Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.8 L+₹4.3 L (37.5%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹16.9 L+₹5.4 L (46.7%)Rejected-AOC | L3 | Rejected-AOC Not Lowest |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
20 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HILLS DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
SPL REPAIR OF CONTROL AND METERING SYSTEM AND SHIFTING OF CHANGE OVER SWITCH FROM MRS TO GENERATOR ROOM AT NHO UNDER GE CLEMENT TOWN DEHRADUN
2022_MES_543567_1
85371/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Clement Town
class E Cat b ii
9 documents required · 9 mandatory
₹500
GE Clement Town
₹32,000
Yes
23 Nov 2022
5 Aug 2022
27 Sept 2022
5 Aug 2022
20 Sept 2022
8 Sept 2022
5 Aug 2022 - 12 Aug 2022
90 days
Amount
Disconnecting & Taking out existing LT panel change over switch from MRS LT panel room and refixing, commissiong the same in genreator room including all nacessary fixing arrangement & connceting LT Cables with suitable legs/thimbles and earthwork and PCC as requied etc complete all as specified and directed.
Disconnceting and taking out existing LT cable of any size from site and re laying in duct all as specified.
Supply, laying, connecting and testing in repalcement XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 1100 Volts grade with stranded aluminium conductor cross sectional area 150 sqmm 3.5 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed.
Supply, laying, connecting and testing in repalcement XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 1100 Volts grade with stranded aluminium conductor cross sectional area 185 sqmm 3.5 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed.
NOTE: (i)Cost of all the material , components, repairs, elements as per above as well as other elements (except supply only of the components considerd under items herein after to the extent required and operated ) to make the VCB complete functional shall be deemed to be included in the quoted rate of the contractor.
(ii)Individual Breaker VCB consider as one unit and above job is to be carried out unitwise.Above job will be carried out by licenced technician as aproved by GE.
(iii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor.
(iv) All necessary tools & plants required for carried out above job will be provided by contractor and the cost of the same are deemed to be included in queoted rate.
(v) Inventory of defective parts to be replaced by contractor will be prepared by joint inspection of engr in charge with contractor
Supply and replacement &, install, testing and commissioning of cast resin current transformer suitable to 11KV indoor type Ratio 100-50 /1-1A ,VA:15 ,5P10/0.5 for Differential protection relay all as specified. Make: Crompton/Pragati/Kappa /AREVA/ABB/ Schnider/ Vishal ”
Supply only microprocessor based numeric feeder protection relay MC61CnX ( over current three nos and earth fault one no) high set testing,RS 485 port type including programming Make; L&T Cat no.MC61CNX4000 or equivalent in ABB /Simense for 11 KV HT panel incl taking down old u/s relay complete all as specified & directed.
Supply only Over Voltage or under voltage relay (20-110 V AC/DC) type for VCB 11 KV enclosure type incl taking out complete all as specified & directed.Make L&T Cat No.MV12AA10X00 or equivalent in ABB /Simense
Supply only Tripping coil alongwith plunger operating on 32 Volt DC for vcb trolly as per existing make and model..
Supply only Rotary switch as per existing make/model
Supply only Closing coil operating on 32 Volts DC for VCB trollyas per existing make and model...
Supply only Single phase circuit Spout RYB phase of as per existing make and model..
Supply only Single Phase bus bar spout for R and B phase of as per existing make and model..
Supply only Single Phase bus bar spout for Y phase of as per existing make and model..
Supply only Auxiliary switch as per existing make and model..
Supply only Limit switch as per existing make and model..
Supply only Auxiliary contactor as per existing make and model..
Supply only Tripping lever as per existing make and model.
Supply only Triping lever clutch as per existing make and model.
Supply only Buffer for opening spring as per existing make and model.
Supply installation testing & commissioning of Trivector Meter Class 0.5s, 3 phase, 4 w TVM 110volt (L-L) 5 amp incl making necessary electrical coneection etc., complete all as specified and directed by Engr-in-Charge. Make:- L&T/Schinder/Legrand.
Supply only oil temperature indicator meter range 0-120 0 C for 315 KVA ,630 KVA, 400KVA and 100 KVA,11 KV /433 V transformer including complete all as specified & directed.
M & L for applying two coats of synthetic enamel paint of approved quality / Shade by spray including preparation of existing old painted surface of feeder pillar box/LT panel complete all as specified and directed.
Repairing of Out door/ indoor type LT feeder pillar box such as replacement of hings , lock, welding of sheets front and back side fo pannel & fixing properly with suitable Neoprene rubber gasket complete all as specified and as directed by engr in charge.
S& F in repair LED indicating Lamp (for Incomers) suitable for 230/240 Volts AC supply complete with integral circuit & cluster LED of following colours : RED - YELLOW , BLUE - all as specified and as directed by engr in charge.
Supply only insulating transformer oil confirming to IS 335 1993 for replacing in power/distribution transformer with dielctric strength not less than 60 KV complete all as specified and directed.
M&L for Filteration/ dehydration and cleaning of transformer oil off line by dehydration plant including testing of samples before and after dehydration and filtration, dielctric strength should not less than 55 KV at 2.5 mm gap after dehydration/filtration all as specified and directed. Note:- For running of filtration plant the arrangement of electric supply / DG set should be made by contractor and the cost of same deemed to be include in quoted rate.
Supply only vaccume bottle suitable for 11 KV VCB of current rating 800 A of existing make /model all as spcified and directed .
Disconnecting all in coming and outgoing cables, removing the serviceable transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to nearby approved workshop, for carrying out maintenance of transformer all as specified in IS -10028 (part III) - 1981 following by Opening of transformer cover, draining out oil, de-tanking core and coil assembly,cleaning, washing of dust and dirt etc from all parts including core and tank, cooling tubes of radiators, re-assembling of core and winding after carring out necessary repair and replacement of defective items including providing all necessary insulation material of appropriate class including varnishing drying out in vacuum chamber till specified IR values are achieved, complete insulation varnishing to be done and providing new gasket, nuts , bolts, and checking of leakages if any,rectifying the same by welding, checking of tap change if found faulty, repair / replace the same etc, and reassembling of complete transformer all as directed by Engr-in-Charge , including testing as per relevant IS and transporting back the transformer after repair/maintenance to the site , install it, reconnect all the incoming and out going cables by properly using insulation tape and testing complete of following capacities.
(a) 630 KVA 11000/433 Volt Distribution transformer
(b) 400 KVA 11000/433 Volt Distribution transformer
(c) 315 KVA 11000/433 Volt Distribution transformer
(d) 100 KVA 11000/433 Volt Distribution transformer
Note - (i) Cost of items required to be replaced will be measured and paid seperately as under relievent items of this job. The labour charge for replacing the same are deemed to be included in the rates quoted. (ii) The cost of painting inside & outside of transformer also deemed to be included in the rates quoted. (As per IS -10028 (part III) - 1981.) (iii) The standby transformer will be provided by the contractor without any extra cost for continuous power supply, while carrying out repair of transformer. (iv) Any other items which is required to be provided for smooth functioning of transformer at the time of installation but not specified above shall be provided by contractor without any extra cost . The cost of the same are deemed to be included in the rates quoted. (v) The transformer will be get repair from approved manufacturer /workshop having licence for the same, The firm shall be got approval from GE.
Supply only silica gel breather assembly with fresh silica gel for 400 KVA to 630 KVA transformer complete all as specified and directed.
Supply only silica gel breather assembly with fresh silica gel for 100 KVA to 315 KVA transformer complete all as specified and directed.
S&F in repair of following items suitable for potential transformer 11 KV,AC ,3 Phase,50 HZ indoor type, including servicing of PT & replacement of T/F oil complete all as specified and directed
(a) Supply only fuse type bushing as per sample provided - 3 Nos
(b) Supply only fuse 11 kv, 3 Amps AVT type as per sample -3 Nos
Supply and replacement of MCCB with thermal magnetic protection unit 400A 4 Pole 415 volt 36 KA Thermal Adjustable-0.8 to 1xln,Magnetic Adjustable -5 to 10xln all as specified.
Supply and fixing MCCB with thermal magnetic protection unit 350A 4 Pole 415 volt 36 KA Thermal Adjustable-0.8 to 1xln,Magnetic Adjustable -5 to 10xln all as specified.
Supply and replacement of MCCB with thermal magnetic protection unit 200A 4 Pole 415 volt 25 KA Thermal Adjustable-0.8 to 1xln,Magnetic Adjustable -5 to 10xln all as specified.
Supply and replacement of MCCB with thermal magnetic protection unit 160A 4 Pole 415 volt 25 KA Thermal Adjustable-0.8 to 1xln,Magnetic Adjustable -5 to 10xln all as specified.
M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below NGL) with top edge of the plate not less than 1.5 Mtr deep below NGL, connected by galvanised iron strip 32x6mm as earth lead by means of brass nuts and bolts, thimbles, cheak nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx 300mm, 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcol etc all as shown in electric plate No-3 of MES SSR Part-I(2009) as specified including and provision of GI strip 7.50 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade , including all excavation and earth work and connecting the earth strip toan earthing test point/panel including testing on completion complete all as specified and directed by Engr-in-Charge. Note :-(i) RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM weight not less than 4 Kg/sqm in lieu of CI cover. (ii) Cost of additional strip more than 7.50 mtr will be measured and paid seprately under relevant item.
Supply, installation, commissioning and testing in repacement of HT 11 KV outdoor type gang operated triple pole air break switch suitable for Horizontal or vertical mounting fixed type complete with 12 insulator 200 amps rating and steel frame mechanically oprated mechanism consisting of operating rod of 25 mm bore light grade GI pipe of sutable length worked from ground level and with locking arrangement flat iron clamp 50 mmx6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed. Make:- JAIPURIA BROTHERS, Pactel, Atlas, ECE, Areva
Supply, installation, testing and commissioning as in repair of Lighting Arresters Metal oxide type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 12 KV/10KA with and including lighting counter and cable of sutable size and core from lightning arrestor to ligting counter complete all as specified & directed. Make :-Jaipuriya Brothers/Crompton/GEC/BHEL/ATLAS
S&F in replacement cable jointing kit 11 KV (earthed ) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
All as per item No 43 above but indoor type of size 95 Sqmm.
M & L in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc as required with32x6 mm GI strip complete all as specified and directed.
Supply, laying, connecting and testing XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 11000 Volts grade with stranded aluminium conductor cross sectional area 95 sqmm 3 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying GI tubing for connect to near by pipe line or laying underground cable and GI tubing (where provide for protection of cable) and getting out trimming the sides,forming bottom surface to required level in any type of soil complete etc all as specified and directed
M&L for sand cushioning for under ground cable with layer of fine dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trench complete all as specified and as directed.Note: Punned (consolidated) thickness of sand will be measured and paid.
Supply and laying , nominal size of traditional / conventional burnt bricks sub class "B" as cable cover, flat, of size 230mmX 114mmX 76mm , complete all as specified & as directed.
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed.
M&L for PCC/Road cutting for laying of pipe/cable exceeding 500 sqm & not exceeding 1000 sqm in cross sectional area and making good with PCC1:2:4 type B-1 using 20 mm graded stone aggeagete,complete all as specified.
TRINITY CONSTRUCTION
M/s Ram Chander Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .