Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.0 L+₹83,537.20 (2.08%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹43.8 L+₹3.7 L (9.14%)Rejected-Finance JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹44.7 L+₹4.6 L (11.4%)Rejected-Finance 3 358 PALLICKAL KRISHNALAYAM PAKALKURI PO VARKALA THIRUVANANTHAPURAM KERALA 695604 | VARKALA | THIRUVANANTHAPURAM | KERALA | 695604 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹57.7 L+₹17.5 L (43.6%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | Benchmark Engineers and Contractors L1 | Jack Electrolinks Private Limited L5 | T.P.SUNIL KUMAR L3 | M/s VJ ENTERPRISES L4 | SREEKRUPA ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, testing & commissioning of silent/containerised diesel engine driven generating set with control Panel complete to give an output of 15 KVA, at 415 volts, 50 Hz, 3 phase, 4 wire supply with power factor 0.8 (Lagging), 1500 rpm, engine as per IS:10001/10002 and alternator as per IS:13364 complete with relay panel and switch gears for automatic starting on main failure, mounted on common base plate, anti vibration rubber mounting pad complete in all respect with and including accessories and components as specified below including supply & fixing aesthetically designed weather and sound proof acqoustic enclosure with insulation conforming to UL94‐HF1 class for flammability for 15 KVA Generator sets ECO friendly and as per Ministery of Environment, latest CPCB norms complete all as specified and directed by Engr-in-Charge
Note:- Contractor should responsible for deposited the old BER DG set from old location to MT Yard.
Make: Kirloskar (Engine Model No : 3R550TC4G1) & coupled with company specified alternator (Meeting Emission & Noise compliant as per latest CPCB) or Equivalent in Cummins/Greaves-Cotton/Caterpillar | 2 | Each | 4,95,000 ₹9,90,000 Lowest | 9,25,000 ₹18,50,000 | 5,49,000 ₹10,98,000 | 5,10,000 ₹10,20,000 | 5,80,000 ₹11,60,000 |
| 2.00 | M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using galvanised iron strip 32x6mm as earthing lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 50 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt). | 18 | Each Set | 7,600 ₹1,36,800 | 9,500 ₹1,71,000 | 6,900 ₹1,24,200 Lowest | 7,500 ₹1,35,000 | 7,000 ₹1,26,000 |
| 3.00 | Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard/dense soil and in road cutting all as specified and as directed | 387 | Cubic Metre | 440 ₹1,70,280 | 315 ₹1,21,905 | 450 ₹1,74,150 | 205 ₹79,335 Lowest | 400 ₹1,54,800 |
| 4.00 | Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft /loose soil and in road cutting all as specified and as directed | 133.65 | Cubic Metre | 320 ₹42,768 | 350 ₹46,777.5 | 400 ₹53,460 | 260 ₹34,749 Lowest | 350 ₹46,777.5 |
| 5.00 | Excavating in trenches n.exc. 1.5m wide and n.exc 1.5m in depth for laying of LT UG cable, pipe, pole, stay etc and n exc 10sqm on plan and getting out in soft disintegerated rock including taking out and removal of old bricks laid over for protection of cable all as specified and directed. | 50 | Cubic Metre | 340 ₹17,000 | 285 ₹14,250 | 1,200 ₹60,000 | 270 ₹13,500 Lowest | 400 ₹20,000 |
| 6.00 | Excavating in trenches n.exc. 1.5m wide and exc 1.5m and n.exc 3 m depth for foundation of pole, stay etc and n exc 10sqm on plan and getting out in soft/loose soil complete all as specified and directed. | 0.7 | Cubic Metre | 370 ₹259 Lowest | 415 ₹290.5 | 600 ₹420 | 750 ₹525 | 600 ₹420 |
| 7.00 | Returning and filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 341.46 | Cubic Metre | 95 ₹32,438.7 | 150 ₹51,219 | 120 ₹40,975.2 | 105 ₹35,853.3 | 80 ₹27,316.8 Lowest |
| 8.00 | Removing surplus excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | 229.89 | Cubic Metre | 90 ₹20,690.1 | 85 ₹19,540.65 Lowest | 130 ₹29,885.7 | 95 ₹21,839.55 | 90 ₹20,690.1 |
| 9.00 | Supply and spread natural riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/root etc and refilling /spread in trenches as cushioning and ramming down to form a solid bed covering to cable complete all as specified and directed. | 170.24 | Cubic Metre | 130 ₹22,131.2 Lowest | 950 ₹1,61,728 | 650 ₹1,10,656 | 450 ₹76,608 | 400 ₹68,096 |
| 10.00 | Supply and lay in trenches burnt brick sub class 'B' of old size for of UG cable protection complete all as specified and directed. | 14,088 | Each | 13 ₹1,83,144 | 12.5 ₹1,76,100 | 9 ₹1,26,792 Lowest | 12 ₹1,69,056 | 15 ₹2,11,320 |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
26 Nov 2025, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
SPL REPAIRS IN REPLACEMENT OF DG SET AT KANNUR AND CALICUT, LT OH SYS INTO UG CABLE FOR SHIVAJI COY TO JCO MESS AT KANNUR, PROVN OF SECURITY LIGHT IN RA LINE TO OPEN AIR THEATER AND EXHAUST FANS IN GOVT MD ACCN OF DSC RECORDS UNDER GE (A) TVM
2025_MES_738990_1
8310/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Kannur
As per tender documents
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹85,200
Yes
24 Jan 2026
8 Nov 2025
29 Nov 2025
8 Nov 2025
26 Nov 2025
21 Nov 2025
8 Nov 2025 - 14 Nov 2025
Amount
Supply, Installation, testing & commissioning of silent/containerised diesel engine driven generating set with control Panel complete to give an output of 15 KVA, at 415 volts, 50 Hz, 3 phase, 4 wire supply with power factor 0.8 (Lagging), 1500 rpm, engine as per IS:10001/10002 and alternator as per IS:13364 complete with relay panel and switch gears for automatic starting on main failure, mounted on common base plate, anti vibration rubber mounting pad complete in all respect with and including accessories and components as specified below including supply & fixing aesthetically designed weather and sound proof acqoustic enclosure with insulation conforming to UL94‐HF1 class for flammability for 15 KVA Generator sets ECO friendly and as per Ministery of Environment, latest CPCB norms complete all as specified and directed by Engr-in-Charge Note:- Contractor should responsible for deposited the old BER DG set from old location to MT Yard. Make: Kirloskar (Engine Model No : 3R550TC4G1) & coupled with company specified alternator (Meeting Emission & Noise compliant as per latest CPCB) or Equivalent in Cummins/Greaves-Cotton/Caterpillar
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using galvanised iron strip 32x6mm as earthing lead moulded and retreived to earth plate at one end and connected to main switch / control board at another end with and including 50 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provison of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessarry excavation and earth work including laying the pipe concealed in floor / wall allas per plate NO-3 of SSR Part-I complete all as specified and directed and testing on completiopn (Note:- If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt).
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard/dense soil and in road cutting all as specified and as directed
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft /loose soil and in road cutting all as specified and as directed
Excavating in trenches n.exc. 1.5m wide and n.exc 1.5m in depth for laying of LT UG cable, pipe, pole, stay etc and n exc 10sqm on plan and getting out in soft disintegerated rock including taking out and removal of old bricks laid over for protection of cable all as specified and directed.
Excavating in trenches n.exc. 1.5m wide and exc 1.5m and n.exc 3 m depth for foundation of pole, stay etc and n exc 10sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning and filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spread natural riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/root etc and refilling /spread in trenches as cushioning and ramming down to form a solid bed covering to cable complete all as specified and directed.
Supply and lay in trenches burnt brick sub class 'B' of old size for of UG cable protection complete all as specified and directed.
Material and labour for laying XLPE insulated LT underground cable of size 3.5 core 95 sqmm, armoured heavy duty electric cable with aluminium conductor multi-stranded 1100 volts grade, laid in trench, fixed on wall/pole drawn through pipe etc including of provision of lugs & testing complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 3.5 core 70 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 3.5 core 50 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 3.5 core 35 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 3.5 core 120 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 4 core 25 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 2 core 10 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 4 core 10 sqmm complete all as specified and directed.
All as per item Ser No. 11 here in before, but cable of cross-sectional area 4 core 16 sqmm complete all as specified and directed.
M&L for cement concrete 1:4:8, type D-2 (40mm graded aggregate) for filling foundation & mass concrete/ foundation of poles, stay etc. including formwork (as/if required) complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as for filling foundation & mass concrete/ foundation of poles/coping etc complete all as specified and directed.
Supply , fixing, testing and commissioning new LT feeder pillar panel CPRI approved make from attached list, Outdoor cubical type, dust, weather and vermin proof with front opening made out of 3.15 mm thick CRCA sheet made with 50 x 50 x 5 mm angle iron frame , bottom floor mounted , compartmentalised double door with neoprene gasket and locking arrangement of suitable size ,mounted on PCC foundation with PCC 1:2:4 type B2, duly powder coated on all side /surface internally and externally with earth terminals on two sides with and inclusive of following items complete all as specified and directed.
Cutting the existing hard standing/ bituminous road surfaces for laying cable / GI pipe etc and making good the disturbed surfaces complete all as specified and directed. Note : Excavation required below paving/ road shall be measured and paid separately.
Material and labour for 40mm bore dia light grade GI Pipe, including all fittings and fixing accessories in trench below floor/ road crossing/ fixing on pole, wall etc for protection cable complete all as specified and directed.
Material and labour for 80 mm bore dia light grade GI Pipe, including all fittings and fixing accessories in trench below floor/road crossing/fixing on pole, wall etc for protection cable complete all as specified and directed.
Dismantling old rusted cross arms of MS channel or angle section any size from pole all as directed.
Dismantling old unserviceable insulators of any size, type, capacity complete all as directed.
Dismantling old unserviceable stay assembly including loop insulator complete all as directed.
Dismantling of defective/ perished ACSR conductor over head line from existing LT pole, service feeder or distribution span all as directed.
Supply and fixing LED street light fitting 60 Watts, 230 V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including taking down old unserviceable LED street light complete all as specified and directed.
Supply and fixing brackets for street light fitting made of 40 mm bore GI pipe light grade 1.5m long bend to shape with flat iron clamps 25x 3mm thick, two Nos with nuts, bolts and applying two coats of aluminium painting over one coat of primer, including taking down old unserviceable bracket complete all as specified and as directed.
Supply , fixing, testing and commissioning new LT feeder pillar panel CPRI approved make from attached list, Outdoor cubical type, dust, weather and vermin proof with front opening made out of 3.15 mm thick CRCA sheet made with 50 x 50 x 5 mm angle iron frame , bottom floor mounted , compartmentalised double door with neoprene gasket and locking arrangement of suitable size ,mounted on PCC foundation with PCC 1:2:4 type B2, duly powder coated on all side /surface internally and externally with earth terminals on two sides with and inclusive of following items complete all as specified and directed. (Panel B Near QM Store)
(a) MCCB 4 pole ,25 KA, 415 V with thermal magnetic release 250 Amps-01 No ( for Incoming) (b) MCCB 4 pole ,25 KA, 415 V with thermal magnetic release 100 Amps-2 Nos ( for outgoing) (c) MCCB 4 pole ,25 KA, 415 V with thermal magnetic release 63 Amps-2 Nos ( for outgoing) (d) MCB TPN 63 Amps, 415 V -5 Nos (01 for Standby) (e) MCB SPN 63 Amps, 415 V -3 Nos (01 for Standby) (f) Bus bar set of aluminium 400 Amps for R Y B N - 01 Set (g) Multi function electronic meter 3 phase 415 V suitable to indicate volts, current, power factor frequency and KWH- 01 No. (h) Internal wiring of panel board with suitable size FRLS grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job (j) Indicating lamps for R Y B - 01 Set Note:- Rate quoted shall include Electrical connection of cable at both ends through cable glands/ al lugs
Supply , fixing, testing and commissioning new LT feeder pillar panel CPRI approved make from attached list, Outdoor cubical type, dust, weather and vermin proof with front opening made out of 3.15 mm thick CRCA sheet made with 50 x 50 x 5 mm angle iron frame , bottom floor mounted , compartmentalised double door with neoprene gasket and locking arrangement of suitable size ,mounted on PCC foundation with PCC 1:2:4 type B2, duly powder coated on all side /surface internally and externally with earth terminals on two sides with and inclusive of following items complete all as specified and directed. (Panel D Single JCO Accn & JCO Mess Rear gate)
(a) MCCB 4 pole, 35 KA, 415 V with thermal magnetic release 100 Amps-01 No ( for Incoming) (b) MCB TPN, 63 Amps, C Curve 415 Volts - 4 Nos (01 for Stanby) (c) MCB SPN 40 Amps, C Curve 415 Volts - 4 Nos (01 for Standby) (d) Bus bar set of aluminium 200 Amps for R Y B N - 01 Set (e) Multi function electronic meter 3 phase 415 V suitable to indicate volts, current, power factor frequency, timer and KWH- 01 No. (f) Internal wiring of panel board with suitable size FRLS grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job (g) Indicating lamps for R Y B - 01 Set Note:- Rate quoted shall include Electrical connection of cable at both ends through cable glands/ al lugs
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in pole coping etc including necessary form work to smooth finish surface etc complete all as specified and directed.
Supply and fix Pre-stressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10, including foundation and coping, including taking down old unserviceable pole complete all as specified and directed. Note :- Excavation and PCC will be measured and paid separately.
Supply and fixing LED street light fitting 35 Watts, 230 V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
Supply, laying and testing PVC insulated, PVC sheathed, heavy duty electric cable with stranded copper conductor of size 1.5 Sqmm, 3 Core, 1100 volts grade complete all as specified and diercted
Supply and fix junction box with terminal of size 155x 210x 92mm or nearest higher size made of polycaronate body with IP 66/67 Protection , rust proof, water tight, shock proof, fire retardant, with internally embedded, gasket fitted with heat treated bakelite terminal block and PVC glands for cable entry complete all as specified and directed
Material and labour for 50mm bore dia light grade GI Pipe, including all fittings and fixing accessories in trench below floor/ road crossing/ fixing on pole, wall etc for protection cable complete all as specified and directed.
M&L for point wiring complete for one exhaust fan point controlled by one way switch with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multistranded, copper conductor and drawing in and including non metallic rigid PVC concealed conduit medium grade inclusive of conduit fittings such as Bends, Tees, reducers, etc and galvanized iron sheet steel terminal boxes of size 16 gauge thickness, light switches sockets with 3mm thick bakelite laminated sheet brass screws and cup washers including one continuous run of 1.50 Sqmm nominal area solid conductor PVC insulated unsheathed 1100 Volts grade single core FRLS cable with solid copper conductor green in colour with wire and connecting to earth dolly complete all as specified and directed. Note:- (a) Wiring shall be done by using colour coding. (b) Earth wire shall be of green colour.
S&F Double door MCB SPN sheet metal enclosure for distribution board with powder coated 4 way with 200 amps rated bus bar suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 415 volts and neutral confirms to IS 13032- 1991 complete including and making good the disturbed surfaces of walls, floors filling up of holes, plastering, white washing/ distempering etc matching to the existing all as specified and directed.
S&F MCB SP 6-32 Amps breaking capacity 10 KA, 'B' curve, 240 volts, 50 Hz complete all as specified and directed.
S&F modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as spcified and directed.
Supply, fixing, testing and commissioning BEE 5 star rated exhaust fan, steel body, AC single Phase, 240/230V of size 300mm sweep with, blades, and frame and louvers and all mounting accessories, including making exhaust vent hole on the wall of toilet including suitable length twin twisted flexible copper wire of size 40/0.0076 Sqmm from ceiling rose to fan connetor and all connecing accessories complete suitable for 230V AC, 50 Hz complete all as specified and directed
M&L for boring holes horizontally under road surfaces without damaging the surface (Minimum 1.0 Meter below the road surface with the help of GI tubing n.exc 80mm bore (dia) for passing of UG cable complete all as specified and directed. Note : GI Pipe laid will be measured and paid separately under appropriate items
SREEKRUPA ENTERPRISES (BID ID -3484884)
T.P.SUNIL KUMAR (BID ID -3492404)
M/s VJ ENTERPRISES (BID ID -3482912)
Jack Electrolinks Private Limited (BID ID -3491809)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_827474.xls
BOQ • 0.36 MB
8310Tender.pdf
Tender Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .