Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-Finance | ₹4.7 L | L1 | Accepted-Finance L1 |
| 2 | L2₹6.8 LRejected-Finance | ₹6.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹8.1 LRejected-Finance | ₹8.1 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Kamlesh L1 | Vijay Sharma Contractor L3 | PRAGATI TOWERS CORPORATION L2 |
|---|---|---|---|---|---|---|
| 1.00 | Transportation of suitable truck / tractor mounted where only road available DTH and ODEX / Percussion Calyx / RC Drilling with portable rigs alongwith necessary accessories etc to the site of work and erection of portable rig including leveling etc. complete in all respect as per directions and to the entire satisfaction of Engineer-in-charge including all leads and lifts. | 1 | Each | 5,000 ₹5,000 | 6,500 ₹6,500 | 10,000 ₹10,000 |
| 2.00 | Development of site including levelling at site, through all kinds of roads, approaches, fields etc. in all leads and lifts up to site of work complete in all respects as per the direction of the Engineer-in-charge. | 1 | Each | 1,500 ₹1,500 | 2,500 ₹2,500 | 8,800 ₹8,800 |
| 3.00 | Drilling of bore of 200/220 mm dia as per sepcification laid down in BIS: 2800-1991( Part-I) with up-to-date ammendments, if any with DTH/ODEX method in all kind of soils, boulders, rock, collapsible strata, sturated soils, artesian conditions including the cost of all consumable, stores, water, fuel, lubricants and other accessories etc. complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge. | 60 | Mtr | 5,450 ₹3.3 L | 6,500 ₹3.9 L | 6,000 ₹3.6 L |
| 4.00 | Supply and Lowering of IS marked Electrict resistance Welded M.S. pipe 200 mm dia nominal size housing 6.40 mm thick confirming to BIS: 4270-2001 with up- to-date ammendments if any, of 3 to 6 mtrs. in length welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embeded in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge. | 10 | Mtr | 6,400 ₹64,000 | 6,250 ₹62,500 | 4,950 ₹49,500 |
| 5.00 | Supply and Lowering of IS marked Electrict resistance Welded M.S. sloted pipe 200 mm dia nominal size housing 8.00 mm thickness having outsider dia meter confirming to BIS: 4270-2001 with up- to-date ammendments if any, of 3 to 6 mtrs. in length welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embeded in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge. | 50 | Mtr | 500 ₹25,000 | 5,600 ₹2.8 L | 4,200 ₹2.1 L |
| 6.00 | Labour charges for making slots in M.S. pipe complete job as required at site within all leads and lifts complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge. | 10 | Mtr | 1,800 ₹18,000 | 2,500 ₹25,000 | 500 ₹5,000 |
| 7.00 | Providing and Fixing suitable casing shoe and bit 200 mm dia MSERW pipe as per requirement of ODEX attachement complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge within all leads and lifts. | 1 | Each | 10,500 ₹10,500 | 12,500 ₹12,500 | 3,000 ₹3,000 |
| 8.00 | Collection and preservation of soil samples in polythene bags complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge within all leads and lifts. | 1 | Each | 30 ₹30 | 30 ₹30 | 1,000 ₹1,000 |
| 9.00 | Development of borewell and yield testing with Air Compressor through V-notch and disinfaction etc. complete in all respects as per IS-2800-1979 and as per direction of the direction of Engineer-in-charge within all leads and lifts. . | 1 | Each | 2,500 ₹2,500 | 3,250 ₹3,250 | 15,000 ₹15,000 |
| 10.00 | Development of the tubewell by continuous over-pumping using a VT pump/submersible pump of suitable capacity, not less than double the discharge established by the compressor method/design discharge, until the well stands clear and stable as per Clause 4.2 of BIS 11189-1985 (latest amendments). The work shall be completed in all respects as directed by the Engineer-in-Charge, within all leads and lifts. The drawdown and discharge shall be established by running the VT/submersible pump continuously for 8 hours in the presence of an officer, ensuring that the discharge is not less than double the discharge previously established. The job shall be completed in all respects to the entire satisfaction of the Engineer-in-Charge. | 8 | hour | 2,500 ₹20,000 | 3,000 ₹24,000 | 2,500 ₹20,000 |
Tender Value
Refer Docs
EMD Value
₹13,940
Closing Date
24 Jan 2026, 11:00 amClosed
EXECUTIVE ENGINEER
JAL SHAKTI DIVISION DHARAMSHALA
Installation of Borewell at GP Sidhbari under Dharamshala Constituency, District Kangra Drilling of Tubewell 60 meter deep
2026_HPIPH_125827_1
NO. EE-JSD-EA-I-2026- 15496-595
Open Tender
Civil Works
90 days
dsala
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹13,940
24 Feb 2026
15 Jan 2026
24 Jan 2026
15 Jan 2026
24 Jan 2026
17 Jan 2026
15 Jan 2026 - 17 Jan 2026
Transportation of suitable truck / tractor mounted where only road available DTH and ODEX / Percussion Calyx / RC Drilling with portable rigs alongwith necessary accessories etc to the site of work and erection of portable rig including leveling etc. complete in all respect as per directions and to the entire satisfaction of Engineer-in-charge including all leads and lifts.
Development of site including levelling at site, through all kinds of roads, approaches, fields etc. in all leads and lifts up to site of work complete in all respects as per the direction of the Engineer-in-charge.
Drilling of bore of 200/220 mm dia as per sepcification laid down in BIS: 2800-1991( Part-I) with up-to-date ammendments, if any with DTH/ODEX method in all kind of soils, boulders, rock, collapsible strata, sturated soils, artesian conditions including the cost of all consumable, stores, water, fuel, lubricants and other accessories etc. complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge.
Supply and Lowering of IS marked Electrict resistance Welded M.S. pipe 200 mm dia nominal size housing 6.40 mm thick confirming to BIS: 4270-2001 with up- to-date ammendments if any, of 3 to 6 mtrs. in length welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embeded in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge.
Supply and Lowering of IS marked Electrict resistance Welded M.S. sloted pipe 200 mm dia nominal size housing 8.00 mm thickness having outsider dia meter confirming to BIS: 4270-2001 with up- to-date ammendments if any, of 3 to 6 mtrs. in length welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embeded in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts, complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge.
Labour charges for making slots in M.S. pipe complete job as required at site within all leads and lifts complete in all respects as per the direction and to be entire satisfaction of Engineer-in-Charge.
Providing and Fixing suitable casing shoe and bit 200 mm dia MSERW pipe as per requirement of ODEX attachement complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge within all leads and lifts.
Collection and preservation of soil samples in polythene bags complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge within all leads and lifts.
Development of borewell and yield testing with Air Compressor through V-notch and disinfaction etc. complete in all respects as per IS-2800-1979 and as per direction of the direction of Engineer-in-charge within all leads and lifts. .
Development of the tubewell by continuous over-pumping using a VT pump/submersible pump of suitable capacity, not less than double the discharge established by the compressor method/design discharge, until the well stands clear and stable as per Clause 4.2 of BIS 11189-1985 (latest amendments). The work shall be completed in all respects as directed by the Engineer-in-Charge, within all leads and lifts. The drawdown and discharge shall be established by running the VT/submersible pump continuously for 8 hours in the presence of an officer, ensuring that the discharge is not less than double the discharge previously established. The job shall be completed in all respects to the entire satisfaction of the Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_185416.xls
BOQ • 0.28 MB
form68.pdf
Tender Documents • 0.88 MB
tubewellConditions.pdf
Tender Documents • 0.16 MB
Download all tender documents and submit your bid