Loading…
Loading…
Tender Value
₹10.0 Cr
EMD Value
₹10.0 L
Closing Date
6 Apr 2026, 6:00 pmClosed
Assistant Manager (South West Zone)
Construction Of Women Skill Development Center at F.P.No. 06+109, T.P.S.No. 26 ( Makarba) + 25 (Vejalpur Sarkhej, Ward, South West Zone, Ahmedabad.
287129
20/2025-26
Open
Civil Works - Buildings
Ahmedabad
3 documents required · 3 mandatory
₹18,000
Municipal Commissioner, Ahmedabad
₹10.0 L
17 Mar 2026
17 Mar 2026
17 Mar 2026
6 Apr 2026
17 Mar 2026
Name of Work : Construction Of Women Skill Development Center at F.P.No. 06+109,
T.P.S.No. 26 (Vejalpur) In Sarkhej Ward, South West Zone, Ahmedabad.
Bill of Quantities
Sr. No. Qty Unit Rate Per Amount
Civil Work Estimate
1 Demolition & Dismantling work
Demolition of RCC work using Hydra
Breacker including stacking of servicable
materials and disposal of unservicable
materials with all lead and lift.Removal Of
Existing Building Foundation and Super
Structure If Any.
Demolition of Brick work and stone masonry
including stacking of serviceable materials
and disposal of unserviceable materials with
all lead and lift.(ii) In Cement Mortar.Removal
Of Existing Building Foundation and Super
Structure If Any.
Dismentaling of sheet roofing including ridges,
c Hips, Valleys, Gutters etc. stacking of
serviceable materials and disposal of
unserviceable materials with all lead and lift.
i 5.00 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5.00 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including distempering
d 1000.00 and stacking the materials with all lead and 3.63 Kg.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
e 2.00 architraves, hold fasts and other attachment 185.85 Each
etc. complete and stacking them with in all
lead and lift. (i)Notexceeding 3 Sq.M. in area.
Removing & Scrapping of Old deteriorated
Plaster of any thickness from Masonary /
R.C.C. member including stacking of
serviceable material & disposal of un
serviceable from site of work with all lead &
Dismentaling any type tiled of stone floors laid
g 45.00 in mortar including stacking of serviceable 47.25 Sq.M.
materilas and disposal of unserviceable
materials with all lead and lift.
Excavation for foundation including sorting
2 out stacking of useful material & disposing of
excavated stuff upto 50 mt. lead. Loose & Soft
soil.Excexuted With Mechanical Effort
a 2526.00 up to 1.5 mt. depth 115.92 Cu.M.
c 3025.00 3.0 to 5.0 mt. depth 141.11 Cu.M.
d 1154.00 above 5.00 mt. depth 162.02 Cu.M.
e 500.00 Add extra for Disposing off the excavated stuff 17.28 Cu.M.
of above items for lead of (A) 50 m to 100 m
f 2000.00 Add extra for Disposing off the excavated stuff 34.56 Cu.M.
of above items for lead of (B) 100 m to 200 m
g 500.00 Add extra for Disposing off the excavated stuff 51.84 Cu.M.
of above items for lead of (C) 200 m to 300 m
h 500.00 Add extra for Disposing off the excavated stuff 76.80 Cu.M.
of above items for lead of (D) 300 m to 400 m
i 500.00 Add extra for Disposing off the excavated stuff 128.00 Cu.M.
of above items for lead of (E) 400 m to 500 m
Providing and installing cast in situ single
under reamed piles of specified diameter and
length below pile cap, excluding the cost of
Concrete, steel reinforcement but including
j the cost of boring with bentonite solution and
the length of the pile to be embedded in pile
cap etc. all complete. (Length of pile for
payment shall be measured upto to the
bottom of pile cap) :
i 10.00 400 mm dia. Piles 638.83 Rmt.
ii 20.00 450 mm dia. Piles 705.03 Rmt.
Extra over single under ream for providing
additional bulbs in under reamed piles, under
k specified diameter excluding the cost of
Concrete, steel reinforcement (only the nos.
of extra bulbs are to be paid).
t 1.00 400 mm dia. Piles 813.05 Each
ii 2.00 450 mm dia. Piles 1103.43 Each
Provdg. & laying cement concrete 1:5:10 (1
cement : 5 course sand : 10 hand broken
3a 1.00 aggregates 40 mm nominal size) and curing 2492.51 Cu.M.
complete, excluding cost of form work in
foundation & Plinth.
Provdg. & laying cement concrete 1:3:6 (1
3b cement : 3 coarse sand : 6 hand broken stone
aggregates 40 mm nominal size) and curing
complete excluding cost of form work in
415.00 (A) Foundation and plinth 2976.00 Cu.M.
3c 194.00 Supplying of graded hand brocken stone size 983.93 Cu.M.
of 90 mm to 127 mm at site (Rubble or Spoul)
Labour charges for spreading the spouls
mm to 127 mm thick layer good earth filling in
voids correcting the grade & camber comp.
with rolling, watering, incl. preparing
thesurface by brushing for removing all loose
or dirts ect.comp.
Provdg. & laying cement concrete 1:4:8 (1
cement : 4 coarse sand : 8 hand broken stone
4 2.00 aggregates 40 mm nominal size) and curing 2653.67 Cu.M.
complete excluding cost of form work in
foundation& plinth.
Filling available excavated earth (excluding
rock) in trenches, plinth, sides of foundations
5 2500.00 etc. in layers not exceeding 20 cm. in depth 129.10 Cu.M.
consolidation each deposited layer by
ramming and watering.
Conveyance charges of earth lime, murrum,
6 building rubbish, manure, garbage, sludge,
excavated rock, fly ash, aggregate of any kind
a 500.00 Conveyance charges upto 1 km 320.20 Cmt
b 500.00 Conveyance charges upto 2 km 347.73 Cmt
c 10000.00 Conveyance charges upto 5 km 408.41 Cmt
d 10000.00 Extra For Lead on Above Item Above 5 km & 9.26 Cmt
e 10000.00 Extra For Lead on Above Item Above 6 km & 9.26 Cmt
f 10000.00 Extra For Lead on Above Item Above 7 km & 9.26 Cmt
g 10000.00 Extra For Lead on Above Item Above 8 km & 9.26 Cmt
h 10000.00 Extra For Lead on Above Item Above 9 km 9.26 Cmt
Filling in plinth with sand under floors
7a 15.00 including watering, ramming, consolidating, 455.63 Cu.M.
compacting and dressing etc. completed.
Filling in foundation and plinth with murrum or
7b 150.00 selected soil in layers of 20 cm. thickness 286.20 Cmt
including watering, ramming and
consolidating etc. Complete.
Brick work using common burnt clay building
8 bricks having crushing strength not less than
35 kg/Sq. cm. in cement mortar 1:6 (1 cement
: 6 fine sand) conventional brick
a 101.00 (a) in foundation & Plinth 3981.21 Cu.M.
b 221.00 Super structure Upto Floor Two Level 4253.46 Cu.M.
c 406.00 Super structure Above Floor Two Level 4293.55 Cu.M.
I.Half brick masonry in common burnt clay
building bricks having crushing strength note
9 less than 35 Kg/Sq. Cm. in cement mortar 1:4
(1 cement : 4 coarse sand) using conventional
brick in Super structure upto floor Four level
a 503.00 All Floor Level 646.70 Sq.M.
Providing and laying controlled cement
concrete of M-25 Grade and curing complete,
10.1 Excluding the cost of form work, Scaffolding,
cost of reinforcement for reinforced concrete
work For any Height up to any FloorLevel.
a 19.00 Foundations,Raft,Footings,Mass concrete 4238.04 Cu.M.
b1 2.00 RCC Retaining wall at All Floor 4519.88 Cu.M.
Tie-Beam, Lintel , Beam- Bracket, Stair Case
c1 13.00 & Landing, Coping ,Slab, balcony, weather 4496.07 Cu.M.
shed, loft , any cantilever etc All Floor
d1 10.00 Columns,Pillars, posts and struts at All Floor 4593.91 Cu.M.
Providing and laying controlled cement
concrete of M-20 Grade and curing complete,
10.2 Excluding the cost of form work, Scaffolding,
cost of reinforcement for reinforced concrete
work For any Height up to Floor Four Level.
a 5.00 Foundations,Raft,Footings,Mass concrete 3977.88 Cu.M.
Tie Beam , Lintel , Beam- Bracket , Coping
b1 73.00 ,landing, Slab, balcony, weather shed, loft , 4460.36 Cu.M.
any cantilever etc at All Floor
c1 2.00 Column at All Floor 4558.20 Cu.M.
d1 1.00 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready Mixed
M250 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to
site of work in transit mixer for all lead having
continuous agitated mixer, manufactured as
per mix design of specified grade for
reinforced cement concrete work including
10.3 2789.00 pumping of R.M.C. from transit mixer to site of 4853.56 Cu.M.
laying with all lead and lift, excluding the cost
of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and
durability as per direction of the Engineer - in
charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained)
(Cement level 450 kg )
Providing and laying in position Ready Mixed
M200 grade concrete for reinforced cement
conctere work , using cement content as per
approved Design Mix manufactured in fully
automatic batching plant and transported to
site of work in transit mixer for all lead having
continuous agitated mixer, manufactured as
per mix design of specified grade for
reinforced cement concrete work including
10.4 3.00 pumping of R.M.C. from transit mixer to site of 4793.10 Cu.M.
laying with all lead and lift, excluding the cost
of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve
workability without impairing strength and
durability as per direction of the Engineer - in
charge. Without Fly Ash (Min cement level as
per latest IS 456 shall be maintained)
(Cement level 400 kg )
Drilling suitable holes in reinforced or plain
cement concrete with power driven drill
machine to a minimum depth of 80mm upto
250mm in RCC beams, lintels, columns and
slabs to introduce steel bars for
sunshades/balconies including fixing the steel
bars in position using Hilti Chemical HY200-R
but excluding the cost of reinforcement, all
complete as per direction of Engineer-In-
8 mm Dia in 80 mm Deep & 12 mm Dia
b 960.00 10 mm Dia in 100 mm Deep & 14 mm Dia 263.66 Each
c 960.00 12 mm Dia in 120 mm Deep & 16 mm Dia 343.80 Each
d 80.00 16 mm Dia in 160 mm Deep & 20 mm Dia 608.63 Each
e 35.00 20 mm Dia in 200 mm Deep & 25 mm Dia 1024.44 Each
f 15.00 25 mm Dia in 250 mm Deep & 32 mm Dia 1938.54 Each
Providing and laying controlled cement
concrete 1:2:4( 1cement : 2 coarse sand :
Graded stone aggregate 20 mm nominal size
) and curing complete, Excluding the cost of
form work and reinforcement for reinforced
concrete work in:
a 1.00 Foundations, footings, base of 3923.53 Cu.M.
columns,grade slab and mass concrete.
slab, landing shelves, Balconies, lintels,
b 1.00 beams, girders, and cantilever, up to aany 4012.47 Cu.M.
P/A Trimix with dewatering machine and
floater machine on constructed R.C.C. work
incl. cost of machine and labour etc. comp. as
Making 15 mm Groove in R.C.C work on road
d 950.00 and filling it with poly sulfied selant and 30.00 Rmt
finished it good incl. all labour charges etc.
comp. as directed
Providing and laying and fixing 25 mm thick
expansion joint by hydrocell semi rigid UV
e 9.00 resistance with high performance laminated 738.13 Sqmt
closed cell polythene foam joint filler in sheet
foam as directed, etc. complete.
Providing form work in ordinary timber
planking so as to give a rough finish including
centering, shuttering, strutting and propping
12 etc. height of propping and centering below
supporting floor to celling not exceeding 4 M
& removal of the same for in situ reinforced or
plain concrete work in
a 799.00 (A) Foundation, footings, bases of columns 171.68 Smt
etc. and mass concrete.
b 4679.00 (B) Flat surface such as soffits of slabs, 252.00 Smt
landing and the like
c 3089.00 (C) Vertical surfaces such as walls (any 229.95 Smt
thickness) partitions.
(D) Columns, pillars, posts & struts.
d 2610.00 (1) Square, rectangular, polygonal in plan 297.68 Smt
e 20.00 (2) Circular or curved in plan. 422.10 Smt
(H) (1) Sides and soffits of beam, haunchings
f 5608.00 cantilevers, girders, bressumers, Coping and 192.15 Smt
lintels not exceeding 1 M in depth.
(2) Sides and soffits of beam, haunchings
g 10.00 cantilevers, girders, bressumers and lintels 259.88 Smt
exceeding 1 M in depth.
h 250.00 (L) chullah hoops, weather sheds, chhajas, 155.78 Smt
carbels etc including edges.
i 250.00 (M) Staircase with-sloping or stepped soffits 242.55 Smt
incl. risers & strings excluding landing.
Extra for additional height of propping and
centering where the height of propping and
j 800.00 centering exceeds 4 .O M between supporting 386.48 Smt
floor to ceiling including temporary brick or
stone pillars for supporting as required.
(i)Height more than 4.0 M.and upto 5.0 M.
Extra for additional height of propping and
centering where the height of propping and
k 150.00 centering exceeds 4 .O M between supporting 573.30 Smt
floor to ceiling including temporary brick or
stone pillars for supporting as required.
(i)Height more than 6.0 M.and upto 7.0 M.
Providing T.M.T Fe 500D bar reinforcement
13 for R.C.C. work including bending, binding
and placing in position complete up to any
a 335260.00 All Floor Level 75.46 Kg.
Providing and laying polished Kota stone slab
(Polished / River Finish, Green colour )
flooring over 20 mm. (average) thick base of
14 170.00 cement mortar 1:6 (1 cement : 6 coarse sand) 982.83 Sq.M.
or lime mortar 1:1.5 laid over and joined with
grey cement slurry including rubbing and
polishing complete.25 mm th.
Providing and laying polished Kota stone slab
25 mm. thick in Platform ,Riser of Stair
Skirting, Tread , dado and pillars laid on
15 133.00 mm. thick cement mortar 1:3 (1 cement : 3 1176.03 Sq.M.
coarse sand) jointed with grey cement slurry
including rubbing and polishing and MAking
groove where it is Required etc. compl
Providing and laying white/Colur glazed tiles
mm thick in flooring treads of steps and
16 5.00 landing laid on a bed of 12 mm thick cement 908.17 Sq. M.
mortar 1:3 (1 cement : 3 coarse sand) finished
with flush pointing in white cement.
Providing and layingWhite / Colour glazed
tiles of size 600 mmx300mm x 8 mm /
17 274.00 mmx 450mm x 8 mm in skirting, risers of 1426.95 Sq. M.
steps, Floor and dedo on 10 mm. thick
cement plaster 1:3 (1 cement : 3 coarse sand)
and jointed with white cement slurry.
Providing and laying marble stone slab
flooring over 20 mm. (Average) base of
18 2.00 cement mortar 1:6 (1 cement: 6 coarse sand) 2194.63 Sq. M.
or L.M. 1:1.5 laid and jointed with grey cement
slurry including rubbing and polishing
complete: (A) Marble slab 25 mm. thick.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in flooring treads of steps and
19a 2835.00 landing laid on a bed of 12mm thick cement 1062.50 Sq. M.
mortar 1:3 (1-cement : 3-coarse sand)
finishing with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm
thick , 24'' x 24'' in skrting risers of steps and
19b 891.00 dedo on 10mm thick cement plaster 1:3 1130.15 Sq. M.
(1cement : 3-coarse sand) and jointed with
white cement slurry
P & L 24" x 24" vitrified 8 mm thick tile flooring
20 mm (average) base of cement mortar 1:6 (
1cement: 6 coarse sand) on new surface or
fixing on existing flooring by adhesive material
including dismentaling of existing flooring and
jointed with color cement slurry including
finised with flush pointing & cleaning the
surface etc. complete for Antiskid
Providing and laying Ceramics tiles 6 to
mm thick in flooring, treads of steps, landing
20 5.00 and dedo on 12 mm. thick cement plaster 1:3 960.47 Sq. M.
(1 cement : 3 coarse sand) and jointed with
white cement slurry.
Providing & Laying 18 mm thick Mirror polish
granite For flooring , counter , stair -riser
tread , skirting , dedo , Jambs etc. machine
cut or chiselled on bed of cement mortar 1:1
pointing with neat cement slurry incl.
moulding, Making grooves where it is required
etc. comp. as per instruction of engineer in
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat on fair side of brick /
22a concrete walls for interior plastering upto any
Floor level and finished even and smooth in
i 4876.00 All Floor Level 190.58 Sq.M.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat plastering on ceilings,
b Beam side and sofits of stairs upto any Floor
level and finished even and smooth in
i 5015.00 All Floor Level 215.15 Sq.M.
Providing & fixing 23 cm wide chicken mesh
c 115.00 jali with nails & then application of 15 mm 292.59 Sq.mt
plaster on R.C.C. & masonary joints as per
dir. of engg. In charge.
Providing and mixing water proofing materials Per Bag
in cement mortar in proportion recommended of 50 Kg
by the manufacturer. etc. comp. as per of
instruction of engineer in charge. Cement
Providing 20 mm th. Double coat Sand face /
Mala Cement Plaster on Walls upto any
23a 2940.00 Height Above Ground level consisting of 12 297.68 Sq.M.
mm th. Backing coat of C.M. 1:3 ( 1 cement :
3 Ssand ) & 8 mm th. Finishing coat of C.M.
1:1 ( 1 cement : 1 sand ) ets. Complete.
White / Color washing with lime on
undecorated wall surfaces (two coats) to give
24a 50.00 an even shade including thoroughly brooming 12.29 Sq.M.
the surface to remove all dirt, dust mortar
drops and other foreign matter.
Providing & Applying 3 mm thick External
Wall Rustic Type Texture as per Design &
24b 2400.00 Make as Approved by Consultants / 424.92 Sq.M.
Engineer in Charge. Work Includes All
Necessary Scaffolding Work upto Any Height.
Finishing walls with Acrylic Smooth exterior
paint of required shade :New work (Two or
24 c 2800.00 more coat applied @ 1.67 ltr/10 sqm over and 174.97 Sq.M.
including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
P./L. METALIC HERITAGE SURFACE
Providing and fixing of HERITAGE textured
homogeneous wall finishing system from
BAKELITE HYLAM LTD or equivalent make
consisting of a two component system of (25
kgs per Pack) made of 92% silica particles
coated with fade resistant pigments, 100%
acrylic polymer bonding agent (5kgs per pack)
with the applied thickness of the coating being
between 0.8mm-1.2mm to be applied on
acured, smooth level plaster without keying,
as per the shades/combinations approved, as
per the manufacturer directions, for usages,
tobe applied by an approved applicator of the
manufacturer, as per the directions /
supervision of the engineers in charge, all
complete. Includes All Necessary Scaffolding
Work upto Any Height.
Providing and Fixing 18 mm thick concrete
base exposed brick cladding including surface
24e 240.00 waterproffing, polymer modified tile adhesive 3574.35 Sq.M.
and polymer modifies tile grout ( grey / white)
with neccesary scafolding etc compl. As per
direction of engg. Incharge.
Wall Painting (two coats) with plastic emulsion
/ Oil paint of approved brand and manufacture
and of shade required on undecorated wall
surfaces to give an even shade, over and
25a 8700.00 including a priming coat with alkali resistance 78.44 Sq.M.
primer of approved brand and manufacture
after thoroughly brushing the surface free
from mortar droppings, and other foreign
matter and also including preparing the
surface even and sand -papered smooth
Extra over above item for every subsequent
b 8700.00 coat of of wall painting with plastic emulsion / 33.39 Sq.mt.
Oil paint of approved brand.
Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty) or
equivalent & two coats of primer of approved
brand and manufacture on new wall surface
to give an even shade including thoroughly
brushing the surface free from mortar
dropping and other foreign matter and sand
papered smooth.
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and
jointing the pipes in c.m. 1:1 incl. all jointing
26 materials such as cement, sand, hemp,
bitumen as dire. testing the pipe line to a head
of 1.5 mt. and hydraulic test as dire incl.
watering trenches, spreading , and carting
away of surplus earth within 100 mt.lead as
dire. etc. comp.
a 120.00 23 cm dia. 344.64 Rmt
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work site,
unloading, lowering in trenches, laying and
jointing the pipes in c.m. 1:1 incl. all jointing
materials such as cement, sand, hemp,
bitumen as dire. testing the pipe line to a head
of 1.5 mt. and hydraulic test as dire incl.
watering trenches, spreading , and carting
away of surplus earth within 100 mt.lead as
dire. etc. comp.
b 25.00 15 cm dia. 288.23 Rmt
c 15.00 10 cm dia. 211.05 Rmt
Constructing brick masonry chamber for
under ground C.I. Inspection chamber and
bends with bricks having croshing strength
not less than 35 Kg. Cm2 in C.M. 1:5 C.I.
cover with frame (Lightduty) 455mm x
mm intenal dimensions total weight of cover
with frame to be not less than 38 Kg. (Wt. of
27 14.00 cover 23Kg.) and Wt. of frame 15Kg.) 3863.85 No.
(R.C.C.top slab with 1:2:4 mix (1-cement:2-
coarse sand:4-graded stone aggregate 20mm
size) foundation concrete 1:5:10 inside plaster
15 mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on
walls and bed concrete etc. complete.(i)
Inside dimensions 455 mm x 610 mm and up
Constructing Manhole with R.C.C. top slab in
1:2:4mix (1-cement: 2-coarse sand:4-graded
stone aggregate 20 mm nominal size)
foundation concrete 1:3:6 mix (1-cement:3-
coarse sand:6-Brick bats 40+50mm size)
inside plastering 15mm thick with Cement
Mortar 1:5 (1-Cement:5-coarse sand) finished
with a floating coat of neat cement and
making channels in cement concrete 1:2:4
mix (1-Cement:2 -Coarse sand:4-stone
28 a 4.00 aggregate 20 mm nominal size) finished 19139.10 No.
smooth complete including curing and festing
(i) Inside size 900mm x 1200mm and up to
1.5M. deep including C.I. cover with frame
size 560 mm diameter total weight of cover
and frame to be not less than 128kgs. (Wt. of
cover 64Kg. and Wt. of frame 64Kg.) (A) With
230 mm thick walls of brick masonry using
brick having crushing strength not less than
35Kg./Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2)B type depth up
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal
basin of 340x280x470 mm sizes respectively
with standard flush pipe, Waster Pipe, Waste
Coupling, PVc Connection and G.I clamps
complete, including painting of fittings and
brackets, cutting and making good the walls
and floors wherever required : Cera Model
No. S4020103 or Equivalent
Providing and Fixing of C.P. Brass BIB Cock
of 15 mm Dia of Jaquar make florentine
b 50.00 series model no. 5047n or equivalent make 1564.17 No.
with all necessary fittings. as approved by
Engineer - in - charge.,
Providing and fixing brass screw down Angle
stop tap.(A) 15mm dia. Of Jaquar make
c 50.00 florentine series modelno. 5053n or 1160.57 No.
equivalent make with all necessary fittings.
as approved by Engineer - in - charge.,
Providing and fixing C.P. brass shower rose
d 6.00 with 15mm or 20mm inlet Shower Arm.(A) 279.37 No.
100mm dia. Each
Provding and Fixing of autoclosing pressmatic
pillar cock / bib cock with all necessary fittings
of Polished Bright Chrome Finish of Jaquar
e 12.00 make model no. 031L65 or equivalent make 3280.52 No.
as approved by Engineer in Charge. Rate
including of cost of labour, material etc. in
complete manner.
Providing and Fixing of C.P. Brass Two Way
Bib Cock of 15 mm Dia of Jaquar make
f 22.00 model no. 041kn or equivalent make 1411.58 No.
approved make with all necessary fittings. as
approved by Engineer - in - charge.,
Providing and Fixing of C.P. Brass urinal
Valve Auto Closing System With Full Built in
Control Cock & Wall Flange of 15 mm Dia of
g 5.00 Jaquar make model no. 077 or equivalent 2568.08 No.
make approved make with all necessary
fittings. as approved by Engineer - in -
Provdg. & laying S.W. Gully trap with C.I.
garting brick masonry chamber & water tight
30 12.00 C.I. cover with frame of 300 mm x 300 mm 1234.57 No.
size ( inside) with standard weight. sqare
mouth trap size 150 x100 mm P trap
Providing erecting and fixing double coated
31 2000.00 ISI water tank of required capacity each with 3.91 Litre
all necessary fittings and connection etc.
complete on terrace
Extra rate over item of excavation of earth for
excavation of asphalt pavement/RCC of
thickness up to 0.20 meter including
32 20.00 demolishing the asphalt carpet, metal, soiling 71.43 Sq.M.
/ cutting Reinforcement etc.comp. with
stacking the material as directed.-up to
meter thickness
Providing and fixing PVC SWR Nahni trap IS
14735 for drain - 100 mm diameter with jali of
33 42.00 the following nominal diameter of self 565.43 No.
cleansing design with C.I scread down or
hinged grating including the cost of cutting
and making good the walls.
Provdg. And fixing Concealed / Open to wall,
ceiling & floor in true line and level UPVC pipe
Schedule- 40 of make as approved by engg.
incharge. pipe shall be fix on wall with the
34a help of clamp at every twi meter center to
center of shall be concealed as directed in
cluding neccesarry fitting etc. in cluding
testing of pipe and jointd and fixing the same
with adhesive solvent , including cost of all
materials of following nominal bore
iii 30.00 32 mm 117.97 Rmt
Providing and fixing concealed center point to
wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF)
34b seal for potable water of following dia.
nominal bore tube fittings and clamps
including making good the wall, ceiling and
floor etc. complete
iii 35.00 25 mm 247.25 Rmt
Provdg. And fixing to wall ,ceiling and floor
10.00 kg. F/Sq.Cm2 working pressure
35 polythelene pipes of the following outside
diameter, low, density, complete with special
flange compression type fittings, wall clips etc.
making good wall ceiling and floor.
b 70.00 (A) 75mm dia 274.68 Rmt
Providing and fixing water closet squatting
36 9.00 Pan ( Indian type W.C. Pan) size 580mm 1351.49 No.
(A)VitreousChina. (I)Long pattern = White
colour with Trap and Pair of Foot Rest
Providing and fixing white vitreous china
extended wall mounting water closet of Cera
Make S1043101 Carat Model Or Equivalent
Model With EWC Soft Close Seat Cover,
Chair Bracket, nuts, bolts and gasket etc
Providing and Fixing of C.P. Brass Flush
Cock of 25 mm Dia of Jaquar make model
no. 081 or equivalent and Outer Body of
b 29.00 Jaquar make model no. 5083KPM or 2732.58 No.
equivalent approved make with all necessary
fittings. as approved by Engineer - in -
Providing and fixing Health Faucet of Jaquar
c 20.00 make model no. 573 oe equivalent make as 1543.36 No.
approved by engg. In charge with flexible tube
upto 1 metre long etc. complete.
Providing and fixing 24"x18"x8" Carysil
Elegance or Equivalent Make of Single Bowl
38a 4.00 Sink S.S. Matt Finish With Waste Coupling, 7960.49 No.
Waste Pipe,etc. cutting and making good the
walls wherever required.
Providing and fixing Under counter Wash
basine including 15 mm C.P. Brass Pillar tap,
32 mm C.P. Brass Waste of Standard make,
b 4.00 Cutting & Making good the wall / granite 6641.14 No.
Wherever Required in White Color : Model
S2030101 of Cera Clair Series or Equivalent
make Wash basine of size : 520x450 mm
Providing and fixing Wall Hung wash basin
Including 32 mm C.P. brass waste of standard
c 16.00 pattern, cutting and making good the walls / 3825.20 No.
granite wherever require:In White Color : Cera
Cadal Or Equivalent Make Wash basin of size
Provdg. & fixing 600mm x 450 mm Bevelled
edge mirror of superior glass mounted of .6
39a 16.00 mm th. A.C. sheet or plywood sheet and fixed 825.48 No.
to wooden pluge with C.P. brass screws and
Providing and fixing mirror of superior glass
(of approved quality) and of required shape
and size with plastic moulded frame of
approved make and shade with 6 mm thick
hard board backing : Rectangular shape
Provdg. & fixing C.P..Brass towal rail
complete with C.P. brass brackets fixed to
wooden plugs with C.P. Brass screws.(600
mmx 20 mm size)
Providing and fixing ball valve (brass) of
41 approved quality, High or low pressure, with
plastic floats complete :
ii 1.00 20 mm dia 1099.94 No.
iii 25.00 25 mm dia 1552.93 No.
iv 12.00 40 mm dia 3312.60 No.
42a Providing and fixing Full Way valve (HEX)
with wheel of approved quality :
i 2.00 15 mm Full Way valve (HEX) 1461.17 No.
ii 2.00 20 mm Full Way valve (HEX) 1924.61 No.
iii 8.00 25 mm Full Way valve (HEX) 2535.55 No.
iv 1.00 32 mm Full Way valve (HEX) 3377.64 No.
v 8.00 40 mm Full Way valve (HEX) 4661.10 No.
vi 3.00 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass Pillar Cock
of 15 mm Dia of approved make with all
necessary fittings. as approved by Engineer -
b 4.00 Providing fixing of SS grab bar with all 1937.24 No.
hardwares for Physically Handicap toilet.
Providing and laying integral cement based
water proofing treatment including preparation
44a 690.00 of surface as required for treatment of roofs, 1150.48 Sq.M.
balconies, terraces etc consisting of following
(a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with
water proofing compound conforming to IS.
2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls
upto 300 mm height including cleaning the
surface before treatment.
(b) Laying brick bats with mortar using broken
bricks/brick bats 25 mm to 115 mm size with
50% of cement mortar 1:5 (1 cement :
coarse sand) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineer-in-charge over 20 mm
thick layer of cement mortar of mix 1:5 (1
cement :5 coarse sand ) admixed with water
proofing compound conforming to IS :
and approved by Engineer-in-charge to
required slope and treating similarly the
adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a
second coat of cement slurry using 2.75 kg/
sqm of cement admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge.
(d) Finishing the surface with 20 mm thick
jointless cement mortar of mix 1:4 (1 cement
:4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and
approved by Engineerin- charge
(e) The whole terrace so finished shall be
flooded with water for a minimum period of
two weeks for curing and for final test.“All
above operations to be done in order and as
directed and specified by the Engineer-in-
Charge :and shall be guaranteed for minimum
period of 10 years after handing over the
completed building by the main contractor to
be finished as directed. Stamp paper
guarantee 10 years to be furnished before
receiving any payment from the client.
With average thickness of 120 mm and
minimum thickness at khurra as 65 mm.
Providing and laying broken chine mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out upto
surface using white cement including
rounding off junctions and extending them
upto 15 cm along the wall,clearing with water
and oxalic acid etc. as directed.
Providing and applying fibre reinforced
elastomeric liquid water proofing membrane
with resilient acrylic polymers having Sun
Reflectivity Index (SRI) of 105 on top of
concrete roof in three coats @10.76 litre/
sqm. One coat of self-priming of elastomeric
c 360.00 waterproofing liquid (dilution with water in the 562.40 Sq. M.
ratio of 3:1) and two coats of undiluted
elastomeric waterproofing liquid (dry film
thickness of complete application/system not
less than 500 microns). The operation shall
be carried out after scrapping and properly
cleaning the surface to remove loose particles
with wire brushes, complete in all respect as
per the direction of Engineer-in-Charge.
Filling in Sunken Portion with good Quality
Aerated light weight concrete block having
crushing strength not less than 35 kg/sqcm
and where directed by the Architect /
Engineer-in-charge, in sunk in layer. including
watering, ramming where it is required etc.
complete, as directed by the Architect /
Engineer-in-charge .
Providing and laying cement concrete flooring
( I.P.S.) 1:2:4 (1-cement : 2-coarse sand : 4-
45 200.00 graded stone aggregate 20mm nominal size) 348.08 Sq.M.
laid in one layer and finished with a floating
coat of neat cement. (B) 50mm thick.
Providing and fixing M.S. grills/ Gate of
required pattern to wooden/ Granite frames of
windows etc. with M.S. flats at required
46a 5500.00 spacings and frame alround, square or round 100.17 Kg.
bars with round headed bolts and nuts or by
screws all complete as per the structural
designs and directions of Engineer in charge
Providing & Fixing Structural steel work (
Confirming to IS 4923-1997) riveted, bolted or
welded in builtup for all type sections, in
framed work, including cutting, hoisting, fixing
in position and applying a priming coat of
approved steel primer all complete as per the
structural designs and directions of Engineer
Applying priming coat over new steel and
other metel surface after and including
preparing the surface by throughly cleaning,
c 700.00 oil, grease, dirt and other foreign matter and 34.34 Sqmt
scoured with brushes fine steel wood,
scrapers and sand paper with ready mixed
priming paint brushing red lead.
Painting two coats (excluding priming coat) on
new steel and other metal surface with
d 700.00 enamel paint, brushing, interior to give an 86.94 Sqmt
even shade including cleaning the surface an
even shade including cleaning the surface of
all dirt, dust and other foreign matter.
Providing & Fixing 1 mm Thick S.S.-304
Grade 90 mm High S.S. Railing having Hand
Rail Member of 50 mm Dia., 3 No. of
Horizontal Pipe of 16 mm Dia. & Baluster
Suppprt of 40 mm Dia. At Every Third Step as
per Detail Given. Rate Includes All Work
Complete as per Description & as per
Direction of Engg. in Charge.
Providing and fixing in position collapsible
steel shutters with vertical channels 20x10x2
mm braced with flat iron diagonals 20x5 mm
47a 72.00 size with top & bottom rails of T-iron 40x40x6 5391.23 Sq. M.
mm with 38 mm dia. Steel pulleys complete
with bolts , nuts , locking arrangement
stoppers , handles including applying a
priming coat of red lead paint.
Providing corrugated 0.80 mm (22 gauge)
thick G.I. sheets roofing fixed with galvanized
b 5.00 iron ‘J’ or ‘L’ hook bolts, and nuts 8 mm. dia 719.93 Sq.M.
with bitumen and G.I. limpet washers filled
with white lead complete excluding the cost of
purlines, rafters and trusses.
Providing valleys 900 mm. overall in plain
c 3.00 mm. thick G.I. sheet Class – 3 fixed with ‘J’ or 1042.78 Sq.mt.
‘L’ hook bolts and nuts galvanized from ‘J’ or
‘L’ hook bolts and bitumen washers complete.
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their entire
length and jointed together at the ends by end
48a 18.00 locks mounted on specially designed pipe 3468.72 Sq.M.
shaft with bracket plates, guide channels and
arragements for inside and outside locking
with push-pull operation including the cost of
hood cover and spring etc. complete.(A)
Shutters having width below 3.5 M.
Providing and fixing 27mm domal Series -
mm Th. Alluminium Section Three track
49a 280.00 Sliding window With Metalic Powder Coating 6373.85 Sq. M.
and 4 MM Clear Glaas(Non Tuffen) Include
All Accessaries and Fixture etc. complete as
per the direction of Engineer-in-charge.
Providing and fixing 27mm domal Series -
mm Th. Alluminium Section Two track Sliding
b 14.00 window With Metalic Powder Coating and 4 4999.10 Sq. M.
MM Clear Glaas(Non Tuffen) Include All
Accessaries and Fixture etc. complete as per
the direction of Engineer-in-charge.
ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door work
(Single Shutter OR Double Shutter with fix
glass) made from Jindal or equivalent make
Powder Coated (50 micron pure polyester
coating ) ,aluminium section frame built up
standard tubular and other section of
approved make confirming to IS 733 and IS
1285 , member size with shutters of horizontal
member , vertical member Confirming to
IS733 and IS 1285 fixed with rawl plug abd
screws or fixing clips or with expansion hold
fasteners including necessary filling up of
gaps at junctions at top bottom and sides with
c 11.00 required PVC/ Neoprene felt, 8/12 mm 5401.70 Sq. M.
toughened glass of approved make etc.
Aluminum sections shall be smooth, rust free,
straight.mitred and jointed mechanically
wherever required including Door Hardware
such as cleat angles aluminum snap beading
for glazing /paneling, CP Brass/ Stainless
steel screws, Stoppers, heavy duty floor hing,
S.S. Hinges, aldrop , Locking system, heavy
duty Floor Springs, Pivot and fixtures and
transparent silicon sealant glass fixing to
frame as per details all complete as per
architectural drawings and the direction of
Engineer in Charge. rate incl. all type of
alumnium sections for doors as per the detail
Architectural dwg.
Providing and fixing standared extruded of
alluminium section of size 63 mm x 38.10 mm
50 a 15.00 x 1.2mm (Section:2434, @ Wt.0.643Kg/mt ) 1163.92 Sq. M.
with colour anodized alluminium frame for
ventilation with 5 mm thick frosted glass as
details etc complete for Ventilation
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
1.95 mm ( Section no: 4605, @Wt 1.094 Kg /
50 b 20.00 Rmt with colour anodized alluminium frame 1509.90 Sq. M.
with 5 mm thick transparent bronze colour
tinted float glass as details etc complete for
Providing Fixing 1.2 mm thick Alluminium
Section Partition -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
Having Size of Section of 2.1/2 x 1.1/2 with
mm Compact Sheet / 5 mm thick Glass Fixing
with 4 mm thick EPDM Rubber etc. Complete
as per Direction of Consultant /
Providing Fixing 1.2 mm thick Alluminium
Section Partition Door -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
frame Having Size of Section of 2 .1/2 x
.1/2 and Door Section Having Size of Tips
50d 13.00 Vertical 1 .3/4 x 1 .3/4, Top Rail 4 x 1 .3/4, 4061.77 Sq.mtr.
Middle Rail 1 .3/4 x 1 .3/4, Bottom rail 4 x
.3/4 with 4 mm Compact Sheet / 5 mm thick
Glass Fixing with 4 mm thick EPDM Rubber
Including Lock, Handle, Door Closer, Door
Stoper, Stopper etc Complete as per Direction
of Consultant / Engg.incharge.
Providing and fixing Structural Glazing with
using the 17 Micron anodised of approved
colour alluminium section as transium,
mullium of size 63mm x 38mm x 2 mm with
using 6 mm thick reflective structural glass of
approved make, colour / Tinted, toughned and
shade and fixed with silicone sealant and
spacer tap and at corner sealed neoprene
foam dust and Air sealed gasket mirred
including scaffolding, cleaning of glass
etc.complete at all heights anf lifts with all
necessary fitting and fixtures, anchore
51a 230.00 fasteners, necessary M.S. or Aluminium 3953.75 Sq.mt.
brackets, suitable design for openable or
sliding window as per Architectural drawing
and as directed by Engineer-in-charge.
Grooves between the glasses to be filled with
sealant of Dow corning - structural sealant
995, weather sealant 789. The entire facade
should be water proof. The mullions are to be
connected to bracket by SS-304 nut bolts.
Measurement shall be given as per actual
execution of the work. (Rate are included
providing & fixing of MS structure steel work
wherever Required)
Design supply & installation of suspended
Spider Glazing system designed to withstand
the wind pressure as per IS 875 (Part-III). The
Suspended System held with Spider Fittings
of SS-316 Grade Steel of approved
manufacturer with glass panel having 12 mm
thick clear toughened glass held together with
SS- 316 Grade Stainless steel Spider & bolt
assembly with laminated glass fins 21 mm
thick. The Glass fins and glass panel
assembly shall be connected to Slab/ beams
by means of SS- 316 Grade stainless steel
brackets & Anchor bolts and at the bottom
using SS channel of 50x25x2mm using
fastener & anchor bolts, non staining weather
sealants of approved make, Teflon/ nylon
bushes and separators to prevent bi-metallic
contacts, all complete to perform as per
specification and approved drawings. The
complete system to be designed to
accommodate thermal expansion & seismic
movements etc. The joints between glass
panels (6 to 8 mm) and gaps at the perimeter
& in U channel of the assembly to be filled
with non staining weather sealant, so as to
make the entire system fully water proof &
The rate shall include all design, Engineering
and shop drawing including approval from
structural designer, labour, T&P, scaffolding,
other incidental charges including wastage,
enabling temporary services all fitting fixers
nut bolts, washer, Buffer plates, fastener,
anchors, SS channel laminated glass etc. all
complete. For the purpose of payment, actual
elevation area of Glazing including thickness
of joints and the portion of Glass panel inside
the SS channel shall be measured.
Providing and fixing 12 mm thick Toughened
Glass Door with / Without Fix Portion
Including Floor Spring , Lock, 300 mm Long
Door Handle, Nut Bolt, Clamp, Connector and
All accessaries as approved by Engg.
Providing and fixing ISI marked 35 mm thick
flush door shutters conforming to IS :
(Part I) decorative type, core of block board
construction with frame of 1st class hard
wood and well matched teak 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters with
52a 101.00 mm thick Decorative Laminated Sheet on 4332.15 Sq.mt.
both faces of shutters including ISI marked
Stainless Steel butt hinges, bright /matt
finished 125 mm Stainless Steel handles of
approved quality & make, ISI marked
oxidised M.S. door latches / Aldrop
Conforming to IS:5930 with necessary screws
etc. complete as per direction of Engg.
Providing wood work in frames of Doors,
windows cleare story windows and
othersimilar works wrought, framede and fixed Cu.Decim
in position. (A) Indian Teak Wood
Providing and fixing 35 mm th. Shutters for
doors windows & clearstory windows incl.
wood frames as specified 12 cm. x 7cm. size
53 incl. anodised alluminium fixtures and
fastenings including primer coat of approved
quality and two coats of oil paint etc.
a 3.00 Fully glazed 4788.50 Sq. M.
b 3.00 Fully panelled 5478.89 Sq. M.
c 3.00 Partly panelled and partly glazed 5133.69 Sq. M.
Providing and fixing FRP frame size 100x50
mm and 28mm thick FRP depress panel
shutter having extra reinforcement on sides &
edges in Gel coat finish. The core of the
shutter & frame is to be filed up with injected
fire retardant grade polyurethene foam done
54 32.00 in situ alongwith embedded wooden pieces 2354.22 Sq.M.
for stiffening & also taking hinges & fintures.
The whole FRP frame & shutter is to be water
proof weather proof, termite proof &
resistance to mild acid/alkali. Rates are to be
inclusive of S.S hinges with necessary screws
& alluminium fixtures & fastenings & fastener
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be
well repaired as per instructions.
a 1.00 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1.00 For Pipe 400 mm to 600 mm diameter 2232.14 No.
Making connection of galvanised Mild steel
distribution branch with galvanised mild steel
56 1.00 main 50mm to 80mm nominal bore by 600.08 No.
providing and fixing tee including cutting and
threading the pipes complete
57a 1500.00 Providing throating or plaster drip, grooves 41.25 Rmt
and moulding to Wall , R.C.C. chajja and slab.
Providing & Laying cement vatta 10 cm x
cm in size quarter round in c.m. 1:1 (
57b 200.00 cement, 1 coarse sand) laid in one layers 23.45 Rmt
finishing with a floating of neat cement
watering etc complete as dire.
Carring out plinth treat ment to post
construction/ existing structure by spraying
chemical solution for termite control treatment
including labour and material consist ment
withI.S.I specification. Using Chlordene and
58 1100.00 Chiorpur files 20EC. As Per 6131_ paret- II 104.90 Sq.mt
Consentration Weight one percent is
recommended i.e one litre 20EC chemical
emulsion with19 liter give1% concrentration
inclusive of one litre chemical emulsion
appication at the rate of 5 Litre chemical/ Sqm
of surface is recommended as per I.S
Carring out timber treatment to all wood work
including drilling holes and spraying oil based
chemical solution on surface of timber work
for termite control including labour and
material etc. complete. Using Chlordene
20EC. As Per 6113_part III Consentration
59 10.00 Weight 1.00 percent is recommended one litre 54.98 Smt
chemical emulsion dillute with 9 liter of
kerosene precent concentration. Total dillute
concrentration will be10litre inclusive of the
litre chemical emulsion application 0.75/Litre
chemical per one Sqmt printed two coat wood
Paver Block Providing and laying shot blasted
Non - interlocking, Paver blocks of specified
thickness, size, grade of concrete and colour
machine made and blasting by automatic shot
blasting machine and high density of as per
approved sample of approved make for
footpath, parking areas, service lanes,cross
over and other areas as mentioned in the
drawing. Including providing and laying
mm thick averave bedding layer of coarse
sand below paver block as per required
grading and specification. Laid paver block
shall be mechanically compacted. The work of
the paving blocks shall be executed in line
and level by skilled mason of flooring work
only. Small size of paver block with same
specification shall be used at residue or at
end. It should be laid in such a way that the
no cutting of the paver block to be necessary.
If cutting of paver block shall be required
than cut by machine only and laying to be
done by skilled flooring mason. The finished
surface of the paver block shall have coarse
sand Texture Finish. Pave blocks shall be
compacted and shall be re-laid if necessary.
Actual laid area shall be measured and paid
without any wastage. (A) 80 mm thick M-35
grade Grey Paver block of size 200mm x
200mm. As per approved rate
Providing and fixing pre-cast concrete kerb
stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of
61 350.00 M250 grade concret as per approved design 358.06 R.mt.
and including excavation for fixing in proper
line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
Providing and fixing double action hydraulic
floor spring of approved brand and
manufacture conforming to IS : 6315, having
brand logo embossed on the body / plate with
double spring mechanism and door weight
62a 16.00 upto 125 kg, for doors, including cost of 4558.89 No.
cutting floors, embedding in floors as required
and making good the same matching to the
existing floor finishing and cover plates with
brass pivot and single piece M.S. sheet outer
box with slide plate etc. complete as per the
direction of Engineer-in-charge. With stainless
steel cover plate minimum 1.25 mm thickness
Providing and fixing aluminium extruded
section body tubular type universal hydraulic
door closer (having brand logo with ISi, IS :
3564, embossed on the body, door weight
upto 36 kg to 80 kg and door width from
mm to 1200 mm), with double speed
adjustment with necessary accessories and
screws etc. complete.
Designing, fabricating, testing, installing and
fixing in position Curtain Wall with Aluminium
63 125.00 Composite Panel Cladding, with open 3061.95 Sq.mt.
grooves for linear as well as curvilinear
portions of the building , for all heights and all
levels etc. including:
(a) Structural analysis & design and
preparation of shop drawings for pressure
equalisation or rain screen principle as
required, proper drainage of water to make it
watertight including checking of all the
structural and functional design.
(b) Providing, fabricating and supplying and
fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of
approved shades made out of 4mm thick
aluminium composite panel material
consisting of 3mm thick FR grade mineral
core sandwiched between two Aluminium
sheets (each 0.5mm thick). The aluminium
composite panel cladding sheet shall be coil
coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating of
approved colour andshade on face # 1 and
polymer (Service) coating on face # 2 as
specified using stainless steel screws, nuts,
bolts, washers, cleats, weather silicone
sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy
6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the
wind load movement, fasteners, SS 316 Pins
and anchor bolts of approved make in SS
316, Nylon separators to prevent bi-metallic
contacts all complete required to perform as
per specification and drawing The item
includes cost of all material & labour
component, the cost of all mock ups at site,
cost of all samples of the individual
components for testing in an approved
laboratory, field tests on the assembled
working curtain wall with aluminium composite
panel cladding, cleaning and protection of the
curtain wall with aluminium composite panel
cladding till the handing over of the building
for occupation. Base frame work cost for ACP
cladding is included in this item rate. The
Contractor shall provide curtain wall with
aluminium composite panel cladding, having
all the performance characteristics all
complete , as per the Architectural drawings,
as per item description, as specified, as per
the approved shop drawings and as directed
by the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on
the external face of the curtain wall with
Aluminum Composite Panel Cladding
(including width of groove) shall be measured
in sqm. up to two decimal places.
Providing and Fixing Box type metal letters
forming composite box made from 1mm thick
stainless steel plate of grade 304 having
64 brush finish of following font size to be fixed at
Main Gate in english and or Gujrati and
including fixing charges. etc. complete as per
direction of Engg. incharge. for Payment
Purpose Height of Letter will be measured.
a 960.00 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made out of
2mm thick s.s. plate grade 304, including
making necessary design as per Architect
dwg. Through laser cutting including
connection to the R.C.C./Masonary with
necessary frame,anchor fastnuts,M.S.Plate
etc. complete as per direction of Engg.
Providing and Fixing Sinage - internal and
65b 7000.00 external signage boards with Vinyle Text on 9.38 Sq.Inch
ACP sheet / 2 mm th. S.S. Plate etc. complete
as per direction of Engg. incharge.
Providing and fixing retro Reflective Hi
Intensity Micro Prismatic Grade Board using
2mm Aluminum / 4mm ACP, angle iron 75 x
75 x 6mm. Descaling and degreasing the
board as per requirement using epoxy
reflactive process by screen painting as
directed etc. complete including transporting
65c 8.00 and fixing in C.C. 1:2:4 with necessary 7535.31 Sq.mtr.
excavation curing etc. complete as per I.R.C.
67-2012 design. A warranty for 7 years for the
Retro reflective sheeting from original
manufacturer & a certified copy of 3 year
outdoor exposure test report from third party
test lab for the product offered shall be
submitted by contractor. (B)Class B Type-
4(MDR/ODR) retro reflective sheeting
Road marking with hot applied thermoplastic
paints with reflectorising glass beads on
bitumin surface providing and laying a hot
applied thermoplastic compound 2.5 mm thick
including reflectorising glass beads @
250gms per sqm area, thickness of 2.5mm is
excluding of surface applied glass beds as
per IRC:35-2015. The finished surface to be
level, uniform and free from streaks and
holes. zebra patta /bump patta lane/center
65d 100.00 line/ edge line/cut patta. The white color 364.08 Sqmt
marking should provide liminance coefficinet
on cemend road shalll be min 130 mcd/m2/lux
and Asphalt road shall be min
mcd/m2/lux during the service life during the
day time. The marking should meet the
performance criteria for night time reflectivity,
wet reflectivity and skid resistance as
mentioned in the section-15 of IRC
Warranty for the Retro reflectivity should be
CAT EYE/Pavement Marker(MNC two nail)
made out of acrylic StreneAcrylonitrile or hi-
impact poly Steren fitted with moulded of
metheacrylate(MNC)reflector cube corner
reflector design,filled with tightly adhering
65e 10.00 pooting compound as per ASTMD-788 size 160.71 Nos.
11.5x7x1.60 cms or 10x10x1.75 cms provided
with bituminous adhesive in sufficient quantity
with each unit fixing with two shrank .Reflector
on both side.Co efficient of lumination as per
specification and compressive strenth
tones at 23 degree centigrade etc.B) Double
Providing and fixing eco-friendly light weight
calcium silicate false ceiling tiles having T
egular edge & 15mm Thick Densified edges
on the Tile Periphery for Extra Strength The
Light weight calcium silicate ceiling tiles shall
have, light reflection 85% non-combustible as
per B.S.476 part IV, 100% humidity resistance
and also having thermal conductivity 0.043°
w/m KC. for the best thermal Insulation.
The Light weight calcium Silicate tile shall be
of approved texture Fine fissured/ Spintone/
Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent
of size 595X595 mm to be laid on true
horizontal level suspended inter locking metal
grid of hot dipped galvanized steel sections
(galvanizing @ 120 grams per sqm including
bothside) consisting of main ‘T’ runner
suitably spaced at joints to get required length
and size of 24X38 mm made from 0.30 mm
thick (minimum) sheet, 1200 mm centre to
centre, and cross ‘T’ of size 24X28 mm made
out of 0.33 mm (Minimum) sheet spaced
mm along spaced between main ‘T’ at
mm centre to centre to form a grid of
1200X600mm and secondary cross ’T’ of
length 600mm and size 24x28mm made of
0.30 mm thick (Minimum) sheet to be
interlocked at middle of the 1200X600mm
panel to form grid of size 600X600mm resting
on periphery walls / partitions on a perimeter
wall angle pre-coated steel of size
(24X24X3000mm made of 0.40mm thick
sheet with the help of rawl plugs at 450mm
centre to centre with 25mm long dry wall
screws @ 230mm interval and laying 15mm
thick Densified edges light weight calcium
silicate ceiling tiles of approved texture (Fine
Fissured/ Cosmos/Spintone) in the grid
including, cutting /making opening for services
like diffusers, grills, light fittings, fixtures,
smoke detectors etc., wherever required,
Main ‘T’ runners to be suspended from ceiling
using G.I. slotted cleats of size 25X35X1.6mm
fixed to ceiling with 12.5mm dia and 50mm
long dash fasteners, 4mm G.I. adjustable rods
with galvanized steel level clips of size
85X30X0.8mm, spaced at 1200mm centre to
centre long main ‘T’ bottom exposed with
24mm of all T-sections shall be pre-painted
with polyester baked paint, for all heights,
, as per specifications, drawings and as
directed by engineer-incharge.Note:- Only
calcium silicate false ceiling area will be
measured from wall to wall. No deduction
shall be made for exposed frames/ opening
(cut outs) having area less than 0.30 sqm.
The calcium silicate ceiling tiles shall have
NRC. Value of 0.50 (Minimum) for Fine
fissured/ Spintone/ Cosmos and 0.75 NRC for
Globe, light reflection 85% noncombustible as
per B.S. 476 part IV, 100% humidity
resistance and also having thermal
conductivity. 0.043° w/m KC.for the best
thermal Insulation
Providing and fixing single layer water proof
gypusm board 12.5 mm thick of the make
New good Group Co.Ltd. or equivalent & New
good Group Co.Ltd. company sections using
water proof board of size 1220 mm x
mm x 8.0 mm suspended by G.I suspender of
size 25 mm x 3 mm with intermediate channel
66b 805.00 of size 18mm x40mm x0.80mm at 1220 mm 600.94 Sq.mt.
center to center ceiling section of size 40mmx
35mmx 0.55mm at 457 mm center to center
and perimetre chanel A of size 20mm x 27mm
x 30mm x 0.50mm at edges & drops including
paper taps and sofit cleat, anchor fastener,
scoch bolt connecting cleat joining compound
top coat on ceiling including making
necessary opening for light fitting, diffuser etc.
complete as per detail drawing as directed.
Providing and Fixing 6 mm thick Lexan
Polycarbonate multi wall roofing sheet fixed
67 10.00 with hilti screw and rubber silicon sealer and 1427.62 sq.mt.
alluminium strip of size 50 x 3 mm etc
complete as directed by Engineer in charge
Manufacturing,testing ,supplying
loading,,transporting to work site,loading
unloading lowering in trenches,laying and
68 jointing RCC NP3 class pipes in C:M 1:1
including all jointing materials such as
cement,sand,hemp bitumen as directed
testing the pipe line to a head of 1.5 mt and
hydraulic test as directed etc comp.
a 50.00 300 mm Diameter 616.07 Rmt
b 190.00 450 mm Diameter 806.25 Rmt
Constructing Bombay Pattern Type Catch Pit
x 0.60 depth up to 1 mt including excavation,
(1:5:10), 23 cms thick brick maso. wall in the
69 25.00 prop. of CM 3125.00 No
(1:6) with 40 mm thick IPS flooring in the prop
bottom and 15 mm thick cement plaster inside
the catch pit in the proportion of CM (1:3) with
out jali etc. comp. as
CatchPit Jali Fixing P/F FRC catch pit jali with
70 25.00 frame 600mm x 600mm clear opening etc. 1383.93 No
comp.. As directed by engineer in charge.
PERCOLATION WELL
71 120.00 Drilling of pilot bore hole in Alluvial Strata by 694.64 Rmt
direct Rotary Rig of 250 mm.
72 120.00 Reaming 400 mm 212.50 Rmt
73 1.00 Electro Logging charges with carting 16071.43 Job
74 60.00 Providing and Installing 200 mm dia IS:12818 1193.75 Rmt
upvc Casing Pipe "CM" class plain Pipe
75 1.00 Providing and Installing 200 mm dia IS:12818 669.64 Set
upvc End Cap, with Air Vent cowl
200 mm dia Regular with 1.5 mm sloted size
cage type trapezoidal shape wire wound little
carbon galvanized screen confirming to
77 10.00 Supply of Pea sized Gravel 2029.46 Cmt
78 1.00 Air Vent of 50 mm Bend 401.79 Unit
79 120.00 Lowering and Removing of Dropline up to 147.32 Rmt
80 1.00 Air Compressor 60 CFM/150 PSI 22205.36 Ls
Estimate For Civil Work With Percolation Total Rs.
I. No. Qty Items Unit Rate Per Amount
Electrical Work Estimate
1 INTERNAL WIRING
Point wiring for Light / Bell with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to
mtr length , in below type of pipe erected with
6A Modular type switch / bell push &
1.1 accessories and earth continuity of following
type, erected on PVC / Metallic/Wooden box,
single mounting base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
330.00 accessories erected concealed in wall/ceiling 505.05 Pt
Point wiring for FAN with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of
.ISI marked 1.1 KV Grade ZHFR/HRFR PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected with
6A Modular type switch and hum free EME
four or more step type electronic fan regulator
1.2 with separately mounted and accessories
with earth continuity of following type erected
on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose /
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
245.00 accessories erected concealed in wall/ceiling 701.40 Pt
Point wiring for secondary light point with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm (green)
both are of ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand
copper wires, in below type of pipe to be
erected complete with earth continuity and
1.3 necessary connection with primary light with
accessories erected on Metal / PVC /
wooden box covered covered with appropriate
front plate modules erected on / in wall /
ceiling for open / concealed wiring. with
necessary Lamp holder / ceiling rose /
H.D.Connector as directed.as per pipe
erected with following type of accessories.
Note:- Maximum up to 6 mtrs length, excess
will be considered as Mains for Secondary
(f) with medium class Rigid PVC pipe and
305.00 accessories erected concealed in wall/ceiling 174.30 Pt
Point wiring for Individual Plug with & earth
wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to
1.4 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe
erected with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5
1.4.1 120.00 sq.mm Cu. Wire from nearby 530.25 Pt
switchboard/mcb db board
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
1.4.2 50.00 [II] For 16A Plug and 16 amp switch with 2- 774.90 Pt
2.5 sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
[III] For 16A Plug and 16 amp switch with 2-4
1.4.3 20.00 sq.mm Cu. Wire with 2.5 sq.mm ( green) 906.15 Pt
earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in wall/ceiling
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on
PVC / Metallic/Wooden box, single mounting
1.5 150.00 base frame covered with textured / 255.00 Pt
metallic/white front plate modules erected on
/ in wall / ceiling with following type
Point wiring for Two Way Controlled Light
Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked 1.1 KV
grade ZHFR/HRFR PVC insulated multi
strand copper wires erected in below type of
pipe with 6A Modular type switches and
1.6 following type of accessories erected on PVC
/ Metallic/Wooden box, single mounting base
frame covered with textured / metallic/white
front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary
batten/angle holder or ceiling rose or
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
8.00 accessories erected concealed in wall/ceiling 627.90 Pt
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
1.7 frame covered with textured / metallic/white
front plate , modules erected with necessary
connections as per site situation directed by
Engineer In charge.
1.7.2 5.00 (2) One No 5 pin plug 150.00 E.a.
1.7.3 80.00 (7) Blank Plate Single 25.00 E.a.
1.7.4 1.00 (8) Computer RJ-45 socket 159.00 E.a.
1.7.5 50.00 (9) 16 Amp. SP one way switch 179.00 E.a.
1.7.6 50.00 (10) 6/16Amp. Universal socket 198.00 E.a.
Modular MCB Switch
Pole Modular MCB Switch
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected
1.8 with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as
Providing & erecting PVC Corrugated Flexible
1.9 Conduit with required nos. of coupling, PVC
bushes, Check-nuts etc. complete of following
providing and erecting Mains with ISI marked
electrolyte stranded copper conductor, Non
PVC Zero Halogen free fire retardant
insulated copper conductor, insulated wire
(HRFR) conforms to IS-694, erected in
existing pipe with 1.5sq. mm copper
conductor of same specifications for earth
continuity of following size.
In Existing medium class Rigid PVC pipe and
providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
1.11 type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for
earth continuity of following size
(A) with medium class Rigid PVC pipe and
(use earth wire of 4 sq.mm )
providing and erecting Mains with ISI marked,
1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC -
1.12 erected in existing pipe of following size
(Specifically for control panel, relays, power
switchgears, motor starters & control wiring)
with required size of copper lugs, nuts and
bolts if required.
1.12.1 10.00 (e) One wire 6.00 sq. mm 56.00 Mtr
1.12.2 10.00 (f) One wire 10.00 sq. mm 91.00 Mtr
1.12.3 15.00 (g) One wire 16.00 sq. mm 141.00 Mtr
1.12.4 10.00 (h) One wire 25.00 sq. mm 234.00 Mtr
1.12.5 20.00 (i) One wire 35.00 sq. mm 298.00 Mtr
1.12.6 40.00 (k) One wire 70.00 sq. mm 663.00 Mtr
Supplying and erecting Flexible PVC
1.13 insulated multi strand multi core 1.1 kv grade
ISI marked copper wires of following size to
be erected as directed.
1.13.1 140.00 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
1.13.2 80.00 h) 2.50 Sq.mm 3 core round PVC sheathed 77.00 Mtr
1.13.3 30.00 k) 4.00Sq.mm 4 core round PVC sheathed 175.00 Mtr
Supplying & erecting M.S. Box having
Gauge painted with red oxide or Heavy duty
1.14 PVC box erected flushed on wall or concealed
in wall with necessary plastering & finishing
as directed of following size.
Supplying and laying UPVC cable trunking
system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and
1.15 flame proof confirming BS with necessary end
caps Internal and external bend, flat bends,
coupler, tee etc..All necessary accessories
and measuring of following sizes
1.15.1 5.00 (2) 100 mm x 50 mm trunking 424.00 Mtr
1.15.2 5.00 (4)100 mm x 50 mm trunking with TWIN 1309.00 Mtr
compartment With clip in divider
Supply & installation of surface mounted U
PVC snap-on adaptable trunking raceways,
fabricated out of U-PVC to Off-White or
approved shade as per IS 733 of thickness
2.0mm for the base and sides with all
accessories like removable covers, joints
,height spacer,angles complete with
necessary bends, suitable sized junction
boxes and tees etc, Complete.
(a)Size: 50x80mm PVC Raceways for Power
5.00 & Data with 2 compartments above 1052.00 Mtr
specifications.
Supply & installation of modular type
accessories for U PVC snap-on adaptable
1.17 trunking/Pop up Box with required items
erected with necessary connection. As
desired by Engineer In charge
1.17.1 1.00 i) 6 A SP 1 Way Switch 204.00 No
1.17.2 1.00 ii) 16A SP 1 Way Switch 351.00 No
1.17.3 1.00 iv) 6A universal socket shuttered 347.00 No
1.17.4 1.00 iv) 6/16 A universal socket shuttered 458.00 No
1.17.5 1.00 vi) Cat-6 LAN Socket 561.00 No
SUB - TOTAL OF INTERNAL WIRING
2 Switchgears , Panels , MCBDBs & MCBs
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to
2.1 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all
internal connections, spreader tinned copper
& complete erected in existing 16 G.M.S.
6.00 ICS=100% of ICU only 6112.00 No
Providing and erecting Approved make Four
pole moulded case circuit breaker having
breaking capacity ICU of 50 K.A. and above
at 415 V having normal current rating up to
2.2 630A. with variable thermal & magnetic
release suitable to work on A.C.supply 50 c/s.
with all internal connections, spreader tinned
copper & complete erected in existing
1.00 ICS=100% of ICU only 27895.00 No
providing and erecting Approved make Earth
fault Relay suitable to mount with inter
connection suitable to following size of
2.3 moulded case circuit breaker having CT ratio
& MCCB rating as following along with shunt
trip 220V AC. with all internal connections &
complete erected in existing M.S.housing..
Fabricating the box type items made from
M.S. Sheet with A.I. supports, wings, doors,
handles other hardware materials as per
2.4 25.00 requirement design with finishing by three 179.00 Kg
tank powder coating processed inside and
outside painted, erected as directed including
minor civil work. to install above MCCB.
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type, wall / Floor mounted LT panel
suitable for 415 V 3 phase, 4 wire 50 Hz AC
supply system fabricated in compartmentised
design from CRCA sheet steel of 2 mm thick
for frame work ,Doors and partitions IP 42 and
covers,3 mm thick for gland plates i/c cleaning
and finishing complete 9 tank process in
house facility for powder coating in approved
shade, extendable type FP aluminium alloy
busbars of high condectivity, DMC/SMC
busbar supports, entire panel shall have a
common copper earthbar of size 25mm X
mm / 50 x 6 Al at the rear with 2 Nos. earth
studs, solid connection from main busbar to
switchgears with require size of aluminium
busbar & control wiring with 1.5 sqmm FRLS
insulated copper conductor cable, cable
alleys, cable gland plates i/c accessrories as
per specification and providing switchgears,
metering instruments etc. for following
panel.G.A.Drawing to be approved by EIC or
consultant. ( Outgoing connectors must be
nut-bolt type. Outgoing mains for 63Amp
MCBs must be of 4 x 16sqmm cu flexible
wires).Incomers Mains for MCBs shall be
always from the busbars.
( a ) Providing cable clamps / supports within
distribution boards cable alley.
( b ) All hinged door shall be earthed through
2.5 sq mm tinned b raided copper wire.
( c ) Pad locking of MCCB’s handles in “OFF”
( d ) All the C.T.s should be auto short link
( e ) All the MCCB's should be with rotary
( f ) All incoming and outgoing air circuit
breakers shall be placed on middle portion of
the vertical in single tier formation.
( g ) Any descripancy found in SLD & Boq , it
should be brought in the notice of the client /
consultant, and the decision will be taken final
by Client / consultant.
2.5.1 1.00 MAIN L.T.PANEL 461059.00 No
Main LT PANEL (As described above &
consisting of following items) AS PER SLD.
(i) 1 no of 500 Amp,50KA FP MCCB,50KA
With Adjustable μP Release for O/C,S/C,E/F
with 240V under voltage release, LED Type
Indicating Lamp (R-Y-B-ON-OFF)
(iii) Digital type 3 phase Multi function Meter
CL-1 with RS-485 PORT, CT 500/5A CL-0.5
,15VA, 2A SPMCB-7nos.,Neutral link.., CT for
APFC Relay in Y-Phase
600 Amps, 415 V, FP Aluminium Busbars
with Heat shrinkable color code insulation
sleeves.( 1 sqmm = 0.8Amp )
( a ) 1 no.250A FP,36 KA,415V FP MCCB
TM Based with O/L,S/C protection with MFM
having suitable rating of CTs, spreader
link,Rotary handle,Aux. contact,Shunt release
240V AC,2A SP MCB, Neutral link --R-Y-B
indicating lamps.
(b ) 1 no.200A FP,36 KA,415V FP MCCB TM
Based with O/L,S/C protection with KWH
Meter 200/5A CL-0.5, 15VA CTs, spreader
link,Rotary handle,Aux. contact,Shunt release
240V AC,2A SP MCB, Neutral link --R-Y-B
indicating lamps.
(c ) 1 no125A TP,25 KA,415V TP MCCB TM
Based with O/L,S/C,E/F protection with MFM
,125/5A CTS,CL-0.5 10VA, spreader
link,Rotary handle,Aux. contact,Shunt release
240V AC,2A SP MCB, Neutral link --R-Y-B
indicating lamps.
( d ) 5 no 80A FP,25 KA,415V FP MCCB TM
Based with O/L,S/C protection with Volt meter
and Ameter with selector switch ,60/5A
CTS,CL-0.5 15VA, spreader link,Rotary
handle,Aux. contact,Shunt release 240V
AC,2A SP MCB, Neutral link --R-Y-B
indicating lamps.
( f ) 3 Nos. 63A FP MCB,10KA
( g ) 3 Nos. 40A FP MCB,10KA
( h ) 2 Nos. 40A DP MCB,10KA
( i ) 2 No. 25A DPMCB, 10KA
2.5.2 1.00 CAFTERIA PANEL 110123.00 No
(i ) 1 no.200A FP,35 KA,415V FP MCCB TM
Based with O/L,S/C ,E/F protection, with
spreader link,Rotary handle,Aux.
contact,Shunt release 240V AC,2A SP MCB,
Neutral link --R-Y-B indicating lamps.
(iii) Digital type 3 phase Multi function Meter &
KWH METER CL-0.5 with RS-485 PORT,
200 Amps, 415 V, FP ALUMINIUM Busbars
with Heat shrinkable color code insulation
sleeves.( 1 sqmm = 0.8Amp )
( i ) 4 nos. 63A FPMCB,10kA, C Curve
( ii ) 1 no. 40A FPMCB,10kA, C curve
( iii ) 40A DPMCB,10kA, C curve
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type,40KVAR, Voltage Rating 415V
A.C.,3-Phase , APFC Panel Incomer Switch
of MCCB type Icu=Ics=25KA at 400/440
Volts, with OC, SC, internal earth fault
protection,Copper tinned insulated
Busbar,Cubical panel should be indoor type
with IP 43 and IK 10,Metalized polypropylene
film tye3-phase 440Volt Capacitor,De tuning
Reactor for each capacitor,Panel having Short
Circuit and Overload protection,Each step
2.5.3 1.00 Capacitor having suitable MCB with Sc, 163668.00 No
OL,Each stage having Stage Contactor
(Capacitor load rating),PF regulator master
controller having 6-stage with LCD display,
Rs 485 Communication port, Indication LED
Lamps for main incomer and ON-OFF for
each capacitor bank,MS Chanel for Floor
mounting, Cable entry as per site
situation,Cooling fans for panel having 5-
steps ( 2-3-5--5-10-15 kvar heavy duty can
type capacitors ) with suitable rating of
Incomer MCB, CT. as per approved by
engineer incharge.
Supplying & erecting approved make IP
grade Company fabricated Timer Panel of
following capacity for switch On-Off street
lights on time scheduling basis made from
16G CRCA sheet duly epoxy power painted
2.5.4 inside and outside with hinged doors and
locking arrangement consisting of suitable
size of 4 Pole MCB and 4 pole contactor (cat-
III)with analog time switch, auto manual
switch of same make and suitable input and
output Bakelite terminals and with door
earthing approved by Engineer in charge.
MCBDBs and MCBs
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
2.7 having 10 KA breaking capacity & confirms to
IS : 8828 in existing box having following
Providing & erecting 415 V MCB Four Pole
2.8 for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity
Providing & erecting 415 V MCB three Pole
2.9 for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity
2.1 4.00 Sheets steel powder coated enclosure 175.00 E.a.
suitable for incorporating One/Two nos. MCB.
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral
link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to
be used) suitable for
2.11 (A) single phase incoming and horizontal
single phase outgoing
(b) sheet steel double door (IP-43)
2.11.1 4.00 (i)4 way ( concealed manner ) 747.60 E.a.
2.11.3 2.00 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.11.5 40.00 (iv)12 way ( concealed manner ) 1773.60 E.a.
(B) three phase incoming and single phase
2.12 horizontal type outgoing Per phase isolation
(b) sheet steel double door
2.12.1 3.00 (i)4 way ( concealed manner ) 2779.20 E.a.
2.12.3 4.00 (ii)6 way ( concealed manner ) 3462.00 E.a.
2.12.5 2.00 (iii)8 way ( concealed manner ) 4054.80 E.a.
2.12.7 1.00 (iv)12 way ( concealed manner ) 4603.20 E.a.
Providing and erecting Sheet Steel powder
coated Vertical MCB distribution board
(VTPN) - flush / surface mounted double door
(IP54) fitted with insulated copper busbar,
2.13 isolated neutral link, earth bar and DIN rail,
confirming to IS 13032 and BS 5486-1986,IP-
54 suitable for 63/100 AMP TPN MCCB +
RCCB as incomer and three phase outgoing
as per following .(The DBs should be used of
same company of MCB to be used)
5.00 (A)4 way outgoing 9925.00 E.a.
Supplying & erecting Sheet Steel powder
coated Cable end termination Box to be
mounted on Top or Bottom of the MCB
Distribution Box for housing/covering Extra
wires & Cables, suitable for following size of
2.14.1 2.00 (G) Three Phase 8 Way ( concealed manner ) 819.60 E.a.
2.14.2 1.00 (G) Three Phase 8 Way 683.00 E.a.
(H) Three Phase 12 Way ( concealed manner
2.14.4 1.00 (H) Three Phase 12 Way 789.00 E.a.
providing and erecting Approved make
ELCBs / RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for
2.15 operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all
advance feature & do not incorporate any
electronic component. for following Max.
rating erected as directed
Providing and erecting Approved make
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for
2.16 operation on 3 phase and neutral 415V,50Hz.
having characteristic of quick action & tripping
with all advance feature & do not incorporate
any electronic component for following Max.
rating erected as directed.
2.00 (ii) 40Amps. FP 2611.00 E.a.
Providing and erecting metallic vitrified danger
2.17 22.00 notice board as per language suggested by 69.00 E.a.
engineer incharge for MEDIUM VOLTAGE
installation to be erected as per IS-2551.
Providing & erecting Medium Voltage Danger
2.18 15.00 Notice Board sticker as per language 26.00 E.a.
suggested by engineer incharge of standard
size as per IS-2551
SUB - TOTAL OF Switchgears , Panel and
Follow IS code :3043 is the guideline for the
Providing and erecting required size HOT
3.1 250.00 deep Galvanised iron strip for earthing of H.T. 77.00 KG
, OCB/ ACB/ Transformer LT panel board,
Motors etc. using proper clamp.
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc.
using copper clamp.
3.3 10.00 Providing and erecting Annealed bare Copper 787.00 KG
wire 8 to 16 SWG.
3.4 90.00 Providing and erecting HOT deep Galvanised 77.00 KG
iron strip wire 8 to 16 SWG.
Supplying & erecting earth pit of minimum
bore dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe dia
of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of
12mm with constant ohmic value surrounded
by highly conductive compound with high
3.5 charge dissipation suitable for following type
of applications with chamber and heavy duty
cover.(approved make OEM has to submit
test certificate) & having back filling
compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 W/ meter testing
as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing
compound should be capable to retain
moisture for long time Necessary test report
must be submitted.
(a) For Electrical Installation up to 440V in
3.5.1 4.00 normal soil 4546.00 E.a.
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
(c) For Electrical Installation covering
Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer
3.5.2 3.00 System(like Automation, SCADA) i.e 8551.00 E.a.
independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Supply, installation,testing and commissioning
of Chemical Earthing with UL Certified
17.2mm Dia. X 3000mm Long 254 Micron-
Copper bonded M.S. Rod manufactured as
3.6 3.00 per IEC 62561-2 with 25Kg Bentonite powder 12230.00 No
plus " U " bolt rod clamp complete with
Lockable high performence chamber suitable
& tested for 5000T capacity with SS
Hardware.or equivalent
SUB - TOTAL OF Earthing
4 CABLES, Cable Termination and cable
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Aluminium
4.1 conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
of following size of cables
Providing and erecting XLPE (IS:7098)(I)-88
ISI armoured cable multistrand / Solid
4.2 Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
Providing and erecting XLPE (IS:7098)(I)-88
ISI armoured cable multistrand Aluminium
4.3 conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
of following size of cables
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
4.4 unarmoured copper cable 1.1 KV grade to be
erected as directed of following size.
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand / Solid
4.5 Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing
trench / pipe at road crossing or floor of
following size of cables.
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
at road crossing or floor of following size of
110.00 (C) 4 core 10 Sq. mm 670.00 Mtr
Making trench in soft soil of suitable width of
4.7 325.00 90 cm deep for laying cable or locating the 55.00 Mtr
fault all over the run and back filling the same
and making the surface as normal ground.
Covering of cable with second class bricks or
cement tiles laid cover the cable crosswise &
4.8 300.00 also on both sides with covering of 7. 5 Cm. 139.00 Mtr
layer of sand above & below cable (16 bricks
( A )Making trench in Hard Murrum / Tar Road
of suitable width of 90 cm or required depth
4.9 15.00 for laying any size of cable or locating the 74.00 Mtr
fault all over the run and back filling the same
and making the surface as normal ground.
4.1 5.00 (B) If additional machinery like hammer driller 354.00 Mtr
or JCB use [Add]
Drilling the road without breaking the road
4.11 surface (Asphalt) for laying of cable for
feeding power supply by making up to
following size of holes at both ends complete.
4.11.1 5.00 (A) Up to 100 mm bore dia 488.00 Mtr
4.11.2 5.00 (B) Up to 150 mm bore dia 610.00 Mtr
Supplying following size of Light duty “A”
4.12 Class G.I . Pipe & erecting as directed by
Engineer-in-charge.
20.00 (A) 25 mm dia 171.00 Mtr
Providing & laying. R.C.C. Hume pipe for
cable to be laid 90 cm. below ground across
4.13 the road crossing or on floor with necessary
material in an approved manner and making
the ground as per original.
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
4.14 necessary connecting accessories of same
material at required depth in existing trench
for laying of cable. below ground / road
surface for enclosing cable
4.14.1 90.00 (A)50 mm outer dia 62.00 Mtr
4.14.2 360.00 (B)63mm outer dia 73.00 Mtr
4.14.3 50.00 (C))90 mm outer dia 95.00 Mtr
4.14.4 110.00 (D)120 mm outer dia. 136.00 Mtr
Providing & laying approved make ISI
marked Rigid PVC pipe having 6Kg / cm2
4.15 (Class-3) to be erected at road crossing on or
floor as directed for laying of cable. The pipes
as following size of dia & weight per 6 mtr.
4.15.1 15.00 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124.00 Mtr
4.15.2 10.00 (F) 110 mm inner Dia. (11.63 Kg/6 RMT) 234.00 Mtr
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
4.16 insulated armoured cable complete with out
going tails, insulating tape etc for following
size of cables.
Providing and, fixing heavy duty flange type
brass double compression type cable gland
4.17 with rubber ring for PVC insulated armoured
cable complete with out going tails, insulating
tape etc for following size of cables.
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following
4.18 size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
Solder less crimping type Copper lugs
conforming to IS suitable for cable of following
4.19 size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
SUB - TOTAL OF Cables,Cable
Terminations & Cable Trenches
5 Light Fixtures & Fans
Supply , Installation, testing and
commissioning of pre-wired, LED fitting/post
top luminaries etc of all types, complete with
all accessories and tube etc. directly on
ceiling/ wall, including connection with 1.5 sq.
mm FRLS PVC insulated, flexible, copper
conductor, single core cable with flexible
conduits and coupler and earthing etc. as
required. Note:- The LED Light fixtures
should comply all international standards third
party ( LM 79 for complete fixture, LM 80 for
individual LED ). The Manufacturer /
Channel Partner of the Manufacturer has to
submit 4- Years unconditional free
Replacement Guarantee for complete fixture.
Supplying and erecting LED indoor fittings
with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing
used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with
5.1 company mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,CCT
3000 K to 6500K, Luminaire efficacy>
lumens/watt , LED driver efficiency > 85 %(
fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
( A ) Tube Light with integral / non integral
5.1.1a 2.00 (iii) 18-20 Watts, Surge - 2KV,IP-20, 293.00 No
conventional 4 feet
5.1.1b 95.00 (v) 36-40 Watts, Surge-2 KV, IP-20, 530.00 No
conventional 4 feet
(B) LED Panel Light with provision for Plane
5.1.2 front frame with translucent cover fixed to
housing complete.IP20. Round /Square
Recessed or Surface mounted.
5.1.2a 4.00 (a)up to 8 Watts,4" x 4", Surge-2 KV 271.00 No
5.1.2b 150.00 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462.00 No
5.1.2c 75.00 (iv) 18 to 20 watts, 8" x 8", Surge- 2 KV 607.00 No
5.1.3 (F) Spot Light 425 Lumens, Surge-2KV
5.1.4 10.00 (H) Mirror Light 9 Watts, wall mounted 309.00 No
minimum 1 feet long
Providing and erecting PVC body surface or
pendent mounting LED Bulk type 9 watt
Lighting Fitting with electronic driver. And
lumen output from luminaire 720lm , input
voltage range 90-300VAC , 50Hz cool
white(3000 to 6500k), inbuilt driver, -20degC
to +60degC working temperature, AL frame
with Beam Angle 120deg
Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt
A.C. 50 Hz 1200 mm sweep complete
having 3blades with aluminium blades with
canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer
Supplying & erecting approved make low
5.4 28.00 noise decorative exhaust fan having size 1687.00 No
200mm with 1350 RPM with square frame
ABS body with inbuilt lowers & square frame.
Supplying & erecting approved make 230 V
50 Hz Operating Voltage low noise decorative
5.5 Roof Mounting Exhaust fan having square
frame and Slitted guard with mounting
accessories, necessary pipings and fittings.
Supplying & erecting fan hook box of 10 mm
M.S. round bar bounded to the RCC bars up
5.6 240.00 to 50mm length each side and pierced 107.00 No
through a 16 Gauge M.S. box / Heavy Duty
PVC box complete erected concealed in
Ceiling with necessary finishing.
5.7 240.00 Providing 2.5mm.thick laminated acrylic sheet 18.00 No
to cover the fan hook or Fan box.
Supplying and erecting 19 / 20 mm. nominal
bore Medium Class M.S. Pipe down rod
5.8 240.00 erected duly painted for fan complete with 107.00 Mtr
proper insulation without leakage and
Supplying & erecting single phase approved
make industrial exhaust fan suitable for
medium duty ring mounted low noise
operation suitable for medium duty having
following dia size and maximum speed in
5.1 6.00 Providing suitable M.S. louver shutter of the 365.00 No
Supplying & erecting electro galvanised G.I.
wire micro mesh jali cover of grade
5.11 5.00 required size with suitable wooden frame duly 628.00 Sqmtr
fitted in wall outside of exhaust fan for insect
SUB - TOTAL OF Light Fixtures & Fans
6 External lighting
Supply , Installation, testing and
commissioning of pre-wired, LED fitting /post
top luminaries etc of all typesof external lights,
complete with all accessories and tube etc.
directly on pole / pole bracket , including
connection with 1.5 / 2.5 sq. mm FRLS PVC
insulated,3 core flexible, copper conductor,
with flexible conduits and coupler and
earthing etc. as required.
Supplying and erecting LED street light /
Flood light fittings with High power White
LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High
pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver
efficiency > 85 %.( fittings required LM-79 &
LM-80 certificates)(NOTE: Below description
have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may
select any wattage capacity between the
(A) Street Light (IP-65), Surge protection -4KV
/5000K integral and 10 kv non integral ,Light
6.1.1 must have 440VAC line supply protection. It
should withstand 48 hours for 440VAC line
(f) Above 60 watts to 90 watts ( Required 72w
(B) Flood Light (IP-65), Surge -4KV/5000K
6.1.2 ,Light must have 440VAC line supply
protection. It should withstand 48 hours for
440VAC line supply
6.1.2.a 4.00 (c) Above 60 watts to 90 watts 6028.00 No
6.1.2.b 4.00 (v) above 120 to 160 watts 8370.00 No
6.1.2c 2.00 (vii) above 200 to 250 watts 10711.00 No
(C) Post Top Lantern Decorative LED fitting
comprises of Copper dust finish cast
6.1.3 aluminum spigot and spun aluminum canopy
fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and
accessories wired upto terminal block.IP
4.00 (b)32-40W ( Required 40w ) 4772.00 No
Supply of approved make frp/grp pole having
followiing specifications :
FRP/GRP pole made by centrifugal moulding
process using thermoset resin
polyester/epoxy resin system having minimum
glass content 45.0%.The pole should be in
one pieceand tapered round in shape,having
smooth outside surface finish and should be
totally fre from corrosion as well as non
conductive and shock proof. Pole should be
6.2 provided with FRP/GRP base bracket dully
fabricated from metal(M.S) and dully claded
with FRP/GRP material to avoid any metal
exposer and painted with PU paint.
Pole should mechanical properties i.e
Specfic gravity (ASTM D 792) 1.3‐1.8 Kg/m3,
2. Glass Content % by weight (ASTM D 2584)
45.0 ‐55.0%, 3. Water absorption (ASTM D
570) <0.5%, 4. Tensile Strength(ASTM D 638)
200+/‐50Mpa, 5. Flexural strength (ASTM D
790) 250+/‐50Mpa, 6. Compressive Strength
(ASTM D 695) 200+/‐50MPa, 7. Yeild
Strength(ASTM D638) 250 +/‐50MPa.
Pole should be flame retardant as per IS
6746.Resin used shall be UV resistance and
pigmented. Pole should be painted with first
coat of epoxy primer and then two coat of
highly weather resistance polyurethen paint to
ensure proper addhesion of the
paint.Minimum thickness shall be 80 to
micron.Defelection of the pole shall not
exceed more than 10.0 % of the length of the
pole for the given load.Pole should be
generally made as per the dimensional
data,performance criteria and some
interchagebility features of poles as per the
standard ANSI C123.20 latest version of
ASTM D 923/01 including cable termination
box with necessory accessories.The size of
pole and type of installation with foundation
Anchor Base & Internal junction box as per
the manufacturer details and site requirement
. The cost of 6 Mtr & 10 Mtr pole's Flood light
mounting ring is included.
(3) 'B' class (Heavy Duty) frp/grp pole
suitable for base plate mounting
[D] Overall Length of 6.0 meter, Average
thickness : 7mm, Top/Bottom Outside Dia.
76/176mm +/‐2.Weight of Pole 25.0 Kg
14.00 approx. (Without base) Metal Anchor Base 16815.00 E.a.
dully frp claded (Size : 340 Ø * 12mmthk
Mounting hole PCD 285mm * 6 nos. of 20 Ø
Providing FRP/GRP arm bracket of having
6.3 15˚ arm with 50 mm OD pipe *5 mm
thk,1000mm long from pole centre
6.3.1 14.00 (a) Single arm bracket 1882.00 No
6.3.2 1.00 (b) Double arm bracket 2390.00 No
Supplying & erecting sintex make SMC
press moulded composite FRP. loop-in, loop-
out approx. 2mm thick box complete with
bakelite connector strip 4way & hinged doors
having locking arrangements with mounting
clamp with nuts, bolts & washers suitable for
erection on wall ( c)150mm x 125mm x
Providing cement concrete.for foundation or
for concrete filling in 1:2:4 ratio with 20 to
6.5 11.00 mm stone metal duly plastered with 5077.00 CU Mtr
necessary curing for pole muffing or any other
B' class galvanised iron pipe 32 mm outside
dia 45 cms long duly welded on 20 cms x
cms x 3 mm thick M.S. base plate, erected on
wall or corner for mounting street light
luminaire with necessary hardware materials
SUB - TOTAL OF External Lighting
Supplying & erecting approved make
Automatic liquid level controller 6A. with
7.1 1.00 sensor testing as per instruction of Engineer 2332.00 Job
in charge on site complete with wiring
connection with existing wires , with copper
conductor from pump to upper and lower tank.
Supplying and erecting Flexible PVC
7.2 insulated multistrand multicore 1.1 kv grade
ISI marked copper wires of following size to
be erected as directed.
90.00 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected
7.3 with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as
Providing & erecting water cooler having
storage capacity 150 Ltr. & cooling capacity
150 Ltr.per hour @ an ambient temp of 45˚ C.
The outlet temp. of the water should drop by
15˚C within a hour, The water cooler should
7.4 4.00 be comprising of hermetically sealed 55340.00 No
compressor, fan motor, condensing unit,
water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with
necessary inlet & outlet connection. The body
of water cooler will be made from Stainless
Supplying and erecting water filter cum
7.5 4.00 purifier with ultra violate technology. 5371.00 No
(Aquaguard / waterdoc model or equivalent
symphony/ crystal/videocon model)
Providing & erecting open well horizontal
mono block pump set with cast iron body,
complete for three phase submersible motor
[D] For 5 HP 3 phase open well horizontal
7.6.1 2.00 mono block pump set suitable for 1350 LPM 18561.00 No
to 310 LPM @ 10 to 42 Mtr head suitable for
50/65 mm dia delivery pipe
[C] For 3 HP 3 phase open well horizontal
7.6.2 1.00 mono block pump set suitable for 85 LPM to 15552.00 No
270 LPM @ 11 mtr to 33 mtr head suitable for
50/65 mm dia delivery pipe
Supplying & erecting approved make motor
control cubical panel (Direct - on - line) made
from 16 G. CRCA sheet duly epoxy powder
painted inside and outside with hinged doors
and locking, arrangement consisting of
suitable size of ON- OFF isolator (AC -
3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y - B
7.7 phases, overload relay, Automatic water level
controller, Ammeter, Voltmeter each with two
way selector switch incoming, wires duly
socket crimped, main contactor & overload
relay, start - stop push buttons, to be erected
on angle iron frame grouted on wall as
directed. The isolator, overload relay &
contactors will be of L & T, Siemens or BCH
2.00 (a) DOL up to 5.0 H.P. 7646.00 No
Supplying & erecting approved make 3 phase
motor control cubical panel ( Star - Delta)
made from16 G. CRCA sheet duly painted
with epoxy powder painted inside and outside
with hinged doors and locking arrangement,
consisting of suitable size of ON- OFF isolator
(AC - 3/23 duty) main fuses, single phasing
preventer cum water level. Guard (Complete
unit), Toggle switch to by pass Single phase
7.8 preventer cum WLG, indicating lamps for R-
Y- B phases, over load relay, Automatic water
level controller, Ammeter & Voltmeter each
with two way selector switch incoming wires
duly socket Crimped, Panel to be erected on
angle iron frame grouted on wall as directed.
Star Delta & main contactor, overload relay,
thermal / Electronic Star delta cutoff timer,
start - stop push buttons. The isolator
overload relay & contactors of L& T, Siemens
or Cuttler Hamer make only. Panel to be
erected on angle iron frame ground on wall.
1.00 (A) S/D up to 7.5 H.P. for sewerage pump in 12865.00 No
Charges for doing liasioning work for
obtaining the necessary clearances from the
Electrical inspector / competent Authorities for
the total Electrical installation,co-ordinating
with various agencies. All necessary
drawings, calculations, test certificates, etc.
7.9 1.00 as required by these authorities shall be 41000.00 No
prepared and furnished by the EPC Vendor.
Any modification/rectification as required by
these authorities shall be carried out by
theEPC Vendor at free of cost. The fees
required to be paid to these authorities for
inspection shall be borne by Owner on
production of documentary evidences.
SUB - TOTAL OF MISC. Work
Final specification and block diagram shall be
submitted by CCTV camera system vendor.
Supply,installation,Testing and
Commissioning of 5MP, 1/2.7"CMOS,IP Fix
Dome camera, 2592x1944@30fps IR
2592x1944@30fps IR Range:30M,120dB
WDR Triple-Stream (Main/Sub/Third),Built-in
Mic, SD Card Slot up to 256GB, Multiple AI
Support,Metal, IP67. Built-in-mic , 3.6mm
Color 0.003lux @ F1.6(AGC ON) ; B/W 0 lux
@ IR ON, H.265+/H.265/H.264 Video
compressions, Privacy masking Off/On (4
8.1 20.00 Zone, Rectangle), Face Recognition (FR), 9208.52 No
Human & Vehicle Detection (PD & VD),
Perimeter Intrusion Detection (PID),Line
Crossing Detection (LCD), Cross Counting
(CC), Stationary Object Detection (SOD),Heat
Map (HM), Crowd Density Detection (CD),
Queue Length Detection (QD), Rare Sound
Detection (RSD), Main Stream
@30fps,ONVIF( Profile S/G/T)
CE,FCC,RHOS,BIS, ISO9001 certified,
DC12V / POE ( IEEE802.3af)
Supply,installation,Testing and
Commissioning of 5 MP IP Fix Bullet, 1/2.7"
CMOS,2592x1944@30fps IR Range: 30M,
120dB WDR Triple-Stream (Main/Sub/Third),
Built-in Mic, SD Card Slot up to 256GB,
Multiple AI Support, Metal, IP67,Built-in-mic
3.6mm , Color 0.003lux @ F1.6(AGC ON) ;
B/W 0 lux @ IR ON, H.265+/H.265/H.264
Video Compressions, Privacy masking Off/On
8.2 6.00 (4 Zone, Rectangle), Face Recognition (FR), 9114.87 No
Human & Vehicle Detection (PD & VD),
Perimeter Intrusion Detection (PID),Line
Crossing Detection (LCD), Cross Counting
(CC), Stationary Object Detection (SOD),Heat
Map (HM), Crowd Density Detection (CD),
Queue Length Detection (QD), Rare Sound
Detection (RSD), Main Stream
@30fps,ONVIF( Profile S/G/T)
CE,FCC,RHOS,BIS, ISO9001 certified,
DC12V / POE ( IEEE802.3af)
S.I.T.C. of 32CH,4SATA NVR having
Through put: 320 Mbps incoming / 320Mbps
outgoing, 4SATA interfaces, up to 12TB
connect camera at up to 12MP, 2 x RJ45,
2HDMI Port,1 VGA Alarm input/out : 16in /
1out, Play back 1080P: 480fps,Max.
16CH,Audio: G.711a,G.711u
Video:H264/H265,WEB IE 10/11,Safari V12.1
above, Edge V.79 above,FireFox V.52 above,
cloud storage ( Dropbox & Google
Drive),Onvif ( profile S/G/T) USB2.0*1 front,
USB3.0*1 Rear,Face Detection &
recognition,Vehicle & Pedestrian
Detection,Perimeter intrusion detection,Cross
counting,Heat Map,crowd density
detection,Object detection,Video
Tempering,QueueLength detection, License
plate detection,Rare sound detection,Region
Entrance & Existing, CE,FCC,RHOS,BIS ,ISO
9001 certified.
8.4 2.00 Supply Installation Testing & Commissioning 25150.00 No
of 8TB Surveillance Harddisk
Supply, Installation, Testing and
Commissioning of 43 inch, Professional LED
Display Cum Commercial TV with Android
& Inbuilt play store, UHD resolution, 400 nits
brightness, It's 24*7 usage, 50,000 hours life,
3 years warranty, Android 11 with inbuilt play
store, Inbuilt wifi, Landscape / Portrait mode,
Inbuilt Bluetooth, 2 GB / 16 GB Memory,
Inbuilt SOC with HDMI cable
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected
8.6 with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as
CAT 6 UTP Cable
Supplying & erecting approved make LAN
8.7 cable of following size in existing pipe as per
8.8.1 1.00 Supply, Installation, Testing & Commissioning 12053.57 No
of 9U wall mount rack.
8.8.2 1.00 Supply, Installation, Testing & Commissioning 12840.00 No
of weather proof outdoor rack.
SITC of 24 x 10/100/1000BASE-T PoE ports
4 x Gigabit RJ45/SFP Combo ports Advanced
L2 switching and security features L2+ Static
8.9 1.00 Routing Optional “standard mode” or 31680.00 No
“surveillance mode” management user
interface 193 W PoE budget (Including Five
year free maintenance with guarantee)
SITC of 8 x 10/100/1000BASE-T PoE ports
x Gigabit SFP ports Advanced L2 switching
and security features L2+ Static Routing
Optional “standard mode” or surveillance
mode” management user interface 65W PoE
[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Supply, Installation Testing & Commissioning
5 Mtr. HDMI Interface Cable as per the
8.11 1.00 detailed Specifications supports transmission 820.00 No
of 4K Signals as per the detailed
Supply, installation, fixing, testing and
commissioning of PVC Junction box for CCTV
8.12 26.00 Camera, IP65, outdoor application. Junction 440.00 No
Box size will be as per vendor's requirement
and site condition.
SITC of Patch Panel Cat 6 UTP Keystone
8.13 1.00 Type- 24 Port-Fully Loaded (Including Five 4357.00 No
year free maintenance with guarantee)
8.14 26.00 SITC of Jack Cat 6 Keystone UTP (Including 160.00 No
Five year free maintenance with guarantee)
SITC of CAT6 UTP 24AWG PATCH
8.15 26.00 CORD:1M,Plug 30U' Snag less (Including 155.00 No
Five year free maintenance with guarantee)
SUB -TOTAL OF CCTV SYSTEM
9 FIRE DETCTION & FIRE ALARM SYSTEM
Supply, Installation, Testing & Commissioning
of Microprocessor based Networkable
Analogue Addressable Fire Alarm Control
Panel. The Panel shall be compliant with
EN54-2, EN54-4 and approved by LPCB. The
Fire Alarm Control Panel shall have inbuilt
loops and expandable capacity upto 8 loops.
The Panel must have Full colour 800 x
LCD with resistive touch screen and
automatic backlight dimming. The Panel must
also have the capability to take Addressable
Intelligent Wired and Wireless Devices on
same loop. Each loop shall have a capacity of
127 analogue Addressable devices and
Base sounders/Base Sounder Beacons. The
panel shall have an event log of minimum
10,000 events @ 1 second resolution,
Filterable and Printable. The Panel shall have
Three access levels. Panel shall support upto
5000 Cause & Effects entries, with upto
20,000 inputs controlling & 20,000 Controlling
9.1 1.00 outputs across the network. The Panel shall 203348.75 No
have capability for Peer to Peer networking
through RS485 network card. The Panel must
have 4 inbuilt programmable sounder circuits,
each circuit rated at 2.5A.The Panel must
have inbuilt 3 programmable inputs and
inbuilt programmable relay outputs. The Panel
shall have up to sub-addressable
programmable Inputs/Outputs via optional
RS485 COMMS serially connected
expansion cards. The Panel shall have 240 V
AC power supply along with automatic Battery
Charger. The Panel shall be fully expandable
via common plug in loop driver boards. The
user shall have a choice of using the panel
with 5.25 Amp or 10.25 Amp power supply
unit which is inbuilt in the FACP and should
be approved to EN54-4. The Panel shall have
configurable via USB port to PC or memory
stick. The Panel shall have dedicated RS232
serial port for optional printer. Approved by
Supply, Installation, Testing & Commissioning
of Active Repeater Panel to be integrated with
Fire Alarm Control Panel,larger display Full
9.2 1.00 colour 800 x 480 LCD with resistive touch 86692.75 No
screen and automatic back-light dimming and
the status of any Fire/Fault of Integrated Fire
Alarm Panels, Panel should compliant with
EN54-2, EN54-4 and Approved by LPCB
SITC of Analogue Addressable Multi- Sensor
which is fully compatible with Analogue
Addressable Protocol,having removable high
performance chamber with Twin fire LED's
allow 360 degree viewing, User selectable
9.3 90.00 sensitivity modes 1% to 4.5% obs/m, 3597.20 No
Incorporate Optical and dual Heat elements,
lock mechanism (sensor to base),
Electronically addressed, Pulsing/non-pulsing
controlled from panel. Approved by LPCB &
VdS. (Including Five year free maintenance
with guarantee)
SITC of Analogue Addressable Multi- Heat
Sensor which is fully compatible with
Analogue Addressable Protocol,having
removable high performance chamber with
Twin fire LED's allow 360 degree viewing,
User selectable sensitivity modes 0 to
10.3 40.00 degree Celsius, Incorporates Fixed 3498.30 No
Temperature and Rate Of Rise Heat
elements, lock mechanism (sensor to base),
Electronically addressed, Pulsing/non-pulsing
controlled from panel. Approved by LPCB
(EN54: Part 5) (Including Five year free
maintenance with guarantee)
Supply, Installation, Testing & Commissioning
of Analogue Addressable Single Input
Module. which Includes a single monitored
input, flying leads for easy installation.
Electronically addressed, Approved by LPCB
Supply, Installation, Testing & Commissioning
of Analogue Addressable Single Output
9.5 5.00 Module . which Includes a single output, flying 4688.55 No
leads for easy installation. Electronically
addressed, Approved by LPCB & Vds.
SITC of sensor common mounting base,
includes stainless steel contacts, slim profile -
9.6 130.00 only 8mm, quick connection via square cable 354.20 No
clamps, facility for remote indicator, Approved
by LPCB (Including Five year free
maintenance with guarantee)
Supply,Instllation,Testing and Commissioning
of Fault isolator Module capable of monitoring
9.7 12.00 shorted loop circuit and automatically restore 2477.10 No
communications when shorted conditions are
corrected (Including Five year free
maintenance with guarantee)
Supplying, installation, testing &
commissioning of response indicator on
9.8 8.00 surface/recessed MS Box having two LED, 193.20 No
metallic cover complete with all connections
etc as required.
SITC of Manual Call Point approved to EN54-
9.9 12.00 11:2001, Approved by LPCB Easy to install, 4191.75 No
push-fit wiring terminals (Including Five year
free maintenance with guarantee)
SITC of Analogue addressable loop powered
Base Sounder, variable sound output 50 ~
dB(A) (±2 dB(A)) output at 1 metre, 51 user-
selectable tones (all tones EN54-3
compatible), Auto shutdown feature prevents
noise-pollution, Approved by LPCB & VdS
(Including Five year free maintenance with
Supplying & laying of 2x1.5 sqmm fire alarm
armoured cable, 600/1000V rated with
9.11 1250.00 annealed copper conductor having XLPE 135.70 Mtr
insulation, steel wire armouring & FRLS
outer sheath complete as required.
SUB -TOTAL OF FIRE DETECTION&
10 PASSENGERS ELEVATOR
Supply ,installing , commissioning and testing
of M.R.L. Passengers Elevator 8 to
passengers as per R & B S.O.R ( Category -
Premium ) having following specifications:-
Ground+ 5 upper floor
Supplying, Erecting, Testing &
Commissioning the passenger lift having
following main features:
[1] GEAR LESS LIFT DRIVE comprising of
High Starting torque Lift 3 phase 440 V
A. C. Permanent Magnet Synchronous motor
of proper rating with high efficiency shall be
[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback
closed loop system shall be used for lift car
and door operation which shall be full
collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/
Down Contactor with overload and phase
reversal relay and safety controls.
[3] Car with M S platform with bracings of
adequate size and to sustain the impact load
cabin + passenger with safety factor of fire for
steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be
S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of anti
skid PVC with choice of colour of engineer in
charge. Car doors shall be of stainless steel
grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will
also be S.S. 304 finished with emergency
stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel
buttons and all floor switches must be with
brail language as per lift act.
[4] All landing doors must be fire rated for
hour shall be fully automatic centre opening/
telescopic opening made of hairline finish
steel grade of 304 with key holes and infrared
curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall
be provided. Also, Emergency Light & Fan
should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-
down arrow along with floor position indicator
shall be provided inside the car and at all
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be
provided accordingly of passenger capacity
with Manual Rescue Operation ( Manual
Cranking Facility).
[9] Audio visual indication in the lift car
showing over loading shall be provided such
that doors kept open till excess load is
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music
shall be provided in lift car.
[13] Self diagnostics system for operational
and safety parameters shall be provided in
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the
lift machine room and monkey ladder for lift pit
should be provided by the lift agency, along
with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in charge.
[17] Permanent wiring with necessary safety
devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator
in circuit for lift machine room and lift well
with proper numbers of light points, with
fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power
Supply shall be made available by
department in lift machine room. Necessary
Earthing as per Lift Act/Rules shall be
arranged by Lift Agency.
[18] Any civil/ electrical works for additional
and alteration in lift shaft and machine room
related to erection of lift shall be made by lift
agency without any extra cost. (granite/marble
fixing around all landing door openings are
not in lift agency’s scope.)
[19] Agency has to provide all working
drawings and documents and liaison services
for obtaining all necessary permission from lift
inspector and other authorities.
[20] acrylic transparent licence/display A4 size
holder in lift car
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground
4.carrying out third party lift inspection
during/after lift erection and provide report by
third party authorized by concern licensing
authority 5.agency has to provide third
party insurance upto completion of free
maintenance period and submit the document
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto
Glow type clearly visible when view from
[22] For Physically Handicapped person Full
Length Handrails of hairline finish steel grade
of 304 should be provided at appropriate
height on the Rear & Side Wall Panels in Lift
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb
required for lift is in scope of work which
rating is sugested by CEICED Department
(electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION
OF LIFTS for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS
Serial Communication mode including
Regenerative power efficient operation,on site
programming facility, Anti nuisance, Pte-
opening, BMS/RMS with necessary online
real time monitoring system having necessary
connectivity for remote monitoring & other
suitable supporting hardware & software
devices to fulfil the purpose.
2. Floor Indication LCD Display with call
registration & brail mark with arrival gong and
hall lantern & TFT Screen in the car with MP3
Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for
car and all Doors, All landing doors must have
fire rating up to 2 hours and car door must
have multi-level crisscross beam door
4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and
Each elevator are equipped with remote
monitoring system.agency has to provide
mobile app and user id and password for
8/10 passengers Ground + 5 upper floors
with Rated Speed of 1.0 m/sec -
(C) With General PLUS ADDITIONAL
2.00 SPECIAL FEATURES attached herewith. 1759697.00 No
SUB TOTAL of Passengers Elevator
Annual Comprehensive Maintenance of
the Electrical /ELV / passenger elevators
for 1 Year after completion of DLP ( 1-
Annual comrehensive maintenance charges
for 1-Year of DLP + ONE year for Entire
Electrical and ELV system and passenger
elevators installed at site including with all
genunine spares from OEM, Annual
comprehensive maintenance period starts
after completion of Defect Liability period of
project. Payment for CM AMC shall be made
on quarterly basis & after completion of each
11.1 1.00 DLP-1 Year Free Job
Annual comprehensive maintenance Charges
11.2 1.00 for First year After Guarentee / Defect Liability 255358.46 Job
SUB-TOTAL OF Annual comprehensive
MAINTENANCE CONTRACT of Electrical,
ELV system and passenger elevators
I. No. Qty Items Unit Rate Per Amount
FIRE FIGHTING SYSTEM
Design,Supply,installing,testing and
commissioning of FIRE HYDRANT WORKS
Internal / External Hydrant
Supplying, Installation, Testing and
Commissioning of electric driven main
Hydrant fire pump and Sprinkler pump
suitable for automatic operation and
consisting of following: complete in all respect
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical
seal to ensure a minimum pressure of
2.00 kg/sq. cm. at highest and farthest outlet at 230151.00 Set
specified flow of 2280 lpm at 65 Mtr. head
conforming to IS 1520.with suitable size of
footvalve confirming to IS 4038, Pressure
rating PN2 , preventing entry of foreign body
to pump through suction pipe, perfectly flat
seating surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor,
TEFC, suitable for opertion on 415 volts,
phase 50 Hz. AC with IP 55 class protection
for enclosure, horizontal foot mounted type
with Class - 'F' insulation, conforming to IS-
c) M.S. fabricated Common base plate,
coupling, coupling guard, foundation bolts etc.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
The pump shall be capable of giving not less
than 150% discharge at ahead not less than
65% of the rated head.
Supplying, Installation, Testing and
Commissioning of electric driven
1.1.2 1.00 pressurisation pump suitable for automatic 61717.00 Set
operation and consisting of following:
complete in all respect as required
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body and
bronze impeller with stainless steel shaft,
mechanical seal at specified flow of 180 lpm
at 70 m. head conforming to IS: 1520.with
suitable size of footvalve confirming to IS
4038, Pressure rating PN2 , preventing entry
of foreign body to pump through suction pipe,
perfectly flat seating surfaces for good
b) Suitable HP Squirrel cage induction motor
TEFC type suitable for operation on 415 volts,
3 phase 50 Hz. AC with IP 55 Class of
protection for enclosure, horizontal foot
mounted type with Class F' insulation,
conforming to IS :
c) M.S. fabricated Common base plate,
flexible rubber coupling, coupling guard,
foundtion bolts etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.1.3 ENGINE DRIVEN PUMP
Supplying, Installation, Testing and
Commissioning of diesel engine driven main
1.00 fire pump suitable for automatic operation and 506181.00 Set
consisting of following: complete in all respect
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body and
bronze impeller with stainless steel shaft,
mechanical seal to ensure a minimum
pressure of 3.5 kg/sq. cm at highest and
farthest outlet at specified flow of 2280 lpm at
65 m. head conforming to IS
b) Suitable HP, 1500 /1800 RPM water cooled
with radiator, diesel engine conforming to
relevant BS & IS standard complete with auto
starting mechanism, 12/24 volts electric
starting equipment, 180 AH lead acid battery
with battery stand, exhaust pipe extended
upto 6 m. outside pump house duly insulated
with 50 mm thick glass wool with 1.0 mm.
thick aluminium sheet cladding, residential
silencer, instruments and protection as per
specification, stop solenoid for auto stop in
the event of fault with audio indications,
painted with post office red colour etc. as
c) One 200 Ltr capacity day oil storage tank
fabricated from 3 mm thick M.S. plates. Tank
shall be provided with inlet, outlet, overflow,
air vent, drain connections, filling connection
& level indicator. Tank shall be mounted on a
suitable steel structure (Painted with 2 coats
of red oxide paint). Tank shall be provided
with two or more coats of synthetic enamel
paint outside over two coats of red oxide
d) M.S. Fabricated Common base plate,
coupling, coupling guard, foundation bolts etc.
e) Suitable cement concrete foundation duly
plastered with anti vibration pads.
Fabrication, Supplying, Installation, Testing &
Commissioning of electrical control panel of
cubical construction, floor mounted type,
fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable
doors, dust and vermin proof, powder coated
of approved shade after 7 tank treatement
process, cable alley, inter-connection, having
1.00 switchgears and accessories mounting and 311460.00 No
internal wiring, earth terminals, numbering
etc. complete in all respect, suitable for main
fire pump, pressurisation pump complete as
per CPWD specification with following in
coming and Outgoings, suitable for operation
on 415V, 3 phase, 50Hz Ac Supply with
enclosure protection class IP 42 as required
:suitable for operation on 415 V, 3 phase,
HZ, AC supply with enclosure protection class
IP 42 as required.
A. Incoming Feeder:-
(i) 1 No of 250 A,35KA, 415V,FP MCCB with
Thermalmagnetic Based Releases having
O/C, S/C ,E/F protection, Digital ELR
96x96mm with CBCT, FP Spreader Terminals
1 set= 8 Pcs, Extended Rotory Handle for
MCCB, 240V AC Shunt Trip coil for MCCB.
(ii) LED type indicating Lamp with suitable
rating 2 Amp SP MCB:- 1 Set (each set
comprise of R,Y,B)
(iii) Digital type 3 phase Multi function Meter
with suitable rating of MCB & 3 Nos. of single
core epoxy resin cast type CTs of 250/5
Amps, 10 VA, CL 1.0 ratings -1 Set.
415 V, 200 Amps, FP Aluminium Busbars with
Heat shrinkable color code insulation sleeves.
OUTGOINGS:-( All outgoing feeders for
pumps should have digital Ammeter with
selector switches and LED type ON,OFF,Trip
indicating Lamps )
1 sets - 160 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for 85 HP pump with overload
protection, current sensing type single phase
preventor complete with all acceessories and
internal wiring required for automatic
operation,selector switch for local/remote,
auto/manual/OFF operation.
1 sets - 160 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for 85 HP pump with overload
protection, current sensing type single phase
preventor complete with all acceessories and
internal wiring required for automatic
operation,selector switch for local/remote,
auto/manual/OFF operation.
1 no.63A,16KA MCCB Ics=100%,Extended
Rotry handle with TM release having O/C &
S/C protection with 12.5 HP fully automatic
star/ delta starter , current sensing type,
Single Phase Preventer, ON/OFF Push
Button & LED type Indicating lamps complete
with all accessories and internal wiring
required for automatic operation, selector
switch, for local/remote, auto/manual
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch & 3 attempt
starting device, timers and relays as required,
push buttons, start/stop in manual mode.
ii) LED type Indication lamp for High/Low
Lub. Oil pressure, High Water Temp and
Engine ON indication.
iii) Battery charger suitable for 12 V/24 V DC
with boost and trickle selector switch, 0-30 V
DC volt meter, 0-20 Amp DC Ammeter.
iv) All standard relays, accessories for
automatic operation of diesel engine, wiring
with 1.5 sq mm PVC insulated copper wire
between various sensors and system
controller / starter, suitable size cable for
battery charging etc. as required.
System Controller
Designing, Supply, Installation, Testing and
Commissioning of system controller to control
operation of Main Electric Fire Pump, Diesel
Pump, Pressurisation Pump, in sequence as
per specification consisting of relays, timers,
sensors, annunciation window for fault
indication, control wiring complete as
3 NOS. 25A DP MCB " C " Curve
Providing and fixing in position the
1.3 3.00 industrial type pressure gauges with gun 967.73 Set
metal / brass valves complete as required
1.4 3.00 Providing, fixing, testing and commissioning 1329.87 Set
of Pressure Switch with Needle Valve.
Supplying, Installation, Testing and
commissioning of Air vessel fabricated from
10mm MS plate with dished ends,dia of
mm and height 1500 mm with suitable
1.5 1.00 supporting legs, outside painted with one coat 48500.00 No
of primer and two coats of synthetic enamel
paint of approved shade, complete with one
25mm dia connection from pump delivery,
one 25 mm drain with valve.Complete as per
technical specification & drawing details.
Providing, laying, testing & commissioning of
'C' class heavy duty MS Pipe conforming to IS
1239 i/c fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc., in ground
including excavation and providing cement
concrete blocks as support, anticorrosive
treatment with coaltar/asphalt tape as per IS
10221, refilling the trench etc. of following
sizes complete as required .( For HYDRANT )
Providing, laying, testing & commissioning of
'C' class heavy duty MS pipe conforming to IS
3589/IS 1239 including Welding, fittings like
elbows, tees, flanges,tapers, nuts bolts,
1.7 gaskets etc. and fixing the pipe on the
wall/ceiling with suitable clamp/support frame
and painting with two or more coats of
synthetic enamel paint of required shade
complete as required :
1.7.9 5.00 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
Supplying and fixing Single headed internal /
External hydrant valve with 1 No. 63 mm dia
instantaneous FM Gunmetal/Stainless Steel
1.8 coupling and cast iron wheel,ISI marked,
conforming to IS 5290 (type A) with blank
Gunmetal/Stainless Steel cap and chain as
14.00 Single headed Stainless steel 5549.04 No
Providing, fixing, testing and commissioning
of Wall mounting swing type first aid Fire
1.9 13.00 Hose Reel with drum, hanging bracket, 30 M 10499.50 No
x 25 mm dia high pressure hose reel tubing
as per IS:884 with shut nozzle and ball valve
and all required accessories.
Supply, Installation, Testing and
Commissioning of Weather proof Standard
Fire Hose Cabinet wall mounting type
(750 mm x 600 mm x 250 mm deep)
having Double door opening with
necessary locking arrangement by allan key
suitable for housing 2 no.x15 mtrs. hose
pipe, 1no. Branch pipe & nozzle
spanner.Duly synthetic enamel painted.
Providing ISI marked RRL (IS : 636, type‐A)
fire hose pipe 15 meter long and 63 mm dia
1.11 26.00 with ISI marked (IS : 903) Stainless steel male 4020.55 No
and female coupling bound and rivetted to
hose pipes with copper rivets and copper wire
complete as required.
Providing Stainless steel ISI marked 63 mm.
dia. male Instantaneous pattern short branch
1.12 14.00 pipes with 20 mm dia. Nozzle as per IS : 903, 1502.28 No
suitable for 10 Kg/sqcm operating pressure
and suitable for interconnections to hose pipe
coupling as required.
Supplying and fixing of fire brigade connection
of cast iron body with gun metal male
1.13 instantaneous inlet couplings complete with
cap and chain as reqd. for suitable dia MS
pipe connection conforming to IS
1.13.1 1.00 2 way - 100 mm dia M.S. Pipe 6094.09 No
1.13.2 1.00 4 way - 150 mm dia M.S. Pipe 12634.09 No
Providing, fixing, testing and commissioning
1.14 2.00 of 25 mm dia Air Release Valve and Ball 1949.25 No
Valve assembly for Air release system.
Providing, fixing, testing and commissioning
1.15 1.00 Pressure Relieaf Valve 25mm dia with Ball 4940.68 No
Supplying and fixing orifice plate made out of
6 mm thick stainless steel (Grade 304) with
1.16 14.00 orifice of required size to be fitted between 1932.76 No
flange & landing valve of external and internal
hydrants to reduce pressure at the outlet to
the level of 3.5 kg/cm2 complete as required.
Supplying, fixing, testing and commissioning
of butterfly valve of PN 1.6 rating with
bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as
Providing, installation, testing and
commissioning of non-return valve of
1.18 following sizes confirming to IS:5312
complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
Providing, installation, testing and
commissioning of stainless steel Y-strainer
1.19 fabricated out of 1.6 mm thick stainless steel,
Grade 304, sheet with 3 mm dia holes with
stainless steel flange.
Supply, Installation, Testing and
1.2 12.00 Commissioning of Brass. Ball Valves with all 737.27 No
fittings required. 25mm size
Supplying and erecting Flexible PVC
1.21 insulated multistrand multicore 1.1 kv grade
ISI marked copper wires of following size to
be erected as directed.
120.00 f) 1.50 Sq.mm 4 core round PVC sheathed 67.00 Mtr
SITC of fire pump start stop push buttons in
SITC of 2 Zone standalone Fire Alarm
control Panel, 16X2 Character LCD
Display, provision for zone wise contact and
1.23 1.00 sounder. Panel does not have provision to 9300.00 No
connect Repeater Panel. Make: Ravel
Approval: CE Mark. (Including Five year free
maintenance with guarantee)
Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected
1.24 with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as
Supply, Installation, Testing and
Commissioning of Single action Manual Pull
Station.Shock and Vibration Resistant, pull
Down Lever Remains Down Until Reset. Shall
1.25 4.00 be Polarity Insensitive (with all mounting 1201.75 No
accessories , complete with Junction Box for
mooting on Surface, Cable lugs at Ends,
cable compression glands, cable tags and
Supply, Installation, Testing and
Commissioning of Conventional Sounder cum
strobe having tone settings with range of
95dbA and field selectable 15/30/75/110
1.26 4.00 candelas.(with all mounting accessories , 1201.75 No
complete with Junction Box for mooting on
surface, cable lugs at ends, cable
compression glands, cable tags and
CABLES AND TERMINATIONS
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
at road crossing or floor of following size of
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
at road crossing or floor of following size of
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe
at road crossing or floor of following size of
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
1.3 insulated armoured cable complete with out
going tails, insulating tape etc for following
size of cables.
Solder less crimping type Copper lugs
conforming to IS suitable for cable of following
1.31 size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made from
sheet steel. The cable tray should be single or
double bended as per required and as per IS
1.32 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with max
17.5% perforation with coupler plate / Fish
plate and GI hardware like nut - bolt and
washers etc. erection with necessary support(
included) as per Specification and as per
instruction of engineer in charge..
Supply, installation,testing and commissioning
of Chemical Earthing with UL Certified
17.2mm Dia. X 3000mm Long 254 Micron-
Copper bonded M.S. Rod manufactured as
1.33 1.00 per IEC 62561-2 with 25Kg Bentonite powder 12230.00 E.a.
plus " U " bolt rod clamp complete with
Lockable high performence chamber suitable
& tested for 5000T capacity with SS
Hardware.or equivalent
Supplying, Installation, Testing and
commissioning Sewage water submersible
pumping sets of CI casing & impeller, SS
shaft, including with inbuilt water level
sensors for operating the pumps automatically
and all accessories suitable for operation on
220 V-240 V, single phase, 50 Hz. AC supply
> 10 mm solid handling capacity,Minimum
Capacity - 50 LPM,Minimum Head >
SITC of 5 HP sewage pump for the basement
designed for liquids which are non-aggressive
and non-explosive, sewage / effluent water
with solids or fibers, pump shall have non
clog, semi open or closed type impeller with
material of construction of cast Iron FG260,
CF8 AND CF8M, stainless steel shaft,
suitable for pumping liquid up to 50 degree C.
The Pump shall be supplied with double
mechanical shaft seal with material of
1.34.2 2.00 construction of SiC /SiC/Viton/S.S 316 at the 60797.00 No
pump end , close coupled with dry
submersible motor, having class F insulation,
IP 68 protection, epoxy sealed cable entry,
with S1 duty for fully submerged and S3 duty
for partially submerged, suitable for 3 phase,
415volts, 50 Hz power supply, All cast iron
parts shall be CED (cathode electrode
deposition) coated for corrosion resistance
with uniform coating and controlled deposition
thickness of 20-30 microns. The pump has
1500- 200 LPM at 5.8-16.2 Mtr head with
Charges of Preparing Design , Drawings
,Testing of Fire Fighting System with
1.35 1.00 necessary Approval from Local Fire authority.( 76271.19 job
Including Pre-NOC and NOC from Fire
1.36 Providing, fixing, testing and commissioning
of below Auto Glow Signages.
1.36.2 12.00 Fire Equipment: 4" X 12" 514.97 No
1.36.3 4.00 In case of Fire, do not use lift, use staircase: 650.00 No
1.36.5 4.00 Fire Extinguishers 8"x 4" 480.00 No
1.36.7 4.00 Fire Hydrant 4” X 12” 514.97 No
1.36.8 4.00 Fire Hose Reel.4” X 12” 514.97 No
1.36.9 4.00 DCP Extinguisher 8"x 4" 480.00 No
1.36.10 4.00 CO2 Extinguisher 8"X 4" 480.00 No
Providing, fixing, testing & commissioning of
1.37 15mm dia quartzoid bulb type sprinklers of
rating with required accessories :
1.37.1 190.00 Pendent Sprinkler 57°C standard response 362.25 No
(K-80) UL Listed
1.37.2 90.00 Pendent Sprinkler 68°C standard response 471.50 No
(K-80) UL Listed
Supplying, installation, testing &
commissioning of sprinkler flexible pipe (UL
Listed) of stainless steel complete with
NPT on reducer thread with maximum
working pressure of 175 PSI test pressure of
1.38 875 PSI (Burst) with branch line (Inlet) 25mm
NPT male thread to sprinkler head (Outlet)
15mm NPT female thread with reducer,
nipple, 2 side brackets,center bracket,
stockbar of following sizes complete as
required etc of following sizes as required:
Providing fixing, testing and commissioning of
1.39 1.00 Drainning & Testing Assembly 25mm dia with 4939.25 No
Sight Glass , Union joint , Ball Valve & Drain
Supplying, Installation, Testing and
commissioning of Flow Switch on sprinkler
distribution header on each floor with
1.4 necessary Junction Box and shall be
connected to fire alarm panel through cable.
Flow switch shall be "UL" Listed size 150mm
dia/ 100mm dia/ 80mm dia.
Providing, fixing, testing and commissioning
of Sprinkler Alarm valve of cast iron body and
brass/bronze working parts comprising of
water motor alarm, bronze seat clapper, and
1.41 1.00 clapper arm, hydraulically driven mechanical 41510.40 No
gong bell to sound continuous alarm when the
sprinkler system activates,pressure guages,
emergancy releases, strainer, pressure
switch, cock valve complete with drain valve
and bypass, test control box, ball valves,
flanges,gasket etc. 100mm dia.
Supplying, Installation, Testing and
1.42 90.00 commissioning of 2 C X 1.5 Sqmm Copper 122.88 Mtr
Armoured for Flow Switch Cabling from
Announciation panel to Flow Switch.
SUB-TOTAL OF FIRE HYDRANT System
FIRE EXTINGUISHERS & Lightning
2.1 FIRE EXTINGUISHER
FIRE EXTINGUISHER Supplying, Installation,
Testing and commissioning of Dry Chemical
Powder (DCP) 6 Kg Fire Extinguisher Mono
Ammonium Phosphate Powder 40, Stored
2.1.1 6.00 Pressure Type, Pressure Gauge, Controllable 2724.25 No
discharge mechanism Class A, Rating 3A &
Class B rating 21B as per IS 15683 ISI MARK
(ABC Dry Chemical Powder - MAP 40%)fitted
with required accessories including wall
suspension brackets.
Supplying, fixing, testing and commissioning
of CO2 type Fire Extinguisher of capacity
kg filled with Co2 Gas as per IS 15222 with
2.1.2 6.00 controll discharge mechanismfitted with Hose 6526.00 No
& Horn applicable on Class B fire rating 21B
confirms to IS 15683, bearing ISI mark. Co2
Cylinder as per IS
Providing & fixing of ISI marked water CO2
type Portable fire extingusher,9 LTR capacity,
Hydraulic test pressure 35Kgf/ cm2,
Discharge range 2 Mtr,Average discharge
time: Min. 13Sec,Fire Rating 3A,Grade:
Providing & fixing of ISI marked, Squeeze
Grip Cartridge Type water CO2 type Portable
2.1.4 1.00 fire extingusher,9 LTR capacity, Hydraulic 4200.00 No
test pressure 35Kgf/ cm2, Discharge range
Mtr,Average discharge time: Min. 13Sec,Fire
Rating 3A,Grade: IS:15683.
Providing,fixing, testing and commissioning of
10Kg Modular type fire extinguisher having
Nitrogen expellant ,ceiling mounted,Sprinkler
2.1.5 1.00 Nozzle is gas tight the release temperature is 2950.00 No
adjusted with sprinkler imported bulb set at
57 degree C or 68 degree C ,coverage area
SITC of Vertical Air Termination Solid
aluminium with Base- 10 mm dia and
mm long. Air Termination Base tested for
conditioning, Ageing Test & Lightning impulse
2.1.6 5.00 current withstand test: 100 kA of 10/350µs 9323.00 No
waveform in an accredited Third party
laboratory as per 6.3 & 6.4 of IEC 62561-1
2017 protocol with MAST 34mm dia 3000 mm
long- Cold Galvanized
SITC of 8 mm dia solid Aluminium Conductor
for roof top mesh grid and tested as per IEC
62561- 2 conducted in the Govt. accredited
thirty party laboratory to meet the requirement
of IS/IEC 62305 with Required Accessories -
Aluminium Holding clamp at every 1 mtr
distance, Aluminium/SS cross splicer at every
crossing of Alu. conductor, Expansion piece
with connectors at every 20 mtr distance,
Aluminium straight Splicer to connect
conductors. All Accessories should be tested
as per IEC 62561-1 2018 Cl. 6.3 for
conditioning & Ageing Test & 6.4 for
Lightning impulse current withstand test:
kA of 10/350µs waveform(Ageing & Electrical
test ) conducted in a sequence manner &
tested in the Govt. accredited Third party
laboratory to meet the requirements of IS/IEC
SITC of Galvanized Steel Flat 25x6 mm
thickness from earth electrode directly in
ground as required. Zinc coating: 500 g/m
2.1.8 125.00 square (Approx:70 micron coating) tested and 153.00 Mtr
used exclusively for lightning protection
earthing system and ring equipotential
SITC of 14.2 mm dia 3 mtr long Earth
electrode of High tensile steel electrode with
250 micron copper bonding & 1 bag of
Carbon fill Based environment friendly backfill
tested as per IEC 62561-7 in NABL
2.1.9 5.00 accredited Laboratory and suitable stainless 5933.00 No
Steel double sided clamp. Eco Friendly rust
proof heavy duty weather proof Polyethylene
Earth Pit Chamber with following dimensions
:254 mm dia (top), 330 mm dia (bottom) &
260 mm (height).
SUB TOTAL of FIRE EXTINGUISERS
Annual Comprehensive Type Maintenance
3 Contract of for Above Fire Fighting System
For 1-Year DLP + ONE Year
Every six months Testing certificates with
Photographs should be sent to competent
authority by concern contractor.
Annual comprehensive Type Maintenance
3.1 1.00 Charges only During 1st Year DLP / Defect 0.00 Year
Liability period.
Annual comprehensive Type Maintenance
3.2 1.00 Charges for 1st Year after Guarentee / Defect 114142.63 Year
Liability period.
SUB TOTAL of Annual Comprehensive
Maintenance of Fire Fighting Sytem
Window Curtains
Providing & Fixing in Position Vertical Roller
Blinds with Minimum 3 % and Maximum 5 %
Light Transperace Screen Fabric Incuding
Providing & Fixing of Powder coated G-
Channel at the Topof Window with necessary
Screw , Cleats etc. and PVC Roller ( Weight
1 300.00 Pipe) and PVC Chain For Up and Down 1372.03 Sq.mt.
Movement of Blinds etc. of Approved Make
and as per Drawings / Instruction of Engg. in
Charge For All Colors and Shades. Rates
Includes all Lead and Lift For All Floor Level,
All Height , All Material , Accessories, Fixing
Scaffolding , Labor etc. Complete in All
Respects. All Required Accessories &
Material must be From Same Manufacturer.
Providing & Fixing Sun Control Reflective
2 300.00 Type Film / Frosted Film as Selected by 646.37 Sq.mt.
Architect/ Engg. In Charge For Glass Doors /
Windows etc. as Directed.
Signature of contractor Additional City Engineer (SOUTH WEST ZONE)
Seal Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- SOUTH WEST ZONE
Name of Work : Construction Of Women Skill Development Center at F.P.No. 06+109,
T.P.S.No. 26 (Vejalpur) In Sarkhej Ward, South West Zone, Ahmedabad.
FINANCIAL BID (Online Only)
Sr.No. Description Amount
1 Amount For Civil Work Rs.8,46,94,914.40
Amount For Electrical Work with Annual Comprehensive Maintenance for
Years after completion of DLP of 1 Year Rs.
Amount For Fire Fighting System Work with Annual Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
4 Amount For Window Curtains Work Rs.
I/We am/are willing to carry out work at ______% above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : Rs.10,04,62,844.11 Estimated cost put to tender : Rs.10,04,62,844.11
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Signature of contractor Additional City Engineer ( S.W.Z. )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT of WSD.pdf
Vol - 1 WSD.pdf
Vol - 1 B WSD.pdf
Vol - 1 C WSD.pdf
Vol - 1 D WSD.pdf
Vol - 1 E WSD.pdf
Vol - 2 Final Price Bid SWD.pdf
TENDER DRAWING WOMEN SKIL DEVELOPEMENT SARKHEJ.pdf
Photo of SWD.pdf
Download all tender documents and submit your bid