Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 1 BLOCK A ASTHA APRTMENT BHOJUBEER NEAR CIRCUIT HOUSE VARANASI UTTAR PRADESH 221002 UDYAM UP 75 0008931 | VARANASI | UTTAR PRADESH | 221002 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical Rejected due to Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹14,500
Closing Date
15 Apr 2024, 1:00 pmClosed
SE
OFFICE OF EWC BHELUPUR VARANASI
INCREASING CAPACITY OF 33/11 KV SUBSTATION CHAKIA GRAMIN AND ILLIA DIST- CHANDAULI ON SEMI TURNKEY BASIS.
2024_PVVNV_916323_2
45/EWC(V)/2023-24
Open Tender
Electrical Works
Lump-sum
60 days
chandauli
PLEASE REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
Yes
EE ESWD VARANASI
₹14,500
Yes
18 May 2024
4 Apr 2024
16 Apr 2024
4 Apr 2024
15 Apr 2024
4 Apr 2024
SUPPLY FOR INCREASING CAPACITY OF 33/11 KV S/S CHAKIA GRAMIN FROM (1X5 MVA) TO (1X10 MVA), DIST- CHANDAULI
Separate earthing of T/F (2x60fit)
Alluminium lug 300Sqmm
24 Volt battery and battery charger with cabinet:- (1) 12volt lead acid battery 02 No., (2) 24 volt battery charger 01 No (3) Cabinet 01 No
ERECTION OF INCREASING CAPACITY OF 33/11 KV S/S CHAKIA GRAMIN FROM (1X5 MVA) TO (1X10 MVA), DIST- CHANDAULI
33 Kv CT 200/100/1A
ACSR DOG conductor
33 Kv lightening arrestor
Structure for L.A.
M.S angle 65x65x6mm (for cable stand & Neutral earthing)
Separate earthing of T/F (2x60fit)
Alluminium lug 300Sqmm
24 Volt battery and battery charger with cabinet:- (1) 12volt lead acid battery 02 No., (2) 24 volt battery charger 01 No., (3) Cabinet 01 No
laying & dressing of 11 Kv 3x300sqmm XLPE cable after digging & making of cable trench including loop (sand, bricks & stone slab will be provided by contractor)
Making of 11 Kv 3x300sqmm indoor/outdoor jointing kit
Repairing of T/F & VCB Plinth
Dismantling of old & used 33/11kV, 05MVA power T/F by disconnection of radiator, conservator & other accessories after removal of T/F oil
Shifting of old & used 33/11kV, 05MVA power T/F from existing transformer plinth to safe place in switchyard
Erection of new 33/11kV, 10 MVA power T/F including shifting of T/F from outside to inside the switchyard & mounting on T/F plinth in safe position thereafter fixing & commissioning of all accessories like radiator, conservator etc. top up of T/F oil.
Sundry Civil work (Leveling of switchyard to solve water logging and laying of brick in switchyard complete) and (Repair of boundary wall, Gate etc) if required during erection of power transformer)
Cartage of all other material charges
SUPPLY FOR INCREASING CAPACITY OF 33/11 KV S/S ILLIA FROM (1X5 MVA) TO (1X10 MVA), DIST- CHANDAULI
Separate earthing of T/F (2x60fit)
Alluminium lug 300Sqmm
24 Volt battery and battery charger with cabinet:- (1) 12volt lead acid battery 02 No., (2) 24 volt battery charger 01 No., (3) Cabinet 01 No
ERECTION OF INCREASING CAPACITY OF 33/11 KV S/S ILLIA FROM (1X5 MVA) TO (1X10 MVA), DIST- CHANDAULI
ACSR DOG conductor
33 Kv lightening arrestor
Structure for L.A.
M.S angle 65x65x6mm (for cable stand & Neutral earthing)
Separate earthing of T/F (2x60fit)
Alluminium lug 300Sqmm
24 Volt battery and battery charger with cabinet:- (1) 12volt lead acid battery 02 No., (2) 24 volt battery charger 01 No., (3) Cabinet 01 No
laying & dressing of 11 Kv 3x300sqmm XLPE cable after digging & making of cable trench including loop (sand, bricks & stone slab will be provided by contractor)
Making of 11 Kv 3x300sqmm indoor/outdoor jointing kit
Repairing of T/F & VCB Plinth
Dismantling of old & used 33/11kV, 05MVA power T/F by disconnection of radiator, conservator & other accessories after removal of T/F oil
Shifting of old & used 33/11kV, 05MVA power T/F from existing transformer plinth to safe place in switchyard
Erection of new 33/11kV, 10 MVA power T/F including shifting of T/F from outside to inside the switchyard & mounting on T/F plinth in safe position thereafter fixing & commissioning of all accessories like radiator, conservator etc. top up of T/F oil.
Sundry Civil work (Leveling of switchyard to solve water logging and laying of brick in switchyard complete) and (Repair of boundary wall, Gate etc) if required during erection of power transformer)
Cartage of all other material charges
PRATAP ELECTRICAL INDUSTRIES
R A ENGINEERS
M/S Grid Power Systems
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .