Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC KUMMAMKULAM HOUSE KADAVANTHRA KOCHI 682 020 | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹26.0 L+₹59,367.50 (2.34%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹27.0 L+₹1.6 L (6.43%)Rejected-AOC CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹27.7 L+₹2.4 L (9.39%)Rejected-AOC 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹27.9 L+₹2.6 L (10.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
5 Feb 2024, 6:00 pmClosed
Shri DC Sharma IDSE CWE(NW) Kochi
CWE(NW) Kochi
PROVN OF APPROACH ROAD FROM VEMBANAD GATE TO TRAVANCORE GATE ALONG PERIMETER WALL AT NB(K)
2024_MES_636433_1
CWE(NW)KOCHI/81420
Open Tender
Civil Works
Item Rate
180 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹500
GE(NW) Kochi
₹64,000
Yes
11 Mar 2024
8 Jan 2024
7 Feb 2024
8 Jan 2024
5 Feb 2024
22 Jan 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/ loose soil complete all as specified and directed. Note:- Surplus excavated material after completion of job shall be removed by the contractor to a distance n.exc 100m, depositing spread & leveled to the thickness & gradient as direct by Engr-in-Charge.
M&L for 100mm hardcore of gauge n exc. 63mm broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for75mm PCC 1:4:8 Type D-2 using 40 mm graded stone aggregate as in Sub base flooring complete all as specified and directed.
M&L for Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm on existing hard standing spreading and levelling in layers n exc. 25 cm thick incl well ramming including watering as required complete all as specified and directed.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed.
All items as per 5 but for removing and refixing the existing paver blocks after levelling the surface by coarse aggregate complete all as specified and directed. Note:- Dismantled tiles shall be stacked at a distance n.exc 50m as directed, for reuse. The existing cushioning for paver block shall be loosened, leveled & compacted to the gradient as directed by Engr-in-Charge. Any extra cushioning material required to achieve & maintain desired level & gradient shall be provided by the contractor. Quoted rate shall be deemed to be inclusive of above provisions & nothing extra shall be paid on this account.
M&L for providing cement concrete Type B0, 1:2:4 (using 12.5mm graded aggregate) as in kerb including weathering, slightly rounded or chamfered angles and throating complete including necessary form work all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose soil complete all as specified and directed. Note:- Surplus excavated material after completion of job shall be removed by the contractor to a distance n.exc 100m, depositing spread & leveled to the thickness & gradient as direct by Engr-in-Charge.
M&L for PCC 1:4:8 Type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L Pre Cast cement concrete block masonry 1:3:6 with solid blocks, exc. 10cm in width and setting in CM 1:6 complete all as specified and directed.
M&L for 15mm thick rendering on brick or concrete wall surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed.
M & L for preparation of new plastered external wall surface and applying two coats of weather proof paint (Apex Ultima protek)or equivalent in the list of make over a priming coat as per manufacture's instruction complete all as specified and as directed by the Engineer-In-Charge.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Returning , filling in including spreding, leveling, watering & well ramming in layers n.exc 25cm thick in soft loose soil
Removing excavated material and deposting where directed at a level exc 250 mts to 500 mts and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
T K BUILDERS
Classic Builders
Anaswara Constructions
JESWIN BUILDERS
Ashbel Engineering Enterprises
M/s Antony Kallarakkal
M/s Reena Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .