Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC 3D SHANTI MANZIL 98 1 MADARIPURPALLY RAHARA KHARDAHA NORTH 24 PARGANAS WEST BENGAL 700118 | 24 PARAGANAS NORTH | WEST BENGAL | 700118 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.1 L+₹70.56 (0.01%)Rejected-Finance 50 A BILAYET ALI ROAD TALPUKUR BARRACKPORE KOLKATA 700123 | BARRACKPORE | 24 PARAGANAS NORTH | WEST BENGAL | 700123 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.1 L+₹635.03 (0.09%)Rejected-Finance VILL KABILDANGA P O BAMUNIA P S KASHIPUR SOUTH 24 PARGANAS | 24 PARAGANAS SOUTH | WEST BENGAL | 700070 | L3 | Rejected-Finance L3 |
Tender Value
₹7.1 L
EMD Value
₹14,112
Closing Date
13 Mar 2026, 4:30 pmClosed
EO, Bhangore-II PS
Bhangore Bijoyganj Bazar
Supply and Installation of 23 Nos 7 mtr. Long pole with 100w LED Street Light from Bhojerhat Bridge to Palpara under Beonta-I G.P. under Bhangore-II Panchayat Samity under MPLAD 2025-26.
2026_ZPHD_1018637_3
NIT39MPLAD
Open Tender
Electrical Work/ Equipment
Percentage
15 days
Beonta-I
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹14,112
Yes
7 Sept 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
13 Mar 2026
6 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying of Swaged Steel Tubular pole (IS 2713, Pt. II 1980)
for following designation and of following dimensions [ Ref :- UDMA-2018/Page -1 ] [Make :- Subham Pole/Utkarsh/Bajaj or as approved by EIC ]
410-SP-1; 7.0 mtrs: 62.00Kg | 23 | nos | 5,277 | ₹1,21,371 |
| 2 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish
and GI earth bolt after making drilled holes etc. on pole & carriage
of pole upto 1.6 Km from Store to work-site including filling up
the excavated earth pit with shifted soil and ramming properly.Upto 9 mtr. [ Ref :- WBPWD-2017/Page- H-1/Item-1 ] | 23 | nos | 2,835 | ₹65,205 |
| 3 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on
steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint [ Ref :- WBPWD-2017/H-5/Item-5 ] | 23 | nos | 458 | ₹10,534 |
| 4 | Supplying of 100Wt. LED Flood light fittings. (Like Model no- ENDURASUNDOWNSL100WLED765PASYBOTG-Havells/Philips Make) | 23 | nos | 6,112 | ₹1,40,576 |
| 5 | Distribution wiring for steel light on pole for outdoor fluorescent/SV/MV light fitting with 2x1/1.40 PVC insulated and sheathed cu wire (single core) in 15 mm dia GI Pipe (ISI-Medium), without control switch, incl. fitting and fixing the light fitting by providing 32 mm dia GI Pipe bracket of lengh 1.05 mts, on pole incl. S&F sutable MS flat clamps with bolts, nuts etc. as required and painting [ Ref :- WBPWD-2017/Page-H-5/Item-H(2) ] | 23 | set | 999 | ₹22,977 |
| 6 | Supply & Delivery 1.1 KV grade 2 core 6 sq.mm. PVC/XLPE insulated Al armoured cable (Make: - Gloster/Mescub/RR Cable/KEI ) | 520 | mtr | 140 | ₹72,800 |
| 7 | Laying of one No. cable upto 35 sqmm in underground trench 460
mm wide x 760 mm average depth, with brick protection on the
top of the cable with 8 (eight) Nos. bricks per metre, including
filling the space between the brick & cable and also the trench
with shifted soil, leveling up and restoring surface duly rammed [ Ref :- WBPWD-201/Page-F-2/1(a) ] | 520 | mtr | 162 | ₹84,240 |
| 8 | Supplying & Erection of medium size feeder pillar box of Size Each 9241.00 (1200 x 750 x 450 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the
front & back with suitable locking arrangement. The box will be
painted by 2 cores of aluminiam paint over 1 coat of red oxide
paint. Suitable arrangement should be provided for fixing of
Timer unit, fuse unit & other accessories. Leg of the pillar box
will be 900 mm in length by made up of (35 x 35 x 3 mm MS
Angle with suitable base Plate. Legs of the Pillar box will be
erected at 300 mm below the ground level with cement concrete
(6:3:1). Rest portion coverd by 5" Brick Wall with plastering &
net cement & bottom portion filled with silver sand as drawing
& direction of E.I.C [ Ref :- UDMA-2018/Page-7/Item-39 ] | - | nos | 9,060 | - |
| 9 | Installation the feeder pillar box only on cement brick foundation including plastering and neat cementing as per specification and
direction of E.I.C. b) For medium size feeder pillar box. [ Ref :- UDMA-2018/Page-7/Item-36 ] | - | nos | 2,966 | - |
| 10 | Supplying and fixing 240 V, 40A, DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing FEEDER Pillar Box and necessary connection [ Ref :- WBPWD-2017/Page-D-6/ Item - 7 ] | - | each | 938 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
BOQ_2503138.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .