| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-Finance COMET ELECTRICAL ENGINEERING CO KOTTAKKAL MALAPPURAM | L1 | Accepted-Finance accept | |
| 2 | L2₹3.4 L+₹28,064 (9.07%)Accepted-Finance | L2 | Accepted-Finance accept | |
| 3 | Rejected-Technical | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | ANSARI KUNDIL L1 | SAJITHLAL K L2 | SHAJAHAN K A L3 |
|---|---|---|---|---|---|---|
| 1.00Electrification | ||||||
| 1.00 | 90.15.2.2:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters | 1 | each | 1,35,000 ₹1,35,000 Lowest | 1,75,000 ₹1,75,000 | 1,38,000 ₹1,38,000 |
| 1.00 | 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 6 | each | 18,500 ₹1,11,000 | 16,500 ₹99,000 Lowest | 23,000 ₹1,38,000 |
| 1.00 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 3 | cum | 400 ₹1,200.4 | 350 ₹1,050.35 Lowest | 375 ₹1,125.38 |
| 1.00 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 1.53 | cum | 8,500 ₹12,996.5 Lowest | 9,000 ₹13,761 | 9,062 ₹13,855.8 |
| 1.00 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 3 | sqm | 350 ₹1,050 | 500 ₹1,500 | 341 ₹1,023 Lowest |
| 1.01 | OD85999/2026-2027:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position
and binding all complete | 15.06 | kg | 77 ₹1,159.62 | 100 ₹1,506 | 70 ₹1,054.2 Lowest |
| 1.01 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | 4 | metre | 120 ₹480 | 140 ₹560 | 100 ₹400 Lowest |
| 1.01 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 39.14 | metre | 85 ₹3,326.9 | 120 ₹4,696.8 | 76 ₹2,974.64 Lowest |
| 1.01 | 90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm | 5 | metre | 145 ₹725 | 200 ₹1,000 | 130 ₹650 Lowest |
Tender Value
₹3.7 L
EMD Value
₹9,336
Closing Date
24 Sept 2026, 5:00 pmClosed
BLOCK DEVELOPMENT OFFIER AREEKODE
BLOCK PANCHAYATH OFFICE AREEKODE
MPLADS-Installation of Highmast light at Keezhuparamba Town WC 11446 in Keezhuparamb GP
2026_CRD_870652_1
B/Sep/1/2026
Open Tender
Electrical Works
Item Rate
150 days
KEEZHUPARAMB GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹825
Yes
₹9,336
Yes
1 Oct 2026
17 Sept 2026
26 Sept 2026
17 Sept 2026
24 Sept 2026
17 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | 90.15.2.2:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters | 1 | each | - | - |
| 1.002 | 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 6 | each | - | - |
| 1.003 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 3 | cum | - | - |
| 1.004 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 1.53 | cum | - | - |
| 1.005 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels | 3 | sqm | - | - |
| 1.006 | OD85999/2026-2027:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position
and binding all complete | 15.06 | kg | - | - |
| 1.007 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | 4 | metre | - | - |
| 1.008 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 39.14 | metre | - | - |
| 1.009 | 90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm | 5 | metre | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1475314.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Tendernotice_2.pdf
PDF • 0.02 MB
Tendernotice_3.pdf
PDF • 0.03 MB
AFD.pdf
Tender Documents • 0.11 MB
SBD.pdf
Tender Documents • 1.63 MB
BOQ_1475314.xls
BOQ • 0.32 MB
FOT.pdf
Tender Documents • 0.12 MB
PA.pdf
Tender Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .