Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-Finance VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | ₹3.4 L | L1 | Accepted-Finance L1 |
| 2 | L2₹3.8 LRejected-Finance BELOW SLAUGHTER HOUSE KRISHNA NAGER SHIMLA | SHIMLA | SHIMLA | HIMACHAL PRADESH | ₹3.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹3.9 LRejected-Finance | ₹3.9 L | L3 | Rejected-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical R O SUJANPUR TEHSIL DISTT HAMRIPUR | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | SANJAY SAINI L1 | pankaj saini L3 | Sunil Kumar L2 |
|---|---|---|---|---|---|---|
| 1.00 | 50 HP Pumping machinery Dismantling of common header due to raise up of pumping machinery foundation complete in all respect as per direction of Engineer in charge with in all leads and lifts. | 1 | No. | 20,000 ₹20,000 | 22,000 ₹22,000 | 19,000 ₹19,000 Lowest |
| 2.00Providing and laying column assembly of GI/MSERW pipes of suitable size for suction delivery and common header considering site requirements and NPSH required/ avaiable.The pipe sizes for suction and delivery shall as per the requirement of offered pump (to be given by the tendrers) and common header shall be equal to dia of rising main including tapers, flanges, bends, rubber gaskets, 3 mm thick nuts and bolts and special up to 5 metre away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge. The pipes material shall confirm to relevant BIS codes and capable of with standing field test pressure equal to 1.5 times the operating pressure. The complete arrangement shall comprise of:- | ||||||
| 2.10Suction pipe 80 mm dia | ||||||
| 2.20Delivery pipe | ||||||
| 2.30 | Common header 80 mm dia | 15 | mtrs | 2,300 ₹34,500 Lowest | 2,500 ₹37,500 | 2,800 ₹42,000 |
| 3.00 | Errection of all equipments of including cost of tees, bends tapers & any other fitting required as per site conditions as per direction of the Engineer in charge . | 1 | Job | 25,000 ₹25,000 | 22,500 ₹22,500 Lowest | 23,500 ₹23,500 |
| 4.00 | Providing and fixing of Kirloskar/ Leader make cast steel double flanged sluice valve (to be provided on delivery side) of size one step higher than the delivery size of pump and capable of with standing nominal seat pressure 52 kg / cm2 as per BIS BS 1414 / API: 600 Pressure / class rating : Class 300 65 MM dia complete with tee i/c nuts and bolts rubber gasket insertion etc. complete in all respect as per direction of Engineer in charge with in all leads and lifts. | 2 | Nos. | 65,000 ₹1,30,000 Lowest | 73,500 ₹1,47,000 | 72,000 ₹1,44,000 |
| 5.00 | Providing and fixing of Kirloskar/ Leader make cast steel double flanged accuator swing check type reflux valve class 300 CCS (ASTMA 216 GR WCB) having by pass arrangement (to be provided on delivery side) of size one step higher than the delivery size of pump and capable of with standing nominal seat pressure 52 kg / cm2 as per BS 1868 / API6D 65 MM dia complete with tee i/c nuts and bolts rubber gasket insertion etc. complete in all respect as per direction of Engineer in charge with in all leads and lifts. | 2 | Nos. | 65,000 ₹1,30,000 Lowest | 78,500 ₹1,57,000 | 75,000 ₹1,50,000 |
Tender Value
₹1.9 L
EMD Value
₹3,866
Closing Date
24 Jan 2026, 10:30 amClosed
EE Jal Shakti Division Thural
EE Jal Shakti Division Thural
RRD for LWSS Kona Saprul Samba in Tehsil Palampur Distt. Kangra (HP) (SH Providing fixing of common header assembly and sluice vale, NRV in Section Garh)
2026_HPIPH_124911_1
EE/JSVD/THL/2025-26-12103-46 Dt. 02.01.2025
Open Tender
Miscellaneous Works
Item Rate
30 days
EE Jal Shakti Division Thural
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Jal Shakti Division Thural
₹3,866
18 Jun 2026
2 Jan 2026
24 Jan 2026
2 Jan 2026
24 Jan 2026
2 Jan 2026
50 HP Pumping machinery Dismantling of common header due to raise up of pumping machinery foundation complete in all respect as per direction of Engineer in charge with in all leads and lifts.
Suction pipe 80 mm dia
Delivery pipe
Common header 80 mm dia
Errection of all equipments of including cost of tees, bends tapers & any other fitting required as per site conditions as per direction of the Engineer in charge .
Providing and fixing of Kirloskar/ Leader make cast steel double flanged sluice valve (to be provided on delivery side) of size one step higher than the delivery size of pump and capable of with standing nominal seat pressure 52 kg / cm2 as per BIS BS 1414 / API: 600 Pressure / class rating : Class 300 65 MM dia complete with tee i/c nuts and bolts rubber gasket insertion etc. complete in all respect as per direction of Engineer in charge with in all leads and lifts.
Providing and fixing of Kirloskar/ Leader make cast steel double flanged accuator swing check type reflux valve class 300 CCS (ASTMA 216 GR WCB) having by pass arrangement (to be provided on delivery side) of size one step higher than the delivery size of pump and capable of with standing nominal seat pressure 52 kg / cm2 as per BS 1868 / API6D 65 MM dia complete with tee i/c nuts and bolts rubber gasket insertion etc. complete in all respect as per direction of Engineer in charge with in all leads and lifts.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Form6.pdf
Tender Documents • 0.43 MB
Form8.pdf
Tender Documents • 1.22 MB
BOQ_183831.xls
BOQ • 0.28 MB
Termsandconditions.pdf
Additional Documents • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].