Name Of Work: - Development of Mora Lake in Mora Village, Survey No. 25, in Hazira Noti ied Area,
Item Description Qty Labour Cess Unit Total Amount
Item Description Qty Labour Cess Unit Total Amount
Clearing and grubbing road land
including uprooting rank
vegetation grass bushes, shrubs,
sapling and trees girth up to 300 mm
1 removal of stumps of trees cut earlier 0.69 86,555.97
and disposal of unserviceable
materials with all lead and lift. (C)
By Mechanical means in area of light
Providing and supplying selected soil
(approved quality) from approved
borrow area and filling in layers not
2 exceeding 20 cm thickness including 3720.00 301.78 Cum
watering, ramming, compacting,
dressing to required level and section
Demolition including stacking of
serviceable materials and disposal of
unserviceable materials with all lead
and lift. (i) R.C.C. work
Providing and fixing pre-cast Rubber
Dye / steel Dye inter locking concrete
block 60mm thick with grade of
concrete M300 pnumatic compressed
/ vibrated mechanically and as per
4 approved design Confirming to IS 900.00 706.93 Sqmt
15658: 2006 including 35 mm Sand
layer for levelling and filling the joint
with sand in proper line and level as
per guidlines of IRC: SP 63-2018 etc.
Providing and laying permeable eco-
friendly concrete M30 grass paver
blocks of Size 400 x 300 x 80 mm
pproved shape and design over
prepared subgrade including sub-
base, base preparation and lawn
plantation in perforated openings
Slope Protection Work: Supply and
fixing of non-woven needle punched
Polyester 150 GSM geo textile and
150mm thik HDPE Geo cell with
Garden Soil and well decayed cattle
manur with gravel and other required
material and Turfing/Grass/Lawn on
top including all material, labour,
machinery as directed by Engineer In-
Providing panel wall for dry stone
pitching in uncoursed rubble masonry
7 with had stone of approved quality in 1244.00 2,681.70
cement. mortar 1.5 including curing
Providing and fixing 100 cm high
Stainless steel railing made from
anticorrosive 304 grade S S pipe of
mm dia (16Gauge) as hand rail with S
S 304 grade Baluster of 35 mm dia
(16Gauge) as a vertical support fixed
in RCC slab at 1.2m c/c including
three horizontal S S pipes of 25 mm dia
(16Gauge) at eqal distance fixed with
baluster including accessories as per
detailed drawing as directed etc.
Providing and laying rough Kota stone
slab flooring over 20mm (Average)
thick base of cement mortar 1:6 (1-
9 cement: 6-coarse sand) or L.M. 1.1.5 237.00 1,110.75 Sqmt
laid over and jointed with grey cement
slurry including rubbing and polishing
etc. complete. (B) 30 mm thick
Providing and laying polished kota
stone slab 25mm thick in risers of
steps, skirting Dedo and pillars laid on
10mm thick cement mortar 1:3 (1-
10 Cement: 3 coarse sand) and jointed 26.00 1,130.79 Smt
with gray cement slury mixed with
pigment to match the shade of slab
including rubbing and polishing etc.
Brick work using common burnt clay
building bricks having crushing
strength not less than 35 kg. /Sq.Cm. in Cum
foundation and plinth in Cement t
Mortar 1:5. (1- Cement: 5 -fine sand)
(B) Conventional
Providing 20 mm thick double coat
mala cement plaster on interior brick /
concrete work for plastering
comprising of base coat of 12 mm thick
cement plaster in cement mortar (1
12 Cement: 4 coarse sand) in rough 57.00 286.10 Sqm
finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement:
Coarse sand) finished with trovel
including scaffolding curing etc.
Finishing wall with weather proof
exterior emulsion paint on wall
surface (two coats) to give a required
13 shape even shade after thoroughly 53.00 120.26 Sqm
brushing the surface to remove all dirt,
and remains of loose powdered
materials. etc complete.
Providing and laying Vitrified tiles 8 to
10 mm thick, 24''x 24'' in flooring
treads of steps and landing laid on a
bed of 12mm thick cement mortar 1:3
(1-cement: 3-coarse sand) finishing
with flush pointing in white cement.
Providing laying and jointing in true
line and level 40mm dia. U.P.V.C. Pipe
(SCH- 40) for cold water including
fittings make PRINCE / SUPREME /
ASTRAL / FINOLEX or equivalent as
approved by Engineer in Charge. Pipe
15 shall be fixed on the wall with the help 910.00 119.15 Rmt
of clamp at every two metre C/C or
shall be concelled as directed including
necessary fittings etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost
of all materials.
Providing and laying and jointing in
tube line and level 25 mm dia U.P.V.C.
Pipe (SCH -40) for cold water including
fitting make or equivalent as approved
by engineer in charge. Pipe shall be
fixed on the wall with the help of clamp
at every two-meter C/C or shall be
concealed as directed including
necessary fitting etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost
of all materials.
Providing and laying and jointing in
tube line and level 15 mm dia U.P.V.C.
Pipe (SCH -40) for cold water including
fitting make or equivalent as approved
by engineer in charge. Pipe shall be
fixed on the wall with the help of clamp
at every two-meter C/C or shall be
concealed as directed including
necessary fitting etc. including testing
of pipe and joints and fixing the same
with adhesive solvent, including cost
of all materials.
Providing and fixing screw down bib
taps of following size. (B) Brass
chromium plated screws down Bib
Tap. (ii) 20mm dia.
Providing Farm yard Manure of 50.00 Cum
approved quality on site
Labour for spreading and mixing the
manure evenly with top 8 to 10 Cm. of
20 prepared area at the rate of 5 C.mt per 50.00 76.22 Cum
100 Sq.m area. (Rate for one Cu. m. of
Laying out Lawn: After excavating soil
up to 30 cm depth, preparing soil for
planting by supplying and mixing
pepairing soil for planting by
supplying and mixing Farm Yard
21 Manure at the rate of 5 cu. m. per 100 150.00 73.35 Sqmt
Sq. Mt. area , providing and planting
suckers of pure dharo ( doob ) grass
roughly at 10 cm x 10 cm distance and
maintaining till well established etc
complete ( about 45 days ).
Plantation (Pheripherial) -Plantation
of tree in soil incl digging 45 x 45 x
cm size pits Preparing Providing and
mixing organic fertilser Watering
Planting and filing the pits as per
direction including Providing tree
22 plants having minium 1.50 mt height 30.00 714.07 No
and healthy growth of various kinds as
like Pletfrom BOTTLE PALM TREE,
NARIYALI, ROYAL PALM, TRAVELLER
PALM and as suggested .selection will
be approved by Engineer in charge and
Plantation (Pheripherial) -Plantation
of tree in soil incl digging 45 x 45 x
cm size pits Preparing Providing and
mixing organic fertiliser Watering
Planting and filing the pits as per
direction including Providing tree
plants having minium 1.50 mt height
and healthy growth of various kinds as
like neem tree, parijat, gulmohar,
kesudo, kadamb and as suggested
.selection will be approved by
Engineer in charge and architect.
Flowering plants Height of plants: 2ft -
3ft Plants include: Bougainvillea
,Plumeria (Assorted colours) Pit size:
24 2ft x2ft x3ft depth Plant cost +Trilling 1190.00 255.03 No
+Fertilization +plantation. selection
will be approved by Engineer in charge
Planting Trees and shrubs: after
excavating pits of the size 60 cm x
cm x 60 cm refilling’s the same by
25 providing and mixing Farm Yard 490.00 122.66 No
Manure at the rate of 0.06 cu. m. per
pit. Providing and planting well grown
sapling of specified variety and
maintaining till well established
(about 45 days) complete.
Providing & fixing RCC benches as per
drawings and the direction of E.I.C etc.
Supply and installation of 2-seater
seesaw approx Length 2400mm to
3000mm, Fabricated from heavy-duty
powder coated steel with weather-
resistant finish, complete with
ergonomically designed seats, anti-
27 pinch pivot mechanism, ground 2.00 27,270.00 No
stoppers, and safety handles. Suitable
for outdoor park/playground use.
Includes all necessary fixtures,
foundation work, and anchoring as per
manufacturer’s specifications and as
directed by Engineer In-Charge.
Supply and installation of playground
slide, approx. 2.5m height, made of
FRP or powder-coated steel, complete
28 with ladder, safety rails, and anchoring 2.00 41,410.00 No
system. Includes all civil works,
foundation, and finishing as directed
by Engineer In-Charge.
Supply and installation of heavy-duty
playground merrygo-round, diameter
approx. 2.4 to 3.0 meters, fabricated
from powder-coated steel. Unit
includes anti-slip platform, central
rotating axis with sealed bearings,
29 safety handrails, and anchoring 1.00 43,935.00 No
system. Designed for outdoor use with
weather-resistant finish. Includes all
necessary civil works, foundation, and
site preparation as per manufacturer’s
specifications and as directed by
Engineer In-Charge.
Supply and installation of heavy-duty
playground swing set, comprising
swing seats suspended from a powder-
coated steel frame (A-frame or arch-
post design), complete with galvanized
chains, anti-wrap bearings, and safety
30 seat options (belt or bucket type). 2.00 37,370.00 No
Includes all necessary civil works,
concrete foundation, anchoring, and
finishing as per manufacturer’s
specifications. Designed for outdoor
use with UV-resistant and
weatherproof materials.
Providing and Fixing of Exercise
Equipment’s with standard
specifications and selection using
Metal components the metal parts are
made of stainless steel, anodised or
painted aluminium or hot-dip
galvanised steel, and the steel
components are either sandblasted,
treated with epoxy and powdered
paint or given an electrodeposited
coating and then a coat of powdered
paint. The metal components have
excellent weather- resistant
properties and a finished look, they are
also recyclable. as selected by the
Engineer-in-Charge or Architect.
Providing erecting and fixing double
coated ISI water tank of required
32 capacity each with all necessary 5000.00 3.95 Liter
fittings and connection etc. complete
Using AUSTRAILIAN LAWN
development in garden area .and with
application of anti-termite & anti
33 weeding medicine levelling of the soil 166.00 255.03 Sqmt
& planting of grass. selection will be
approved by Engineer in charge and
Providing, supplying, fabricating and
erecting heavy duty pultruded FRP
structural sections of size 100 mm ×
150 mm, UV resistant and fire-
retardant grade, forming triangular
gazebo frame over RCC floor with base
width 7.00 m and overall height
m, including inclined members placed
at 0.40 m c/c (6 Nos. on each side) and
bottom horizontal member, complete
with cutting, drilling and sealing of cut
edges, stainless steel bolts and nuts,
FRP compatible brackets, providing
and fixing MS insert plates
(200×200×10 mm) embedded in RCC
floor or fixed with 16 mm dia chemical
anchor bolts of approved make,
neoprene pad, non-shrink grouting,
alignment, scaffolding, transportation,
labour, tools & tackles and all
incidental works required for proper
installation, complete in all respects as
per approved drawing and as directed
by Engineer-in-Charge, measured in
Running Meter including all materials
Supplying and fixing reinforced
concrete heavy duty non-pressure
pipes with collars for culverts
including setting and joining the pipes
in C.M. 1:2 watering and laying (To
level of slops of I.S. 458 / 1971 Class
NP4 of following internal diameter. (i)
Providing, fabricating and installing
main gate signage structure spanning
between two cabins, consisting of M.S.
structural frame, ACP cladding on both
36 side and back-lit LED channel letters, 14.20 10,403.00 No
including electrical wiring, driver
units, control panel and complete
installation as directed by Engineer-in-
Providing, drilling, installing and
commissioning percolating recharge
borewell for rainwater harvesting
including boring, casing pipe, filter
37 media, slotted pipe, recharge chamber, 1.00 1,21,200.00 No
connection from storm water drain
and all associated civil and plumbing
works complete in all respects as
directed by Engineer-in-Charge.
Security Cabin, Drinking water & Ghat
Excavation for foundation up to 1.5 m
depth including sorting out and
38 stacking of useful materials and 192.00 157.16
disposing off the excavated stuff up to
50 Meter lead. (B) Dense or Hard soil
Excavation for foundation for depth
from 1.5 m to 3.0 m
including sorting out and stacking of
39 useful materials 225.00 301.85
and disposing off the excavated stuff
up to 50 Meter lead.
(D) Soft rock not requiring Blasting
Filling in foundation and plinth with
sand in layers of 20 cm. Thickness Cum
including watering ramming and t
consolidating etc. comp.
Filling available excavated Earth
(Excluding Rock) in trench plinth side
of foundation. in layer not excluding 20 Cum
cm in depth consolidation each t
deposited layer by ramming and
watering etc. complete
Filling foundation and plinth with
murrum or selected soil in layer of
42 cm in thickness including ramming 128.00 301.78
watering and consolidating etc.
Anti-Termite System: Providing and
laying of permanent piping technology
anti-termite treatment before flooring
work by installing LLDP (Low linear
density polyethylene) tube of 8 mm
O.D. & 6.4 mm 1.D. with inbuilt
pressure compensation chip every
cm interval in the tube, having working
pressure of 2 Kg/cm2 and release rate
of 1.9 Itr/hour fixed by P-clips and
nails. The LLDP pipe shall be installed
at the entire periphery of the building
and at internal network of building at
a depth of 20 to 200 mm under floor at
every 2 to 3 mtr. c/c distance (adjusted
as per building layout) & ends of loop
pass through a PVC elbow of minimum
32 mm ID at junction box of wall and
43 floor level, entering into a steel 20.00 134.33 Sqmt
reinforced grooved flexible pipe of
minimum 22 mm ID leading into
junction box and the loops shall
terminate in junction boxes & test
every junction during injecting
chemicals for termite control
treatment. The anti-termite chemical
Imidacloprid 30.5% SC mix as per IS-
6313 (part III) shall be injected by the
pressure pump diluted with water @
10.5 ml/5 ltr of water at the rate of
Kg/sq.cm @ 5 Ltr/SMT. The contractor
shall submit approved line plan for
piping system and junction boxes dully
approved by Engineer-in-Charge with
bond of 5-year warranty. (i)Anti
Termite chemical injected area
(Chemical injecting incl. labour cost)
Providing and laying controlled
cement concrete M150 for curing
complete including cost of formwork
but excluding the cost of Cum
reinforcement for reinforced concrete t
work in (A) Foundations, footings,
Base of columns, Plinth Slab and Mass
Providing and laying controlled
cement concrete M.250 and curing
complete including the cost of
45 formwork and excluding 49.00 5,068.18
reinforcement for reinforced concrete
work in (A) Foundations, footings, and
Mass concrete. footing
Providing and laying controlled
cement concrete M250 and curing
complete including the cost of form
46 work but excluding the cost of 4.00 7,720.44
reinforcement for reinforced concrete
work in Columns, pillars posts and
struts Column Up to Plinth Level
Providing and laying cement concrete
1:3:6 (1-Cement: 3- coarse sand: 6-
machine cut stone aggregates 40 mm Cum
nominal size) and curing complete t
excluding cost of formwork in (A)
Foundation and Plinth
Providing and laying controlled
cement concrete M-200 and curing
complete including the cost of form
48 work but excluding the cost of 7.00 7,686.10
reinforcement for reinforced concrete
work in Columns, pillars posts and
struts G. FLOOR
Providing and laying controlled
cement concrete M-250 and curing
complete including the cost of form Cum
work but excluding the cost of t
reinforcement for reinforced concrete
work in Ground & Plinth BEAMS
Providing and laying controlled
cement concrete M.150 and curing
complete including the cost of Cum
formwork and excluding t
reinforcement for reinforced concrete
work in (C) Plinth Slabs
Providing and laying controlled
cement concrete M.200 and curing
complete including the cost of Cum
formwork and excluding t
reinforcement for reinforced concrete
work in (C) Ground floor Beams
Providing and laying controlled
cement concrete M-200 and curing etc.
complete including the cost of form Cum
work and reinforcement for reinforced t
concrete work in (c) Chhajja for
Providing and laying controlled
cement concrete M-200 and curing etc.
complete including the cost of form Cum
work and reinforcement for reinforced t
concrete work in (c) Lintal for Ground
Providing and laying controlled
cement concrete M.200 and curing
complete including the cost of Cum
formwork and excluding t
reinforcement for reinforced concrete
work in (C) Ground floor Slab
Providing and laying controlled
cement concrete M-200 and curing etc.
complete including the cost of form
55 work and excluding the cost of 2.00 7,182.11
reinforcement etc. complete in (E)
Stair case for Ground Floor to first
Providing IS Mark TMT FE 500D bar
reinforcement for RCC work including
bending & placing in position complete
up to All floor Level
Brick work using common burnt clay
building bricks having crushing
strength not less than 35 kg. /Sq.Cm. in Cum
foundation and plinth in Cement t
Mortar 1:5. (1- Cement: 5 -fine sand)
(B) Conventional below plinth
Brick work using common burnt clay
building bricks having crushing
strength not less than 35 kg. /Sq.Cm. in Cum
foundation and plinth in Cement t
Mortar 1:5. (1- Cement: 5 -fine sand)
(B) Conventional Ground Floor
Providing 20 mm thick double coat
mala cement plaster on interior brick /
concrete work for plastering
comprising of base coat of 12 mm thick
cement plaster in cement mortar (1
Cement: 4 coarse sand) in rough
finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement:
Coarse sand) finished with trovel
including scaffolding curing, 10x10
mm grooves etc. complete. For Ground
Providing 10 mm. thick cement plaster
in single coat for plastering on ceiling
and soffits of stairs and finished even
60 and smooth in: (I) Cement mortar 1:4 20.00 159.20 Sqmt
(1 cement: 4 sand) including Mala
troveled finish etc. complete. Ground
20 mm thick Sand faced cement plaster
with 18x8 mm grooves as suggested by
this office consisting of 12 mm thick
backing coat of C.M. 1:3 (1 cement:
coarse sand) and 8 mm thick finishing
coat of C.M. 1:1 (1 cement: 1 coarse
sand) for all heights as directed etc.
complete. and as per pattern sample
approved by the architect or directed
engineer in-charge
Providing throating or plaster drip and
moulding to R.C.C. Chhajja.
Applying two coats of acrylic lapy
(putty) & two coats of primer of
approved brand and manufacture on
new wall surface to give an even shade
including thoroughly brushing the
surface free from mortar dropping and
other foreign matter and sand papered
Wall painting (two coats) with plastic
emulsion paint of approved brand and
manufacture on undecorated wall
surface to give an even shade including
thoroughly brushing the surface free
from mortar droppings and other
foreign matter and sand papered
Wall painting (two coats) with plastic
emulsion paint of approved brand and
manufacture on undecorated ceiling
surface to give an even shade including
thoroughly brushing the surface free
from mortar droppings and other
foreign matter and sand papered
Wall Painting (Two coats) with
weather proof acrylic emulsion paint
of approved brand and manufacture
and of required shade on exterior wall
surface to give an even shade over and
66 including primary coat with Alkali 226.00 120.26 Sqmt
resistance primer of approved brand
after thoroughly brushing surface to
remove all dust and remains of loose
powdered material etc. copm. for all
Providing and laying controlled
cement concrete M-200 for RCC work
and curing complete including the cost Cum
of form work but excluding the cost of t
reinforced concrete work in coping on
Providing and fixing window having
extruded aluminium Colour anodized
section frame main outer size
Rmt, horizontal two track member size
[email protected] Kg/mt, vertical
68 member of size 61.85 mm x31.75mm x 4.00 1,713.70 Sqmt
1.30 mm @ wt.of 0.659 Kg/mt with
sliding shutters of horizontal member
size 40mm x 18mm x1.29mm @ wt. of
0.456Kg/mt, vertical member of
size40mm x 18mm x 1.29mm @ wt. of
0.456Kg/mt, @ Wt.0.457 Kg/mt with
mm thick transparent bronze colour
tinted float glass with powder coated
aluminium fitting sand fixtures and
transparent silicon sealant glass fixing
to frame as per details etc complete for
Providing and fixing 30mm thick
FACTORY-MADE SOLID PANEL PVC
DOOR SHUTTER consisting of frame
made out of M.S. tubes of 19-gauge
thickness and size of 19mm x 19mm
for stiles and 15mm x 15 mm for top
and bottom rails. M.S. frame shall have
a coat of steel primers of approved
make and manufacture, M.S. frame
shall be covered with 5 mm thick heat
moulded PVC ‘C’ channel of size 30 x
mm forming stiles, and 5mm thick
75mm wide PVC sheets for top rail,
69 lock rail and bottom rail on either side, 5.00 1,146.37 Sqmt
and 10mm (5mm x 2) thick, 20mm
wide cross PVC sheet as gap insert for
top rail and bottom rail, Panelling of
stiles and rails with 30mm wide x 5mm
thick PVC sheet beading on eighter
side, and joined together with solvent
cement adhesive,. An additional 5mm
thick PVC strip of 20mm width is to be
stculk on the interior side of the ‘c’
channel using PVC solvent cement
adhesive etc. complete as per direction
of Engineer in charge, manufacture’s
specification and drawing.
Providing and laying 60 x 60 cm
Machine polished Machine cut Blue
Kota Stone slab flooring over 20 mm
(average)thick base of cement mortar
1:6 (1-cement 6-coarse sand) or L.M
70 1:1.5 (1 Lime putty : 1.5 coarse sand 16.00 1,110.75 Sqmt
laid over and jointed with grey cement
slurry mixed with pigment to match
the shade of slab including rubbing
and polishing etc. complete (A) 30mm
Providing and laying machine cut free
edge machine mirror polished granite
stone 18mm thick finished treads and
risers in Max 260 cm length with 1cm
projecting, nozing rounded moulding
in tread laid over 12 mm (av.) thick
71 bases of cement mortar 1:6 (1-cement 4.00 2,029.26 Sqmt
: 6-coarse sand) jointed with grey or
colour cement slurry including
rubbing and polishing incl. making
Three No.s of grooves of size 3mm X
3mm along the length of treads etc.
Providing and laying water proofing
treatment with china mosaic tiles
flooring over avg 50 mm C.C. 1:2:4
bedding for maintaining slope for plain
and curve surface & 12 mm to 20 mm
of broken piece not more than 2.5CM
of ceramic / glazed tiles ( one for more
colour as directed ) to be laid over
cement mortar bedding of C M 1:3 (1
cement : 3 sand ) contain water
proofing materials per bag of cement
use as specified by manufactured and
slops to be tempered to bring mortar
up to surface with using white cement
and colour pigment including
rounding of junctions and extending
them up to 15 cm along the wall and
curing with bends any patens or
design as per drawing and cleaning by
using oxalic acid etc. complete.
Providing and fixing polished 18 mm
thick Granite stone with full round
edge and polished of approved quality
in cladding on sill and around the
doors/ windows/ ventilation with
mm thick cement plaster CM (1:4) and
fixing with cement slurry & adhesive
including moulding of exposed edges
as directed by engineering in charge
Providing and fixing Safety grills of
required pattern for windows/ Door
using necessary M.S angle/ M.S pipe,
M.S flats and other structural steel at
74 required spacing including cutting, 114.71 112.11 Kg
welding and fabrication etc. including
one coat of primer of approved quality
and two coats of oil painting as per
detail drawing etc complete.
Excavation for foundation up to 1.5 m
depth including sorting out and
75 stacking of useful materials and 1080.00 157.16
disposing off the excavated stuff up to
50 Meter lead. (B) Dense or Hard soil
Excavation for foundation up to 1.5 m
depth including sorting out and
stacking of useful materials and Cum
disposing off the excavated stuff up to t
50 Meter lead. (D) Soft rock not
requiring Blasting
Providing and laying controlled
cement concrete M150 for curing Cum
complete including cost of formwork t
but excluding the cost of
reinforcement for reinforced concrete
Providing and laying controlled
cement concrete M250 and curing
complete including the cost of
formwork and excluding Cum
reinforcement for reinforced concrete t
work in (A) Foundations, Footings and
Mass concrete, Column, Ground/Plinth
Providing and laying controlled
cement concrete M-250 and curing
complete including the cost of form Cum
work but excluding the cost of t
reinforcement for reinforced concrete
work in (d) columns Up to Plinth level.
Providing and laying controlled
cement concrete M-250 and curing
complete including the cost of form Cum
work but excluding the cost of t
reinforcement for reinforced concrete
work in Ground & Plinth BEAMS
Providing and constructing Gabion
Wall of 600 mm width using factory
fabricated double twisted hexagonal
81 woven galvanized steel 4 mm dia GI 540.00 6,228.67
wire mesh filled with hard broken
stone, placed complete in all as
directed by Engineer-in-Charge.
Providing, laying and jointing in true
line and level 110 diametre U.P.V.C
(Type B) conforming to IS 13592-1992
with one end plain and other end
socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of
approved make for drainage system
pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe
82 shall be fixed on wall using of PVC 480.00 878.57 Rmt
clamp of the size 110 mm diametre x
149 mm length x 145 mm heigh at
every 2000 mm center to center or
shall be concealed in walls as directed
including necessary fittings such as
bends, shoes etc. including testing of
pipes and joints and jointed with
adhesive solvent cement including
cost of all materials.
Providing IS Mark TMT FE 500D bar
reinforcement for RCC work including
bending & placing in position complete
up to All floor Level
20 mm Thick Double coat sand faced
Gutka cement plaster on walls up to
height 10 meters above ground level
consisting of 12 mm thick backing coat
84 of c.m. 1:3 (1 cement: 3 sand) and 8 514.00 157.16
mm thick finishing coat of c.m. 1:1 (1
cement: 1 sand) with 1x1cm Groves at
junction of structure member etc.
comp. etc. complete.
Excavation for foundation up to 1.5 m
depth including sorting out and
85 stacking of useful materials and 142.00 278.06
disposing off the excavated stuff up to
50 Meter lead. (B) Dense or Hard soil
Excavation for foundation up to 1.5 m
depth including sorting out and
stacking of useful materials and Cum
disposing off the excavated stuff up to t
50 Meter lead. (D) Soft rock not
requiring Blasting
Providing and laying controlled
cement concrete M150 for curing
complete including cost of formwork
but excluding the cost of Cum
reinforcement for reinforced concrete t
work in (A) Foundations, footings,
Base of columns, Plinth Slab and Mass
Providing and laying controlled
cement concrete M.250 and curing
complete including the cost of
88 formwork and excluding 12.00 7720.44
reinforcement for reinforced concrete
work in (A) Foundations, footings, and
Mass concrete. footing
Providing and laying controlled
cement concrete M-250 and curing
complete including the cost of form Cum
work but excluding the cost of t
reinforcement for reinforced concrete
work in (d) columns Up to Plinth level.
Providing and laying controlled
cement concrete M-200 and curing
complete including the cost of form
90 work but excluding the cost of 518.00 301.78
reinforcement for reinforced concrete
work in Columns, pillars posts and
struts G. FLOOR
Filling foundation and plinth with
murrum or selected soil in layer of
91 cm in thickness including ramming 39.00 6093.33
watering and consolidating etc.
Providing and laying controlled
cement concrete M-250 and curing
complete including the cost of form Cum
work but excluding the cost of t
reinforcement for reinforced concrete
work in Ground & Plinth BEAMS
Brick work using common burnt clay
building bricks having crushing
strength not less than 35 kg. /Sq.Cm. in Cum
foundation and plinth in Cement t
Mortar 1:5. (1- Cement: 5 -fine sand)
(B) Conventional Ground Floor
Providing and laying controlled
cement concrete M-200 for RCC work
and curing complete including the cost
of form work but excluding the cost of
reinforced concrete work in coping on
Providing IS Mark TMT FE 500D bar
reinforcement for RCC work including
bending & placing in position complete
up to All floor Level
Wall Painting (Two coats) with
weather proof 100 % acrylic emulsion
(Apex or equivalent type) paint of
approved brand and manufacture and
of required shade on exterior wall
surface to give an even shade over and
including primery coat with Alkaly
resistance primer of approved brand
after thoroughly brushing surface to
remove all dust and remains of loose
powdered material etc. copm. for all
Constructing providing and fabricating
cattle guard using channel section
frame of size ISMC series 100 mm x
mm (Weight 9.20 kg/Rmt) and ISMC
section 100 mm x 75mm (weight
kg/Rmt) intermediate support for
welding G. I. pipe at 12 Cm C/C of size
97 50 mm in a frame made of Channel 49.00 5229.78 Sqmt
section size 100 mm x 50 mm all round
including fixing the unit on prepared
chamber of masonary wall using MS
hold fast embeded in masonary wall
top as directed by Engineer in charge
and as per drawing and necessary
required arrangement etc complete.
Providing and fixing decorative
entrance slidng gate made out of cast
iron and various mild steel tabular
section combination, the MS gate with
sliding mechanisms of all including
pattern and die making, cutting,
welding, grinding, fabrication, fixing in
98 position at compound wall with 1823.00 167.66 kg
necessary pedestal, bearing block and
other locking arrangement. The
entrance gate should be painted with
two coats of priming coat of paint, and
two coat of oil paint etc complete. As
per detail design and instruction of
Providing and fixing concertina coil
fencing with punched tape concertina
coil 600 mm dia 10 mt openable length
having 50 no rounds per 6 mt length,
up to 3mt height of wall with existing
angle iron (50mm x50mm x 5mm)
required shaped as per Directed
Engineer in charge. placed 2.4mt or
3.00mt apart and with 4 horizontal
99 R.B.T. reinforced barbed wire(3 mm) , 300.00 503.99 Rmt
stud tied with G.I. staples and G.I. clips
to retain horizontal, including
necessary bolts or G. I. barbed wire
tied to angle iron, all complete as per
direction of Engineer-in-charge, with
reinforced barbed tape (R.B.T.)/Spring
core (2.5 mm thick) and weight
gm/meter at compound wall for ESR
M4/ intake well.
Point wiring for Light / Fan/ Bell/
Primary Point with 2-1.5 sq. mm &
earth wire of 1.5 sq. mm (green) both
are of ISI marked 1.1 kv grade FRLS
PVC insulated multi strand copper
wires up to max length of 10 mt, in
below type of pipe erected with 6A
Tissino Type ISI marked flush type
100 switch / bell push and accessories 14.00 390.87 Pt.
erected on Metal / PVC/Wooden Box
covered with 3 mm thick
PC(Polycarbonate) Acrylic/Laminated
sheet. with necessary Lamp
holder/ceiling rose / H. D. Connector
as directed. (f) with medium class
Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete
Point wiring for independent PLUG
with following size mains earth wire of
1.5 sq.mm (green) both are of ISI
marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up
to 10 mt length, in following below of
pipe erected complete with ISI
marked 3 / 5 Pin socket and tissino
type switch erected with earth
continuity connection erected on
Metal / PVC/Wooden box covered
with 3 mm thick PC(Polycarbonate) /
Acrylic/Laminated sheet. [B] 6/16A
Plug and 16-amp switch with 2-2.5 sq.
mm Cu. Mains from mcb d b boards. (f)
with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete.
Point wiring for FAN with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green) both
are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multi strand copper
wires up to 10 mtr length, in below
type of pipe erected with 6A Modular
type switch and hum free EME step
type electronic fan regulator mounted
and accessories with earth continuity
of following type erected on PVC /
Metallic/Wooden box, single mounting
base frame covered with
102 textured/metallic/white front plate 2.00 674.68 Pt.
modules erected on / in wall / ceiling
as per pipe erected. with necessary
ceiling rose / H. D. Connector as
directed. (f) with medium class Rigid
PVC pipe and accessories erected
concealed in wall/ceiling complete
Cat. III (Make: Pipe: Precision /
/nihir, Vinay, Wire: havells, finolex
/polycab / rr kabel/KEI, Acc. Legrand,
Great White Arcus, Havells Crabtree,
L&T Englanze, mk Blanze)
Providing and erecting Mains with
KV grade FRLS PVC insulated ISI
marked stranded Copper conductor
wire in following type of pipe to be
erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated
stranded wire of green colour for earth
continuity of following size (A) With
medium class Rigid PVC pipe and
accessories (b) 2 wire 2.5 sq. mm
(Make : Pipe: Precision /Polycab /nihir
/Astral Wire: havells, finolex
/polycab/ rr kabel/KEI ,Acc. Legrand,
Great White Arcus ,Havells Crabtree,
L&T Englanze, mk Blanze)
providing and erecting Mains with
KV grade FRLS PVC insulated ISI
marked stranded Copper conductor
wire in following type of pipe to be
erected in / on wall / ceiling with
sq. mm copper conductor FRLS PVC
insulated stranded wire of green
colour for earth continuity of following
(A) with medium class Rigid PVC pipe
and accessories.(a) 2 wire 4 sq. mm
(Make : Pipe: Precision /Polycab /nihir
/Astral Wire : Havells, finolex
/polycab/ rr Kabel/KEI ,Acc. Legrand,
Great White Arcus ,Havells Crabtree,
L&T Englanze, mk Blanze)
(b) 2 wire 6 sq. mm (Make: Pipe:
Precision /Polycab /nihir /Astral
Wire: Havells, finolex /polycab/ rr
kabel/KEI, Acc. Legrand, Great White
Arcus, Havells Crabtree, L&T Englanze,
providing and erecting Mains with
KV grade FRLS PVC insulated ISI
marked stranded Copper conductor
wire in following type of pipe to be
erected in / on wall / ceiling with
106 sq. mm copper conductor FRLS PVC 660.00 147.46 Rmt
insulated stranded wire of green
colour for earth continuity of following
size (A) with medium class Rigid PVC
pipe and accessories (b) 2 wire 6 sq.
Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single
MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/
aluminium die cast powder coated
and high U.V. & corrosion resistance
with diffuser with company
mark/name 160V to 270V, Power
Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt, LED LED
driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description
have shown ranges of Wattage
capacity of LED fittings. The Engineer
in charge may select any wattage
capacity between the ranges shown.)
(A) Tube Light with integral driver.
(iv) 22-24 Watts, Surge - 2KV, IP-20,
conventional 4 feet Cat-lll (Make
Philips, Havells, osram, Cree)
(D) LED Strip Light (ii) Minimum 7.2W
240 LED per meter, (2 wire, IP-65)
108 with non-integral suitable Driver 120.00 220.18 Rmt
complete Cat-lll (Make Philips, Havells,
(F) Spot Light 425 Lumens, Surge-2KV
109 (ii) 8 to 11 Watts Cat-lll (Make Philips, 120.00 1,367.54 No
Havells, osram, Cree)
Providing and erecting Miniature
circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C.
system and having breaking capacity
10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI
Mark Cat.III (make: Havells, L & T,
Simens, legrand, ABB, Hager)
Providing & erecting 240 V MCB
double pole switch for motor &
inductive load (C Curve) having 10 KA
breaking capacity & confirms to IS:
8828 in existing box having following
capacity (A) 6 to 32 Amp. Cat.III
(make: Havells & T, Simens, legrand,
(B) 40 Amp. Cat.III (make: Havells, L No
& T, Simens, legrand, ABB, Hager)
Providing and erecting Sheet Steel
powder coated MCB distribution
board - flush / surface mounted fitted
with busbar, neutral link, earth bar and
DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs
should be used of same company of
MCB to be used) suitable for (B) three
phase incoming and single phase
horizontal type outgoing Per phase
isolation type (PPI) (b) sheet steel
double door (ii)6 way (make: Havells
L & T , Simens , legrand, ABB, Hager )
Supplying & erecting approved make
RCCB + MCB (Electromagnetic type
only) working on residual current
device having 10 KA short circuit
breaking capacity and 30 mAmp.
114 Sensitivity & 30 mili sec. tripping time 12.00 1,944.25 No
conforming to IS 12640 test knob
facility trip free mechanism operating
for rated leakage at nominal ten volt,
complete erected including all
materials lugs screws etc. completed.
[b] 32A / 40A, 2 pole Single Phase Cat.
Supplying and erecting LED street light
/ Flood light fittings with High power
White LEDs wattage of 3 Watt and
above assembled on single MCPCB,
efficiency more than 130 lm/w and
corrosion free High pressure die cast
aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and
Polycarbonate optics/ lenses, with
toughened glass with company
mark/name engraved or embossed
160 to 270 V, Power Factor more than
5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %. (fittings
required LM-79 & LM-80 certificates)
(NOTE: Below description have shown
ranges of Wattage capacity of LED
fittings. The Engineer in charge may
select any wattage capacity between
the ranges shown.) (A) Street Light
(IP-65), Surge protection -4KV integral
and, Light must have 440VAC line
supply with over-voltage protection.
(ii) above 48 to 60 Watts
Providing, supplying, installing, testing
and commissioning outdoor type
stainless steel water cooler with
inbuilt water purification system
suitable for garden/public park use,
complete with all fittings, plumbing
connections, drainage arrangements,
electrical connections, protective
covering and civil interface works, as
directed by Engineer-in-Charge.
Supplying, erecting, testing,
commissioning approved make M.S.
Polygonal High Mast Pole having
following general Specification.
(a) Polygonal Section fabricated from
M.S. Plate confirms BSEN 10025 & Hot
deep galvanized minimum 65/86
micron (as per IS
2629 /1985) Lantern carriage with
ring and rubber lines for erection of
luminaries of suitable site.
(b) Maximum telescopic section not
(c) Double drum gear pipe motorized
winch with 6mm dia S.S. Rod (For
mtr and above size)
(d) Approved make L.E.D. aviation
light = 1 No. Lightening arrestor = 1 No.
with necessary wiring of 2.5 sq.mm
core ISI copper cable Unarmoured.
(e) Bottom most section suitable for
mounting reversible motor and
switchgears having door not more
than 1400mm x 300mm with
waterproof gasket & hinges & locking
(f) Pole structure comprises suitable
size of reversible motor, cable and
necessary switchgears with control
panel. (g) bottom section shall have
suitable size of thickness supports ribs
foundation bolts nuts etc.
(h) Item not comprises the cost of
(i) Necessary Cement Concrete
foundation as per IS including testing
& commissioning of the entire
structure for following size of High
Mast poles [4] High Mast 16 Mtr. TOP
A/F 150 Mm, BOTTOM A/F 400 Mm,
No. of Sec. No. - 2, Bottom Thickness -
4 mm, Top Sec. - 3 mm, Size Base Plate
- dia.630 mm x 20 mm thick,
Foundation Bolt Size M24 x 870 mm,
Qty - 12 Nos., Suitable for mounting
Fitting of Light - 10 Nos.
Providing, Fixing and Installation of
floating the Fountain as per given
Details and Specifications The primary
specifications to consider when
selecting fountain pumps are flowrate,
pump head, pressure, horsepower,
power rating, and outlet diameter.
Flowrate of volume discharge through
the pump, usually given in gallons per
minute (gpm) or gallons per hour
(gph). Head defines the energy
supplied to liquid (per unit weight) by
the pump. It is expressed as a column
height of liquid (either vertical lift or
suction), given in feet of head (ft). with
PressureEngineering360's Pump Flow
118 page. For ponds with a pressurized 4.00 2,02,000.00 No
filter, turn the water every two hours
(for a 2000-gallon reservoir, a
gph pump is needed). For most other
types of ponds, turn the water every
hour (2000-gallon reservoir requires a
2000 gph pump) Pipes and tubes must
fit the pump and allow proper flow.
while pump sizes which are too large
will result in an insufficient outlet
velocity or as per the instruction of
Engineer-In-Charge or Architect. At
least 5 HP submersible HP including
filter jali, cable starter panel compl etc
fixing such a way that the water jaam
is not there and easy to maintain
including material and labour compl.
Providing & erecting open well type
horizontal mono block pump set with
stainless steel body having following
specification (C) 1 H.P. single phase
open well motor pump set suitable for
185 LPM discharge @ 25 mtr. head,
suitable for 32 mm dia. Delivery pipe
with control panel. Cat. II complete in
all respects as directed by Engineer-in-
Providing, supplying, installing, testing
and commissioning outdoor
weatherproof electrical plug point
units at every 20 meters along the
garden compound wall/periphery,
complete with wiring, protective
enclosure, mounting arrangement,
earthing and connection from nearest
distribution board, as directed by
Engineer-in-Charge.
Provision of a lumpsum amount
towards supply, installation, testing
and commissioning of additional
electrical items and associated works
required for smooth execution and
completion of the project, to be carried
out as per actual site conditions,
amended working drawings and
instructions of the Engineer-in-
The scope shall include minor
modifications, additional wiring,
fittings, accessories, protection
devices, earthing arrangements, cable
routing adjustments, load extensions,
121 temporary arrangements and other 1.00 12,12,000.00 No
electrical requirements necessary to
commence and continue the work.
The item shall also cover statutory
charges, legal fees, application fees for
electrical connection, electrical
establishment charges, liaisoning,
inspection fees, testing charges and
approvals from competent authorities,
along with all labour, materials, tools,
plants, transportation and incidental
The work shall be executed as directed
by the Engineer-in-Charge and as per
approved drawings and relevant
specifications, complete in all respects.
The all rates are Excluding GST .
I / We agree to carry out the above work at ____________ % above the estimated rate ((In Words)
________________________________________________) percentage above the Estimated Tender Rate.
I / We agree to carry out the above work at ____________ % below the estimated rate ((In Words)
_________________________________________________) percentage below the Estimated Tender Rate.
Estimated Amount Estimated Amount
Put to Tender Rs. 3,33,63,772.00 Put to Tender Rs.
Add % Above Rs. __________ Deduct % Below Rs. ____________
Net Amount Rs. __________ Net Amount Rs. _____________
Net In Figure Rs. _____________ Net in Figure Rs. ______________
I / We have read the Condition mentioned in this tender and agree to abide by the same.
Signature of Contractor Chief Of icer
Hazira Noti ied Area
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DTP Development of Mora Lake.pdf
Schedule-B.pdf
B1 Agreement.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .