Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC 00 IN FRONT OF SHIVPURI HOTEL NEAR KOTHI NO 14 SHIVPURI MADHYA PRADESH 473551 | SHIVPURI | MADHYA PRADESH | 473551 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.8 L+₹40,750.35 (1.49%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹28.2 L+₹80,275.55 (2.93%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹28.4 L+₹98,930.75 (3.61%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹28.5 L+₹1.1 L (4.12%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
23 Dec 2020, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVN OF CYBER CUM AV ROOM AND EXTERNAL SERVICES FOR MMCB COMPLEX AT INS SARDAR PATEL PORBANDAR
2020_MES_399836_1
9051/PBR/E8
Open Tender
Civil Works
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Navy
₹56,000
Yes
22 Jan 2021
2 Dec 2020
25 Dec 2020
2 Dec 2020
23 Dec 2020
17 Dec 2020
3 Dec 2020 - 16 Dec 2020
Amount
Surface dressing not exceeding 15 cm deep in hard and dense soil and getting out complete all as specified. Note:- Area of surface dressing and surface excavation are not payable simultaneously.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation,laying cable , pipe line etc, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation,laying cable , pipe line etc., n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation,laying cable , pipe line etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / disintegrated rock complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out in hard dense soil, complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/ disintegrated rocks, complete all as specified and as directed.
Excavation over areas exc 1.5 m but n exc 3.00m deep and getting out in soft/ disintegrated rocks, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard dense soil, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/disintegrated rock, complete all as specified.
Removing excavated material (soils)to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point.
Removing excavated soils exc. 500m and upto total distance 1.5Km and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated rock exc. 500m and upto total distance 1.5Km and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material to a distance exc 250m and n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point as in soft/disintegrated rocks, all as specified and as directed.
PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Mild steel CRS bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Mild steel CRS bars 8mm dia as in stirrups spacer and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footing plinth beams, bases for column etc. complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in Columns, Pillars, Piers, Posts and Struts complete all as specified and directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed .
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in roof slab supported on walls, beams and columns in roofs, complete all as specified and as directed.
RCC M-30 (Design Mix) (using 20 mm graded crushed stone aggregate) as in chajjas complete all as specified and directed.
Use and waste of Form work to sides of concrete foundations, footings, bases of columns and plinth beams and similar work, complete all as specified and directed .
Use and waste of Form work to sides of columns, square, rectangular, complete all as specified and directed .
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup, ports, overhangs, etc. also splays between floors and beams complete all as specified.
Use and waste of Form work to sides and soffits of suspended slabs such as roof slabs, floor slabs and similar work n exc 200 mm thick (horizontal or sloping) complete all as specified and directed.
Use and waste of Form work to sides and soffits of chajjas and like and similar work n exc 200 mm thick (horizontal or sloping) complete all as specified and directed.
Stone masonry walling or squared walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Moorum / red bajri filling in floors or pavings, laid in layers n. exc. 150 mm thick, spread, levelled and well rammed including watering, complete all as specified and directed.
Hard core of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 150 mm thick, watered and rammed to a true surface, before concerting or otherwise complete all as specified and directed.
Treating the top surface of filled earth with anti termite emulsion at the rate of 5 litres per square metre of surface area, complete all as specified and as directed.
Treating the soil under plinth protection with anti termite emulsion at the rate of 5 litres per square metre of surface area, complete all as specified and as directed.
Treating the bottom and sides of excavation with anti termite emulsion at the rate of 5 litres per square metre of surface area, complete all as specified and as directed.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
75mm thick PCC 1:3:6 , type C-1 using 20mm graded stone aggregate as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1) complete all as specified.
75mm thick PCC type D2 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed.
Vitrified coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering 15 mm thick in cement mortar 1:6 Complete all as specified and directed.
Vitrified Ceramic tiles 10 mm thick (square / rectangular) area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 12 mm thick in cement mortar 1:4 complete all as specified and as directed.
20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,over and including bedding layer 20mm thick 1:6, Complete all as specified and directed.
Rendering 5 mm thick on fair faces of concrete surfaces as on ceiling surface, facia and projection of slabs, finished surfaces even and smooth without using extra cement, in CM (1:3) complete all as specified and directed.
Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified.
Rendering 20 mm thick in two layers (15+5mm) ,on fair faces of stone masonry surfaces or concrete surfaces in cement mortar 1:4 finished even & smooth with out using extra cement including use of water proofing compound in outer layer, complete all as specified and directed. (Note- Water proofing compound shall be measured and paid separately).
Preparation of newly plastered surfaces and applying three coats of white wash complete all specified and directed.
Preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over 2mm thick wall care putty complete all specified and directed.
Preparation of newly plastered surfaces of walls, soffits & facias of beam ,chajjas etc applying two coats of weather proof Acrylic based exterior emulsion paint over a coat of primer complete all as specified.
10 mm thick (average) bedding layer on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, mixed with WPC, finishing even and smooth without using extra cement complete all as specified and as directed. Note: WPC &APP measured and paid separately.
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane.
4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) preprimered self embossed, textured designer board E-Board Classic to be fixed on aluminium snap grid/section size 605mmx605mm with main runner, cross tee and wall angle duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including making cutting for fixing light fixtures of any size and shape, complete all as specified and as directed.
12mm thick toughened float glass with grinded and rounded edged for fixing as door shutter, window shutter including pre drilled holes and notching for fixing patch fittings (including Patch fittings) , complete all as specified and as directed.
12mm thick toughened float glass with grinded and rounded edged for fixing as wall panels, including pre drilled holes and notching for fixing patch fittings (including Patch fittings) , complete all as specified and as directed.
Plain cement concrete 1:3:6 type C2 (using 40mm graded aggregate bed to drain pipes including packing under and haunching against the sides of pipes of 150mm bore after they are laid and tested complete all as specified and as directed.
Reinforced concrete pipes 150 mm bore , class NP3, laid and jointed complete with collars
PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in benching in man hole all as specified and directed.
Stone masonry walling or squared walling in cm 1:4, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
MS framed work such as grills, gratings, etc with ends of bars shoulders or riveted or forged in to spikes, framed guard bars , rungs ,screen and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and as directed.
Precast reinforced cement concrete M-30, using 20mm graded stone aggregate as in baffle wall, cover slab (for manhole) including use & waste of form work for fair finished surfaces complete all as specified and directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement complete all as specified.( NOTE:- Water proofing compound will be measured and paid separately)
Supply only integral water proofing compound.
100mm dia PVC slotted vent cowl, complete all as specified and directed.
110mm bore PVC (SWR) pipes of pressure rating 6 kgf / cm2, single socketed in any length with rubber ring, fixed to wall with clamps complete all as specified and directed.
PVC (SWR) bends, 110mm bore any radius with cement joints complete all as specified and directed.
INTERNAL ELECTRIFICATION
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and all as directed at site for following.
One light/ fan point controlled by one one way switch.
One 5 Amps 3/5 pin socket outlet on same board with other switches.
One 5 Amps 3/5 pin socket outlet on indipendent board .
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for independent switch socket outlet 6 pin 5/15 Amps and all as directed at site.
Switch piano flush type 5/6 Amps single pole one way 230 Volts complete all as specified.
Switch piano flush type 15/16 A single pole one way 230 V complete all as specified.
Socket Outlet 2 in 1 3/6 pin 5 Amp flush type 230 V,complete all as specified and as directed.
Socket Outlet 3 pin 15 Amps flush type 230 V,complete all as specified and as directed.
Fan regulator electronic stepped type heavy duty Two module, 230 volts flush type complete all as specified.
Ceiling rose surface Bakelite, 65x50mm, 3 terminals complete all as specified and directed.
Sub main wiring concealed with 4 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable 1100 V grade, drawn into and including rigid non-metallic PVC concealed conduit 20mm dia or higher, class 'B' complete with all PVC conduit accessories including 2.5 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to common earth point all as Specified and directed by Engr-in-Charge.
Sheet metal enclosure DB ,Single pole and neutral with 100 Amps rated bus bar,230 volts, double door type ,8 way DB including connecting all connections of wire to MCBs with proper lugs & arrangements all as specified and directed by Engr-in- charge.
MCB TPN, 415 volts, 63 amps of breaking capacity 10 KA C curve,complete all as specified and directed
MCB SP 240 Volts AC 6 - 40 Amps of breaking capacity 10 KA C curve, complete all as specified and directed .
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Earth continuity conductor or main Earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop Earthing etc. as required using GI Wire 4 Sqmm as Earthing lead.
Recessed mounting full glow 2'X2', LED Retrofit panel 36 watt cool day light ,glare free uniform illumination extruded metal/aluminium body, electronic LED driver, connector block with all accessories internal prewired & connecting with 2 core flexible copper conductor cable of suitable size complete all as specified and as directed. Make - Crompton, Cat No-AURA I LCTPL-36-CDL(2X2) or equivalant Model of make specified in Appx B.
Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.
LED security light 30 watt, IP 65 grade, glare free uniform illumination extruded metal/aluminium body, electronic LED driver, connector block with all accessories internal prewired & connecting with 2 core flexible copper conductor cable of suitable size complete all as specified and as directed. Make -Crompton freedom LSTS -30-CDL or or equivalant Model of make specified in Appx B.
EXTERNAL WATER SUPPLY
Gun mental globe or gate valves, with iron wheeled head screwed both ends of iron pipes for 50 mm bore pipe fixed Complete all as specified and directed.
Gun mental globe or gate valves, with iron wheel head screwed both ends of iron pipes for 25 mm bore pipe fixed Complete all as specified and directed.
Gun mental globe or gate valves, with iron wheel head screwed both ends of iron pipes for 20 mm bore pipe fixed Complete all as specified and directed.
Galvanised steel water tubing 50 mm dia medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc) and fixing to wall complete with clips, wall hooks, wooden plugs, or laying in trenches etc.,also cutting, screwing and waste and for making forged bends on piping as required at site, all as specified and directed.
Galvanised steel water tubing 25mm dia medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc) and fixing to wall complete with clips, wall hooks, wooden plugs, or laying in trenches,etc.,also cutting, screwing and waste and for making forged bends on piping as required at site, all as specified and directed.
Galvanised steel water tubing 20mm dia medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc) and fixing to wall complete with clips, wall hooks, wooden plugs, or laying in trenches,etc.,also cutting, screwing and waste and for making forged bends on piping as required at site,all as specified and directed.
Construction of valve chambers 600 mmx600mmx600 mm with 15 cm thick solid concrete block masonary, block casted using PCC 1:3:6 type C-1 mix built in cement and sand mortar 1:4, 15 mm plaster to internal surfaces and external surfaces up to 15 cm below ground level and top of floor in CM 1:4 finished even and smooth without using extra cement, 3 mm thick MS sheet cover including 40x40x3 mm MS angle frame embedded in 150 mm thick PCC 1:2:4 type B-1, with 25x6 mm flat iron hold fast, handles, hinges with locking arrangements, applying one coat of red oxide primer and two coat of synthetic enamel paint to all steel surface and earth work in soft /disintegrated rock disposal of surplus soil to a distance n.exc.50 m. complete all as specified and directed.
EXTERNAL ELECTRIFICATION
XLPE insulated armoured (under ground) heavy duty electric cable with standard aluminium conductor 1100 Volts grade of cross sectional area 70 sqmm 3.5 core laid in trenches/ducts/through pipes /in floor road/along the pole etc complete all as specified.
XLPE insulated armoured (under ground) heavy duty electric cable with standard aluminium conductor 1100 Volts grade of cross sectional area 35 sqmm 3.5 core laid in trenches/ducts/through pipes /in floor road/along the pole etc complete all as specified.
Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
GI tubing light grade 100 mm Dia bore for cable protection, laid under plinths/floors/roads/culverts or fixed on walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc complete all as specified.
GI tubing light grade 50 mm dia bore for cable protection, laid under plinths/floors/roads/culverts or fixed on walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc complete all as specified.
cable route indicator 15 cm dia made out of cast aluminium duly marked with size and type of cable fixed on 25X25X3mm angle iron of 45 cm long support embedded in PCC 1:3:6 type C1 of size 250X250X300mm and painting to angle iron with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
MCCB 63 Amps, 4 pole, 25 kA Breaking Capacity, 415V AC, 50Hz, (Conforms to IEC:60947-II / IS:13947-II) with outdoor encloser for main connection from Existing panel with all accessories. Make-L&T DN0-100D Cat no. CM97919OOF2OG or Eq model of make mentioned in Appendix B.
Cable jointing kit for 1100 V (Earthed) grade cable for Straight through joint heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm fixing complete all as specified and as directed.
Cutting of hard standing/ Road for laying of pipe line/cable and making good surfaces by using PCC 1:2:4 type B-2 after laying of pipe line/ cable up to 30cm in depth and removing rubbish outside MD land complete all as specified and as directed.
Earthing complete with galvanised with galvanised steel heavy duty pipe electrode 40 mm bore, medium grade, 2.5 mtr in length buried directly in ground vertically with top edge not less than 1.25 metres below normal ground level (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Rectangular LED Flood Light 150 Watt with innovative thermal management glare free uniform illumination extruded metal/aluminium body, electronic LED driver, connector block with all accessories internal prewired including 40mm GI light grade tubing nut nolts, clamps and all accessories required as per site , compete all as specified and as directed Engineer - in- charge. Make -Crompton Cat part No-LFLN-150-CDL/60 or equivalant model of make specified in Appendix B.
CPRI approved factory fabricated, out door type, LT Panel Board made out of CRCA Sheet 3.15 mm thick (Outer) and 2mm (Internal), duly pre-treated in 7 tank process powder coated in Siemens grey colour inside and out side with IP-54 protection and with projected globe roof for rain water protection dust and Vermin Proof , Double door (hinged) with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 40X40X5mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with copper bus bar TPN 200 Amps rating duly covered with heat shrinkable sleeves of colour coded duly fixed on DMC/SMC insulators including control wiring with PVC insulated, flexible, multistrand copper conductor cables of adequate size and adequate length, control fuses duly ferruled, crimped with suitable lugs/thimbles, PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–
(a) MCCB 100 Amps, 36 KA,4 Pole, 415 volt, 50 Hz thermal, magnetic adjustable type -1No (Incomer)
(b) MCCB 63 Amps, 16 KA, 4 Pole,415 volts,50 Hz - 2 No
(c) MCB 63Amp TPN 02 nos
(h) LED phase Indication lamp showing R-Y-B phases- 01 set
m/s.a.t.odedra
SURAJ ENTERPRISE
SHREE CHAMUNDA ENTERPRISE
BABUBHAI BHIMABHAI PANDAVADRA
OM ENTERPRISE
Vastushilp Building Designer
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .