Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.8 L+₹8.4 L (57.8%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA 390 002 | VADODARA | VADODARA | GUJARAT | 390002 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
11 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / REPLACEMENT OF ELECTRIC DISTRIBUTION SYSTEM AND PANELS AND CERTAIN OTHER E/M NATURE WORKS AT AFS DEESA UNDER GE (AF) BARODA
2023_MES_618629_1
8830/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹30,000
Yes
5 Jan 2024
13 Sept 2023
18 Oct 2023
13 Sept 2023
11 Oct 2023
27 Sept 2023
14 Sept 2023 - 20 Sept 2023
Amount
Excavation in trenches not exceeding. 1.5m wide and not exceeding.1.5m in depth and getting out soft/loose soil for laying of cables etc complete all as specified and directed
Returing filling excavated soil in trenches including spreading , Leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M&L for Bricks; common burnt clay building bricks, sub-class designation of size 230mm x 115mm x 40mmclass for cable protection complete all as specified and directed
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable complete all as specified and directed Note: Thickness of sand shall be measured after punning.
S&F in trenches /fixed on walls/poles of passing through pipe, XLPE insulated armoured heavy duty LT U/G electric cable with aluminium conductor 1100 volts grade with suitable cable glands as required of following size complete all as specified and directed:-
10 Sqmm x 2 core
16 Sqmm x 4 core
35 Sqmm X 4.0 core
50 Sqmm X 3.5 core
95 Sqmm X 3.5 Core
S&F 95 sqmm 3 core XLPE HT cable in trenches /fixed on walls/poles of passing through pipe, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area with suitable cable glands complete all as specified and directed
S&F 185 sqmm 3 core XLPE HT cable in trenches /fixed on walls/poles of passing through pipe, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area with suitable cable glands complete all as specified and directed
S&F heat shrikable cable jointing kit for 11KV (Earthed) grade cable for outdoor termination shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed
S&F heat shrikable cable jointing kit for 11KV (Earthed) grade cable for outdoor termination shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed
S&F heat shrinkable cable jointing kit for 11KV (Earthed) grade cable for indoor termination shrink type jointing complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95 sqmm complete all as specified and directed
S&F heat shrinkable cable jointing kit for 11KV (Earthed) grade cable for indoor termination shrink type jointing complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95 sqmm complete all as specified and directed
S&F heat shrinkable Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm 3 core complete all as specified and directed
M&Lin replacement for cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling of holes for bolts, in any shape or size and inclusive of one primer coat of red oxide one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed
M&L in replacement of pin type insulator, porcelain, vitreous, white, brown, or green insulator including one galvanized mild steel spindle, two GI washers, and one GI nut 100 mm height , 65mm dia, for 1100 volts grade complete all as specified and directed
M&L in replacement of shackle type insulator, including GI strips of size 31x5mm, 14mm dia washers, insulator bolts & nuts, height 100mm, 115mm dia, for 1100 volts grade complete all as specified and directed
M&L in replacement of HT pin type insulator, porcelain, vitreous, white, brown, or green including one GI mild steel spindle, two GI washers, and one GI nut 150mm dia for 11000 volts grade complete all as specified and directed
M&L in replacement of HT disc type insulator, porcelain, vitreous of 145mm height, 255 mm dia ball and socket type single disc assemble for tension with tension clips for conductors working pressure 11000 volts complete all as specified and directed
S&F in repairs ACSR conductor of any type and size straining properly on insulators and binding with aluminium binding wires, jumpers etc, including fixing to insulators on poles in span and tigtening with permissible sage complete all as specified and directed
M&L in repairs MCCB TPN with all incoming/outgoing connection complete, 4 pole of following size complete all as specified and directed:-
100 Amps rupturing capacity 16 KA.
125 Amps rupturing capacity16 KA
160 Amps rupturing capacity16 KA
Supply and fix in repairs switch air break gang oprated tripple pole, mechanically, operated mounted on insulator and steel frame with operating mechanism working out fromground level for current rating 200 amps suitable for 11 KV complete all as specified and directed
Supply and fix in repairs lightning arrestors expulsion type complete with all fittings transmission class, discharge capacity 65 Kilo amps, suitable for 11 KV complete all as specified and directed
Supply and fix in repairs expulsion fuse single pole 11000 volts above 25 Amp to 50 Amps complete all as specified and directed
Supply and fix in repairs stay assembly comprising stay bow 14 mm dia and 40 cm long, stay rod 20 mm dia and 1.8 M long threaded ends with nuts, stay plate complete all as specified and directed Note: Excavation, earthwork and concrete work shall be measured and paid separately under respective item of BOQ.
S & F Anticlimbing device comprising 2.24 mm dia galvanized steel 2- strand barbed wire with 2 mm dia barbed wrapped spirally round poles, to a length of 0.5 m to 1m clamped and properly secured or as ordered complete all as specified and directed
Suply and fix in repairs 4 sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire, one twin core cable flat or circular two core complete all as specified and directed
Supply and fix GI tubing light grade for protection of cable at wall/trench of size 40mmdia bore complete all as specified and directed
Dismantling old pipes and Supply and fix GI tubing light grade for protectin of LT cable of size 50 mm dia bore complete all as specified and directed
S&F in replacement steel tubular swaged pole complete with cast iron plate base plate, final plug, bolts, nuts and screws as specified type 410 SP-31 of length 9 mtr complete all as specified Note: All excavation and conrete work shall be measured and paid separately under respective item of BOQ.
Supply and fix repairs danger notice plate made out of 1.6 mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, and nuts of approved size for LT 20x 15 cm in size complete all as specified and directed
Supply and fix repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, blts, and nuts of approved size for HT 25x 20 cm in size complete all as specified and directed
M&L for cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of poles/struts/stay etc complete all as specified and directed
M&L cement concrete (1:3:6) type C1 using 20 mm graded stone aggregates for pedestal of poles, all including necessary form work, fair finishing to the exposed surfaces using extra cement complete all as specified and directed
Demolition of old broken PCC coping on existing pole and M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of poles including necessary form work complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including copper Strip 20X3.0 mm as earthing lead by means of bolts, nuts check nuts and washers etc made of brass and connected to earthing test point al as shown in electric pate No 3 of SSR indicated and testing on completion including Excavation and earth work in any rype of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50 mm thick in cement concrete (1;2:4) type B-1 rein forced with welded steel wire fabric (AMP)weight not less than 4 kg/ sqm, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised MS Strip 32 x 6 mm as earthing lead by means of bolts, nuts check nuts and washers etc made of GI and connected to earthing test point al as shown in electric pate No 3 of SSR indicated and testing on completion including Excavation and earth work in any rype of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50 mm thick in cement concrete (1;2:4) type B-1 rein forced with welded steel wire fabric (AMP)weight not less than 4 kg/ sqm, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including Excavation and earth work in any rype of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50 mm thick in cement concrete (1;2:4) type B-1 rein forced with welded steel wire fabric (AMP)weight not less than 4 kg/ sqm, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete all as specified and directed
Supply & laying medium grade GI pipe in trenches, wall/ plinth medium grade with all GI fitting complete all as specified and directed for following size :-
15 mm dia bore.
20 mm dia bore.
25 mm dia bore.
40 mm dia bore.
50 mm dia bore.
80 mm dia bore.
Supply and fix in repair Gun metal gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed for following size :-
15 mm dia size.
20 mm dia size.
25 mm dia size.
40 mm dia size.
50 mm dia size.
Taking down carefully old/unserviceable aluminium/ copper point wiring (light, fan , power, socket etc.) complete including removing unserviceable fittings such as switches, ceiling roses pendants, sockets, lamps holder, brackets, fluorescent tube fitting any type, boards, fan regulators etc. and making good to the disturbed surfaces of wall/floor, etc complete all as specified and directed
M&L for point wiring complete with 1.5 Sqmm single core mutistranded copper conductor & PVC insulated fire retardent cable 650/1100 volts grade ISI marked drawn through and including PVC casing caping of suitable sign but not less than 25mm ISI marked including accessories like bends, tees, junction boxes, fixed on wall/ceiling on and including sunken type pressed steel terminal boxes 1.6 mm thick ( inside wall ) with providing 3 mm thick white laminated sheet top covers including one run of earth continuity PVC insulated copper cable 1.5 Sqmm and connected to earth dolly for the following complete all as specified and directed: -
Note for item No 41.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
One light/ fan point controlled by one switch one way.
One 3 pin 5 Amps, Socket outlet on the same board
One 3 pin 5 Amp.Socket outlet on the independent board.
M&L for point wiring complete with 2.5 Sqmm single core mutistranded copper conductor & PVC insulated fire retardent cable 650/1100 volts grade ISI marked drawn through and including PVC casing caping of suitable sign but not less than 25mm, ISI marked including, accessories like bends, tees, junction boxes, fixed on wall/ceiling on and including sunken type pressed steel terminal boxes 1.6 mm thick (inside Wall ) with providing 3 mm thick white laminated sheet to covers incl, one run of earth continuity PVC insulated copper cable 2.5 Sqmm and connected to earth dolly for the 5/15 Amps on independent board complete all as specified and directed
Note for item No 42.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
S&F modular switch piano one way 6 Amps complete all as specified and directed
S&F modular switch socket combination 5 Amps, 3 pin and 2 pin flush type complete all as specified and directed
S&F in repairs of switch piano one way 5 Amps flush type complete all as specified and directed
S&F in repairs of switch piano one way 15 Amps flush type complete all as specified and directed
S&F in repairs of socket outlet 5 Amps , 3 pin and 2 pin flush type complete all as specified and directed
S&F in repairs of socket 15 Amp, 3pin and 2 pin flush type complete all as specified and directed
S&F in repairs of switch socket combination 5 Amps , 3 pin and 2 pin flush type complete all as specified and directed
S&F in repairs of switch socket combination 5/15 Amp, 3pin and 2 pin flush type complete all as specified and directed
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed
Supply and fix in repiar ceiling rose 2 or 3 terminals, complete all as specified and directed
S&F in repairs of switch modular one module 10 Amps flush type complete all as specified and directed
S&F in repairs of switch modular one modul 15 Amps flush type complete all as specified and directed
S&F in repairs of socket outlet modular two modul 5 Amps , 3 pin and 2 pin complete all as specified and directed
S&F in repairs of socket modular two modul 15 Amp, 3pin and 2 pin complete all as specified and directed
S&F stepped type modular fan regulator , 120W-2 MODULE Complete all as specified and directed.
Supply and fixing in repair straight /Angle bulb holder pvc body complete all as specified and directed. material to be supplied as per demand of qty complete all as specified and directed
Supply and fixing repair in Stepped/socket type electronic fan regulator heavy duty type A/C 240 V complete all as specified and directed
Supply and fixing ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts complete all as specified and directed
S&F MCB DB SPN double door, 230 volts ,8 way complete with bus bar 200 amps capacity and neutral links complete all as specified and directed
S&F MCB SP Isolator single pole, 5 to 30 Amps, 10 KA, 240 volts complete all as specified and directed
S&F MCB SPN 63 Amps, 10 KA,240 volts complete all as specified and directed
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping / PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 4 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth wire and one run of PVC conduit / casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit quoted rate.
Supply and fix electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed
Supply only copper LED Tubelight fitting , ENERGY Efficient 20 Watt 2000 lumen bright light complete all as specified and directed
Supply only LED Tubelight fitting, ENERGY Efficient 20 Watt 2000 lumen bright light complete all as specified and directed
S&F in replacement Supply and fixing motion sensor LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement Supply and fixing motion sensor LED street light fitting 70/72/75 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Disconnecting/dismantling and removing unserviceable power contactor of any description from panel and supply, fixing, connecting and testing in existing panel new power contactor type ML3 of capacity 40 Amps with AC3 rating on 415 Volts AC supply having 2NO+2NC auxiliary contacts complete all as specified and directed Make : L&T cat part No SS90721 or equivalent of make Legrand / BCH/C & S Electric
S&F cylinderical type power factor correction heavy duty capacitor 5 to 30 V complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic remote regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply and fix in repair of street light FRP PVC box with provisioning of 01 No MCB 10 Amps, 10 KA capacity including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp complete all as specified and directed.
Supply and fix in repair of DOL starter 40/50 HP for submersible pump set complete all as specified and directed
Comprehensive maintenance of street light comprising of 45/70/144 watt HPSV/HPMV/LED fitting of any make, model fitted on the pole at any height with any type of fixing arrangement by replacing the igniter, ballast, holder, lamp, flexible wire, lightening the required connections, clamps etc complete all as specified and directed
M&L for preparation of existing old painted surface of any description such as LT/HT steel tubular/PCC electric pole/struts of any height and painted complete including cross arms bracing clamps etc with one coat of aluminium paint and in white/blue alternative strips of 30 cm width each all around the pole up 1.5 M height from ground level/top of PCC copping including writing MES, LT/HT feeder No and pole No (in capital letters) stencil cut decorative manner on pole using fluorescent paint complete all as specified and directed
M&L for stringing existing OH line LT four wire system properly including replacement of binding wires complete all as specified and directed
M&L for stringing existing OH line HT three wire system properly including replacement of binding wirescomplete all as specified and directed
M&L for site clearance of Electrical installation by cleaning of shrubs, vegetation cutting of grass, bush, trees not exceeding 30 mm dia branches and roots and leveling of area and removal of same outside MD land complete all as specified and directed
Repairs to submersible pump set of 40 HP/50HP capacity including taking out from bore well (Approx 170 Mtrs deep ) and carrying out the rewinding with super enameld copper winding wire including varnishing for F class insulation , backing and reinstall in bore well and testing, commissioning complete all as specified and directed Note:- All repair work including replacement of minor repair such as nut, bolts, washer etc. Any major item if required to replace shall be measured and paid separately under respective item of BOQ.
Supply only in repairs lower/upper mechanical seal for 40 HP Submersible pump set, complete all as specified and directed
Supply only in repairs lower/upper oil seal for 40 HP Submersible pump set, complete all as specified and directed
Supply, fixing and fabrication and testing desert cooler in GI body sheet with and including cooler fan motor size/sweep 450mm (fan blade only) 230 Volts, Single phase 50 Hz, 1400 RPM, heavy duty single sheet, totally enclosed. The overall dimesnions of the desert cooler shall not be less than 690mmx690mm x 1020mm with and including following accessories each complete all as specified and directed
(a) Air grill of suitable size made out of 0.5mm PGI sheet including GSS arrangement with a knob for easy and smooth movement. (b) Front side and back side panel incl provn of wood wool cooler pad made out of 1mm thick PGI sheet of suitable size and shape. (c) Water tank height shall not be less than 11 inch made out of 2mm thk PGI sheet. (d) Submersible pump electric driven single phase 230 volts, 50 Hz of suitable discharge and head but motor capacity shall not be less than 18 watt. Make : Khaitan/Crompton or equivalent make. (e) Service cord of 3 Core copper wire 1.5 Sqmm with plug top 5 Amp length not less than 2 metres. (f) Electronic fan dimmer 1000 watts AC 230 Volt for controlling the fan speed. (g) Complete electric wiring of desert coolers as required to operate fan and pump along with 5 Amp switches . (h) Make of cooler fan motor: Khaitan/ Havells/Crompton Greaves/Marathon/Almonard (j) Make of PGI sheet. Tata/Jindal/National
Supply, install, testing & commissioning of CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 HZ , AC supply system having busbars chamber with copper bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 50X50X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following complete all as specified and directed:-
(i) Alluminium bus bar 100 Ams capacity - 04 Nos (ii) MCCB 4 pole 440 volts 35 KA 3 phase , cap 63 Amp - 01 No (iii) MCB SPN 32 Amp 10KA -06 Nos (v) Digital Multi -function meter to measure voltage, Current frequency power factor (digital type ) 0- 300 Amps-01 No
S&F in repair of bracket with clamp of 25 mm dia for fixing street light fitting made out of GI pipe light grade including bending to shape of length 1.5 m complete all as specified and directed
City Light
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .