Deputy Municipal Commissioner (D)
Colour Work of Various Existing Buildings of Hydraulic Department in New East (Sarthana) Zone, Surat Municipal Corporation, Surat.
281102
DMC/HYD/24/2025-2026,Work No:07
Open
Paints / Enamels
Surat
3 documents required · 3 mandatory
₹2,832
Commissioner, Surat Municipal Corporation
₹95,000
26 Feb 2026
26 Feb 2026
26 Feb 2026
13 Mar 2026
26 Feb 2026
1 Distempering two coats with oil bound washable distemper of
approved brand & manufacture & of required shade on wall surface
to give an even shade over and & including a priming coat of alkali
resistance primer of approved brand after throughly brushing the
surface to give an even shade after throughly brushing the surface
free from mortar droppings and other foreign matter and also
including preparing the surface even and smooth.
(A) Wall 12000.00 72.23 S.M.
(B) Ceiling 6000.00 80.35 S.M.
2 Painting two coats (excluding priming coat) on previously painted
wood & wood based surface with enamel paint to give an even
shade & surface incl. cleaning of all dirt, dust & other foreign
3 Painting one coat (excluding priming coat) on Previously Painted
steel and other metal surface with synthetic enemal paint, burshing
to give an even shade including cleaning the surface of all dirt, dust
and other foreign matters.
For every subsequent coat Extra over item no.above 10000.00 38.18 S.M.
4 Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of the
building including scaffolding, preparing the surface, watering,
curing etc. complete and as directed by the architects and
manufacturers.
Surface Preparation :
surface is thoroughly clean, dry and free from all loose dirt, chalk,
grease, fungi, algae and flaking paint. This can be achieved by 85000.00 82.00 S.M.
brushing with a wire/ stiff coir brush, followed by water jetting if
required. Fill up all minor cracks and defects with white cement
and sand mixture in the ratio 1:3. For application on previously
painted wall, previous coatings of paint must be thoroughly scraped
off and Clean the surface thoroughly using wire brushes.
Apply a liberal coat of exterior acrylic primer and allow it to dry for
4-5 hours. Application of putty is not recommended. Minimum 4-6
hours duration is required between each coat of weather shield max
5 White Washing with lime on wall surface to give an even shade &
surface incl. throughly brooming the surface to remove dirt, dust
mortar drops & losse scales of lime wash & other foreign matter
Two coats.
(A) Wall 2000.00 12.41 S.M.
(B) Ceiling 1000.00 13.53 S.M.
DESCRIPTION OF ITEM QUANTITY RATE UNIT AMOUNT
6 Apply two coats of putty and two coats of primer of approved brand
and manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from mortar
dropping and other matter and sand papered smooth
7 Wall painting (two coats) with plastic emulsion paint of approved
brand and manufacture on undecorated wall surface to give an even
shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
8 Applying Priming coat over new steel and other metal surface after
over and including preparing the surface by throughly cleaning oil,
grease dirt and other foreign matter and scoured with brushed fine 100.00 35.00 S.M.
steel wool, scrapers and sand paper with ready mixed priming paint
brushing red lead.
9 Painting two coat (excluding priming coat) on new steel and other
metal surface with synthetic enemal paint, burshing to give an even
shade including cleaning the surface of all dirt, dust and other
foreign matters.
10 Applying Priming coat over new wood & wood surface after &
incl. preparing the surface by throughly cleaning oil grease dirt &
other foreign matter sand papering & knetting Really mixed paint
brushing priming for enamel.
11 Painting two coats (excluding priming coat) on New wood & wood
based surface with enamel paint to give an even shade & surface 100.03 88.45 S.M.
incl. cleaning of all dirt, dust & other foreign matter.
12 Painting two coats of enamel paint (Excluding priming coat) over
previously painted wall after removing entire surface with even
shade & surface after removing dirt, dust foreign matter etc.
comp.(M.R.)
13 Providing and applying Epoxy paint of approved make to concrete
surface for RCC ESR (inside the container) or any other structure
including clearing the surface by scrapping and air blowers to the
satisfaction of Engineer-in-charge necessary scaffolding etc. 100.00 97.00 S.M.
complete with all leads including necessary testing as per IS code.
For old surface - 2 coats
14 Writing letter or figures on any surface with black japan paint
(stops,comas, hyphens and the like not to be measured and paid for Per Letter
separately)(i) Block (Letters/Figures) (Per 10 Letter pet CM.HT) 100.00 3.18 Per
15 Writing letter or figures on any surface with black japan paint
Per Letter
(stops,comas, hyphens and the like not to be measured and paid for
separately) (ii) Indian (Letters/Figures)
16 Removing dry or oil bound distemper by a washing and scraping
and sand papering the wall surface smooth including necessary 100.00 11.30 S.M.
repairs to scratches complete.
DESCRIPTION OF ITEM QUANTITY RATE UNIT AMOUNT
17 Providing and supplying safety hanging net of appropriate capacity
/ dia. of rope and of suitable nylon quality which can withstand any
impact of human being etc. from the top of the tank and internal
and external periphery of ESR with necessary sufficient supporting
arrangement for. In short the arrangement should be such a way,
that the safety purpose shall be ensured with all respect during 2.00 89285.71 Job
construction period and the same can be taken back by contractor
after completion of the work duly concerned by Engineer in-
18 Taking photographs of work in progress and submit with each RA
bill. Photographs shall cover details of locations of the activity of
work in progress. The Contractor shall submit photographs with
Album in a set comprising 2 (two) copies (size of photograph is 4" 100.00 26.79 Set
x 6") and a soft copy of the same. Work shall be carried out as per
the instruction of the Engineer-in-charge
19 Cutting out cracks of wall or terrace to V section ,cleaningout,
grouting with cement and sand slurry 1:3 (1 cement : 3 sand ). at 0 65.23 RMT
any height
20 Crack Repairs:-Crack filling using fiber reinforced polymer modified
mortar after openning crack in "V" grove, Making Surface dust free,
with a bond coat of polymer as per the data sheet for crack
repairing cracks less than 8mm (market rate)
TOTAL AMOUNT (Rs.) :-
TOTAL AMOUNT (Rs.) :-
Hydraulic Engineer
Surat Municipal Corporatioin