Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹80.2 CrAccepted-AOC | ₹80.2 Cr Quoted ₹94.7 Cr | 1 | Accepted-AOC QCBS Winner |
| 2 | 2₹78.3 CrRejected-Finance REGISTERED OFFICE CORPORATE OFFICE OUTER RING ROAD NAGAVARA BENGALURU KARNATAKA 560045 | BENGALURU URBAN | KARNATAKA | 560045 | ₹78.3 Cr | 2 | Rejected-Finance 90.40 final score in QCBS |
| 3 | 3₹87.0 CrRejected-Finance | ₹87.0 Cr | 3 | Rejected-Finance 90.00 final score in QCBS |
| 4 | 4₹117.3 CrRejected-Finance | ₹117.3 Cr | 4 | Rejected-Finance 88.95 final score in QCBS |
Tender Value
₹80.7 Cr
EMD Value
₹1.8 Cr
Closing Date
27 Oct 2020, 5:00 pmClosed
Chief Executive Officer
4th Floor, Felicity Square, Statue
Selection of Master System Integrator for Integrated Command Control Centre (ICCC) in Thiruvananthapuram
2020_SCTLT_390811_1
SCTL/PRJ/236/2019-IT/ICCC- RFP2
Open Tender
Miscellaneous Works
365 days
Thiruvananthapuram
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,850
Yes
Online
₹1.8 Cr
Yes
19 Jan 2021
9 Oct 2020
28 Oct 2020
10 Oct 2020
27 Oct 2020
14 Oct 2020
10 Oct 2020 - 13 Oct 2020
Amount
ICCC Platform Software Components charges
Supply of ICCC Software Platform as per the specifications described tender functional and technical requirements
Supply of Citizen Engagement Platform with Chatbot and Web Portal for Thiruvananthapuram Smart City
Supply of Enterprise Service Bus (IoT and Middleware) for ICCC Platform
Supply of Enterprise GIS Software platform for ICCC Software and other third party applications mentioned in technical and functional requirements
Supply / Development, installation and configuration of Thiruvananthapuram One City One Mobile Application as per the specifications described in technical and functional specifications
Creation of Analytics & dashboard for ICCC Platform : Situational Awareness -Map based /Video based, Incident Management layer, SOP Execution Layer, Notification System, Social media Integration and sentiment analysis
ICCC AI /Bigdata Platform : With machine Learning for predictive servicing as per the detailed
Integration charges of Existing third party applications to ICCC Platform
Integration of TSCCC - ITMS, ATCS and General Surveillance system to ICCC platform.
Integration of Information Kiosks with central content management system of ICCC Platform
Integration of Heritage Trails & Walks Mobile App to ICCC platform
Integration of Solar SCADA - software to ICCC platform
Integration of Smart Lighting application to ICCC platform ( upcoming application)
Integration of E - Gov services of Thiruvananthapuram Corporation as described in detailed functional and technical requirements
Integration of E - Gov services developed by Information Kerala Mission for Thiruvananthapuram corporation as described in detailed functional and technical requirements
Integration of Mosquito Density System to ICCC platform
Integration EV Charging Stations functional to ICCC platform
Integration of Booking & Tracking of E- Autorickshaw application to ICCC platform
Integration of Medical/Health Services applications as required by Thiruvananthapuram Smart City
Integration of Educational Department Services with ICCC platform
Installation and customization charges for ICCC Software Components
Installation and configuration charges for the ICCC Platform applications and mobile apps
Installation and configuration charges for the Enterprise GIS Platform
Kerala Water Authority Smart Metering application and Hardware
Supply , installation and configuration of web based Master data integration software for KWA
Supply and installation of Mobile Application for Field users and for Public
Integration of Master data integration software to KWA existing billing system
Integration of KWA software to ICCC platform with for visualisation, analysis and prediction purposes
Supply of Smart Water Meter - as per the specifications described tender functional and technical requirements
Supply of Smart Water Meter - Smart water meter 25 mm - as per the specifications described tender functional and technical requirements
Supply of Smart Water Meter - Smart water meter 40 mm - as per the specifications described tender functional and technical requirements
Supply of Bulk Meter - Smart water meter 50 mm - as per the specifications described tender functional and technical requirements
Supply of Bulk Meter - Smart water meter 250 mm - as per the specifications described tender functional and technical requirements
LoRA WAN Setup – Hardware for setting up Advanced Metering Infrastructure. Supply , Installation and setting up of LoRA Gateways
LoRA WAN Setup – Hardware for setting up Advanced Metering Infrastructure. Setting up of LoRA network Tower, connectivity devices and accessories for LoRA network
Supply and installation of Water Quality Check Sensors (Turbidity, Dissolved Oxygen)
Installation & Commission charges of Smart water meter - 15mm, 25mm, 40mm
Installation & Commission charges of Smart water meter - 50mm
Installation & Commission charges of Smart water meter -250mm, Flow meter - 250mm along with precast chambers
Installation & Commission charges of Water Quality Check Sensors
KSRTC ITMS Software and related Hardware and accessories
Supply, installation and configuration of Integrated Transit Management System with scheduling software for KSRTC use along with City bus Passenger Information System(PIS) for public use as per the scope defined in RFP
Supply and installation of Mobile Application for PIS for use of Public and department team
Integration of ITMS and Mobile app to ICCC platform
GIS Survey charges of the depots, bus routes and bus stops and creating Geo fencing on the map and plotting on the maps with the bus routes, depots and bus stops as required for KSRTC for city buses routes. Creating various master data – bus stop, routes, depots, buses, crew, etc.
Supply of GPS Tracking Device (AIS140 device Standard supported) with SIM as per the technical specifications mentioned in RFP
Supply of LED based PIS Boards on bus stops ( For remote bus shelters), as per the specifications mentioned in RFP
Supply of LED based PIS Boards on bus depots, Railway stations and Airport, as per the specifications mentioned in RFP
Supply and installation of Display system 4 No 50” LED TV with PC and control software to position in KSRTC control room
Installation charges for KSRTC System hardware equipments .Installation charges of LED Boards with necessary Electrical cabling and other infrastructure in bus stops and depots as required to connect to nearest power source, and approval charges
Installation charges for KSRTC System hardware equipments .Installation charges of LED Boards with necessary Electrical cabling and other infrastructure in bus stops and depots as required to connect to nearest power source, and approval charges
City Parking Management Solution
Supply installation and configuration of Centralised Parking Management Software for SCTL and integration of the same with ICCC platform, as described in RFP
Supply installation and configuration of Mobile application for Public use as per the requirements described in RFP
Supply installation and configuration of Mobile application for department use (for fee collection / attendance management monitoring etc) as described in RFP
Supply and installation of Cameras for Identified locations for parking management / surveillance purpose
Supply and installation of Variable Signboards in all identified parking areas
Supply of Mobile Devices for officers for fee collection
Supply and Installation of RACK , UPS, Network Switches , GI Poles, Electrical & LAN cabling in sites
Site Preparation- Painting and marking of parking bays
City Environment Monitoring system
Supply, Installation and configuration of Software solution for Environment Sensor data monitoring and integrating the same with ICCC platform
Supply and installation of Environmental Sensor (GSM Based)
Supply and installation UPS with enclosures, Electrical cabling etc in locations
Supply and installation of GI Poles and accessories for mounting of Sensors as required
ICCC Video wall
Supply of ICCC Videowall as per the specifications described tender functional and technical requirements
Supply of Video Wall Controller and Server with Software
Cables and stands as required for the Videowall installation
Data centre Build Components
Supply of Smart RACK as per the specifications described tender functional and technical requirements
Supply and installation of 32 Port IP KVM Switch with Cables & Accessories
Supply and installation of 1 U Foldable 18" TFT Monitor Integrated with Keyboard & Mouse
Supply of Network passive cables (Fibre and Cat6), Wall mount Racks and accessories for ICCC building as per the specification and detailed BoM enclosed in RFP
Supply and installation Raised False Flooring work in DC Room as per specifications enclosed in RFP
Supply of Modular UPS as per the specifications described tender functional and technical requirements
Data centre- IT Equipments
Supply of ICCC Core Router
Supply of ICCC Internet Router
Supply of Central Core switch
Supply of 24 port 10/100/1000 Access Switch with 2 10G uplink ports for external connectivity to videowall room as per the specifications described tender functional and technical requirements
Supply of 24 port 10/100/1000 Access Switch with 2 uplink ports for external connectivity for IP Phone / camera etc as per the specifications described tender functional and technical requirements
Supply of Wireless Access controller
Supply of Indoor wireless access point
Supply of SSLi in HA for SSL packet inspection and create loop for firewall and other security solution
Supply of Next generation firewall In HA with management license
Supply of Link Load balancer
Supply of Server load balancer with WAF
Supply of Anti- APT appliance solution with 5-year support
Supply of EDR solution- End point Detection and Response solution for 50 users
Supply of Application server-ICCC, GIS & integration solution- (The server sizing and specifications mentioned is as per DPR sizing and is the minimum required one. Bidders need to assess and consider additional server numbers / virtualization details etc as per the individual technology stack proposed)
Supply of Database server for the database used as part of the solution (bidders need to assess and propose the number of DB servers as per the technology stack proposed)
Supply of Directory Server - directory solution
Supply of Server for deployment of web application (bidder need to asses and size the web server numbers and size as per the application stack proposed )
Supply of Backup Server
Supply of Primary Storage - as per the specifications described tender functional and technical requirements
Supply of Secondary Storage as per the specifications described tender functional and technical requirements
Supply of Backup software for periodic backup and replication of data into various solutions including DC /DR application level replication
Supply of Tape library for Backup solution
Supply of Licenses for operating system
Supply of Virtualization solution - License for virtualization (if any), bidders need to asses and size the virtualization requirements as per technology positioned)
Supply of Directory for Server and CAL- Active directory licenses
Supply of NMS EMS for management and monitoring of ICCC hardware devices
Supply of SIEM-For monitoring Security logs from appliances
Supply of DDoS Appliance
Supply of Higher end Workstation for video wall room
Supply of Desktop System for video wall room, front desk, supporting staffs
Supply of Heavy duty Multi-Function Laser Printer
Supply of Multi-Function Colour Laser Printer
Supply of WiFi Colour InkTank Printer - A4
Supply of Interactive White Board
Supply of 65" or higher Smart TV for Conference rooms
Supply of Front desk KIOSK
Supply of IP Surveillance Camera for ICCC building
Supply of Access Control System with attendance management Software
IP PABX System with ISDN PRI Licenses
Supply of Contact Centre solution and Agent License/ Supervisor Lic / call recording Licenses as required
Supply of Gateway
Supply of IP Phones for call centre staff
Supply of IP Phones for ICCC office use
Supply of Video IP phones
Supply of Citizen Emergency Notification system and integration with ICCC Software platform
Supply of Video conferencing System for Videowall WAR room per requirements mentioned
Supply of Video conferencing System for 1st floor conference room as per requirements mentioned
Supply of Multiparty Conferencing Unit
Installation and configuration charges ICCC - DC Hardware
Installation of Network passive cabling (Fibre and Cat6) and accessories for ICCC building as per the specification and detailed BoM
Installation and configuration charges for DC Servers , Storage , Switches , Routers , Security components, CC solution, peripherals and other accessories in ICCC building
Installation and commissioning of SMART RACK in ICCC DC space
Installation and Commissioning of UPS in ICCC space
Installation and commissioning of Videowall in ICCC space
Equipments for Temporary Setup in Thiruvananthapuram corporation premise.
ABD Projects - ICT services on Smart Bus Shelter
2 MP IR Speed Dome PTZ Camera
4 channel Network Video Recorder With 1 HDD Bay Supports 4# POE Ports, HDMI, VGA and ONVIF
NVR: 16 IP Cameras input
Media Convertor with Two Lan Port
SC/LC patch card 1 mtr
6 TB Hard Disk
CAT 6 Cable
2U Rack
4U Rack
Pole With mounting bracket
PVC Pipe
1 KVA UPS with Battery - with 30 min backup
Emergency Call Box with button, speaker and microphone, Voice recorder – 4 channel, Head phones
Emergency Call Box Software/Hardware for Control Room
LED based PIS System
PIS System accessories for the installation
Wi-Fi Hotspot Device
Installation and commissioning
ABD Projects - Charithra Veedhi
2 MP IR Speed Dome PTZ Camera
2 MP IR Bullet Camera
NVR: 8 IP Cameras input
PoE Switch 8 Port
Media Convertor with Two Lan Port
SC/LC patch card 1 mtr.
6 TB Hard Disk
CAT 6 UTP Cable
2U Rack
Pole With mounting bracket
PVC Pipe
OUTDOOR LED VIDEO WALL
Multimedia Player (TB4) covered up to 1.3 Millions pixels
Installation and commissioning
GSM ECB Mother Board
GSM Antenna
Speaker
Solar Panel
Solar Charge Controller
Solar Panel Removed Sensor (Magnetic Switch Contact a Sensor)
Battery
MS Pole with Water Proof Cabinet, With Lock & Key
Installation and commissioning
ABD Projects - Childrens park
2 MP IR Speed Dome PTZ Camera
2 MP IR Bullet Camera
NVR: 8 IP Cameras input
PoE Switch 8 Port
Media Convertor with Two Lan Port
SC/LC patch card 1 mtr
6 TB Hard Disk
CAT 6 Cable
2U Rack
Pole With mounting bracket
PVC Pipe
Installation and commissioning
GSM ECB Mother Board
GSM Antenna
Speaker
Solar Panel
Solar Charge Controller
Solar Panel Removed Sensor (Magnetic Switch Contact a Sensor)
Battery
MS Pole with Water Proof Cabinet, With Lock & Key
Installation and commissioning
ABD Projects - MLCP - Thampanoor
2 MP IR Speed Dome PTZ Camera
2 MP IR Bullet Camera
NVR: 16 IP Cameras input
PoE Switch 24 Port
Media Convertor with Two Lan Port
SC/LC patch card 1 mtr
6 TB Hard Disk
CAT 6 Cable
2U Rack
4U Rack
Pole With mounting bracket
PVC Pipe
Installation and commissioning
Hydraulic high speed boom barrier arm Upto 3 Mtr length 1.5-3 sec closing 100% duty cycle with push button
Hydraulic high speed boom barrier arm Upto 2Mtr length 1.5-3 sec closing 100% duty cycle with push button
Loop sensor with communication model &SMPS(entry &exit location ) - 2 each at entry and exit
Parking Access Reader on the boom barrier
Parking access controller with enclosure &Accessories
4 Digit Led Matrix display at main gate H type mounting from ground
Parking counting controller with supporting accessories
Electronic Ticketing Machine - Entry and Exit with barcode reading facility
SIM Card - Entry and Exit
PC with Parking Management Software, API and connectivity
Installation and commissioning
ABD Projects - Palayam Market
2 MP IR Speed Dome PTZ Camera
2 MP IR Bullet Camera
NVR: 16 IP Cameras input
PoE Switch 24 Port
Media Convertor with Two Lan Port
SC/LC patch card 1 mtr
6 TB Hard Disk
CAT 6 Cable
2U Rack
4U Rack
Junction Box (200 mm x 160mm x 98mm)
Pole with mounting bracket
PVC Pipe
LED Display Screen
Installation and commissioning
Hydraulic high speed boom barrier arm Upto 3 Mtr length 1.5-3 sec closing 100% duty cycle with push button
Loop sensor with communication model &SMPS(entry &exit location ) - 2 each at entry and exit
Parking Access Reader on the boom barrier
Parking access controller with enclosure &Accessories
4 Digit Led Matrix display at main gate H type mounting from ground
Parking counting controller with supporting accessories
Electronic Ticketing Machine - Entry and Exit with barcode reading facility
SIM Card - Entry and Exit
PC with Parking Management Software, API and connectivity
Installation and commissioning
ABD Projects - Ponnara Sreedhar Park
2 MP IR Speed Dome PTZ Camera
2 MP IR Bullet Camera
NVR: 4Ch Embedded Network Video Recorder
PoE Switch 8 Port
Media Convertor with Two Lan Port
SC/LC patch cord 1 mtr
6 TB Hard Disk
CAT 6 Outdoor
4U Rack
Pole With mounting bracket
20mm PVC Pipe / capping & casing
Installation and commissioning including fibre termination
ABD Projects - Putharikandam
2 MP IR Speed Dome PTZ Camera
2 MP IR Bullet Camera
NVR: 8 IP Cameras input
PoE Switch 8 Port
Media Convertor with Two Lan Port
SC/LC patch card 1 mtr
6 TB Hard Disk
CAT 6 UTP Cable
2U Rack
Pole With mounting bracket
20mm PVC Pipe / capping & casing
Installation and commissioning
Outdoor Display P4 Brightness>6000 (Full color) with MS Powder coated cabinet 1280X960.
Dual Mode Media Player with Live Playback Feature
Installation on site. (Excl. Fabrication)
GSM ECB Mother Board
GSM Antenna
Speaker
Solar Panel
Solar Charge Controller
Solar Panel Removed Sensor (Magnetic Switch Contact a Sensor)
Battery
MS Pole with Water Proof Cabinet, With Lock & Key
Installation and commissioning
CIVIL INTERIOR - MASONRY WORK
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core panels made of core material of EPS granule balls/beads (conforming to IS 4671:1984 and shall have density not less than 15kg per cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium silicate board confirming to EN 14306:2009 of 5mm thick each. Panel shall be laid on 6mm thick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall be preferably fixed into 'C' channel made of 1.2mm thick MS plate screwed/fastenened to the slab/column/beam etc. The panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except "C channel" which will be paid separately).Non load bearing panels 115mm thick of required size
Providing and fixing wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed with 50mm thick Rockwool as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on the G.I. Base plate of size 100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5mm welded with GI fully threaded stud 16 mm outer diameter with two GI check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Guages: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 Kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50 kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.300 mm Finished Floor Height (FFH).
Providing and fixing Dadoing walls with vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours, shades of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing Dadoing walls with Natural stone in different sizes (thickness to be specified by the manufacturer),of approved make, in all colours, shades of any size as approved by Engineer in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete as per the drawing.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and fixing Nylon Carpet on floor and skirting of approved design, size, shade, quality, make and a pile height of minimum 7mm with a total height of 9mm. The rate includes all necessary fittings , labour etc. complete as per the direction of Engineer in Charge.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
Providing and fixing removable Raised/metallic perforated false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:<br>a) Providing at required spacing to form modular framework, pedestals made out of All steel constructions & yellow Zinc plated 22 mm outer diameter, fully welded on the G.I. Base plate of size 100mmx100mmx2mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3mm welded with GI fully threaded stud 16 mm outer diameter with two GI check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.<br>b) Stringers system in all steel construction hot dipped galvanized of rectangular size 573x21x32x0.80 mm thick having two holes centre to centre 550mm for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.<br>c) Providing and fixing Access Floor panel of 600x600x35 mm medium grade Filled Steel anti-static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Guages: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. Top covering with high pressure antistatic hot pressed Laminates , factory finish in universal white color with grey streamlet pattern. Edge bonded with black conductive PVC beading. The panel is to withstand a Concentrated Load of 360 Kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1600 kg/sqm and an impact load of 50 kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.450 mm Finished Floor Height (FFH).
FINISHING
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.12 mm thick
Providing and fixing 2nd class teak wood plain lining tongued and grooved, the gap between wall and plain lining filled with rockwool of 100 mm thick including wooden plugs complete with necessary screws and priming coat on unexposed surface etc complete as per the direction of Engineer in Charge.
Melamine polishing on wood work ( one or more coat)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
JOINERY WORKS
Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge.using Anjili/ Jack wood
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm)made of (big series)frame 67 x 60 mm & sash 67 x 80 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead ofappropriate dimension. (Area of window above 0.75 sqm.)
Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead ofappropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazingbead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 Upto 10 mm depth and 10 mm width
Providing & fixing 19 mm thick BWP grade ply confirming to IS- 710 for Kitchen cupboards/Shelves of size as per drawings, the door shutters also shall be made with 19mm thick BWR ply fixed with auto close cabinet hinges hinges fixed over vertical ply.Outside vertical exposed surfaces of counter finished and Inside exposed surfaces finished with 1mm thick hot pressed laminate. ( only face area to be measured) etc complete, as per the direction of Engineer in Charge
Providing and fixing Premium quality SS 304 grade H type door handle of approved brand and manufacture approved by the Engineer in charge, having 450mm height, 32mm diameter etc. complete as per the drawing and direction of Engineer in charge.
Providing and fixing Premium quality SS 304 grade D type door handle of approved brand and manufacture approved by the Engineer in charge, having 300mm height, 22mm diameter etc. complete as per the drawing and direction of Engineer in charge.
Providing and fixing glazing in aluminium/UPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
Providing and fixing Premium quality Glass connector Patches of approved brand and manufacture approved by the Engineer in charge, etc. complete as per the drawing and direction of Engineer in charge.
Providing and fixing Premium quality Single Patches (Central Connector / Corner connector) of approved brand and manufacture approved by the Engineer in charge, etc. complete as per the drawing and direction of Engineer in charge.
Providing and fixing Premium quality Corner lock with EPC and strike plate of approved brand and manufacture approved by the Engineer in charge, etc. complete as per the drawing and direction of Engineer in charge.
Providing and fixing 12 mm thick toughened glass as partition of approved brand and manufacture, including providing and fixing top & bottom patch , all type fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-incharge (All type patches to be paid separately).
ROOFING WORKS
Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately)
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
MISCELLANEOUS
Art work installation on wall with Acrylic Paint, background surface-Initial Sketch and Good quality acrylic paint (water proof) applied on top of it with multiple layers to produce the desired image including all rates etc, complete as per the direction of Engineer in Charge.
Supply and installation of Acrylic LED letters/symbol 20cm height 18mm thickness and required colour as per design fixed on the wall. All rates are including making, labours, transportation, electrical works etc complete as per the direction of Engineer-in-charge.
Supply and installation of Acrylic LED letters/symbol 12cm height 12mm thickness and required Colour as per design fixed on the wall, . All rates are including making, labours, transportation, electrical works etc complete as per the direction of Engineer-in-charge.
Supply and Installation of Classic vinyl Blackout roller shades,pleather blackout roll-down shade,colour grey/beige blinds, should cover window completely, include all the necessary mounting accessories to complete, etc. as per the drawing and direction of Engineer in charge
FIRE FIGHTING WORKS
Supplying, installation, testing and commissioning of electrically driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS- 325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts tc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 450lpm @ 25m head.
Supply,installation,testing and commissioning of motor starter control panel (Auto/Manual) DOL starter unit & On Off,indication lamps etc. complete with all accessories including instrumentation as required
Poviding and fixing of Pressure switch in MS pipe including connection etc as required.
Supply & installation of Glycerin filled Pressure Gauge with 0-200 psi range, 3/8' BSP bottom entry 100 MM dial weather proof with SS internals and isolation cock.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers,gaskets conforming to IS 13095 of following sizes as required: 100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers,gaskets conforming to IS 13095 of following sizes as required: 80mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 MM
Supply, installation, testing and commissioning of Air Release Valve Gun metal body Horizontal Lift Type Having Screwed ends as per ISO Mark of following size as required. 25 mm dia
Supply, installation, testing and commissioning of stainless steel Ball Valves with necessary fittings confirming IS0 17292 of following sizes as required. 25 mm dia
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories Pendent Sprinkler Bulb
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS-5290 (Type -A) with blank Gunmetal cap and chain as required
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve & nozzle.c) Drum and brackets for fixing the equipmets on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S.Pipe and socket.
Supplying and fixing 63 mm dia 15 mtr long CP hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc conforming to IS 636 (type-A) as required
Supply & installation of Hose Cabinets to accommodate two piece of hose pipe along with two pair of male and female coupling and one branch pipe. The double door cabinet is made up of FRP sheet with glass fronted hinged doors and lock, painted with Post Office red colour.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way
Supply and installation of dry chemical powder type ABC 5Kg Stored Pressure Fire Extinguisher complete with initial charges, discharge hose, wall mounting brackets etc. and with ISI mark
Supply and installation of suspended Clean Agent type Fire extinguisher filled with HFC 227ea with approved make. 5Kg capacity
Supply, installation and commissioning of 1 Loop Micro processor based 2 wire fault tolerant loop. Loop shall have the cpability of connecting 126 devices.The panel should have inbuilt TCP/IP communication for Panel Program and Modbus TCP/IP comminucation to integrate with BMS. The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display, and analog output.The Panel Should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode.The panel shall have a built in power supply and battery charger along with maintenance free 7 AH,x 2 nos 12 volt SMF Lead acid batteries battery charger complete as requiredand as per specifications and Duly Approved by EN54 or UL
Supply and installation of Intelligent Analog Addressable type Smoke Detector with inbuilt turbo Isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40 and Duly Approved by EN54 or UL
Supply and installation of addressable Manual call point. The Manual call points shall be resettable type with flexi element and shall include a test key feature for the rapid testing of the device without removing the glass. The call point shall also incorporate an alarm response indicator, IP54 protection and duly approved by EN54 or UL Make : Honeywell/Siemens/Cooper or Equivalent
Supply and Installation of addressable Input Monitor modules with supervisory input contact to integrate 3rd party equipment alarms to FACP
Supply and Installation of addressable Output control relay modules with supervisory NO and NC contact to trigger 3rd party equipments.
Supply and installation of Intelligent Analog Addressable type Heat Detector with inbuilt turbo Isolator and integral response indicator with 360 degree viewing angle. Detector shall be able to detect static as well as differential temperatures. Detector should have unquie address for communication and assigned through panel with Mounting Base as required with the protection category of IP40 and Duly Approved by EN54 or UL
Supply, drawing, testing and commissioning of 2Cx1.5 Sq MM Red coloured PVC sheathed fire-rated, armoured Copper conductor cables are laying Surface/recessed in the wall and ceiling with ISI mark.
Supply and fixing of response indicator
Supply and fixing in position photo luminescent type signages with indication arrows and letters for Fire hose/Fire Fighting Equipment /Fire Extinguisher.(Make:PROLITE / CEASEFIRE)
Supply and fixing in position exit signages photoluminscent type with indication arrows and letters EXIT / FIRE EXIT. (Make:PROLITE / CEASEFIRE)
Supply and installation of LED Exit / Egress Edgelit lights with a rechargeable battery, conform to IS 9457 :2005, 22 SWG CRCA white powder-coated housing having input voltage of 230V 50Hz in the proposed locations and giving connections as required.MAKE :PROLITE / CEASEFIRE
Supply and installation of Slave Cylinder assembly Comprising Below Items: Pr. Guage + Low, Pr. Supervisory Switch, Pneumatic Actuator, Flexible Discharge Hose, Flexible Actuation Hose + 1, Tee + 1, Elbow 7/16 ,JIC - 1/8 NPT,
Supply and installation of Master Cylinder assembly Comprising Below Items:Pressure Gauge + Low Pressure, Supervisory Switch,Electromagnetic Actuator,Pneumatic Actuator,Flexible Discharge Hose,Flexible Actuation Hose Manual & Pneumatic Actuator,Union 7/16 JIC 1/8
Supply and installation of Discharge Monitoring Pressure Switch having NO/NC contact to monitor
Supply and installation of Check Valve and which be compatible with cylinder system
Supply, filling and storage of Novec 1230 extinguishing agent in a seamless cylinder as per NFPA standards . The system shall utilise 42 bar pressure technology.
Supply and installation of Manual abort Switch with flip cover or shall be protected against unwanted activation
Supply and installation of Manual Release Switch with flip cover or shall be protected against unwanted activation
Supply and installation of Nozzles. Nozzle size and type shall be decided as per manufacturer calculation
Supply and installation of microprocessor controlled 2 Zone Gas Release Panel. Panel shall have minimum 1 nos agent release circuit and feature to prevent accidental release. Panel shall have builtin battery charger and shall include 2 nos 12V7AH battery. Panel shall be complied with CE
Supply and installation of M.S. ASTM A 106 Gr. B. Sch. 40 Seamless pipe network for extinguishing agent flow with all fittings, supports as per OEM design plan and finished with fire red paint followed by one coat of primer, in server room and main operator room
Supply and installation of seamless 120 Ltrs. Cylinder with Valve and all fittings required for the NFPA standard installation
Supply and installation of seamless 100 Ltrs. Cylinder with Valve and all fittings required for the NFPA standard installation
HVAC WORKS
Supply,installation,testing and commissioning of factory assembled Modular type VRF out door units equipped with high efficiency DC inverter scroll compressor low noise variable speed condenser fans, Anticorrosion treatment standard on exterior metal parts, heat exhanger , operating on R 410 A refrigerant and factory wired micro-processor based control centre with auto check function for connection error, auto address setting etc.and saftey devices like vibrator isolator pad, thermal protector, over load relays, single phase preventor, over voltage / low voltage / short circuit protection.The system shall be suitable for operation upto 45°C ambient without tripping or failure. Power supply - 400 V / 3ph/ 50 Hz and erecting suitable structure made up of MS suitable cross section neatly painted with one coat of anti corrosive paint as primer and two coats of epoxy paint of approved colour with placing vibration isolators of ribbed rubber pads.20 HP OUTDOOR
Supply of VRF Indoor units complete with electronic expansion valve , multi-row deep high efficiency cooling coil ,low noise single/twin speed fan - statically and dynamically balanced, washable type synthetic media filter, insulated drain pan with drain pump.The unit shall be provided with drain pump and saftey devices like over load relays,single phase preventor, over voltage / low voltage / short circuit protection.2.0 Tr Hi Wall .
Supply of VRF Indoor units complete with electronic expansion valve , multi-row deep high efficiency cooling coil ,low noise single/twin speed fan - statically and dynamically balanced, washable type synthetic media filter, insulated drain pan with drain pump.The unit shall be provided with drain pump and saftey devices like over load relays,single phase preventor, over voltage / low voltage / short circuit protection.1.5 Tr Hi-wall Split Unit.
Supply of VRF Indoor units complete with electronic expansion valve , multi-row deep high efficiency cooling coil ,low noise single/twin speed fan - statically and dynamically balanced, washable type synthetic media filter, insulated drain pan with drain pump.The unit shall be provided with drain pump and saftey devices like over load relays,single phase preventor, over voltage / low voltage / short circuit protection.1.3 Tr Hi-wall Split Unit.
Supply of VRF Indoor units complete with electronic expansion valve , multi-row deep high efficiency cooling coil ,low noise single/twin speed fan - statically and dynamically balanced, washable type synthetic media filter, insulated drain pan with drain pump.The unit shall be provided with drain pump and saftey devices like over load relays,single phase preventor, over voltage / low voltage / short circuit protection.8.2 Tr Ceiling Suspended Ductable Unit.
Supply of VRF Indoor units complete with electronic expansion valve , multi-row deep high efficiency cooling coil ,low noise single/twin speed fan - statically and dynamically balanced, washable type synthetic media filter, insulated drain pan with drain pump.The unit shall be provided with drain pump and saftey devices like over load relays,single phase preventor, over voltage / low voltage / short circuit protection.6.36 Tr Ceiling Suspended Ductable Unit.MAKE: Daikin/Mitsubishi/Carrier or Approved Equivalent make
Supply and Installation of Modbus Adaptor for Two nos. Outdoor and Two ductable indoors .Supply,installation,testing and commisioning of modbus adapter with BMS protocol and BMS compatible with suitable sofware and accessories. Necessary integrators,convertor,hardware,license's etc as appicable for the following VRF system to interact and be controlled by central BMS system, suitable control cabling shall also be included MAKE : Daikin/Mitsubishi/Carrier or Approved Equivalent make
Supply of Cordless Remote Hand set for Hi-wall
Supply and Installation of corded controller for ductable units.
Supply,installation and testing of imported refrigerant joint / Branch distibutors in copper piping for units as recommended by the manufacturer/consultant, complete with nitrile rubber insulation, supports etc as required.
Unloading, Positioning, Installation, testing and commisioning of HVAC units of following types complete with all necessary accessories as required, with R-410A gas after necessary pressure testing, vaccumising, intial charging and handing over of air conditioning system after necessary air balancing Ductable Unit
Unloading, Positioning, Installation, testing and commisioning of HVAC units of following types complete with all necessary accessories as required, with R-410A gas after necessary pressure testing, vaccumising, intial charging and handing over of air conditioning system after necessary air balancing Hi-wall Split Unit
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required. 6.35 mm with 13 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.9.5 mm with 13 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.12.7 mm with 13 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.15.9 mm with 13 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.19.1 mm with 19 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.22.2 mm with 19 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.28.6 mm with 19 mm thick insulation
Supply,Installation of hard drawn insulated copper tubes nitrile rubber for both liquid and gas line with copper pipes for connection between ODU and IDU as per manufacturer recommendations, neatly clamped on wall protected or concealed on wall including cutting the wall, making good the damages and colour washing etc. as required.31.3 mm with 19 mm thick insulation
Supply, installation, testing and commissioning of factory fabricated GSS Rectangular ducting of grade 120 GSM confirming to latest IS-655 & 277 of following sizes as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, Volume control damper as per design drawing,inspection doors, transformation pieces, slip on flange etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specification or as recommended by consultant.24 G
Supply, installation, testing and commissioning of factory fabricated GSS Rectangular ducting of grade 120 GSM confirming to latest IS-655 & 277 of following sizes as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, Volume control damper as per design drawing,inspection doors, transformation pieces, slip on flange etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as reqd. and as per specification or as recommended by consultant. 22 G
Supply, laying and giving connections by using manufacturer recommended copper cable in medium duty electrical graded PVC, FRLS conduits of minimum 25mm dia, neatly clampled, complete with all necessary accessories as required for the electrical interconnections between indoor and outdoor units.
Supply and fixing in position of condensate drain water & indoor unit drain to the floor trap piping with 6 mm thick nitrile rubber insulation and with necessary fittings like elbows, tees and reducers etc. 25 mm dia PVC
Supply and fixing in position of condensate drain water & indoor unit drain to the floor trap piping with 6 mm thick nitrile rubber insulation and with necessary fittings like elbows, tees and reducers etc. 32 mm dia PVC
Supply & fixing of 9 mm thick Class"O" nitrile rubber thermal insulation with density 45-55kg/m3, with adhesive as per the recommendation of the manufacturer
Supply and fixing of acoustic insulation with density 140-180kg/m3 on plenum and intial portion of the duct from the Indoor units mouth with open cell type of following thick nitrile sheet and manufacturer recommended adhesive and tightened with necessary accessories etc. as required.
Supply and installation of Fresh air intake louvers made of extruded aluminium with bird/insect screen provided with intake louvers. The lowest louvers of the assembly shall extend out slightly to facilitate disposel of rain water without falling on the door/wall on which it is mounted and complete with all aluminium made volume control dampers.
Supply, installation, testing and commissioning of Gl volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. Gl volume control duct damper
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supply and Installation of factory made flexible connectors made of fire rated canvas cloth for connetions between IDU and sheet metal duct.
Supply and Installation of factory made flexible connectors made of fire rated canvas cloth for ventilation fan.
Supply and fixing of toilet exhaust disc valve . 150 mm dia
Supply, commissioning and installation Inline Exhaust Fan for Toilet with all necessary fittings. 350 CFM
Supply, commissioning and installation Inline Exhaust Fan for Toilet with all necessary fittings.100 CFM
ELECTRICAL WORKS
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required . 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required .2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required . 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required .8 way (8+24) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required . 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required . 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5 core 185 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 70 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 185 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 35 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 70 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 4 X 35 sq. mm
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed I XLPE copper conductor cable of 1.1 kV grade as required. 4 X 70 sq. mm
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run). 25 x 3 mm copper strip
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(450 mm width X 62.5 mm depth X 2.0 mm thickness)
Supply and installation of 4ft LED linear battern should have specially designed extruded aluminium housing , lumen output greater than 1900 lm and maximum system wattage of 20W including separate CC APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 90 lumen/watt and including all necessary accessories as required complete.
Supply and installation of 2ft LED linear battern should have specially designed polcarbonate housing , lumen output greater than 950 lm and maximum system wattage of 10W including separate CC APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 95 lumen/watt and including all necessary accessories as required complete.
Supply and installation of pendent mounted high efficient LED downlighter, with housing made up of diecast aluminium and white powder coated finish, HET diffuser for better light transmission, CRI>80, LED efficacy>100lm/W,Color temperature-5700K, IP20, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>80%, THD<10%, Powerfactor>0.9, Surge protection in CM-2KV, Multistage Isolated Constant Current- Constant Voltage Operated driver with range 150-270V AC , Wattage ≤ 15W, system lumen output should be>1500 LED shoul bin as per ANSI Bin C78.377A standard. LM80,LM79 and photo biological tast of the luminaire should be produced.
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and maximum system wattage of 6W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and lumen output greater than 1600 lumen with maximum system wattage of 18W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and lumen output greater than 1400 lumen with maximum system wattage of 15W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
Supply and installation of LED Recessed Mounted downlighter should have Constructed in die cast aluminum Powder Coated White housing and Lumen output greater than 800 lumen with maximum system wattage of 9W with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 20%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
Supply and installation of LED recess Mounted downlighter should have white powder coated pressure die cast aluminium housing and PMMA LGP diffuser , lumen output greater than 350 lm and maximum system wattage of 6W including separate CC,CV APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 20%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete
Supply and installation of LED Track Light with aluminium die cast construction with white powder coating clear galss diffuser of 1 mm thick high efficiency reflector optics should be suitable for integral track adaptor with special track locking system to ensure proper mounting on track. lumen output greater than 2000 lm and maximum system wattage of 20W including separate CC, APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 80. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 85 lumen/watt and including all necessary accessories as required complete.
Supply and installation of LED suspended downlighter should have white powder coated pressure die cast aluminium housing and bottom frame , lumen output greater than 1000 lm and maximum system wattage of 10W including separate CC,CV APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete.
Supply and Installation of LED Recessed Mounted IP65 or higher Step light Constructed in die cast aluminum Powder Coated housing with poly carbonate clear diffucsr and maximum system wattage of 7W . LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 3000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. constant current topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85 %. LED tube should have THD < 20%, power factor > 0.9, system efficacy of lamp greater than 50 lumen/watt and including all necessary accessories as required complete
Supply and installation of IP65 rated LED Bulkhead fitting with aluminium diecast housing with powder coated ,Polycarbonate opal diffuser,High quality silicon gasket for IP65 Protection,Ambient temp-0 to 45 DegC,LED with 50000 burning hours as per L70 Criteria, CRI>70, color temperature- 5700K, , Complete assembly with LED, Driver and accessories pre wired up to terminal block Driver With efficiency>85%, THD<10%, Power factor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. 10W LED Bulkhead luminaire delivering > 720lm.
Supply, Installation , testing and commissioning of 10W LED integral Updownlight light with not less than 670 lumens and CCT of 3000k CRI>80, IP65 with aluminium housing with anthracite color suitable for aesthetics with PF> 0.9 & longer life. Similar to Philips make "31450 Propulsio" or equivalent in approved make list
Supply installation testing and commissioning of Compact substation having 11 / 0.433kV, 250 KVA CRT Dry type, three phase, 50Hz, Dyn11,outdoor type, copper wound transformer with off circuit tappings from +5% to -10% in steps of 2.5%, changeable on off circuit by tap links provided, 3 Nos CTs, 1 No PT, provision for fixing TOD Meter and output connected to 11KV seal off bushings to the transformer as per IS2026- factory assembled, factory tested ready to install and connections type Compact substation complete with an outdoor enclosure having 11 KV VCB at HT side, CRT dry type distribution transformer and Low Voltage Switchgear according to requirement; complete with HT cable interconnection done in between transformer and VCB and suitable sized busbar between transformer and LV incoming main switchgear-MCCB (having isolation duty) of suitable rating according to full load output current of the transformer, all as a single transport unit. The CSS must be compatible with mode bus communication protocol for Building management system.
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support,front operated type tested panel board made out of 2 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3 mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.The cable entry should be Top/Bottom entry type according to the site condition.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall confirm IEC 61439-1&2 / IS 8623 – 1 standards. The panel must be compatible with Mode bus communication protocol for BMS. Similar to Siemens SIEPAN 8PULV or equivalent in approved makelist.INCOMER: 400A,35KA, 4P MCCB with E/F - 2nos,400A 4P CONTACTOR- 2 no,AMF relay with interlock- 1 no,51G relay- 1 no, OUTGOINGS:125A ,25KA, TP, MCCB - 3 nos,200A , 25KA, TP, MCCB - 3 nos,315A ,25KA,TP,MCCB - 1 nos
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support,front operated panel board made out of 2mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.The cable entry shall be Top entry type.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall be of form 4 type separation.The board shall confirm IS 8623 standards.The panel must be compatible with Mode bus communication protocol for BMS. INCOMER: 100A TPN Isolator - 1 no, OUTGOINGS: 63A ,25KA,TP MCCB - 4 nos, 40A ,25KA,TP MCCB - 1 no
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support,front operated panel board made out of 2 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3 mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required.The cable entry shall be of Top entry type.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall be of form 4 type separation.The board shall confirm IS 8623 standards.The panel must be compatible with mode bus communication protocol for BMS.INCOMER:125A TPN Isolator - 1 no, OUTGOINGS: 63A ,10KA,TP MCB - 4 nos, 40A ,10KA,TP MCB - 1 nos,25A ,10KA,TP MCB - 1 no
Supply , installation testing and commissioning of Cubicle type dust and vermin proof, floor mounted with ISMB channel support ,front operated panel board made out of 2 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 3 mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections and interconnected with suitable AL Bus bar.Cable Chamber shall be provided for incoming & outgoing cables or as required. The cable entry shall be Top entry type.Earth bus shall be full length of the panel and all Switches/breakers shall be double earthed.The board shall be of form 4 type separation.The board shall confirm IS 8623 standards.The panel must be compatible with mode bus communication protocol for BMS.INCOMER: 200A FP MCCB - 1 no ,OUTGOINGS: 125A ,25KA,TP MCCB - 2 nos, 100A ,25KA,TP MCCB - 2 nos
Supply , installation testing and commissioning of of 150 KVAr APFC panel with block reactors.The panel must be cubicle type dust and vermin proof, floor mounted,front operated panel board made out of 16 SWG / 1.6 mm thick CRCA sheet duely rust inhibited,zinc passivated, phosphated and powder coated after 7 tank process with approved colour,fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets removable gland plates made out of 2mm thick sheet steel with all necessary meters, indications, CTs etc as shown in the electrical drawing or as per the latest Electrical Inspectorate requirement complete with all connections .The voltage rating of the Power Factor correction requirement shall be at 440 Volts between phases.Permissible over rating shall be 1.5 In, 1.5Vn, 1.2fn as per IS.The total KVAR shall be divided into automatically switched steps of suitable rating.By using Microprocessor based VAR controller which will be able to sense the reactive current requirement and switch on the required VAR providing intelligent switching based on actual value of KVAR and Bank size.The no. of switching stages shall be designed appropriately in steps of 25*5,15*1 & 10*1 for 150 KVAr. The capacitor stages will be switched in rotation to equalise working hours. Individual Capacitors shall be of 3 phase construction in design using Heavy Duty Polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes.Dielectric material shall be low loss, less than 0.3 watts per KVAr. The controller should be fully automatic, intelligent microprocessor based relay operated offering minimum 8 stage.All live parts are segregated and shrouded ( busbars, Inter‐Connecting copper forms and terminals ) as per National Electricity Code.For forced ventilation fans must be provided.
Supply installation testing and commissioning of 250 KVA, Diesel Generating Set with CPCBII approved acoustic enclosure comprising of radiator Cooled Diesel engine 1500 RPM, complete with standard accessories. Coupled to alternator with rated at 250 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Manual Control System with Fuel Tank ,Batteries and battery charger. The generator control panel with necessary breakers, ammeters, voltmeter,energy meter,relays,and other accessories as per the Electrical inspectorate standards must be provided. The DG set msut be compatible with mod bus communication protocol for BMS.
Supply & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Terrace Conductor Fibre Reinforce Concrete Holder @ every 1 meters
Supply & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Parapet Holder made of weather resistant plastic @ every 0.4 meters
Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3mm solid tape can also be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns tape can also be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.
Supply installation testing and commissioning of Passenger lift having a capacity of 13 passengers, minimum rated load of 884 kg. The minimum net inside car area is 2.06sq.m and maximum net inside car area should be 2.20 sq.m . The lift must have a minimum speed of 1.5 mps and 2 stops. The lift car must be of anti- vandal SS finishes, SS 304/better life grade steel shall be used for all steel parts like Handrail, Landing (Faceplate, Frame, Buttons). The Interior shall be with Half size mirror, beige interior shades or similar shade as approved, Granite flooring with approved shade, Braille enabled on push buttons with LCD display inside Car panels and White Dot Matrix / equivalent in landing panels.The lift must have the standard features like anti nuisance car call protection, over load device, emergency car light unit, emergency alarm button, infrared curtain door protection,door time protection,automatic operation for car fan, Provision for music system wiring (in travelling cable) Voice announcement unit, Overload function with audio-visual indication in car operating panel, Fire man switch with Fireman operation,car call cancellation by double pressing floor button in car operating panel,full door Infra-red screen for car door. The lift must have potential free Building Monitoring System (BMS) contacts / RS485. The lift and its installation shall conform to relevant IS standards.
Supply and fixing Fully Solid Vertical Air terminals as per IS/IEC -62305 part-3,16mm rod tapered to 10 mm aluminium rod meter rod Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform.Stainless Steel Wall Clamp/16 KG stone of 365 mm diameter, high level of stability. No of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked. Govt approved Indian labs test certificate required. 2 meter air terminal with necessary mounting accessories Similar to Cape or equivalent in approved make list.
BUILDING MANAGEMENT SYSTEM
Supply, installation, testing and commisioning of integrated Building Management system comprising of BMS PC with min. 1 GB Ethernet Network Interface card Building Management System Monitoring & controlling DDCs, Third party integration equipments as mentioned in the I-O list with required software & hardware interfaces Rodent repellent system Water leakage detection system Refer BMS SLD and I/O summary for details
Fiber cabling charges from nearest Police dark fiber to end locations ( including road cutting / refilling /fiber cable supply / laying termination etc as required for site) - biider need to quote for Per Mtr charges
Training and handholding Charges
Recurring Charges for ICCC Project
LoRA connectivity recurring charges for 10123 devices for 60 months - bidders need to quote per month charges per device
Recurring charges SIMs for LoRA Gateways for 5 years
SIM recurring charges for GPRS devices in 500 bus for 60 months
Network bandwidth charges for connecting the field devices in KSRTC bus stops and depots to ICCC platform (from remote bus shelters, depots and other locations- 59 locations) for 60 months
SIM Recurring charges for Mobile devices 100 numbers for 60 months
Network bandwidth charges for connecting the field devices in camera locations (48 locations) to ICCC platform for 60 months
Network bandwidth charges for connecting the Environment Sensors (5 locations) to ICCC platform for 60 months
Bandwidth Charges in ICCC DC location
DC Internet Bandwidth 60 Months- 1Gbps
ICCC DC - DR Bandwidth- 20 Mbps for 60 months
ICCC DC –ITMS Center 50 Mbps Aggregate Bandwidth- this can be leased line /dark fiber or dedicated fiber cable laying between these two locations (around 5 Km distance)
DR Hosted Model charges
One time setup charge for DR facility
DR Monthly hosting charges – Include necessary servers, software , Storage , Backup solution, Network connectivity and bandwidth requirement as required for the DC-DR application level replication.
Man Month Charges : Man month rate for additional software development (bidders need to quote for per man month rate). These rates will be considered, if there is a change request , additional scope arises during the project period.
Support Manpower charges for O&M Period
Providing call centre agents (CC Manpower) – 5 Nos (3 in general shift, one in second shift and one in night shift) for 60 Months
Providing ICCC Manager for 60 Months – 1No
Providing ICCC Support Engineers 5 Nos for 60 Months
Operations & Maintenance Charges for all equipments and Software provided under ICCC Project scope for 5 years
Operation & Maintenance charges for 1st Year after Go Live
Operation & Maintenance charges for 2nd Year after Go Live
Operation & Maintenance charges for 3rd Year after Go Live
Operation & Maintenance charges for 4th Year after Go Live
Operation & Maintenance charges for 5th Year after Go Live
Orange Business Services
NEC Technologies India Pvt. Ltd
Keltron Communication Complex
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid