| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.7 L+₹18,147 (1.73%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.8 L+₹35,919 (3.43%)Rejected-Finance 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹11.1 L+₹67,448 (6.44%)Rejected-Finance PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹11.7 L+₹1.2 L (11.4%)Rejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
13 Jan 2024, 6:00 pmClosed
GE (AF) MC CHANDIGARH
GE (AF) MC CHANDIGARH
REPAIR TO WIRING, REWINDING FANS AND GEYSERS AT SECTOR 28, 31 AND 47 UNDER GE (AF) MC CHANDIGARH
2023_MES_633242_1
GE (AF) MC CHD/T-47/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC CHANDIGARH
₹38,800
Yes
4 Mar 2024
18 Dec 2023
15 Jan 2024
18 Dec 2023
13 Jan 2024
5 Jan 2024
Amount
Taking down carefully of point wiring (Light, fan, socket or power complete fittings such as switches, Ceiling roses, pendants, regulator, sockets, Bell push) removing from site of work and making good to the disturbed surfaces of walls/floors etc complete all as specified and directed. NOTE :- Taking down of Light fitting, MCB, DB etc to be measured and paid separately.
Taking down carefully by submain wiring/service connection of any complete all as specified and directed.
Taking down carefully DB box of any sizes & capacity complete all as specified and directed.
POINT WIRING INCLUDING PVC CONDUIT
M&L for Point wiring for One light/fan point controlled by one switch using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete in & including non metallic rigid PVC concealled conduit 1.6mm thick including all fittings and accessories, using new sunken pressed steel terminal boxes with frame and cover plate of suitable size for mounting of modular switches, sockets, fan regulators etc fastened with chromium plated screws and 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly complete all as specified and directed.
All as per Srl item No. 3.01 here in before but One 3-pin socket outlet 5 Amp on independent board.
All as per Srl item No. 3.01 here in before but One 3 pin socket outlet 5 Amp on same board.
All as per Srl item No. 3.01 here in before but One light point controlled by 2, two way switches.
All as per Srl item No. 3.01 here in before but One bell point controlled by one switch.
All as per Srl item No. 3.01 here in before but with 2.5 Sqmm copper conductor cable and 2.5 sqmm PVC insulated standard copper conductor complete FRLS cable as continuous earth wire all as specified for One 3 pin socket outlet 15 Amp on independent board.
POINT WIRING ON EXISTING PVC CONDUIT
M&L for Point wiring for One light/fan point controlled by one switch using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete with universal colour code in existing steel/PVC conduit and using new sunken pressed steel terminal boxes with frame and cover plate of suitable size for mounting of modular switches, sockets, fan regulators etc fastened with chromium plated screws and 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly complete all as specified and directed.
All as per Srl item No. 4.01 here in before but One 3-pin socket outlet 5 Amp on independent board.
All as per Srl item No. 4.01 here in before but One 3 pin socket outlet 5 Amp on same board.
All as per Srl item No. 4.01 here in before but One light point controlled by 2, two way switches.
All as per Srl item No. 4.01 here in before but One bell point controlled by one switch.
All as per Srl item No. 4.01 above, but with 2.5 Sqmm copper conductor cable and 2.5 sqmm PVC insulated standard copper conductor complete FRLS cable as continuous earth wire all as specified for One 3 pin socket outlet 15 Amp on independent board.
M&L for Sub main wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable 6 Sqmm and including PVC conduit (not less than 20mm) with all fittings medium grade ISI marked and PVC insulated FRLS copper conductor cable of size 6 Sq mm as earth wire, connected to common earth dolly and all metal part/main switch including taking down old Unserviceable submain wiring complete all as specified and directed. NOTE :- Two runs of single core PVC insulated standarad copper conductor 6 sqmm and one run of earth wire 6 sqmm and PVC conduit run shall be measured as one unit.
M&L for Sub main wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable 6 Sqmm by drawing into existing concealed cinduit (not less than 20mm), PVC insulated stranded copper conductor FRLS cable 6 Sq mm as continuous earth wire conductor connected to common earth dolly and all metal part/main switch including taking down old Unserviceable submain wiring complete all as specified and directed. NOTE :- Two runs of single core PVC insulated standarad copper conductor 6 sqmm and one run of earth wire 6 sqmm shall be measured as one unit.
S&F modular switch, 1 module single pole one way 6 Amp complete all as specified & directed .
S&F modular switch, 1 module single pole one way 16 Amp complete all as specified & directed.
S&F modular switch, 1 module single pole two way 6 Amp complete all as specified & directed.
S&F modular Bell push , 1 module 6 amp single pole one way complete all as specified & directed.
S&F Socket outlet 3 pin 6 amp multipurpose, modular type, 2module complete all as specified & directed.
S&F Socket outlet 3 pin 6/16 Amp multipurpose, modular type, 2 module 240 volt complete all as specified & directed.
S&F Step type fan regulator for ceiling fan modular type 1module of any sweep , complete all as specified and directed.
S&F Ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified & directed .
S&F in repair Bell ding dong, Type AC 230 volts, 50Hz, Single Phase , complete all as specified & directed.
S&F in repair MCB single pole and neutral 240 volt 40 Amp to 63 Amp all 'C' series complete all as specified & directed .
S&F in repair MCBs SP 240 volt 5 to 32 Amp 'C' series complete all as specified & directed .
Supply and fixing sheet steel enclosure double door for DB SPN 240 volts 8 way with 200 Amps rated bus bar complete all as specified and directed.
Supply and fixing sheet steel enclosure single door for DB SPN 240 voltS 2 way with 200 Amps rated bus bar complete all as specified and directed.
Supply and fixing in replacement of wall mounted fittings with ABS housing and clear polycarbonate cover including retrofit LED bulb 06/09 watt conforming to city-1/city-2 including making connection with flexible copper 3core cable 0.5 Sqmm from connector/ ceiling rose to fitting complete all as specified and directed.
Supply and fixing in replacement 04 feet 20 Watt LED MS White powder coated Batten with decorative end cap complete with retrofit PC Type , complete all as specified and directed .
Supply and fixing in repair 02 feet 10 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser colour temp, 6500K , PF >0.9 complete all as specified and directed .
Supply and fixing in repair LED Bulk head Luminaire made of pressure die cast aluminium hosing with protected diffuser 9/10 watt system wattage, colour temp, 6500K, PF >0.9 complete all as specified and directed.
Supply and fixing in repair Indoor decorative aluminium extruded 5 watt T5 LED surface mirror fixture having power factor>0.9 with diffuser and decorative end caps(6500K) complete all as specified and directed.
Supply and fixing in repair lamp holder insulated body with black plate for batten fittings, complete all as specified and directed.
Supply and fixing in repair LED bulb 07/09 Watt retrofit type complete all as specified and directed.
Supply and fixing in repair LED street light fitting 30W powder coated, pressure die cast aluminium body and polycarbonate cover with individual LED lense having colour temperature, 6500 +/- 500, PF >0.90 having system efficiency 2400 lumen with all accessories such as connection, nut and bolt etc, complete all as specified and directed.
Supply & Fixing in repair U-clamp complete with rubber real complete all as specified and directed.
Supply and fixing in repair 6201/6202/6203 ball bearing for the ceiling fan, Exhaust fan, any sweep any model complete all as specified and directed .
Supply and fixing in repair capacitor 2.5/3.15 mfd for the ceiling fan, exhaust fan, of any make/model/sweep, complete.
Supply and fixing in repair Step type fan regulator for ceiling fan of any sweep complete all as specified and directed.
S&F in repair PVC canopy of ceiling Fan of suitable size 1200/1400mm sweep complete al as specified and directed.
Supply and fixing in repair FR PVC insulated unsheathed flexible wire copper conductor 1100 volt house wire grade confirm to IS 694/1990 0.75 sqmm twin core including making connection complete all as specified and as directed .
M&L for spray painting with synthetic enamelled paint of approved colour (as approved by GE) after preparation/Making good of old surface suitable for painting of ceiling fan of any sweep/Make/Model complete all as specified and directed.
M&L for disconnecting and taking down the complete ceiling fan with down rod from ceiling hook/Fan box any size /any make/any sweep at any location for carrying out over hauling such as cleaning ,oiling, lubricating, greasing etc and refixing the ceiling fan back on the same location & connecting it properly complete all as specified and directed .
S & F in repair down rod for ceiling fan and making holes for fixing the nut bolt for 1200/1400 mm ceiling fan as per original pattern complete all as specified and directed.
Taking down and rewinding the ceiling fan motor of 1200/1400 mm sweep, with super enameled copper wire of appropriate guage and replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, nut,bolt&washer etc and testing after reassembling and refixing at its original location complete all as specified and directed.
Taking down unserviceable motor of exhaust fan and rewinding motor of Exhaust fan 300 mm single phase 230 volt motor with super enameled copper wire of appropriate guage of any make including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, replacement of missing/worn out nut,bolt & washer split pin etc and testing after reassembling the same complete all as specified and directed.
M&L for disconnecting and taking down the complete Exhaust fan any size /make/sweep at any location for carrying out over hauling such as cleaning, oiling, lubricating, greasing etc and refixing the exhaust fan back on the same location & connecting it properly complete all as specified and directed.
Supply and fixing in repair Exhaust fan Louver for 300 mm complete all as specified and directed.
Material & labour, earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009) including taking down old earthing, complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted rate shall be inclusive of above all provisions.
GEYSER
Supply only in replacement of Heating element 2000 Watt triangular / round type, complete all as specified and as directed.
Supply only in replacement of Thermostate for 25/50 Ltrs capacity geyser and making connection complete, complete all as specified and as directed.
Supply only in replacement of indicator lamp any size/ type 230 Volts for geyser complete all as specified and as directed. Make : ISI Marked.
Supply only in replacement of PVC connection 600 mm long with PTMT symet nut on both ends suitable to carry water at 60 temperature, complete all as specified and as directed.
Supply only in replacement of safety valve ISI marked for any capacity geysers complete all as specified and directed.
Supply only in replacement of non-return valve 15 mm dia horizontal / vertical type ISI marked, for any capacity geysers complete all as specified and directed.
Supply only in replacement of sheet metal including single pole and neutal with 02 pin and earth plug and socket complete with 01 single pole 20 Amps 240 volt, MCB complete including necessary fixing arrangement & all incoming and outgoing electric connection all as specified and directed by Engr-in-Charge.
Supply only in replacement of 03 core flexible cable of size 1.5 Sqmm with FR PVC round sheathed multi copper conductor complete all as specified and directed.
Supply only in replacement of MS stove enamelled fastener 100 mm long complete with nut, washer & split pin complete all as specified and directed.
Note:- Amount of credit of Rs. 78,388.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
HARISH SALES CORPORATION
M/s APEX ENTERPRISES
M/S ASHWANI KUMAR & CO.
Jai Maa Electrical Works
AIREN BUILDERS
Supreet Associates
M/s Shiksha Enterprises
Alpha Engineers and Builders
M/s Shakti Electric Works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .