Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹9.4 L Quoted ₹9.7 L | L1 | Accepted-AOC Acceptance |
| 2 | L2₹9.8 L+₹14,950 (1.54%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | ₹9.8 L+₹14,950 (1.54%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹10.4 L+₹73,570 (7.59%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹10.4 L+₹73,570 (7.59%) | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹10.6 L+₹88,102 (9.09%)Rejected-Finance | ₹10.6 L+₹88,102 (9.09%) | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | Rejected-Technical 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | - | - | Rejected-Technical Fail to Fulfilled eligible criteria as per NIT |
| Sl No | Description | Qty | Unit | M/s R K Enterprises L4 | SANJOLI CONSTRUCTION COMPANY L1 | Anil Builders L3 | Shri Electrical Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting HT/LT Connection before Repair /servicing and testing of distribution transformer at site of capacity 63 KVA to 3.15MVA installed on Plinth / Pole mounted structure by opening top cover & replacing unserviceable spares / components of transformer ,without lifting core assembely reassembling after repair & testing complete all as specified and directed by Engr-in-Charge.
Note:- (a) Rewinding of transformer HT/LT Coils shall be carried out from ISO certified 2008 Coy.
(b) Dehydration and filteration of transformer oil, and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule however cost of renewal of Nut, bolts & washers shall deemed to be included in the quoted rate. | 15 | EACH JOB | 3,735 ₹56,025 | 5,100 ₹76,500 | 3,700 ₹55,500 | 3,500 ₹52,500 Lowest |
| 2.00 | S&F breather for transformer of suitable size up to 63 to 400 KVA transformer complete all as specified and directed by Engineer-in-charge. | 2 | Each | 975 ₹1,950 | 900 ₹1,800 Lowest | 900 ₹1,800 Lowest | 1,000 ₹2,000 |
| 3.00 | S&F breather for transformer of suitable size for 1000 KVA transformer complete all as specified and directed by Engineer-in-charge. | 2 | Each | 1,352 ₹2,704 | 2,100 ₹4,200 | 927 ₹1,854 Lowest | 1,200 ₹2,400 |
| 4.00 | S&F breather for transformer of suitable size for 3.15 MVA transformer including taking out unserviceable breather complete all as specified and directed by Engineer-in-charge. | 2 | Each | 1,700 ₹3,400 | 3,000 ₹6,000 | 1,350 ₹2,700 Lowest | 1,500 ₹3,000 |
| 5.00 | M&L for copper earthing with copper earth Plate 60cm x 60cm x 3.15mm thick electrode and 20x3mm copper strip as earthing lead complete all as specified and directed by Engineer-in-charge. | 6 | Each | 17,300 ₹1,03,800 | 15,300 ₹91,800 | 15,300 ₹91,800 | 14,000 ₹84,000 Lowest |
| 6.00 | Dehydration/filtration of transformer oil by means of centrifugal filtration Machine to achieve the specified dielectric strength of not less than 50 KV/Min at 2.5 mm electrode gap in existing position of transformer of any capacity and transformer oil for topping up to required level all as directed by Engr-in-Charge
NOTE: (i) Contractor has to make his own arrangement for oil filtration machine/ plant.
(ii) Filtration shall be done at site when electricity supplies functional.
(iii) Test report for the same vetted by the authorized lab submitted by the contractor. | 8,000 | Ltrs | 13 ₹1,04,000 | 6.3 ₹50,400 Lowest | 12 ₹96,000 | 11 ₹88,000 |
| 7.00 | Supply & filling up of transformer oil at various substation conforming to IS -335 of 1993 as in top up / replacement up to desired level of transformer oil capacity complete all as specified and as directed.
Note: Dielectric strength of oil should not be less than 50-60 KV complete all as specified and directed. | 900 | Ltrs | 127 ₹1,14,300 | 120 ₹1,08,000 Lowest | 120 ₹1,08,000 Lowest | 125 ₹1,12,500 |
| 8.00 | Supply & Fix Four pole contactor 25 to 30 Amp including taking down old unserviceable contactor all as specified and directed by Engineer-in-charge. | 1 | Each | 1,800 ₹1,800 Lowest | 3,000 ₹3,000 | 1,850 ₹1,850 | 2,150 ₹2,150 |
| 9.00 | Supply & Fix Four pole contactor 35 to 40 Amp including taking down old unserviceable contactor all as specified and directed by Engineer-in-charge. | 1 | Each | 4,354 ₹4,354 | 3,600 ₹3,600 Lowest | 4,200 ₹4,200 | 4,000 ₹4,000 |
| 10.00 | M&L for replacement of defective/ cracked HT porcelain bushing (set of three) of suitable size for transformer any capacity complete all as specified and as directed by Engineer-in-charge. | 4 | Each Set | 1,010 ₹4,040 | 3,600 ₹14,400 | 1,000 ₹4,000 Lowest | 1,100 ₹4,400 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
1 Sept 2025, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LABORATORY JODHPUR
REPAIR/ MAINT OF POWER TRANSFORMER, DISTRIBUTION TRANSFORMER OF DIFFERENT CAPACITY AND OTHER CONNECTED WORKS AT DEFENCE LAB JODHPUR
2025_MES_725219_1
8679/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,000
Yes
17 Nov 2025
8 Aug 2025
3 Sept 2025
8 Aug 2025
1 Sept 2025
18 Aug 2025
9 Aug 2025 - 16 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .