Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance D NO 11 57 2 BUILDING BARROMAMBA COLONY AGANAMPUDI GAJUWAKA VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530046 | VISAKHAPATANAM | ANDHRA PRADESH | 530046 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
2 Jun 2021, 4:00 pmClosed
MANAGER (CIVIL)
Hindustan Shipyard Ltd, Visakhapatnam
Renovation of Extended BDD Office location IT dept., in 1st Floor of Adminstrative Building.
2021_HSL_85838_1
OS/CM/001786/00006P
Open Tender
Civil Works
Works
30 days
Hindustan Shipyard Ltd
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
12 Jun 2021
30 Apr 2021
3 Jun 2021
30 Apr 2021
2 Jun 2021
30 Apr 2021
Amount
Part - A): Civil Works:
Removal of exisitng damaged wooden planks and same has handedover to Civil Dept., complete all as driected.
Removal of existing aluminium partition wall and relocate the partion wall to new location including any accessories / material required
Providing cabin with aluminium partitions / glasas
Providing 12 mm thick plaster with CM (1:6) to Walls etc.,at all heights including cost of all materials, tools, plant and labour, scaffolding arrangements and curing all as per specifications and directions of the engineer.
Applying two coats of putty of approved brands Birla / JK to internal wall surfaces, including applying suitable primer on old wall surface after thourough scrapping by mechanically and preparation. Putty shall be finished till a smooth and even surface is achieved complete all as directed.
Apply two coats of premium quality arcylic Interior emulsion paint over a one coat of primer, reqired shade to wall surfaces from approved brands Asian paints (Royal shine), Berger (silky luxury) where ever specified by Engineer including necessary scaffolding etc., complete all as directed.
Apply two coats of premium quality arcylic Interior emulsion paint, reqired shade to false ceiling boards surfaces from approved brands Asian paints (Royal shine), Berger (silky luxury) where ever specified by Engineer including necessary scaffolding etc., complete all as directed.
Supply and Fix the fabric vertical venetian blinds of approved make Jacobs / Vista including connected extruded aluminium head rails and all accesories etc., complete
Repairs to alluminium doors with necessary spares complete all as directed.
Refurbishment of existing door shutters including carryout the repair and fixing of teak venering on both faces etc., complete all as directed.
Repairs and refurbishment of existing wooden windows
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing PVC Vinyl Flooring at damaged areas complete all as directed. (Patch works only)
Cleaning of existing PVC vinyl flooring etc., with suitable chemicals or its equivalent material complete all as directed.
Providing two(2) coats of synthetic enamel paint for doors, windows and grills etc., (after removing the rust by using wire brush or sand paper if required) of approved brand (Asian / Berger / Nerolac) and manufacture of required colour to give an even shade on old work including applying putty and prime coat complete all as directed
Supply and providing suitable size GI sheet along the external wall and providing necessary grouting to arrest the rain water leakages to hall
Part - B): Electrical Works:
Supply, fix, test and commissioning of 3 phase, TPN 4way double door MCBDB with 63 Amps, 4 pole as main incomer and 10 A to 32 A, 10KA SP / TP MCBs as outgoings including all other fixing accessories as required and as directed. (Approved make Schneider/ Siemens/ ABB/ Havells or Equivalent.)
Supply, lay on wall/ground fix and connecting up of 4 X 35 Sq.mm PVC copper cable from Main Panel in Ground floor to incoming Panel (Approved make Universal/ Polycab/ Skytone/ Havells or Equivalent.)
Concealed PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for one point controlled by one switch as directed. Wiring on wood shall be concealed through Casing & Caping.
Concealed PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for two point controlled by one switch as directed. Wiring on wood shall be concealed through Casing & Caping.
Concealed PVC conduit wiring with 3 runs of 2.5 sq.mm FRLSH PVC flexible copper cable for switch sockets as directed. Wiring on wood shall be concealed through Casing & Caping.
Concealed PVC conduit wiring with 3 runs of 4.0 sq.mm FRLSH PVC flexible copper cable for AC units, Oven and Refrigerators. Wiring on wood shall be concealed through Casing & Caping.
Supply, fix, test & commissioning of 3 modular type switch board with 01no. 16A (3+2 pin) modular socket and switch.
Supply, fix, test & commissioning of 3 modular type switch board with 01no. 5A (3+2 pin) modular socket and switch.
Supply, fix, test & commissioning of 8 modular type switch board with 03nos. 3pin 5A modular socket with 2nos. switches for Main Supply as directed by engineer in-charge.
Supply, fix, test and commissioning of single phase, 240V, modular type switch boards with switches for controlling fans and lights and with combination switch cum sockets on each board
Supply, fix, test & commissioning of 4 modular type switch board with 04 nos. 5A modular switches as directed by engineer in-charge.
Supply, fix, test & Commissioning of 20A SP MCB DB with MCB for AC units as directed by engineer-incharge.
Supply, fix, test & commissioning of 1phase, 240V, 400 mm sweep wall mounted fan as directed by engineer in-charge.
Supply, fix, test & commissioning of 1phase, 240V, 400 mm sweep pedestal fan as directed by engineer in-charge.
Supply, fix, test & commissioning of 1phase, 240V, 50 Hz, 200 mm sweep plastic exhaust fan with self opening louvers
Supply, fix, test & commissioning of 12 Watt Surface mounted LED light fittings with all necessary accessories
Installation of HSL provided 1.5T/2T Split AC Units (indoor & Outdoor) including Core Cutting (RR Wall 500mm)
Supply and laying of copper pipe, drain pipe, foam etc. for Split AC units complete all as directed
Supply, fix, test and commissioning of LCd projection system (i.e., 3600 lm, 15000:1 Contrast ratios, 1024 X 768 resolution etc.,) including supply & fixing of 2 feet hanging stand and required cables with conduit piping (i.e., 7 Mtrs Power cable, 10 Mtrs VGA cable and 10 Mtrs HDMI cable) and including all civil works like making groove, plastering & matching paint. Cable runs on tiles shall be taped properly. Projector Make: EPSON EB X 41 or equivalent)
Supply and fixing of 8 (width) X 6 (height) feet, Manual operated, Wall Mount Projector Screen as approved by Engineer in charges
Removal of all existing wiring material, iterms, fittings, equipment etc., and handover to Maintenance Dept. of HSL
PART – C (LAN Connected Works):
UTP CAT 6 Cable
I/O Box full set
CAT 6 Information Outlets (Key stones) for unloaded jack panel
Patch Card (1 Mtr)
PVC 1" Conduit Pipes
Laying of UTP / STP Cable and PVC Conduit Pipe
Fixing of I/O Box set
Fixing of Rack
Fixing of UTP patch panel
NAGARJUNA ENGINEERING WORKS
maple tree projects
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .