Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE- I/CT/GCC2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
43 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 11)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I (E-3320424), dated: 13.03.2026 (attached)
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. tenderer shall submit GST certificate along with the offer.
All disputes or differences of any kind whatsoever arising out of or in connection with this contract, whether during its execution or after completion, termination, or breach thereof, shall be subject to the exclusive jurisdiction of the competent courts at New Delhi only.
The issues not covered under the tender document shall be governed by General conditions of Contract (GCC) 2022 or its latest amendments if any during entire period of contract. If any contradiction in Tender Document and GCC is observed then GCC shall prevail.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
The Contractor shall comply with all applicable provisions of IS 732:2019 (Code of Practice for Electrical Wiring Installations) for every relevant item mentioned in the NIT Schedule.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 12)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY (3389822), dated: 12.08.2026 (attached)
The contractor has to submit drawing/plan showing route diagram to consignee for signature of concerned SSEs of other departments. It required geological survey to be conducted at his own cost to avoid damage of any other cable/Pipe etc.
Contractor has to depute sufficient number of efficient manpower to carry out the work in parallel at different sites under scope of instant tender. No any excuses regarding non- availability of material and manpower for carrying out the work concurrently/parallelly at various sites shall be admissible.
Since Site of work involves locations across Railway yard and Track in this instant tender, tenderer should note that Tenderer cannot refuse or delay work on the grounds of less convenient locations . The quoted rate in the tender is assumed to cover all such travel, mobilization, and logistic efforts.
The site of work is under the jurisdiction of SSE/PS/ANVT, DKZ, DLI, TKD & Th. Road. However, site can be changed anywhere in Delhi Division, if required.The tentative locations for the work of "Supply, Erection, Testing and Commissioning of 16 Metre High Mast System with Associated Works" are at the following stations or their adjoining areas, under the respective jurisdictions of : 1. SSE/PS/ANVT, 2. SSE/PS/DKZ [Patel Nagar (PTNR), Dayabasti (DBSI), Brar Square (BRSQ), Narela (NUR), Adarsh Nagar (ANDI)], 3. SSE/PS/TKD [Okhla (OKA), Faridabad (FDB), Ballabgarh (BVH)], 4. SSE/PS/Th. Road [New Delhi Area, Shivaji Bridge (CSB) Area, Tilak Bridge (TKJ) Area]. However, the exact location will be decided by the concern area officer at the time of execution of the work.
Improvement of illumination to enhance the security arrangement at around the railway stations over Delhi Division.
111-SRDEE-G-DLI-2026-27~NR
111-SRDEE-G-DLI-2026-27
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹3.9 L
16 Sept 2026
16 Sept 2026
24 Sept 2026
49 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,96,01,175 | ||
| — | 2800.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed 2016), IS 732:2019 or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Upto 35 sq. mm | — | — | — | 10,66,800 | |
| — | 700.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed 2016), IS 732:2019 or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 3,11,500 | |
| — | 600.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed 2016), IS 732:2019 or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 2,82,000 | |
| — | 600.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed 2016), IS 732:2019 or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm & maintaining gap not less than 20 cm between cables] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Upto 35 sq. mm | — | — | — | 1,77,600 | |
| — | 150.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed 2016), IS 732:2019 or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm & maintaining gap not less than 20 cm between cables] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 35 sq. mm and upto 95 sq.mm | — | — | — | 47,100 | |
| — | 200.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed 2016), IS 732:2019 or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm & maintaining gap not less than 20 cm between cables] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 66,800 | |
| — | 600.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed 2016), IS 732:2019 or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Upto 35 sq. mm (clamped with 1mm thick saddle) | — | — | — | 36,000 | |
| — | 150.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed 2016), IS 732:2019 or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | — | — | — | 21,450 | |
| — | 200.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed 2016), IS 732:2019 or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | — | — | — | 33,600 | |
| — | 6000.00 | — | — | ||
| Laying, dressing, terminating, and testing of 1-core, 16 sq.mm to 120 sq.mm, 1.1 kV grade, PVC/ XLPE insulated, armoured/unarmoured Aluminium/ copper conductor cable for TN-S earthing system, laid in the same trench/HDPE pipe/Cable Tray along with power cables (laying mentioned in S. No. 01 to 09) as per IS 732:2019 or latest, providing and fixing of cable identification tags, supply and fixing of suitable size brass/compression glands, crimping type Aluminium/copper lugs, jointing (if required), insulating tapes, ferrules, and making proper end terminations and connections to equipment and earth bus/bar, complete as required & as per explanatory note. | — | — | — | 5,10,000 | |
| — | 300.00 | — | — | ||
| Supply, laying, testing and commissioning of 160 mm dia. HDPE pipe (PE-100, PN-6) conforming to IS:4984 or latest and cable laying by trenchless Horizontal Directional Drilling (HDD) method as per IS:1255 or latest, IS 732: 2019 or latest, IE Rules, CPWD and Indian Railways specifications, including detailed route survey, marking of alignment, pilot drilling, reaming, supply and laying of pipe by pull-back method with butt fusion/electrofusion jointing, use of suitable drilling fluid, and maintaining required depth and alignment (generally 1.5 m to 3.5 m or as directed). The work shall include preparation and submission of complete HDD report comprising route alignment drawings with chainage and coordinates of entry/exit points, section-wise details of HDD lengths, depth profile graphs (depth vs chainage), HDD logs, and photographic records, as per site requirements. The item also includes testing, quality assurance, protection of existing utilities, disposal of slurry, restoration of site, and all incidental works complete in all respects as directed by Engineer-in-Charge & as per explanatory note. | — | — | — | 3,46,800 | |
| — | 36.00 | — | — | ||
| Supply, erection, testing and commissioning of 16 meter high mast system suitable for 9 Nos. LED flood light luminaries with the help of suitable equipment including accessories for high mast system for provision of AC type voltage independent RCBO in place of MCB from I/C side (in panel). Each high mast shall also have one twin dome aviation obstruction light with 2 nos. LED lamp. Make BAJAJ, Osram, PHILIPS, GE or equivalent conforming to IS 875 (Part 3) for wind load considerations, IS 2062 for structural steel used in pole fabrication, IS 17740 for high mast lighting system design and installation and conforming to RDSO Technical Circular No. RDSO- EEM0LKO(SMI)/2/2026, dated: 20.07.2026 or latest. After installation the contractor shall also provide report of leakage current measured after complete commissioning of system and it should be under values defined under IS/IEC & as per explanatory note. | — | — | — | 92,68,272 | |
| — | 324.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150-155 watt LED based flood light luminary with cool white light, pressure die cast aluminum housing, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev-'3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 24,45,228 | |
| — | 36.00 | — | — | ||
| Supply, fixing, testing and commissioning of Astronomical Timer Based Automatic Lighting Control Panel for High Mast Lighting System, complete with Astronomical Time Switch equivalent to Legrand Alpha Rex3 D21, 1 Channel (Cat. No. 412654) or approved equivalent, suitable for 415V, 3 Phase, 4 Wire, 50Hz AC supply. The outdoor floor-mounted, double-door, dust and weatherproof panel shall have minimum IP54 protection with canopy, powder-coated CRCA sheet steel enclosure, conforming to IEC 60947 and IEC 60529 and other relevant standards. The panel shall comprise minimum 25A, 4P AC-3 contactor, 32A 30 mA TPN voltage independent AC type RCBO (10kA), copper Bus bars for incomer and outgoing as required, 6A SP MCB, MCB TPN of required size, Auto/Manual selector switch, UP/DOWN push buttons (for hoist movement), LED indication lamps, terminal blocks, FRLSH copper control wiring, gland plate with double compression brass glands, earthing arrangement, danger notice and circuit labels. The panel shall be properly wired with circuit tags, tested and supplied complete with all accessories, mounting hardware, installation, testing and commissioning as required at site. Circuit drawing of panel should be approved proirly from competent authority. The earthing stud should also be provided as per IS/IEC guidelines and as per explanatory note. | — | — | — | 10,62,000 | |
| — | 250.00 | — | — | ||
| Fabrication, supply, testing and erection of Heavy Duty Protective Fencing around High Mast Tower (HMT) complete with foundation, excavation, concreting, grouting, erection, testing and commissioning. The fencing shall be square type of minimum 2.0 m x 2.0 m, fabricated from MS Angle 40x40x6 mm and MS Flat 40x6 mm, enclosed on all sides and top with 8 SWG welded wire mesh (maximum mesh size 75 mm x 25 mm). The fencing shall be provided with a lockable access gate, top protective mesh cover, earthing continuity through 25x3 mm GI strip, bilingual danger notice, identification plate and all necessary accessories. The fencing height shall be suitable to maintain minimum 300 mm clearance below the lowest maintenance position of the lantern carriage while providing minimum 1.8 m height above finished ground level. All structural steel members shall be hot-dip galvanized after fabrication as per IS 4759 with all galvanized hardware, complete in all respects as approved by the Railway Engineer and as per explanatory note. | — | — | — | 8,00,000 | |
| — | 5.00 | — | — | ||
| Casting of RCC foundation for High Mast (10 meter octagonal) as per OEM's Design & Drawing approved by Railways & as per explanatory note. | — | — | — | 47,765 | |
| — | 30.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Single Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long (or as per site requirement & approval of competent authority) suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker & numbering shall be done with sticker/paint. The terminal shall be protected with a 500 mm long reinforced and weatherproof door. The door shall be provided with an internal locking arrangement and with a chain arrangement and gasket. The pole foundation shall be erected strictly as per the pole manufacturer's design & as per explanatory note. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm FRLSH double insulated weather proof cables conforming to IS 456 & other relevant IS/IEC standards. | — | — | — | 3,45,120 | |
| — | 10.00 | — | — | ||
| Supply, testing & erection of 10-meter Octagonal Pole (Hot Dipped Galvanized) with provision of 04 Nos. LED fitting at the top; material construction as per IS 2062, thickness of pole 3-4 mm, top dia. 70 mm minimum, bottom dia. 175 mm minimum, metal protection as per IS 2629, size of base plate 350x350x20 mm (Approx.), size of bolt 24x750 mm approx. (04 nos.). It should have an opening for connections at the bottom having locking arrangement with Allen key and Anti- theft arrangement. It should comply with All relevant IS/IEC standards & as per explanatory note. | — | — | — | 2,77,300 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of 45 watt LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev-'3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 95,220 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of 90 watt LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev-'3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 2,65,120 | |
| — | 55.00 | — | — | ||
| Earthing with 40 mm dia. GI pipe class 'B' 4.5 meter long earth electrode as per IS:3043 (latest version) including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mm x 400 mm) on top, and water pipe etc. with charcoal/coke and salt as required and provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per explanatory note. | — | — | — | 3,26,920 | |
| — | 275.00 | — | — | ||
| Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required as per IS: 3043 (or latest version) & as per explanatory note. | — | — | — | 15,125 | |
| — | 275.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode confirming to relevant IS as per IS:3043 (or Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required & as per explanatory note. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) | — | — | — | 42,350 | |
| — | 5.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar, IP 55 conforming to IS/IEC 61439 Part 1&2, Edition-3 2020 or latest, Form of separation-3B, body made of CRCA sheet steel with anti-corrosion treatment, (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Siemens, LK, Schneider, Legrand or equivalent conforming to IEC 60947-2 or latest with digital measuring instrument & Al bus-bar arrangement as per relevant IS, IE rules and site requirement & as per explanatory note. a) 4P MCCB 250 Amps 36kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) b) 4P MCCB 63 Amps 36kA with adjustable thermal & fixed magnetic release = 06 Nos.(Outgoing) | — | — | — | 17,11,105 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ModifiedSpecialConditionsofContract_1.pdf SPECIAL CONDITIONS
ATTACHMENT
GCC-2022-ACS-12compressed.pdf
ATTACHMENT
High Mast Tech Circular as per RDSO
ATTACHMENT
ModifiedTechSpecforHighMast.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
TenderDocument_1.pdf
ATTACHMENT
ModifiedExplanatoryNote_1.pdf
ATTACHMENT
HighMastTechnicalCircular-RDSO-21-Aug-2026_compressed.pdf
ATTACHMENT
ModifiedSpecialConditionsofContract_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .