siemens/ABB, IS: 8623, IP-65 preferred. TC of Panel needed. Reverine Charges @ 5% included. | 1 | Set | - | - |
| 7 | Supply, delivery & storage at site necessary 3M pressure switches and two nos. pressure gauges with isolation valve and depressurization valve with required impulse tubes for auto operation of fire pump and Jockey Pumps. Riverine Charges @5% included. | 1 | Lot | - | - |
| 8Supply, delivery and storage at site following cables:- | |||||
| 8.01 | 1.1KV grade, 3.5C, 35 sq. mm XLPE insulated AL AR cable confirming to IS: 7098 (Pt-II) with latest amendment for Incomer Panel. [Make: Gloster/Polycab/Crystal]. TC of cable needed. Reverine charges @5% included. | 75 | Mtr. | - | - |
| 8.02 | 1.1KV grade, 3C, 2 x 16 sq. mm XLPE insulated AL AR cable confirming to IS: 7098 (Pt-II) with latest amendment for Panel to Jockey Pump. [Make: Gloster/Polycab/Crstal]. TC of cable needed. Reverine charges @5% included. | 50 | Mtr. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tendernotice_2.pdf
PDF • 1.01 MB
Tendernotice_3.pdf
PDF • 0.27 MB
BOQ_5218688.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .