Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.7 L+₹1.2 L (3.38%)Rejected-Finance BLDG NO XXVIII 378A NORTH CHAMPANOOR ANGAMALI SOUTH P O PIN 683 573 | ANGAMALI | ERNAKULAM | KERALA | 683573 | L2 | Rejected-Finance L1 Being accepted | |
| 3 | L3₹40.6 L+₹5.1 L (14.5%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L3 | Rejected-Finance L1 Being accepted |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
14 Jun 2021, 6:00 pmClosed
GE (I) (CG) KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
PROVISION OF GROUND SUPPORT EQUIPMENT GSE SHED FOR ALH MK-III SQN AT CGAE K NEDUMBASSERY KOCHI
2021_MES_443590_1
8764/CG/E8
Open Tender
Civil Works
Item Rate
180 days
NEDUMBASSERY KOCHI
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I) (CG) KOCHI
₹78,000
Yes
30 Jun 2021
18 May 2021
21 Jun 2021
18 May 2021
14 Jun 2021
2 Jun 2021
18 May 2021 - 24 May 2021
Amount
SCHEDULE 'A' PART-I (B/R WORKS)
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for unreinforced complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth and getting out excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Removing excavated soil to a distance not exc 50m and deposited where as directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
Returning, filling, including spreading leveling, watering and well ramming in layers not exc 25 cm thick in soil all as specified and directed.
Material and labour for Plain cement concrete 1:4:8, type D2, using 40mm graded stone aggregate as in foundation filling and mass concrete including necessary form work all as specified and as directed.
Material and labour for RCC M-30 design mix using 20 mm graded stone aggregate as in foundations including raft, footings, plinth beam and mass concrete and similar work complete all as specified and as directed.
Use and waste of formwork to sides of foundation footing, for rough finished surfaces, flat complete all as specified and as directed.
Material and Labour for TMT(CRS/HCR) bar 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping ,for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for TMT bar 6 to 8mm dia, cut to length, bent to shape required including bending or hooking ends and binding with and including mild steel wire (annealed) not less than 0.9m dia complete as in reinforcement complete all as specified and as directed.
Material and labour for TMT bars(CRS/HCR), 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Supply and fix 1.6mm thick Mild steel, plain, black sheet in wall cladding and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
Supply and fix rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats conforming to Fe-410W(Gde E-250) quality A complete all as specified and as directed.
Supply and fixing Pre- painted galvalume aluminum zinc coated corrugated sheet of 0.50mm thickness having tensile strength of 550 Mpa with coating thickness fixed with GI self taping screws as in roof covering/cladding to wall, ridges, valley gutters fixed to frame work all as per manufacturers instructions all as specified and as directed.
Supply and fixing Pre- painted galvalume aluminum zinc coated 0.5mm thick prepainted plain galvalume sheeting as in ridge and cladding, fixed with GI self tapping screw complete all as specified and as directed.
Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and ncluding either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Grade E-290, Fe 410 W quality A complete all as specified and as directed.
Material and labour for preparation of new or previously untreated steel surface and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fix PVC half dia Rain water gutter 200mm width fixted to purlins with MS Clamps of Flat iron complete all as specified and as directed. Note: MS clamps shall be measured and paid under the relevant item.
Dismantling the existing 200 mm dia rain water pipes and refixing the same as directed by the Engineer-in-charge.
Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Material and labour for precast cement concrete solid block masonry using Solid PCC block type C4 exceeding 10 Cm width, built in cement mortar 1:4 all as specified and as directed.
Material and labour for 75mm thick plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in floors finished even and smooth without using extra cement, mixed with metallic floor hardener as per direction of the Engineer-in-charge including necessary form work complete all as specified and as directed. NOTE: Metallic floor hardener shall be measured and paid separately.
Supply only metallic floor hardener complete all as specified and as directed.
Supply and fix for mild plate(plain or chequerred), channel, square cut or notched(ordinary or counter sunk) forming holes with riveted, bolted or welded attachment to bottom of pipe conforming to Fe 290-W quality A(Gde-E-165) complete all as specified and directed.
Supply and fix PVC Rain water pipes of 150mm dia vertically fixed to wall/ clading using MS clamps. Top end of the pipe shall be jointed with Rain water gutter complete all as specified and as directed. Note: MS clamps shall be measured and paid under the relevant item.
SCHEDULE 'A' PART-II (E/M WORKS)
Material and labour for point wiring with PVC insulated unsheathed, multistranded FRLS copper conductor colour coded with cable 1.5 Sqmm size, 1100 volts grade, confirming to IS:694 drawn through and including stove enamelled steel concealed conduit including all accessories as bend, tee, junction boxes elbows etc in new GI boxes made out of sheet 1.6 mm thick including one coat of synthetic enamel black paint and providing new 3mm thick plastic laminated sheet cover of approved colour fixed with brass screws and cup washers, including single core stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common eatrh and connected to earth dolly and earth terminal box for one light / fan point controlled by one way switch 5/6 Amp complete all as specified and directed.
Material and labour for point wiring with PVC insulated unsheathed, multistranded FRLS copper conductor colour coded with cable 2.5 Sqmm size, 1100 volts grade, confirming to IS:694 drawn through and including stove enamelled steel concealed conduit including all accessories as bend, tee, junction boxes elbows etc in new GI boxes made out of sheet 1.6 mm thick including one coat of synthetic enamel black paint and providing new 3mm thick plastic laminated sheet cover of approved colour fixed with brass screws and cup washers, including single core stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common eatrh and connected to earth dolly and earth terminal box for one power point 16 Amp controlled by one way switch 16 Amp complete all as specified and directed.
Supply and fix Modular switch one way 6Amp, 1 Module complete all as specified and as directed.
Supply and fix Modular Switch socket outlet 3 pin, 16 Amp complete all as specified and as directed.
Supply and Fix Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way vertical with 200 Amps rated copper bus bar double door neutral bar,earth bar, 240 volts for MCBs complete all as specified and as directed. NOTE: MCB shall be measured and paid separately.
Supply and Fix Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way vertical with 200 Amps rated copper bus bar double door, neutral bar,earth bar, triple pole and neutral 440 volts for MCBs complete all as specified and as directed. NOTE: MCB shall be measured and paid separately.
Supply and fix MCB SP, 240Volts, 6 to 32 Amps, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Supply and fix MCB TPN, 415Volts, 32 Amps, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Fixing only ceiling fan 1200mm sweep complete with all accessories as specified and directed. Note:- Ceiling fans will be provided by the department.
Fixing only 50Watt LED Flood light complete with all accessories as specified and directed. Note:- LED Flood lights will be provided by the department.
Fixing only MCCB 415V,16KA, 4 Pole rated current carrying capacity of 63A complete with all accessories as specified and directed. Note:- MCCBs will be provided by the department.
Supply and fix MCB SPN, 240Volts, 32 Amps, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Laying only cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric cable, heavy duty, 1100 volt grade with stranded aluminium conductor cables of following sizes fixed in wall/ roof or laying in trenches etc., all as directed of 35 Sqmm 3.5 core complete all as specified and as directed. NOTE: (i) XLPE cable will be provided by the department at site. (ii)Excavation, earth work shall be measured and paid for separately.
Supply and fix RCCB for Earth Leakage protection Double Pole, 30 mA with current rating up to 25A complete all as specified and as directed.
Supply and Fix enclosure for MCCB made out of sheet metal enclosure (CRCA sheet), dust and vermin proof complete all as specified and as directed. NOTE: MCCBs will be provided by the department.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel protected by GI pipe 15mm bore light grade and watering pipe 20mm bore GI pipe medium grade all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
Material and labour Sub main/circuit wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable(FRLS) 1100 volts grade multi standard copper conductor drawn through and including stove enamelled steel conduit of suitable size including all accessories as bend,tee,junction boxes elbows etc, fixed in walls/roof including one run of 6 sqmm earth continuity PVC insulated copper wire(FRLS) complete all as specified and as directed. Note : 3 runs of 6 Sqmm cable, one run of steel conduit shall be measured as one length.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth and getting out excavated earth, forming bottom surfaces to required level complete all as specified and directed.
K R JOSEPH AND SONS
M/s.Rejoy Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .