Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.7 LAccepted-AOC MORKANDA ROAD BALNATH NURANI TOWER 2ND FLOOR BLOCK NO 301 JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹10.2 L+₹22,890.80 (2.29%)Rejected-Finance | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹10.3 L+₹28,507 (2.85%)Rejected-Finance | 3 | Rejected-Finance NOT L1 | |
| 4 | 4₹10.6 L+₹60,787.66 (6.09%)Rejected-Finance | 4 | Rejected-Finance NOT L1 | |
| 5 | 5₹11.7 L+₹1.7 L (16.9%)Rejected-Finance | 5 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹18,260
Closing Date
5 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
PROVISION OF SANCTION WORK REV 5 , MW 11 AND 12 AT MIL STN JAMNAGAR
2021_MES_441284_1
8804
Open Tender
Civil Works
Item Wise
120 days
Jamnagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
₹18,260
26 Jun 2021
8 May 2021
7 Jun 2021
14 May 2021
5 Jun 2021
14 May 2021
60 days
Amount
JNR/MW/11/ Provision of cycle and scooter parking shed at main gate of 152 AD Regt at Jamnagar Mil Stn.
Demolition of Concrete of any description and in any position not otherwise specifically provided for cement concrete reinforcement complete as specified and directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard /densed soil complete as specified and directed by Engr-in-Charge.
M/L for PCC 1;3;6 type C-2 ( using 40mm graded stone aggregates) as in foundation filling and mass concrete complete as specified and directed by Engr-in-Charge.
S & F Structural steel/ tubular /box section including special shaped washer etc. complete using ERW or induction butt welded tubes all around conforming to I. S.1161-1979 .St.240 conforming to Fe 410-0 or Fe 310-0 complete as specified and directed by Engr-in-Charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed by Engr-in-Charge.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surfaces exc 10 cm in width or girth and applying 2 coats synthetic enamel paint over a coat of Red oxide complete as specified and directed by Engr-in-Charge.
JNR/MW/12/ 2020-21:- Provn of Soft Water Plant for precesion Air Conditioner at composite Node of project NFS at Infantry lines Jamnagar
Supply and installation of soft water plant for precesion air conditioner at access node of project NFS. A water softerner collects hardness minerals within its conditioning tank and from time to time flushes them away to drain ION exchangers, used for water softening replace the calcium and magnesium ion in the water with other ions, such as sodium or potassium. The exchanger ions are added to the ion exchnager reservoir as sodium and potasium salts (Nacl & KCL). Specification:- 1. Output /Regeneration (m³/h) based on feed water hardness 200PPM Caco3 purple resin qty (ltrs) ZR NaF- 11 @ <50PPM Hardness 2. Purple resin quantity (Ltrs) ZR NaF-45. Coarse Silex (Kg) - 58.3 3. Cabinet Salt Capacity in Kgs -200 in special case. 4. Salt per recharge in Kgs-7. 5. Vessel size- 13" dia X 54" Height , 4" Top opening. Auto Softener AS -03 Make- Aqualeo Electricals or Equivalent (Note:- AMC for 3 year & 3 visit per Year)
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position complete as specified and directed by Engr-in-Charge.
S&F High density polyethylene pipes (HDPE) 20 mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. all as specified and directed.
M&L for Cutting existing steel tubing dia 25/32mm for alterations or additions (Each cut measured) complete as specified and directed by Engr-in-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends 20mm dia for iron pipe and fixed complete as specified and directed by Engr-in-Charge.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, terminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :- (Make : Havells/Finolex/Polycab) (a) One 5 Amps switch socket combination on independent board.
S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose complete as specified and directed by Engr-in-Charge.
Excavation in post holes (or similar holes) each n. exc 0.5 cu. M getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc 50 m and making good surface complete as specified and directed by Engr-in-Charge.
M & L PPC (1:4:8) Type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete as specified and directed by Engr-in-Charge.
M & L PCC (1:2:4) Type B1 using 20 mm graded stone aggregate foundation, including raft, footings,foundation beams, plinth beams; bases for columns, etc.; basement slabs,under reamed piles and mass concrete complete as specified and directed by Engr-in-Charge.
S & rolled section as in main and cross beams ,hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of grade FE-410 (W (Gde -E-250) Quality B complete all as specified and directed.
Pre-painted galvatume aluminum zinc coating Gl based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with 'L' type hooks with provision of bitumin washer complete all as specified and directed
M&L hard core with broken stone or boulders of auge n.exc 63 mm deposited spread & levelled in layers n.exc 15 cm thick water & rammed true surface complete as specified and directed by Engr-in-Charge.
M&L P.C.C 1:3:6 type C-2 75 mm thick as in sub base complete as specified and directed by Engr-in-Charge.
M&L PCC 1:2:4 type B1 using 20 mm graded 40 mm thick as in floor finishing cement concrete surface even & smooth w/o using extra cement complete as specified and directed by Engr-in-Charge.
M&LGlass dividing strips 3 mm thick and 38 mm wide insert in position in floor complete as specified and directed by Engr-in-Charge.
Surface of any description,n exc 10 cm in width or girth, not otherwise described of two coats of synthetic enamel paint and a coat of red oxide, zinc chrome and new or previously untreated surfaces complete as specified and directed by Engr-in-Charge.
REV/05/ Provn of Chain Link fencing between Pillar No 46 to 47 at inf BN No III (9 Madras Travancore ) at inf lines Jamnagar.
Excavation in post holes (or similar holes) in hard/dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete as specified and directed by Engr-in-Charge.
S&F galvanised steel barbed wire 2 stand 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete as specified and directed by Engr-in-Charge.
S&F in Concertina Coil 900 mm dia with 50 loops 45 mm strip 2.5 mm wire blade length 22 mm and distsnce of about 35 mm ISI heavy coated 230-240 GSM zinc on wire TS 165kg/mm2 complete as specified and directed by Engr-in-Charge.
M&L PCC 1:3:6 nominal mix type C-2 (Using 40 mm grade aggregate) as in foundations, fillings for embedding chain link fencing complete as specified and directed by Engr-in-Charge.
S&F Mild steel works with angle iron, as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work confirming to Fe-290 Gde E-165 complete as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surfaces Surfaces of any description, not otherwise described,over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete as specified and directed by Engr-in-Charge.
badri glass and construction
VINUBHAI P. CHANDRA
Pooja Enterprise
motwani and associate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .