Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹14.3 L+₹7,990 (0.56%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹14.6 L+₹41,523 (2.92%)Rejected-Finance | L3 | Rejected-Finance Third lowest | |
| 4 | L4₹16.0 L+₹1.8 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Fourth lowest | |
| 5 | L5₹16.8 L+₹2.6 L (18.0%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest |
Tender Value
Refer Docs
EMD Value
₹47,000
Closing Date
24 Nov 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P) 176061
REPAIR MAINTENANCE OF INTERNAL WIRING MCBs DBs SUB MAIN WIRING AND ELECTRICAL FITTINGS IN OTM ACCN AT PALAMPUR MIL STN
2020_MES_391707_1
GEP- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹47,000
Yes
18 Jan 2021
2 Nov 2020
26 Nov 2020
2 Nov 2020
24 Nov 2020
10 Nov 2020
Amount
Taking down carefully unserviceable Aluminium/ Copper point wiring of any type complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custody for taking credit (credit for above item should be made as per condition seperatly) and making good disturbed surfaces of walls, floor etc complete all as specified and directed.
Taking down unserviceable sub main wiring of any size incl conduit/casing caping/batten (surface m/concealed) and earth wire etc and making good disturbed surfaces to match the existing surface complete all as specified and directed.
Taking down unservecable TPN DB with MCB's of any make/capacity complete all as specified and directed.
Taking down unservecable MCB DB SPN with MCB's of any make/capcity complete all as specified and directed.
Point wiring for one light point controlled by one switch 5 Amp one way using cable 1.5 sqmm for phase and neutral and 1.5 sqmm for earthing and connected to common earth duly using FRLS-H PVC insulated unsheathed multistrand copper conductor cable with proper colour coding drawn through in existing surface / recessed, steel / PVC conduit and making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per the description of Serial item No 5 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch complete all as specified and directed.
All as per the description of Serial item No 5 here-in-before but for 3 pin socket outlet 5 amp independent board complete all as specified and directed.
All as per the description of Serial item No 5 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 2.5 sqmm in contionous earth wire complete all as specified and directed.
Point wiring for one light point controlled by one switch 5 Amp one way using cable 1.5 sqmm for phase and neutral and 1.5 sqmm for earthing and connected to common earth duly using FRLS-H PVC insulated unsheathed multistrand copper conductor cable with proper colour coding drawn through and including PVC casing and caping of approriate size to be terminated in sunk cast iron pressed steel terminal boxes with all fitting such as Tee, connector, pieces, L-junction etc on joints including CI/MS/PVC sunk box of required size for mounting switches socket regulator etc with 3 mm thick ISI marked hylam sheet on surface of wall/ceiling and making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per the description of Serial item No 9 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch complete all as specified and directed.
All as per the description of Serial item No 9 here-in-before but for one bell point controlled by one, one bell push complete all as specified and directed and directed.
All as per the description of Serial item No 9 here-in-before but for 3 pin socket outlet 5 amp independent board complete all as specified and directed.
All as per the description of Serial item No 9 here-in-before but for 3 pin socket outlet 5 amp same board complete all as specified and directed.
All as per the description of Serial item No 9 here-in-before but for One light point controlled by two, two way switches complete all as specified and directed.
All as per the description of Serial item No 9 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 1.5 sqmm in contionous earth wire complete all as specified.
S&F switch piano flush type single pole one way 5 amp ISI marked complete all as specfied and directed.
S&F two way Switch piano flush type single pole one way 5 amp ISI marked complete all as specfied and directed.
S&F socket outlet 5 pin 5 Amp flush type ISI marked complete all as specfied and directed.
S&F switch piano flush type single pole one way 15 amp ISI marked complete all as specfied and directed.
S&F socket outlet 2 in 1, 5 pin, 5 and 15 amp flush type ISI marked complete all as specfied and directed.
S&F bell push piano flush type single pole one way 5 amp 230 volt far electric bell complete all as specfied and directed.
S&F electronic fan regulator flush mounting 230 volt dimmer step type 120 watt having 5 step to regulate / control speed of ceiling fan complete all as specfied and directed.
Point wiring for one light point controlled by one switch 5 Amp one way using cable 1.5 sqmm for phase and neutral and 1.5 sqmm for earthing and connected to common earth duly using FRLS-H PVC insulated unsheathed multistrand copper conductor cable with proper colour coding drawn through and including PVC casing and caping with all fitting of suitable size ISI marked fixed on surface of wall/ceiling and including suitable modular PVC sunken box for fixing of modular switch and socket including cover plate for required module for mounting switches socket etc making connection and making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per the description of Serial item No 23 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified and directed.
All as per the description of Serial item No 23 here-in-before but for one bell point controlled by one, one bell push complete all as specified and directed.
All as per the description of Serial item No 23 here-in-before but for 3 pin socket outlet 5 amp independent board complete all as specified and directed.
All as per the description of Serial item No 23 here-in-before but for 3 pin socket outlet 5 amp same board complete all as specified and directed.
All as per the description of Serial item No 23 here-in-before but for One light point controlled by two, two way switches complete all as specified and directed.
All as per the description of Serial item No 23 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 1.5 sqmm in contionous earth wire complete all as specified and directed.
S&F switch modular single pole one way 6 amp complete all as specfied and directed.
S&F two way Switch modular single pole one way 6 amp complete all as specfied and directed.
S&F socket modular 5 pin 6 Amp complete all as specfied and directed.
S&F switch modular single pole one way 16 amp complete all as specfied and directed.
S&F socket modular 3 pin, 6/16 amp complete all as specfied and directed.
S&F modular Bell push single pole one way 6 amp 230 volt complete all as specfied and directed.
S&F modular fan regulator flush mounting 230 volt dimmer step type 120 watt having 5 step to regulate / control speed of ceiling fan complete all as specfied and directed.
S&F musical door bell AC 230 Volt single phase complete all as specfied and directed.
S&F ceiling rose surface type 65mm x 50mm 3 terminal complete complete all as specfied and directed.
Supply and fixing LED tube light fitting box type suitable for 1x20W 4 FT (2700K/6500K as per requirement) complete with LED tube rod, fixed complete to wall/ceiling and PVC round/square block (02 Nos) of suitable size etc provided complete incl two core wire connection from ceiling rose to connector with flexible pipe of suitable size of all complete all as specified. Make -Crompton Cat Part No DMLN1LT8-16 with tube Cat part No LT8-20-865-2 or equivalent.
Supply and fixing Integral sleek extruded polycarbonate LED channel 10 watt 2 FT (2700K/6500K as per requirement) with white acrylic cover batton integrated complete all as specified. Make: Bajaj Cat Part No. BCLSB 10 WH or equivalent.
Supply and fixing recess / surface mounting LED 2X2 fitting 36 W (2700K/6500K as per requirement) complete all as specified. Make - Bajaj Cat Part No BZRSQL 36W GZ1 CW or equivalent.
Supply and fixing decorative wall light fixture made up of polycarbonate incl LED lamp 10 watt complete all as specified. Make - Havells Cat Part No LHDL03160099 or equivalent.
Supply and fixing LED bulk head luminaire IP-65 with LED bulb 10 W complete all as specified. Make - Bajaj Cat Part No BIBWP 10W LED or equivelant
Supply and fixing lamp holder, PVC/ Polycarbonate type with back plate complete all as specified and directed.
S&F energy efficient 30W LED Street Light fixtures with lens made of pressure die cast aluminium housing and enclosed with toughened glass, control gear and all other associated accessories and colour temperature more than 6500 ºK and conforming to the degree of protection IP - 66 suitable for pole dia Ø 32/40 mm complete all as specified and directed . Make: Bajaj Cat Part No. BCLST 30W LED I or equivalent
S&F street light bracket made out of 32 mm dia GI light grade tubing not less than 1.2 Mtr long bend to shape including pole clamps made out of 30 x 5 iron strip and nut bolts and washers incl painting and primer & synthetic enemal paint complete all as specified and directed.
Taking down old unserviceable light fittings/ Bulkhead fittings of any type and model complete and making good the disturbed surface complete all as specified and directed.
M&L for sub main wiring with colour coding with two single core FRLS-H PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of Single 6 Sqmm in PVC casing and caping of appropreate size including one SIngle core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth and earth dully complete all as specified.
All as per the description of Serial item No 48 here-in-before but 4 sqmm for phase and neutral and one run of 2.5 sqmm for earth wire complete all as specfied.
Supply and fix distribution board iron clad vertical DB double door with IP-43 protection suitable for MCCB as incomer and MCB as outgoing 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete with one MCCB 3 pole 415 V 100 Amp rating with repturing capacity 16 KA of the same make as of distribution board and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface complete all as specified and directed by Engr-in-Charge. Make - Indo Asian Cat Part No 811888 or equivalaent
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface complete all as specified. Make - Indo Asian Cat Part No 811840 or equivalaent
Supply and fix MCB distribution board sheet steel powder coated SPN 12 way double door IP-42 protection with 200 Amp rated busbar 240 Volt complete all as specified and directed.
Supply and fix MCB distribution board sheet steel powder coated SPN 8 way double door IP-42 protection with 200 Amp rated busbar 240 Volt complete all as specified and directed.
Supply and fix MCB distribution board sheet steel powder coated SPN 4 way double door IP-42 protection with 200 Amp rated busbar 240 Volt complete all as specified and directed.
Supply and fix MCB TPN 63 Amps 10 KA 230 volts complete all as specified. Make - Indo Asian Cat Part No 811220 or equivalaent
Supply and fix MCB SPN 40 Amps 10 KA 230 volts complete all as specified and directed.
Supply and fix MCB SP 40 Amps 10 KA 230 volts complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps 10 KA 230 volts complete all as specified and directed.
Supply and fix blanking plate for MCB/DB/Switch board complete all as specified and directed.
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
Taking down old unserviceable ceiling fan any type/size, supply and fixing of ceiling fan AC single phase 240 V of size 1200 mm sweep five star rating with all accessories complete incl provn of flexible wire 3 core of size 23/.0076 from ceiling rose to ceiling fan all as specified. Note:- Old unserviceable ceiling fan to be deposited in MES store yard.
Taking down old unserviceable exhaust fan (Heavy Duty) any type/size, supply and fixing of exhaust fan AC single phase 240 V of size 450 mm sweep (metal body) with louvers shutter and making good disturbed complete with connection from ceiling rose to exhaust fan all as specified. Note:- Old unserviceable exhaust fan to be deposited in MES store yard.
Taking down old unserviceable exhaust fan (PVC body) any type/size, supply and fixing of exhaust fan AC single phase 240 V of size 250/200 mm sweep 1400 RPM with louvers shutter and making good disturbed complete with connection from ceiling rose to exhaust fan all as specified. Note:- Old unserviceable exhaust fan to be deposited in MES store yard.
Taking down old unserviceable swing wall fan any type/size, supply and fixing of swing wall fan AC single phase 240 V of size 300 mm sweep complete with connection from ceiling rose to wall fan complete all as specified. Note:- Old unserviceable wall fan to be deposited in MES store yard.
Supply and fixing temper proof electronic energy meter AC Three Phase four wire Static Energy meter of Accuracy Class 1.0,3X240V,50 Hz, with Backlit LCD Display of Rating 10-60A(Measures & Displays kWh,V, I, kW, six months history of Energy & MD in kW) with Three nos. Push Buttons anti temper proof features as specified with transparent pilfer proof meter box hinged type incl necessory sealing and connection with suitable size of PVC insulated copper cable multistrand with appropriate size of copper lugs at no extra cost incl carefully complete all as specified and directed by Engr-in-Charge.Make - HPL Cat Part No TPPL1510000000OCH1 or equivalaent. Note:- Old unserviceable energy meter to be deposited in MES store yard.
Supply and fixing temper proof electronic energy meter AC Single Phase two wire, Accuracy class 1.0, 240V, 50Hz, with Backlit LCD Display, of rating 5-30A (Measures & Displays kWh, V, I, kW, six months history of Energy & MD in kW) anti temper proof features as specified with transparent pilfer proof meter box hinged type incl necessory sealing and connection with suitable size of PVC insulated copper cable multistrand with appropriate size of copper lugs at no extra cost incl carefully complete all as specified and directed by Engr-in-Charge. Make - HPL Cat Part No SPPL1320010000OC00 or equivalaent. Note - Old unserviceable energy meter to be deposited in MES store yard.
Taking down old unserviceable electric storage water heater any type/size, supply and installation of electric storage water heater (vertical type geyser minimum 3 star rating, 50 ltr capacity 240 V, AC single phase having stainless steel inner tank incl heavy duty pin type fasteners 4'' long and PVC flexible connection pipe as per site requirement incl plug in top 15 amp and making necessary inlet/outlet water connection and making good disturbed surface of walls to match with existing surface complete all as specified. Note:- Old unserviceable electric water heater to be deposited in MES store yard.
Taking down old unserviceable electric storage water heater any type/size, supply and installation of electric storage water heater (vertical type geyser five star rating, 25 ltr capacity 240 V, AC single phase having stainless steel inner tank including heavy duty pin type fasteners 4'' long and PVC flexible connection pipe as per site requirement incl plug in top 15 amp and making necessary inlet/outlet water connection and making good disturbed surface of walls to match with existing surface complete all as specified. Note:- Old unserviceable electric water heater to be deposited in MES store yard.
Supply and fix in repairs modular switch 6 Amp single pole one way complete all as specified and directed.
Supply and fix in repairs modular socket 6 Amp 3 Pin complete all as specified and directed.
Supply and fix in repairs modular switch 16 Amp single pole one way complete all as specified and directed.
Supply and fix in repairs modular socket outlet 6/16 Amp 3 pin complete all as specified and directed.
Supply and fix in repairs modular electronic fan step regulator 230 Volt 120 W complete all as specified and directed.
Supply and fix in repairs batten holder PVC body complete all as specified and directed.
Supply and fix in repairs musical door bell AC 230 Volt single phase complete all as specfied.
Supply and fix in repairs MCB SPN 63 Amps, 10 KA, C curve, 230 volts complete all as specified.
Supply and fix in repairs MCB SPN 6-32 Amps, 10 KA, C curve, 230 volts complete all as specified.
Supply and fix in repairs MCB SP 6 to 32 Amps, 10 KA,C curve, 230 volts complete all as specified.
Supply and fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standed conductor 6 sqmm twin core cable flat or circular complete all as specified and directed.
Taking down of existing unserviceable post top lantern fitting of any type and any description, supply and fix 45 watt LED post top lantern fitting made in die cast aluminium spigot housing with decorative clear opal diffuser and IP65 protection complete incl fixing arrangement on pole and PCC (1:2:4) and necessary connection complete all as specified and directed. Make - Bajaj Cat Part No BGCT W4 LED WW or equivalent
Supply and fix in repairs LED Bulb 10 watt, warm white 2700K, 230 volts complete all as specified and directed.
Supply and fix in repairs T5/T8 tube rod 28 watt 4 feet (2700K/6500K as per requirement) complete all as specified and directed.
Supply and fix in repairs T5/T8 tube rod 36 watt 4 feet (2700K/6500K as per requirement) complete all as specified and directed.
Supply and fix in repairs CFL 36 watt 4 pin type (2700K/6500K as per requirement) complete all as specified and directed.
Supply and fix in repairs electronic chock 28 watt, PF > 0.9 suitable for T5/T8 FTL fitting for easy connections complete all as specified and directed.
Supply and fix in repairs electronic chock 36 watt, PF > 0.9 suitable for T5/T8 FTL fitting for easy connections complete all as specified and directed.
Supply and fix in repairs plug top 15 Amp 230 Volt complete all as specified and directed.
Supply and fix in repairs PVC casing caping of size 20mm complete all as specified and directed.
Supply and fix in repairs rigid non-metallic PVC conduit of size 20mm complete all as specified and directed.
Supply and fix in repairs PVC surface box 3 module with 5 amp switch and socket complete all as specified and directed.
Supply and fix in repairs PVC surface box 3 module with 15 amp switch and socket complete all as specified and directed.
Supply and fix in repairs PVC insulated & unsheathed FRLS-H multistrand copper conductor wire 1100 volt grade of size 1.5 sqmm complete all as specified and directed. NOTE:- Each wire shall be measured and paid.
Supply and fix in repairs PVC insulated & unsheathed FRLS-H multistrand copper conductor wire 1100 volt grade of size 2.5 sqmm complete all as specified and directed. NOTE:- Each wire shall be measured and paid.
Supply and fix in repairs PVC insulated & unsheathed FRLS-H multistrand wire copper conductor wire 1100 volt grade of size 4.0 sqmm complete all as specified and directed. NOTE:- Each wire shall be measured and paid.
Supply and fix in repairs flexible wire two core of size 1.5 sqmm complete all as specified and directed.
R.K. Works
BHARDWAJ BUILDERS
M/s Sheetal Associates
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .