| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC | ₹4.8 Cr | L1 | Accepted-AOC LOA Issued |
| 2 | L2₹5.3 CrRejected-AOC | ₹5.3 Cr | L2 | Rejected-AOC L2 bidder Not considered |
| Sl No | Description | Qty | Unit | ANJALI INFRATECH L2 | SAI SRI CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.00Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-40 (Minimum cement content -as per design mix ) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to cutoff level as per drawing).- concrete also under the scope of contractor, the rate in RM should include concrete cost. Note:.(i) Piles are to be founded with a socketting length into the appropriate strata as per drawing. (ii) Pile chipping and liner cutting as per drawing/ specification included in item | |||||
| 1.01 | 600 mm dia piles | 855 | Rmt | 26,07,750 ₹30.8 L | 23,18,760 ₹27.4 L |
| 1.02 | 750 mm dia piles | 4,731 | Rmt | 1,86,87,450 ₹2.2 Cr | 1,78,40,601 ₹2.1 Cr |
| 1.03 | 800 mm dia pile | 228 | Rmt | 10,14,600 ₹12.0 L | 9,08,124 ₹10.7 L |
| 1.04 | 900 mm dia pile | 427.5 | Rmt | 23,63,647.5 ₹27.9 L | 22,82,422.5 ₹26.9 L |
| 2.00Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge / Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above50 tonne and upto 150 tonne Safe capacity | |||||
| 2.10 | Initial test (Test Load 2.5 times the Safe
capacity) | 1 | Per Test | 2,00,000 ₹2.4 L | 84,746 ₹1.0 L |
| 2.20 | Routine test (Test Load 1.5 times the Safe
capacity) | 1 | Per Test | 1,20,000 ₹1.4 L | 63,560 ₹75,000.80 |
| 3.00Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge / Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above 150 tonne and upto 200 tonne Safe capacity | |||||
| 3.10 | Initial test (Test Load 2.5 times the Safe capacity) | 1 | Per Test | 3,00,000 ₹3.5 L | 1,05,933 ₹1.3 L |
Tender Value
₹5.9 Cr
EMD Value
₹11.7 L
Closing Date
22 Sept 2025, 3:00 pmClosed
DGM
SRO Contracts 3D EC Chambers 92 GN Chetty Road T Nagar Chennai
Piling work for the project Provision of Administrative and Logistic Infrastructure Under Wp07 and Wp5b At Naval Station Rambilli Visakhapatnam Package 04
2025_EPI_247824_1
SRO/CON/ETS/287
Open Tender
Civil Works
120 days
Naval Satation Rambilli Visakapatnam
As per NIT
5 documents required · 5 mandatory
₹2,360
Engineering Projects (India) Ltd.
₹11.7 L
3 Jan 2026
8 Sept 2025
23 Sept 2025
8 Sept 2025
22 Sept 2025
8 Sept 2025
8 Sept 2025 - 22 Sept 2025
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-40 (Minimum cement content -as per design mix ) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to cutoff level as per drawing).- concrete also under the scope of contractor, the rate in RM should include concrete cost. Note:.(i) Piles are to be founded with a socketting length into the appropriate strata as per drawing. (ii) Pile chipping and liner cutting as per drawing/ specification included in item
600 mm dia piles
750 mm dia piles
800 mm dia pile
900 mm dia pile
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge / Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above50 tonne and upto 150 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity)
Routine test (Test Load 1.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge / Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above 150 tonne and upto 200 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity)
Routine test (Test Load 1.5 times the Safe capacity)
Conducting routine vertical load test for 1.5 times safe load carrying capacity by means of High Strain Dynamic Load Test including provision and erection of crane- hammer-drop mechanism, acceleration and displacement velocity transducers to record both force and velocity including excavation, dewatering, preparation of pile head including building up of pile, additional reinforcement if any etc. all complete as per approved method (ASTM D4945-89), submission of test report, specifications and instructions of the Engineer for piles of following diameter :
600 mm dia
750 Dia and Above
Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 (Part IV) for determining safe allowable lateral load on pile :
Upto 50 tonne capacity pile
Above 50 tonne and upto 100 tonne capacity pile
M&L for Reinforcement using TMT CRS bars of Grade Fe–500D of all dia, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in- charge.
MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe-410 S by welding, welding the joints, lengthening wherever required, providing stiffners, lifting hooks including all T&P as required, painting with bitumen paint, shifting the same from position to positions required, driving in true vertical alignment in position to the required level for piles complete, all as directed by Engineer-In-Charge. Note: MS Pipe line shall be casted as mentioned in drawings. However for payment purpose, the depth of height of liner shall be measured upto cutoff level only irrespective of the depth provided for retaining concrete/ bentonite slurry . The unit rate/lumpsum price quoted shall demmed to include for the same.
Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30cm in depth, 1.5m in width as well as 10Sqm on plan) not exceeding 1.50 m in depth and including getting out and disposal of excavated earth lead upto 250m and lift upto 1.5m, as in all kind of soil, complete all as directed by Engineer-in-Charge.
ANJALI INFRATECH (BID ID -904882)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.23 MB
Vol2ETS287.pdf
Tender Documents • 10.73 MB
Vol3ETS287PART2.pdf
Tender Documents • 24.47 MB
VOL4ETS287.pdf
Tender Documents • 1.16 MB
BOQ_283875.xls
BOQ • 0.31 MB
VOL1ETS287.pdf
Tender Documents • 14.16 MB
Vol3ETS287PART1.pdf
Tender Documents • 11.31 MB