Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.6 L+₹4.5 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L2₹44.6 L+₹4.5 L (11.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 4 | L3₹46.0 L+₹5.8 L (14.4%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L3 | Rejected-Finance Other than lowest | |
| 5 | L4₹49.7 L+₹9.5 L (23.8%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
18 Jan 2023, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
REPAIR / REPLACEMENT / MAINTENANCE OF STREET AND SOLAR LIGHT POLE, UG CABLE, LINKS, FEEDER PILLAR AND ALLIED WORKS AT INS SARDAR PATEL AND NAVAL AIR ENCLAVE UNDER GE NAVY PORBANDAR
2022_MES_570483_1
9157/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹76,000
Yes
30 Jan 2023
21 Dec 2022
20 Jan 2023
21 Dec 2022
18 Jan 2023
5 Jan 2023
22 Dec 2022 - 4 Jan 2023
Amount
Dismantling of U/S insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
S & F pin type insulator 150mm height and 150mm dia for 11000 Volts grade, porcelain White, Brown or Green including one GI spindle, two GI washer, one GI nut all as specified and directed by Engr-in-charge.
S & F HT disc insulator porcelain vitreous 145mm height, 255mm dia, ball and socket type. White / brown with M.S. galvanized iron fitting suitable for working pressure 11KV all as specified and directed by Engr-in-Charge.
Dismantling of U/S existing cross arms by means made from channels, angles, U/S FI clamps, nuts, bolts etc. from OH line and removing complete.
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
Dismantling of existing U/S HT/LT pole of any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil/strata, demolition of concrete, disconnection of conductor fom pole etc complete all as directed.
supply and install steel, tubular swaged poles complete with cast iron base plate, nuts and taper plug, bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long) complete all as directed.
supply and install steel, tubular swaged poles complete with cast iron base plate, nuts and taper plug, bolts, nuts and screws as specified type 410-SP-55 (11mtr long) complete all as directed.
Supply and fix cable end termination suitable for XLPE, HT under ground cable, 95 sqmm, 3 core, 11000 volt, heat shrink type indoor end termination complete all as directed.
Supply and fix cable end termination suitable for XLPE, HT under ground cable, 95 sqmm, 3 core, 11000 volt, heat shrink type out door end termination complete all as directed.
Supply and fix cable straight through suitable for XLPE, HT under ground cable, 95 sqmm, 3 core, 11000 volt, heat shrink type complete all as directed.
Dismantling of Air Breake Gang Operated switch vertical/Horizontal mounted HT 11 KV incluidng insulator and operating Mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and directed by Engr-in-Charge.
S & F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps complete all as specified and directed
Removing of old existing unservicable / deffective lighting arrestor HT 11 KV and shifting to store complete all as specified and directed
M& L for Lightning arrester NON LINEAR TYPE complete with all fittings distribution class discharge capacity 65 kilo amp, current rating 5 KA suitable for 11000 volt with all fittings complete all as specified and directed.
Dismantling carefully the existing U/S LT/HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Supply and fixing of stringing ACSR conductor for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size complete all as specified and directed.
PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, Benching, kneelers, apex stones, bed plates, kerbs, saucer drain(including finishing top surface of drain even and smooth without using extra cement), water troughs and the like including weathering, slightly rounded or chamfered angles and throating, and similar work including use & waste of necessary form work complete all as specified and as directed.
Taking down U/S UG cable from trenches, walls, floor, pole etc of any size complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 6 sqmm 2 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 2 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 16 sqmm 2 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 25 sqmm 2 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 4 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 16 sqmm 4 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 25 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along polecomplete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 70 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 95 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 150 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 185 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 240 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-7098 (part-1) 1988 with latest amendment laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note for item No. 21.00 to 35.00 :- Excavation, earthwork, DWC pipe, GI pipe shall be measured and paid for separately.
Supply, laying and fix of Cable laid in trenches, passing through pipes and fixed on wall/floor/ceiling with proper saddles , including testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of following size 95 sq mm 3 core complete all as specified and directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. The Excavation, earthwork, DWC pipe etc will be measured and paid separately under respective items
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of Pole, laying of cable and getting out in hard dense soil complete as specified and directed.
Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified.
Removing of excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Double Walled Corrugated (DWC) HDPE pipe of size 40 mm outer dia and 32 mm inner dia conforming to IS 16205 Part - 24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Double Walled Corrugated (DWC) HDPE pipe of size 50 mm outer dia and 38 mm inner dia conforming to IS 16205 Part - 24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Double Walled Corrugated (DWC) HDPE pipe of size 63 mm outer dia and 50 mm inner dia conforming to IS 16205 Part - 24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Double Walled Corrugated (DWC) HDPE pipe of size 75 mm outer dia and 63 mm inner dia conforming to IS 16205 Part -24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Double Walled Corrugated (DWC) HDPE pipe of size 90 mm outer dia and 75 mm inner dia conforming to IS 16205 Part -24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Double Walled Corrugated (DWC) HDPE pipe of size 110 mm outer dia and 95 mm inner dia conforming to IS 16205 Part -24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe complete all as specified and directed.
Galvanised tubing light grade 50 mm for cable protection, laid under plints / floors / roads / paths / culverts of fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I. clamps with necessary bolts nuts washers complete all as specified and as directed.
Galvanised tubing light grade 100 mm for cable protection, laid under plints / floors / roads / paths / culverts of fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I. clamps with necessary bolts nuts washers complete all as specified and as directed.
Taking down of faulty LT under ground cable of size 3.5 core 10 Sqmm to 240 Sqmm from trenches / pole / wall etc for detecting fault including repair and jointing at site including relaying at the same location complete. Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable) and accessories suitable for 4 core XLPE armoured, alluminum conductor cable of size 10 to 16 sq mm and all as directed by Engineer-In-Charge.
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 25 to 50 sq mm and all as directed by Engineer-In-Charge.
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 to 150 sq mm and all as directed by Engineer-In-Charge.
Taking down of faulty HT under ground cable of size upto 120 sqmm from trenches /pole/wall etc for detecting fault including repair and jointing at site including relaying complete.Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 32x6mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Taking down old u/s LT panel of any size/ make/ including all unserviceable parts removing from site and depositing to store complete all as specified and directed.
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) Onload Manual Change Over Switch Open execution type (L &T Model No- CO21600OOOO) Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 420057) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- MCCB 100A TP 16 kA with thermal magnetic release (Legrand Cat No. 4200 05) -02 Nos (b) All out going LT feeders name with radium stickers -02 Nos Note:- MCCB
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 420057) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 63A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -02 Nos , (b) MCCB 40A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 02) -01 Nos (c) All out going LT feeders name with radium stickers -03 Nos
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 500 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 500 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 400A TPN 36 kA with thermal magnetic release ( Legrand Cat No 4220 07) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 160 A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 47) -02 Nos , (b) MCCB 63A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -01 Nos (c) All out going LT feeders name with radium stickers -03 Nos
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 300 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 300 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 250 A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4202 19) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 63A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -01 Nos , (b)TIME SWITCH (L &T Cat No 67DDT9) -01 No (c) ML3 Contactor 3 Pole Current rating not less than 40 Amps (L &T Cat No SS90721)-01 No (d) All out going LT feeders name with radium stickers -02 Nos
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 300 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 300 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 125 A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 56) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 40A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 02) -02 Nos , (b)TIME SWITCH (L &T Cat No 67DDT9) -01 No (c) ML3 Contactor 3 Pole Current rating not less than 40 Amps (L &T Cat No SS90721) -01 Nos (d) MCB 40A SP 'C' Series (L &T Make) -04 Nos (e) All out going LT feeders name with radium stickers -07 Nos
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 300 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified and directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 300 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 200 A TPN 36 kA with thermal magnetic release ( Legrand Cat No 4202 48) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 63A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -05 Nos , (b)TIME SWITCH (L &T Cat No 67DDT9) -01 No (c) ML3 Contactor 3 Pole Current rating not less than 40 Amps (L &T Cat No SS90721) -01 Nos (c) All out going LT feeders name with radium stickers -06 No
Supply & fix in replacement of Operating handle kit (operating handle + shaft + centrebush + bush clip) for Onload changeover switch of capacity 400 Amps complete all as specified and directed.
S& F in replacement of Sheet metal enclosure suitable to accommodate MCCB 160 Amps 4 pole, upto 185 sqmm 3.5 core cable complete all as specified and directed.
S& F in replacement of MCCB 160 Amps 4 Pole 25 ka with thermal magnetic release complete all as specified and directed.
Dismantling and taking down street / security light of any wattage or size fittings for repair or replacement of burnt/worn out accessories or carrying to AGE E/M office complete all as specified and directed.
Fixing only repaired serviceable street / security light fitting of any size & any make on pole / tower /wall of the Hanger of 20 meter height/ Water Tank at 25 Meter height/on bldg of any height etc complete all as specified and directed. NOTE:- No ladder / T&P will be provided for fixing street light on pole/wall/hanger.
Supply & fix in repair Multifunctional digital time switches 110-240 VAC single phase complete all as specified and directed.
Supply & fix Power contactor ML-3, 3 pole rating not less than 40 A 230 coil complete all as specified and directed.
Supply & fix in replacement of Led outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 75 Watt complete all as specified and directed.
Supply & fix in replacement of Led outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 75 -100 Watt complete all as specified and directed.
Supply & fix in replacement of Led outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 100-150 Watt complete all as specified and directed.
Supply & fix in replacement of Surge protection device of RATING 5KV suitable for LED street light /LED flood light fititngs of capacity upto 75 Watt complete all as specified and directed.
Supply & fix in replacement of Surge protection device of RATING 5KV suitable for LED street light /LED flood light fititngs of capacity upto above 75 Watt & upto 150W complete all as specified and directed.
Supply & fix PVC insulated 3 core 1.5 sqmm multistranded Copper conductor on pole for security light from junction box to street light fititng including making necessary hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting fixed in repair / replacement complete all as specified and directed.
Supply & fix PVC junction box of size inside dimenssion 250x200x100 mm complete with industrial connector, including clamp made out of MS flat iron 30x5 mm, nut, bolts, washer, glands etc, MCB 6-10 Amps fixed in repair / replacement complete all as specified and directed.
RUDRAAY CONSTRUCTION
M/S Rajendra Constructions
JAY BHARAT METAL SUPPLIERS
shree chamunda enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .