| 1 | L1₹13.9 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹13.9 L Quoted ₹14.7 L | L1 | Accepted-AOC Accepted being lowest quoted rate |
| 2 | L2₹17.0 L+₹2.3 L (15.6%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹17.0 L+₹2.3 L (15.6%) | L2 | Rejected-AOC Not accepted since higher quoted rate |
| 3 | L3₹17.7 L+₹3.0 L (20.1%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹17.7 L+₹3.0 L (20.1%) | L3 | Rejected-AOC Not accepted since higher quoted rate |
| 4 | L4₹19.2 L+₹4.5 L (30.5%)Rejected-AOC | ₹19.2 L+₹4.5 L (30.5%) | L4 | Rejected-AOC Not accepted since higher quoted rate |
| 5 | L5₹19.8 L+₹5.1 L (34.4%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹19.8 L+₹5.1 L (34.4%) | L5 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
Refer Docs
EMD Value
₹29,400
Closing Date
12 Sept 2020, 6:00 pmClosed
GE Army Gandhinagar
Garrison Engineer Army PO BSF Campus Gandhinagar
REPAIR MAINTENANCE OF COOLING APPLIANCES CEILING FAN EXHAUST FANS AND GEYSERS AT MIL STN DHRANGADHRA
2020_MES_369998_1
GE(A)/GNR/TOKEN/50 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Military Station Dhrangadhra
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE Army Gandhinagar
₹29,400
Yes
14 Oct 2020
18 Aug 2020
14 Sept 2020
18 Aug 2020
12 Sept 2020
30 Aug 2020
18 Aug 2020 - 28 Aug 2020
Amount
Opening (De-assembling) of the ceiling fan, 1200mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and flexible twisted copper cable of 23/0.0076 gauge and testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 2.5 Mfd suitable for 1200 mm sweep ceiling fan.
Supply only ball bearing suitable for 1200mm sweep ceiling fan.
Supply only gun metal bush suitable for 1200mm sweep ceiling fan of appropriate make.
S&F, in repair, capacitor of 2.5 Mfd suitable for 1200 mm sweep ceiling fan.
S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed.
S&F, in repair, MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
M&L for preparation of surfaces of ceiling fan including blade and applying one coat of white/brown synthetic enamel paint after taking down in respective items all as specified and directed.
Taking down of ceiling fan 1200 mm sweep from existing position/hook, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 250 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 300 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
Opening (De-assembling) of exhaust fan 300 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing in position and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Opening (De-assembling) of exhaust fan 380 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing in positio and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Opening (De-assembling) of exhaust fan 450 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling, refixing in positio and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 4.0 Mfd suitable for exhaust fan.
Supply only ball bearing suitable for 300/380/350mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 300/380/350mmmm sweep exhaust fan complete.
Taking down exhaust fan of size 300/380/450 mm sweep from existing position, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
M&L for preparation of surfaces of exhaust fan of size 300/380/450mm including blade, frame/louver and apply one coat of block synthetic enamel paint after taking down in respective items all as specified and directed.
Disconnecting carefully water and electric connection from storage type water heater of 25 ltr cap of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing and re-fixing in existing position complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly shall be measured and paid under relevant items as "Supply Only". (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
S&F, in repair, heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
S&F, in repair, heating element of 2.0 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
S&F, in repair, thermostat assembly for geyser, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed.
S&F, in repair, indicating lamp suitable for existing entry of geyser complete all as specified and directed.
S&F, in repair, 15mm bore 600mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair, semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed.
S&F, in repair, PVC insulated and PVC sheathed cable 3 core, 2.5 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
S&F, in repair, syphon assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitble for 25 ltrs capacity geyser all as specified and directed.
S&F, in repair, glass wool superior quality around the water container as heat resistance upto full capacity complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 1.5 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 2 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of window/Split type A/C, 1.5 to 2 TR capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, starting relay of water coolers 40/80 Ltr capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of A/C 1.5 to 2 TR complete all as specified and directed.
S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 310 Ltr complete all as specified and directed.
S&F, in repair, Thermostate suitable for A/C 1.5 to 2 TR complete all as specified and directed.
S&F,in repair, Starting capacitor 230 Volt, 100-150MFD suitable for AC's complete all as specified and directed.
S&F,in repair, Starting capacitor 230 Volt, 80-100MFD suitable for AC's complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 4.0 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 6.3 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 36/45 MFD complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for window/split type A/C of capacity 1.5 & 2 TR and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Deep Freezer of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repairs, water lift submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
S&F, in repair, fan motor (ISI Marked), 1/6 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed
S&F, in repair, wood wool pads, superior quality, size 60x45 cm (approximate), complete all as specified and directed
S&F, in repair, front grills adjustable type made of 22 guage PGI sheet matching with existing model, complete all as specified and dircted.
S&F in repair sheet metal enclosures single pole & natural with a two pin & earth plug and socket complete with one single pole MCB of 20 amps, complete all as specified and directed
S&F, in repair, Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixing complete all as sepcified and directed.
S&F, in repair, stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
S&F, in repairs, Gun metal, 15mm bore, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed.
S&F, in repair, MCCB, 63 Amps, 4 Pole, 415 Volts of breaking capacity 25 KA, including connecting complete all as specified and directed. Makes of Standard/Havells/ABB
S&F, in repair, MCCB, 100 Amps, 3 Pole, 415 Volts of breaking capacity 25 KA, including connecting complete all as specified and directed. Makes of Standard/Havells/ABB
S&F, in repair, MCCB, 200 Amps, 3 Pole, 415 Volts of breaking capacity 35 KA, including connecting complete all as specified and directed. Makes of Standard/Havells/ABB
S&F, in repair, MCCB, 200 Amps, 4 Pole, 415 Volts of breaking capacity 35 KA, including connecting complete all as specified and directed. Makes of Standard/Havells/ABB
S&F, in repair, MCCB, 250 Amps, 4 Pole, 415 Volts of breaking capacity 35 KA, including connecting complete all as specified and directed. Makes of Standard/Havells/ABB
ALBA AC AND REF SERVICES
ARTI CONSTRUCTION
Singh Engineer And Contractor
Electricals India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .