Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC SHIVALIK PARK LANE NO 8 MEHERPUR SILCHAR CACHAR ASSAM 788015 | SILCHAR | CACHAR | ASSAM | 788015 | ₹1.9 L | L1 | Accepted-AOC L1 Agency |
| 2 | L2₹2.0 LRejected-Finance S M C ROAD GHUNGOOR SILCHAR DIST CACHAR ASSAM PIN 788014 | SILCHAR | CACHAR | ASSAM | 788014 | ₹2.0 L | L2 | Rejected-Finance Higher |
| 3 | L3₹2.3 LRejected-Finance | ₹2.3 L | L3 | Rejected-Finance Higher |
| 4 | L4₹2.4 LRejected-Finance VIVEKANANDA ROAD SILCHAR CACHAR ASSAM 788007 | SILCHAR | CACHAR | ASSAM | 788007 | ₹2.4 L | L4 | Rejected-Finance Higher |
Tender Value
₹3.1 L
Closing Date
24 Mar 2026, 2:00 pmClosed
Registrar NIT Silchar
Registrar NIT Silchar
Electrical wiring work for Aerodynamic and Hydrodynamic Research Facility of Mechanical Department at NIT Silchar.
2026_NS_902816_1
NIT/Estate/Limited/2025-26/15 Sl. No. 02 dt.17/03/2026
Limited
Electrical Works
NIT Silchar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
7 May 2026
18 Mar 2026
25 Mar 2026
18 Mar 2026
24 Mar 2026
18 Mar 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit/Cassing as required with necessary lugs where required.2 X 2.5 sq. mm + 1 X2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
6 pin 15/16 A socket outlet
Installation,testing and commisioning of prewired,fluorescent fitting /compact fluorescent fitting of all types,complete with all accessories and tube lamp etc directly on ceiling/wall,including connection with 1.5 sq mm FRLS PVC insulated copper conductor,single core cable and earthing etc. as required
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 A,36KA,FPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Triple pole and neutral
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) way (4 + 12), Double door
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct on wall surface with necessary clamps or in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
Supplying of following type and watt LED light including necessarry connection wires etc as required.a)18-20 Watt Batten light
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium f1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable as specified and directed by the deptt. ( Havells/ RPG/CCI/Polycab/ Finolex make)70q. mm.Three and half Core armoured U.G. cable
Supplying and fixing including connections of the Aluminium Lugs for following size of PVC insulated and PVC sheathed/XLPE Aluminium conductor cable of 1.1 KV grade as required.a) 70 Sqmm ,3.5 core
Providing, laying and fixing following dia G.I. pipe (medium class) in ground or wall surface complete with all fittings including necessary clamps etc as requireda)63 mm dia
Suppling and fixing of fan hook for installing ceilng fan
Supplying and fixing following Size, tin copper busbar as required.and as approved by the deptt. 200 Amps
Supplying and fixing following rating,Four pole, 440 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 Amps
Supplying and fixing following size/ modules, PVC box alongwith cover plate for modular switches etc. as required a)9Module
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and fixing following rating and pole, MCCB enclosure in the wall as directed and approved by the deptt 200 Amps four pole
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Termsconditions.pdf
Additional Documents • 1.15 MB
BOQ_948918.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid