Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.6 L+₹1.1 L (7.47%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹18.3 L+₹3.8 L (26.4%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹18.4 L+₹3.9 L (26.9%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹19.2 L+₹4.7 L (32.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-34/2021-22 REPAIRS / MAINTENANCE / IMPROVEMENT TO EXTERNAL ELECTRIC DISTRIBUTION SYSTEM, CABLES, OH LINES AND CONNECTED ITEMS IN TECHNICAL AND DOMESTIC AREAS AT AF STATION AMBALA UNDER GE (AF) AMBALA
2021_MES_471718_1
GE AF/AMB-34/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹60,000
Yes
23 Nov 2021
31 Aug 2021
29 Sept 2021
31 Aug 2021
27 Sept 2021
14 Sept 2021
7 Sept 2021 - 11 Sept 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directeddisposing off complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as in coping to poles, etc. complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in bases to poles, stays, plinths, etc. complete all as specified and as directed
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking up or down ld unserviceable cable as required and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 240sqmm
3.5 core 185sqmm
3.5 core 150sqmm
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
3.5 core 25sqmm
Supplying, laying, jointing and testing XLPE cable, 1100V grade of size 4 core 16sqmm, insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor laid in trenches, passing through ducts/pipes, fixing along poles, etc. including taking down old unserviceable cable and disposing off complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed for the following bores:
100mm bore
50mm bore
40mm bore
M&L for cutting into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes 40/50mm bore, at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
M&L for cutting into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes 100mm bore, at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
M&L for carrying out tests for locating faults in LT cable of any size with the help of fault locator machines, etc. at any location complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 3.5 core, 300/240/185mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 3.5 core, 70/150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 4 core, 35/50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for end termination heat shrink type joint, outdoor type with jointing material and accessories suitable for 4 core, 16/25mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 3.5 core, 185/240/300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV grade cable for straight through heat shrink type joint, indoor/outdoor type with jointing material and accessories suitable for 4 core, 25/35/50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for disconnecting from mains and taking down old / unserviceable LT panels/ feeder pillar boxes / bus bar chambers of any size at any location including breaking down old PCC platform, etc. and disposing off complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 400A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 200A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
M&L for carrying out repairs / maintenance of existing LT panels at any position / location and of any size, by disconnecting connections, etc. cleaning the entire compartments, arranging cables in proper manner, changing burnt lugs by providing new lugs, thimbles, etc., taping with insulated tapes of all naked cable joints/ends, preparation of old treated surfaces and applying one coat of grey synthetic enamel paint including all necessary welding works to reinstate broken / damaged doors, hinges, supports, legs, etc. and cleaning the surrounding upto 2m all around complete all as specified and as directed
S&F bus bar chamber of size 300x300x150mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 100A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments duly fixed on walls alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
S&F 20mm dia ERW steel conduit with proper clamping including connection with PVC unsheathed wire copper conductor 3x1.5sqmm from streetlight box to street light fitting including taking down of old conduit and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 63A, FP, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 100A, FP, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 125A, FP, 16kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 160A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 200A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 250A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 315A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 400A, FP, 36kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
Supplying, fixing, connecting, testing and commissioning MCCB 630A, FP, 50kA, 415V, 50Hz rating with adjustable thermal and magnetic setting including taking out old unserviceable MCCB and disposing off complete all as specified and directed
S&F 10mm thick CI cover with handle, duly hinged in mild steel angle iron frame of size 300x300x300mm made out of MS angle iron of size 40x40x6mm thick duly fixed to existing earthing pits and entirely painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including dismantling and taking down old pit cover and disposing off complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws, taking down and disposing off old unserviceable block complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for brazing / welding works on joints of any type of earth strip complete all as specified and as directed
S&F in repairs identifier legend plate of GI of size 300x200x1.6mm mounted on 25mm dia GI pipe of 0.9m length including cutting to required shape/size, welding, marking, necessary painting and writing the date, type of earth pit and resistance value, etc. having approved font type and size complete all as specified and as directed
M&L for preventive maintenance to functional earthing GI/Cu any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
S&F in repairs copper strip of size 20x3mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs GI strip of size 32x6mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs aluminium strip of size 25x3.15mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F PVC / porcelain insulators fixed on walls, etc. complete all as specified and as directed
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, bolts, nuts, washers and screws type 410 SP-31, 9m long with detachable bracket arms, pole cap including painting with two coats of aluminum paint over shop coat of primer including 3No bent /strips with post office red/yellow colour (300mm wide each) with synthetic enamel paint at a distance 300mm from plinth block and marking pole No. with black synthetic enamel paint including tarring one coat on steel surfaces embedded in concrete including taking down and disposing off old concrete poles complete all as specified and as directed
M&L for taking down existing steel tubular poles from the premises of AF station Ambala from one position and fixing the same in true vertical position, in other position within the premises, by providing new mild steel base plate of size 300x300x6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screws as required complete all as specified and as directed Notes:- (i) Excavation earthwork, foundation concrete will be measured and paid separately under respective items herein (ii) Poles shall be painted with two coats of black bituminous paint throughout up to planting depth and remaining portion of the surfaces shall be painted with two coats of aluminium paint over a coat of red oxide primer. Cost shall be deemed to be included in the quoted rate
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to steel poles 9/11m high/long with two coats of synthetic enamel paint in black & white alternate stipes (in 30cm height 5 blocks of each AF pattern) and top red stripe, upto a height of 1.5m from ground, including painting of pole coping with synthetic enamel paint (black tint) and writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular base, marking of HT/LT, painting of cross arms, brackets with two coats of aluminum paint over a coat of red oxide primer complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting to concrete surfaces of electric poles with one coat of synthetic enamel paint in black & white alternate stripes, upto a height of 1m from ground, including writing (font 1/2"x3") pole numbers with white synthetic enamel paint on circular black synthetic enamel paint base complete all as specified all as directed
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed
M&L in repairs for stringing of aluminum conductor steel reinforced (ACSR), wesel type, stringing properly on insulators and binding with aluminum binding wire, jumpers, etc. complete all as specified and as directed
M&L for re-stringing ACSR conductor, straightening properly on insulators and binding with aluminum tape /binding wire/conductor, jumper, etc. complete all as specified and as directed
M&L for stay assembly and accessories as shown in electrical plate No. 1 of SSR Part-I, using stay rod of 20mm dia, stay plate 6mm thick of size 300x300mm including stay wire 7/3.15mm dia of suitable length including taking down and disposing off old stay assembly complete all as specified and as directed Note: Cost of PCC for fixing shall be deemed to be included in the quoted rate
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, 02Nos. galvanised iron washers and 01No. galvanised iron nut, 100mm height 65mm dia for 1100V grade of size 150mm dia and 150mm long complete all as specified and as directed
S&F in repairs PVC line separator for LT OH line suitable for 3 phase and neutral of capacity 1100V complete all as specified and as directed
M&L for earthing using GI earthing strip 25x4mm with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item No. 67: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
Saurav Enterprises
Esha Engineers
R N Enterprises
sanjeev enterprises
M/S Sonu Traders
The Rahul Vig
R D Bansal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .