Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L1 | Accepted-AOC Acceptanc of Contract | |
| 2 | L2₹22.2 L+₹7,538 (0.34%)Rejected-AOC | L2 | Rejected-AOC Ok | |
| 3 | L3₹23.9 L+₹1.9 L (8.40%)Rejected-AOC | L3 | Rejected-AOC Ok | |
| 4 | L4₹24.1 L+₹2.0 L (8.95%)Rejected-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L4 | Rejected-AOC Ok | |
| 5 | L5₹24.3 L+₹2.2 L (9.82%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L5 | Rejected-AOC Ok |
| Sl No | Description | Qty | Unit | KRISHANA ELECTRIC WORKS L4 | VIJAY ENTERPRISES L8 | M/S Konark Electric Sales Corporation L6 | Pal Engineering Services L2 | JS CONSTRUCTION COMPANY L1 | Friends fire Engineers L5 | Bhanu Prakash L7 | trinity construction L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Periodical servicing/maintenance of industrial Tumble dryer-T5675 of Electrolux- including taking down carefully all deffective parts, for repair/ servicing, comprising strip opening of plant,re-assembling & testing on load , as directed by Engineer-in-Charge complete all as directed. Note:- (i) Fixing of the new part(s)shall be deemed to be included on rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respective items of 'BOQ'. (ii) Repair/replacement of deffective parts shall be done witin 72 Hrs after intimatied by the Engineer-in-Charge. (iii) Once servicing of plant carried out by contractor will be responsible for entire contract preriod for replacing any other deffective part which falls under supply only catagory. (iii) Required T&P for lifting/shifting of plant is contractors own arrangement without any additional payment.(iv) The contractor shall maintain records of all kinds of maintenance to be carried out.
(iv) Inspection report and job card indicating defective parts and other defects is required to be prepared and signed by contractor, JE and Engineer-in-Charge. | 3 | Each | 10,000 ₹30,000 | 10,000 ₹30,000 | 9,500 ₹28,500 Lowest | 20,000 ₹60,000 | 12,500 ₹37,500 | 25,000 ₹75,000 | 10,000 ₹30,000 | 15,000 ₹45,000 |
| 2.00 | M&L for taking down defective electric motor from industrial Tumble dryer-T5675 of Electrolux make- after unscrewing nuts bolts of , 3 phase, 415/440 volts, 50 C/s, AC, of any make , shifting the same to workshop, strip opening after unscrewing nut bolts screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enamelled copper winding wire of appropriate size matching with manufactures design including replacement of all insulating materials such as glass paper ,leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size up to terminal connection box , varnishing, drying up and re-assembling refixing and reinstallation at site complete and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P and transportation shall be contractors responsibility. Repair/ replacement of shall be done within a period as intimated by the Engr-in-Charge falling which necessary recovery shall be made from the contractor.
Inspection report and job card indicating defective parts and other defects is required to be prepared and signed by contractor, JE and Engineer-in-Charge. | 3 | Each Job | 10,000 ₹30,000 | 8,000 ₹24,000 Lowest | 9,500 ₹28,500 | 10,000 ₹30,000 | 12,000 ₹36,000 | 25,000 ₹75,000 | 9,000 ₹27,000 | 15,000 ₹45,000 |
| 3.00 | Supply only in replacement Belt front and back (Set of two) of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 3 | Each Set | 10,000 ₹30,000 Lowest | 15,000 ₹45,000 | 14,500 ₹43,500 | 10,000 ₹30,000 Lowest | 18,500 ₹55,500 | 25,000 ₹75,000 | 12,000 ₹36,000 | 17,000 ₹51,000 |
| 4.00 | Supply only in replacement Power supply control unit of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 2 | Each | 10,000 ₹20,000 | 10,000 ₹20,000 | 8,500 ₹17,000 | 20,000 ₹40,000 | 8,500 ₹17,000 | 20,000 ₹40,000 | 7,000 ₹14,000 Lowest | 10,000 ₹20,000 |
| 5.00 | Supply only in replacement I/o cord/PLC of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 2 | Each | 10,000 ₹20,000 | 10,000 ₹20,000 | 18,000 ₹36,000 | 20,000 ₹40,000 | 15,000 ₹30,000 | 8,000 ₹16,000 Lowest | 9,000 ₹18,000 | 16,000 ₹32,000 |
| 6.00 | Supply only in replacement Contactor 32 Amps for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 2 | Each | 3,500 ₹7,000 | 4,000 ₹8,000 | 3,000 ₹6,000 | 3,500 ₹7,000 | 3,500 ₹7,000 | 2,000 ₹4,000 Lowest | 4,000 ₹8,000 | 3,500 ₹7,000 |
| 7.00 | Supply only in replacement Contactor 40 Amps for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 2 | Each | 3,500 ₹7,000 | 4,000 ₹8,000 | 4,500 ₹9,000 | 4,000 ₹8,000 | 3,800 ₹7,600 | 2,000 ₹4,000 Lowest | 5,000 ₹10,000 | 4,000 ₹8,000 |
| 8.00 | Supply only in replacement Heating element for dryer (Set of six) for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 3 | Each Set | 15,000 ₹45,000 | 35,000 ₹1,05,000 | 28,000 ₹84,000 | 30,000 ₹90,000 | 43,000 ₹1,29,000 | 10,000 ₹30,000 Lowest | 22,000 ₹66,000 | 35,000 ₹1,05,000 |
| 9.00 | Supply only in replacement Supporting roller for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 3 | Each | 15,000 ₹45,000 | 15,000 ₹45,000 | 17,000 ₹51,000 | 18,000 ₹54,000 | 18,500 ₹55,500 | 9,000 ₹27,000 | 8,000 ₹24,000 Lowest | 9,000 ₹27,000 |
| 10.00 | Supply only in replacement Sealing belt for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size | 3 | Each | 10,000 ₹30,000 | 3,500 ₹10,500 Lowest | 3,500 ₹10,500 Lowest | 3,500 ₹10,500 Lowest | 3,500 ₹10,500 Lowest | 9,000 ₹27,000 | 6,000 ₹18,000 | 5,000 ₹15,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun PIN 248007
REPAIR AND MAINTENANCE OF MECHANICAL LAUNDRY PLANT, DG SETS AND SERVO VOLTAGE STABILIZER INCLUDING CONNECTED WORKS UNDER GE IMA DEHRADUN.
2025_MES_716630_1
GE/IMA/T-45 OF 2025-26 9559/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE IMA Dehradun
As per tender documents/NIT
6 documents required · 6 mandatory
₹500
GE IMA Dehradun
₹90,000
Yes
23 Sept 2025
25 Jun 2025
30 Jul 2025
26 Jun 2025
23 Jul 2025
9 Jul 2025
Amount
Periodical servicing/maintenance of industrial Tumble dryer-T5675 of Electrolux- including taking down carefully all deffective parts, for repair/ servicing, comprising strip opening of plant,re-assembling & testing on load , as directed by Engineer-in-Charge complete all as directed. Note:- (i) Fixing of the new part(s)shall be deemed to be included on rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respective items of 'BOQ'. (ii) Repair/replacement of deffective parts shall be done witin 72 Hrs after intimatied by the Engineer-in-Charge. (iii) Once servicing of plant carried out by contractor will be responsible for entire contract preriod for replacing any other deffective part which falls under supply only catagory. (iii) Required T&P for lifting/shifting of plant is contractors own arrangement without any additional payment.(iv) The contractor shall maintain records of all kinds of maintenance to be carried out. (iv) Inspection report and job card indicating defective parts and other defects is required to be prepared and signed by contractor, JE and Engineer-in-Charge.
M&L for taking down defective electric motor from industrial Tumble dryer-T5675 of Electrolux make- after unscrewing nuts bolts of , 3 phase, 415/440 volts, 50 C/s, AC, of any make , shifting the same to workshop, strip opening after unscrewing nut bolts screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enamelled copper winding wire of appropriate size matching with manufactures design including replacement of all insulating materials such as glass paper ,leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size up to terminal connection box , varnishing, drying up and re-assembling refixing and reinstallation at site complete and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P and transportation shall be contractors responsibility. Repair/ replacement of shall be done within a period as intimated by the Engr-in-Charge falling which necessary recovery shall be made from the contractor. Inspection report and job card indicating defective parts and other defects is required to be prepared and signed by contractor, JE and Engineer-in-Charge.
Supply only in replacement Belt front and back (Set of two) of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Power supply control unit of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement I/o cord/PLC of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Contactor 32 Amps for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Contactor 40 Amps for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Heating element for dryer (Set of six) for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Supporting roller for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Sealing belt for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply and fix in replacement CPU Controller Unit for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply and fix in replacement Door switch for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply only in replacement Door gasket for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply and fix in replacement Bearing for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply and fix in replacement Vaccume switch for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
Supply and fix in replacement Transformer for Dryer of industrial Tumble dryer-T5675 of Electrolux- as per existing type and size
S&F screw of drum mechanism as per existing type and size
S&F cable set of contactor as per existing type and size
Annual servicing/maintenance of industrial industrial vaccum finish iron table 1200mmX750 mm complete with steam genarator of Fabcare make. including taking down carefully all deffective parts, for repair/ servicing, comprising strip opening of plant, re-assembling & testing on load, as directed by Engineer-in-Charge complete all as directed. Note:- (i) Fixing of the new part(s)shall be deemed to be included on rates quoted by the contractor for above item and new parts shall be measured and paid separately as under supply only against respective items of 'BOQ'. (ii) Repair/replacement of deffective parts shall be done witin 72 Hrs after intimatied by the Engineer-in-Charge. (iii) Once servicing of plant carried out by contractor will be responsible for entire contract preriod for replacing any other deffective part which falls under supply only catagory. (iii) Required T&P for lifting/shifting of plant is contractors own arrangement without any additional payment.(iv) The contractor shall maintain records of all kinds of maintenance to be carried out.
Supply only teflon pad of iron machine as per existing size per OEM design complete all as specified and as directed.
Supply only in replacement heating element shoe of iron machine single phase 900 watt 230 volt ISI marked as per OEM design complete all as specified and as directed.
S&F heating element 'U' shape for iron table single phase 3.0 KW 230 volt ISI mark as per OEM design complete all as specified and as directed.
S&F heating element of steam vessel single phase 3 KW cap ISI mark as per OEM design complete all as specified and as directed.
S&F Aluminium shoes of iron machine ISI mark as per OEM design complete all as specified and as directed.
S&F steam rubber pipe of 10kg pressure rating, 3 mtr long nylon embeded of iron machine ISI marked as per OEM design complete all as specified and as directed.
S&F pressure gauge of steam tank of 10kg pressure rating ISI marked as per OEM design complete all as specified and as directed.
S&F contactor 4 pole, single phase 25 Amp cap suitable for iron machine steam tank of 10kg pressure rating ISI mark as per OEM design complete all as specified and as directed.
S&F single phase,230volt water level controller switch of steam vessel ISI mark as per OEM design complete all as specified and as directed.
S&F steam solonoid valve 1/2 (150mm) cap 230 volt single phase of steam vessel ISI marked as per OEM design complete all as specified and as directed.
S&F pressure switch 1/2 (150mm) cap 230 volt single phase of steam vessel ISI marked as per OEM design complete all as specified and as directed.
Supply only in replacment single phase micro switch of paddlel ISI marked as per OEM design complete all as specified and as directed.
S&F single phase rocker switch 15 Amp cap ISI mark as per OEM design complete all as specified and as directed.
Supply and fix in replacement Wall mounting industrial socket 63 amp cap 5 pin ,3P+N+E 415 volts,AC splash proof IP 67 protected make C&S cat part No CS 63249 or equivalent in ABB,Legrand complete all as directed.
Supply and fix in replacement Wall mounting industrial plug 63 amp cap, 5 pin ,3P+N+E 415 volts,AC splash proof IP 67 protected.
Supply and fix in replacement of MCCB 4 pole, 63 Amp cap,Thermal Magnetic release conforms to IS/IEC 60947-2 breaking cap 36kA suitable for isolation ,adjustable overload from 0.67 to 1.0In, adjustable short circuit setting from 6.0 to 12 x Ir inbuilt earth fault protection.
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of synthetic enemal paint over one coat of primer complete.
Complete cleaning of Drain valve of Washer extracrtor after unplug from plant by technically skilled person and refix the same every after 15 days complete all as specified and as directed.
Complete cleaning of Filter hatch of tumble dryer after unplug from plant by technically skilled person and refix the same every after 15 days complete all as specified and as directed.
Taking down defective electric driyer motor ( Blower motor) from driyer of any make , shifting the same to workshop, strip opening after unscrewing nut bolts screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enamelled copper winding wire of appropriate size matching with manufactures design including replacement of all insulating materials such as glass paper ,leathered paper, super enameled copper conductor wire connection leads of appropriate size with sleeves of suitable size up to terminal connection box , varnishing, drying up and re-assembling refixing and reinstallation in plant including replacement of bearing and leathe work and complete and testing on load all as specified and directed by Engineer-in-Charge.
M&L for maintenance/servicing of DG sets of capacity 625 KVA twice in a year to carry out the following all as directed:- (i) Check and clean engine,alternator battery,instrument panel,AMF panel,Timer,Contactors,Meters and others etc. (ii) Tightening of all nuts& bolts of DG set and its accessories. (iii) Check for any diesel lekage from any point and rectify if observed. (iv) Check and adjust fan belt tension ,replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/silencer,Repair if required. (vi) Check electrical connections of engine .The wiringshall be maintened properly and engine starting system from engine instrument panel is to be kept in order. (vii) Check and tighten the AVM pads nuts and bolts,change AVM pads if found damaged. (viii) Check exhaust pipe,flange and lagging Repair if found damaged. (ix) Check output of alternator ,if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling,Greasing and checking for proper & smooth functioning(xii) Change of Air filter element with O ring (xiii) Change of filter insert with O ring (xiv) Change of Lub oil filter (xv) Change of Primary filter element (xvi) Change of secondary filter element (xvii) Change of greaves lub oil CI4- 10ltrs pack (xviii) Change of Radiator pre-mix greaves kOOL 10ltrs, complete all as specified and directed by Engr -in-charge. Note : (i) Spare parts/Engine oil/check kit/ filters shall be measured and paid for seperately under successive items. (ii) Servicing shall be carried out by authorised dealer of manufacturer. (iii) Inspection report and job card shall be prepared and signed by JE & EIC before servicing.
All as per item No. 40 here in before but 500 KVA
All as per item No. 40 here in before but 320 KVA
All as per item No.40 here in before but 200 KVA
All as per item No. 40 here in before but 160 KVA
All as per item No. 40 here in before but 125 KVA
All as per item No. 40 here in before but 110 KVA
All as per item No. 40 here in before but 62.5/45/30/25 KVA
Supply only for cogged fan belt set of two for DG set of capacity 625/500/320 KVA as per existing type and size
All as per item No. 48 above for 200/160/125/110 KVA
All as per item No. 48 here in before but 62.5/45/30/25 KVA
Supply only water pump for DG set of capacity 625/500/320 KVA as per existing type and size
All as per item No. 51 here in before but 200/160/125/110/ KVA
All as per item No. 51 here in before but 62.5/45/30/25 KVA
Supply only water hose pipe for DG set of capacity 625/500/320 KVA as per existing type and size
All as per item No. 54 here in before but 200/160/125/110 KVA
All as per item No. 54 here in before but 62.5/45/30/25 KVA
Suupply only Oil filter with gasket for DG set of capacity 625 KVA
All as per item No. 57 here in before but 500 KVA
All as per item No. 57 here in before but 320 KVA
All as per item No. 57 here in before but 200 KVA
All as per item No. 57 here in before but 160 KVA
All as per item No. 57 here in before but 125 KVA
All as per item No. 57 here in before but 110 KVA
All as per item No. 57 here in before but 62.5/45/30/25 KVA
Supply only Diesel filter with gasket for DG set of capactiy 625 KVA
All as per item No. 65 here in before but 500 KVA
All as per item No. 65 here in before but 320 KVA
All as per item No. 65 here in before but 200 KVA
All as per item No. 65 here in before but 160 KVA
All as per item No. 65 here in before but 125 KVA
All as per item No. 65 here in before but 110 KVA
All as per item No. 65 here in before but 62.5/45/30/25 KVA
Supply only Element air cleaner inner and outer for DG set 110 to 160 KVA
All as per item No. 73 here in before but 320 to 600 KVA
Supply only Lub oil bypass filter with gasket for 500 to 625 kVA DG set
All as per item No. 75 here in before but for 320 to 600 KVA
M & L for complete checking of AMF panel/DG Set Engine/Alternator finding the fault, and rectified the minor/Major defeccts to make it serviceable condition including replacement of unserviceable spares and testing complete all as specified and as directed by EIC.(Spare parts shall be measure and paid separtly in relevant items)
M & L for drain out of old Engine oil from oil sump of any capacity of installed DG sets, cleaning of oil sump properly, pouring of fresh dehydrated Engine oil as required grade, complete top up of any make of DG sets all as directed
M&L for top up of coolant in DG set at various locations of approved make. PV & TC are to be produced by the contractor.
M& L for fuel hose pipe suitable for 30 to 500 KVA
Supply, installing , testing & commissing of DG Controller make Deep Sea model - 4520 or its equivalent make as per site requirement.
supply in fixed in repair for battery charger PLC base 12 volt in existing DG panel including necessary connection all as specified.
supply and fixed in repair for battery charger PLC base 24 volt in existing DG panel for cap 100 KVA to 500 KVA DG Set including necessary connection all as specified.
All as per item No. 83 above but for cap 45/30/25 KVA DG Set
M&L for taking down turbo set kit and supply and replacement of turbo set kit for DG set 110 kVA to 500 kVA complete all as specified.
M&L for dismantling and Servicing and caliberation of FIP (Fuel injection pump) & nozzles including replacement of minor parts like nuts,bolts,washers etc of DG Set upto 63 KVA capacity
M&L for dismantling and Servicing and caliberation of FIP (Fuel injection pump) & nozzles including replacement of minor parts like nuts,bolts,washers etc of DG Set 110 to 200 KVA capacity
S & F in replacement Relay card 12/24 volt for 63/110/125/200/320/500/625 KVA DG set and testing complete for proper functioning.
S & F in replacement Solonid Switch 12/24 volt for 160/125/200/320/500/625 KVA DG set and testing complete for proper functioning.
Supply & fix Lead acid battery 90 AH 12 Volt (Maintenance free battery with min 2 years warranty) for DG set
Supply & fix Lead acid battery 150 AH 12 Volt (Maintenance free battery with min 2 years warranty) for DG set of make Excide/ Amaron.
Supply & fix Lead acid battery 180 AH 12 Volt (Maintenance free battery with minimum 2 years warranty) for DG set of make Excide/ Amaron.
Supply & Fix of battery lead of 1.5 m lengh with terminal & lugs for DG set battery complete all as directed by Engr in charge.
S&F in replacement of Ignition Switch of DG Sets & complete all as directed.
Periodical servicing/maintenance of industrial washer extractor with microprocessor panel Make of plant 'A' One Engineering Works ,Including taking down carefully all deffective parts, for repair/ servicing, comprising strip opening of plant, re-assembling & testing on load, as directed by Engineer-in-Charge complete all as directed. Note:- (i) Fixing of the new part(s)shall be deemed to be included on rates quoted by the contractor for above item and new parts shall be measured and paid separately as under supply only against respective items of 'BOQ'. (ii) Repair/replacement of deffective parts shall be done witin 72 Hrs after intimatied by the Engineer-in-Charge. (iii) Once servicing of plant carried out by contractor will be responsible for entire contract preriod for replacing any other deffective part which falls under supply only catagory. (iii) Required T&P for lifting/shifting of plant is contractors own arrangement without any additional payment.(iv) The contractor shall maintain records of all kinds of maintenance to be carried out.
M&L for taking down defective electric motor from industrial washer extractor of capacity 35 kg- after unscrewing nuts bolts of , 3 phase, 415/440 volts, 50 C/s, AC, of any make , shifting the same to workshop, strip opening after unscrewing nut bolts screws etc. taking out rotor from stator, cutting and taking out burnt winding carefully from the stator, cleaning of slots, rewinding of stator with super enamelled copper winding wire of appropriate size matching with manufactures design including replacement of all insulating materials such as glass paper ,leathered paper, PVC insulated copper conductor wire connection leads of appropriate size with sleeves of suitable size up to terminal connection box , varnishing, drying up and re-assembling refixing and reinstallation at site complete and testing on load all as specified and directed by Engineer-in-Charge. Note:- Required T&P and transportation shall be contractors responsibility. Repair/ replacement of shall be done within a period as intimated by the Engr-in-Charge falling which necessary recovery shall be made.
Supply and fix in replacement of Water level sensor with pipe of Industrial Washer Extractor Machine as per existing type and size
Supply and fix in replacement water solenoid valve of Industrial Washer Extractor Machine as per existing type and size
Supply and fix in replacement Heating element 6.6 KW for Industrial Washer Extractor Machine as per existing type and size
M&L for taking down defective automatic star delta starter with auto transformer 3 phase, 415 volt, capacity 100 HP suitable for 75 HP submersible motor by disconnecting the electric connections from the main panel and repair/servicing the same complete all as specified and directed. Replacemet of the defective parts will be measured and paid separately under respective items. .
Supply only following parts for repairing/ replacement in the automatic star delta starter 100 HP :-
Supply only moving Contact for starter 100 HP.
Supply only Non moving Contact for starter 100 HP
Supply only start delta timer for 100 HP submersible motor starter.
Supply only Auxilary Switch complete set.
Material and labour for rewinding the auto transformer of automatic star delta starter capacity 100 HP, 3 phase, 415 volt with cupper wire as per existing guage and size complete all as directed.
Disconnecting the defective voltage stabilizer 3 phase oil cooled servo controlled of 100 to 150 KVA capacities from incoming and outgoing cables and opening the stabilizers for checking the defects, draining out transformer oil and carrying to workshop as required for repair and back to site including making connections and testing complete including replacement of gasket set unserviceable nuts & bolts, washer complete all as specified and directed by the Engr in Charge. (i) Inspection report and job card is to be prepared before replaceout of parts. Parts shall be approved make.
Supply only following parts for repair/replacment in the automatic voltage stabalizer cap 100 to 150 KVA :-
Supply in renewal of micro switch complete all as specified and as directed.
Supply in renewal of Auto manual switch complete all as specified and as directed.
Supply in renewal of servo circuit card complete all as specified and as directed.
Supply and fix in renewal of dimmer coil complete all as specified and as directed.
Supply in renewal of push button
Supply and fix potentio meter all as specified and as directed.
Supply in renewal of electronics sensing card (PCB) suitable complete all as specified and as directed.
Supply and fix in renewal of electronic sensor transformer complete all as specified and as directed.
Pal Engineering Services (BID ID -3367969)
trinity construction (BID ID -3360365)
KRISHANA ELECTRIC WORKS (BID ID -3353294)
Friends fire Engineers (BID ID -3368907)
M/S Konark Electric Sales Corporation (BID ID -3360896)
Bhanu Prakash (BID ID -3360639)
VIJAY ENTERPRISES (BID ID -3360077)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .