| 1 | L1₹29.5 LAccepted-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹30.8 L+₹1.3 L (4.43%)Rejected-AOC | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹31.6 L+₹2.1 L (7.05%)Rejected-AOC 292 KRISHNA COLONY OLD HAMIDA SAHARANPUR ROAD YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹35.7 L+₹6.2 L (21.1%)Rejected-AOC | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹35.9 L+₹6.4 L (21.7%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Jul 2023, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/ replacement of internal Electrification at Garhi Cantt and Beacher Road under AGE E/M-II under GE Dehradun.
2023_MES_603098_1
8625/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D cat b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹90,000
Yes
29 Aug 2023
13 Jun 2023
13 Jul 2023
13 Jun 2023
11 Jul 2023
27 Jun 2023
Amount
Taking down carefully copper /aluminium point wiring (light, fan , socket or power) complete, fittings such as switches, ceiling roses, pendants, regulators sockets light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls/floors and reuse the serviceable fittings under respective items complete all as specified and directed. Note :- (i) The contractor/Supervisor collect the complaints from the JE/MCM through JOB Card and rectify the complaints. (ii) The contractor/Supervisor should submit the Job Card duly signed by the user. (iii) RAR/Final bill will be paid only after verifying of workdone by the Engr-in-Charge
Material and labour point wiring with 3 runs of 1.5 Sqmm (colour code as per IE Rules) FRLS, PVC insulated, unsheathed, single core, 1100 Volts grade, multistranded copper conductor cable/Wire in and including concealed rigid PVC conduit medium grade and green wire connected to common earth dolly, and including 1.6mm thick cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylum sheet cover fixed with brass screw complete with all accessories for one light point/Fan point controlled by one ,one way switch complete all as specified and directed..
All as per Item No 2 here-in- before but one 3 pin 5 Amps socket out let on the same board with other switches complete all as specified and directed.
All as per Item No 2 here-in- before but one 3 pin 5 Amps switch socket out let on the independent board with other switches complete all as specified and directed.
All as per Item No 2 here-in- before but One bell/buzzer point controlled by bell push complete all as specified .
All as per Item No 2 here-in- before but One light point controlled with switch 2 way complete all as specified.
All as per Item No 2 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 4 sq mm PVC insulated FRLS copper conductor complete all as specified and directed.
All as per Item No 2 here-in- before but wiring drawing through Surface PVC conduit complete all as specified and directed.
All as per Item No 8 here-in- before but one three pin 5 Amps socket out let on the same board with other switches complete all as specified and directed.
All as per Item No 8 here-in- before but one three pin 5 Amps switch socket out let on the independent board with other switches complete all as specified and directed.
All as per Item No 8 here-in- before but One bell/buzzer point controlled by bell push complete all as specified .
All as per Item No 8 here-in- before but One light point controlled with switch 2 way complete all as specified.
All as per Item No 8 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 4 sq mm PVC insulated FRLS copper conductor complete all as specified and directed.
All as per Item No 2 here-in- before but wiring drawing through exisitng conduit complete all as specified and directed.
All as per Item No 14 here-in- before but one three pin 5 Amps socket out let on the same board with other switches complete all as specified and directed.
All as per Item No 14 here-in- before but one three pin 5 Amps switch socket out let on the independent board with other switches complete all as specified and directed.
All as per Item No 14 here-in- before but One bell/buzzer point controlled by bell push complete all as specified .
All as per Item No 14 here-in- before but one two way point controlled with switch 2 way complete all as specified.
All as per Item No 14 here-in- before but one three pin 15 Amps switch socket out let on the independent board with 4 sq mm PVC insulated FRLS copper conductor complete all as specified and directed.
All as per Item No 2 here-in- before but wiring drawing through Case & Caping complete all as specified and directed.
All as per Item No 20 here-in- before but one three pin 5 Amps socket out let on the same board with other switches complete all as specified and directed.
All as per Item No 20 mentioned here-in- before but one three pin 5 Amps switch socket out let on the independent board with other switches complete all as specified and directed.
All as per Item No 20 mentioned here-in- before but One bell/buzzer point controlled by bell push complete all as specified .
All as per Item No 20 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 4 sq mm PVC insulated FRLS copper conductor complete all as specified and directed.
Supply and fix in repair Switch piano flush type single pole one way 230 Volts 6 Amp complete all as directed.
Supply and fix in repair Switch piano flush type single pole two way 230 Volts 6 Amp complete all as directed.
Supply and fix in repair Socket outlet 3 pin , 230 Volts 5/6 Amps multipurpose 5 pin complete all as specified and directed.
Supply and fix in repair bell push flush type 5 Amps 230 Volts single pole complete all as specified and directed.
Supply and fix in repair Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type IS: 1239-1988 marked with valid CML No complete all as specified.
Supply and fix in repair switch piano flush type, single pole, one way, 230 Volts 15/16 Amps marked with valid CML No. complete all as specified
Supply and fix in repair anglurar Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix in repair stepped type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts, 6 Amps 120 watts .
S &F in repair ceiling rose, three terminal surface bakelite suitable for batten fitting complete all as specified
Supply and fix in repair calling bell type AC 230 Volt single pole complete all as specified and directed.
Supply and fix Modular white cover plate with frame 2 module and metal flush box 2 module complete all as specified and as directed.
All as per item No 35 here in before but 3 module complete all as specified and directed.
All as per item No 35 here in before but 4 module complete all as specified and directed.
All as per item No 35 here in before but 6 module complete all as specified and directed.
All as per item No 35 here in before but 8 module complete all as specified and directed.
All as per item No 35 here in before but 12 module complete all as specified and directed.
Supply and fix in repair Modular switch 1 way 06 amp single pole complete all as specified and directed.
Supply and fix Modular switch 2 way 06 amp single pole complete all as specified and directed.
Supply and fix in repair Modular switch 1 way 16 amp single pole complete all as specified and directed.
Supply and fix in repair modular socket outlet 6/16A- 5 pin combined of 02 module complete all as specified and directed.
Supply and fix in repair modular socket outlet 6A-5 pin combined of 02 module complete all as specified and directed.
S & in repair moduar bell push 6 Amp 1 module complete all as specified and directed.
Supply and fix in repair modular fan step regulator 120 W-2 module complete all as specified and directed.
Supply and fix in repair LED tube light fitting batten type all in one single phase 18/20 W with lamp 6500/4000 K complete pre-wired all accessories complete all as specified and directed.
Supply and fix in repair mirror light decorative compact luminaries with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repair decorative wall mounting made out of polycarbonated suitable for and incl retrofit 9 watts LED bulb complete all as specified.
Supply and fix LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with IP 65/66 protection complete including bracket made out of 32 mm bore medium grade GI pipe made to shape with bolts, buts & washers of min 1.2 Mtr incl grouting of nuts or fasteners clamps and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified incl taking out old u/s fitting complete. Note: The unit rate include for painting to bracket with one coat of red oxide paint and two coat of alluminium paint before fixing.
Material and labour for submain wiring with 3 runs(N+P+E) of 1.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed/surface PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-3 runs of 1.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 52 here-in-before but with 3 runs(N+P+E) of 2.5 Sqmm single core copper FRLS conductor . Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length complete all as specified and directed.
All as per item No 52 here-in-before but with 3 runs(N+P+E) of 4 Sqmm single core copper FRLS conductor .Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length complete all as specified and directed.
All as per item No 52 here-in-before but with 6 runs(3 runs P+N+ 2 run Earth) of 6 Sqmm single core copper FRLS conductor and PVC conduit not less than 24 mm dia. Note:-6 runs of 6 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length complete all as specified and directed.
Material and labour for replacement of old rusted sunken box with new 1.6mm thick cadmium plated sunk MS pressed steel terminal boxes with 3.0 mm thick hylum sheet cover fixed with brass screw complete with all accessories and making the good disturbed surface with plastering and white washing etc incl taking downcomplete all as specified and directed .
M& L for replacement of old u/s hylum sheet cover fixed with brass screw complete with all accessories and making the good disturbed surface with plastering and white washing etc incl taking downcomplete all as specified and directed .
Supply and fix in repair Distribution board VTPN 4 Way double door, suitable for MCCB 63/100 Amps MCCB as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection incl taking out old u/s complete. Note:- DB and MCCB/MCB shall be of same make
Supply and fix in repair MCCB 415 Volts, 63 Amps, rating 4 Pole , all as specified and directed
Supply and fix in repair MCCB 415 Volts, 100 Amps, rating 4 Poleall as specified and directed
Supply and fix in repair Distribution board SPN 8 Way double door, for mounting MCBs isolator, IP 43 protection. Note:- DB and MCCB/MCB shall be of same make.
Supply and fix in replacement MCB combo box with steel enclosure with one single pole MCB 20 Amp 10 KA C series suitable for AC/geyser etc complete all as specrified & directed.
Supply and fix in repair 415V 10KA 'B' curve MCB of TPN 40 to 100 Amps complete all as specified and directed.
Supply and fix in repair SP 6 to 32 Amps rating 240V, 10KA 'B' curve MCB complete all as specified and directed.
Supply and fix in repair SPN 25 to 63 Amps rating 240V, 10KA 'B' curve MCB complete all as specified and directed.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC (1:3:6) type C1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm TMT bar 100 c/c both ways complete all as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed. Note: (i) If the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr shall be deemed to be included in the rate quoted for this item.
Supply and fix in replacement tamper proof single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including cable connection, proper sealing with barcode with PVC seal. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note:- Old unserviceable meter will be deposited to E/M store yard)
PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
All as per item No 68 here-in-before but of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
All as per item No 68 here-in-before but of size of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed.
All as per item No 68 here-in-before but of size of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed.
All as per item No 68 here-in-before but of size of size 350 mm x 300 mm and 50 mm deep complete all as specified and directed.
M/S Ex Soldiers Mechanical Works
M/S Durvish Mourya
Balraj and Co
M/s Pradeep Kumar
M/s Anamika Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .