Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹24.2 L+₹1.8 L (7.92%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹24.3 L+₹1.9 L (8.26%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹24.9 L+₹2.4 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹25.5 L+₹3.1 L (13.6%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
19 Oct 2022, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/ MAINT TO LT UG CABLES, LT PANELS AND SWITCH GEARS AND OTHER ELECTRICAL WORKS AT CTW, INS VISWAKARMA, BV YARD, OLD MO(V), ABE PARK AND CQAE UNDER AGE E/M NO-II OF GE(U-I)(V)
2022_MES_554938_1
8466/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹75,000
Yes
3 Nov 2022
28 Sept 2022
20 Oct 2022
28 Sept 2022
19 Oct 2022
12 Oct 2022
Amount
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil all as directed.
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection . Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
Cutting the tarmac / hard standings and excavating in trenches across the road with a size not exceeding 0.45 mtr wide and 0.6 mtr depth for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5/4 core XLPE , armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs wherever required
16 Sqmm 4 core
25 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
Supply and fix in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps. Make: HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells
Supply and fix in repairs MCCBs of following current carrying capacity. Make: HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells
3 Pole MCCB 315-400 Amps, Adjustable type,415V, 35 KA rating
3 Pole MCCB 250 Amps, Adjustable type, 415 V, 25KA rating
3 Pole MCCB 200 Amps, Adjustable type, 415 V, 25KA rating
3 Pole MCCB 160 Amps, Adjustable type, 415 V, 25KA rating
3 Pole MCCB 32 to 80 Amps, 415 V, 16KA rating
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 50 KA, 630 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 35 KA, 400 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 250 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200 A rated
4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160 A rated
Supply and fix in repairs Isolator, 415 Volts of following current carrying capacity. Make:HPL/C&S/Schneider/L&T/Indoasian/GE/Havells
4 Pole 63 Amps
4 Pole 100 Amps
TPN 100 Amps
TPN 63 Amps
M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . The fault locator will be issued by department for operation
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 35 sq.mm. Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM / DENSON
All as per Item No.14 herein before but for cable of size 3.5 core 50 to 95 sq.mm.
All as per Item No. 14 herein before but for cable of size 3.5 core 120 to 185 sq.mm.
All as per Item No. 14 herein before but for cable of size 3.5 core 240 to 300 sq.mm.
M&L for heat shrinkable Termination Kit for LT UG cable complete for making serviceable for aluminium conductor cable of size 3.5/ 4 core 50 to 95 sq.mm. Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM / DENSON
All as per Item No.18 herein before but for cable of size 3.5 core 120 to 185 sq.mm.
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement complete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizantal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in : - (a) Incoming : ACB high breaking capacity 4 pole 415 volt 35 KA breaking cap adjustable thermal release range 630 Amp -01 No
(b) Outgoing : (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 250 Amp – 02 Nos. (ii) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 200 amp – 02 Nos (iii) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 63 amp – 2 Nos all as directed by the Engr In Charge. Make of ACB/MCCB : C&S /Schneider /L&T / Indoasian /GE /Havells. (iv) Three phase indication lamp along with voltmeter and ammeter. Make : L&T / ABB / Siemens / GE / BCH / Schneider
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement complete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizantal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in : - (a) Incoming : MCCB high breaking capacity 4 pole 415 volt 35 KA breaking cap adjustable thermal release range 400 Amp -01 No
(b) Outgoing : (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 250 Amp – 02 Nos. (ii) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp – 02 Nos. (iii) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 63 amp – 2 Nos all as directed by the Engr In Charge. Make of ACB/MCCB : C&S /Schneider /L&T / Indoasian /GE /Havells. (iv) Three phase indication lamp along with voltmeter and ammeter. Make : L&T / ABB / Siemens / GE / BCH / Schneider
Disconnecting, dismantling of existing feeder pannel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement complete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizantal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in : - (a) Incoming : MCCB high breaking capacity 4 pole 415 volt 35 KA breaking cap adjustable thermal release range 200 Amp -01 No
(b) Outgoing : (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 100 Amp – 02 Nos. (ii) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 63 amp –03 Nos. (ii) Isolator 4 pole 415 volt 16 KA breaking cap adjustable thermal release range 40 amp – 02 Nos all as directed by the Engr In Charge. Make of ACB/MCCB : C&S /Schneider /L&T / Indoasian /GE /Havells. (iii) Three phase indication lamp along with voltmeter and ammeter. Make : L&T / ABB / Siemens / GE / BCH / Schneider
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron or steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia light grade, GI pipe.
medium grade pipe for watering & 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' of SSR and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed.
Pruning/cutting of tree branches of any size beyond 2 mtr from over head lines (LT/HT) including depositing same to a distance as directed by Engineer-in-Charge, complete all as specified & directed.
Stretching/tightening of existing ACSR conductor after loosening binding wire from insulators and removing spacers upto a level to maintain a permissible space between conductors after rebinding the conductor with insulator with 14 SWG GI wire, complete all as specified & directed.
Excavation of cable size 70 Sqmm to 300 Sqmm from its loop, cleaning, cutting of old termination kit and refill of termination kit of suitable size alongwith refilling of cable with sand and bricks all as directed.
Spray painting to complete LT panel with two coats of powder coating paint of approved shade over a coat of red oxide paint after cleaning/ removing dust, rust or carbon etc complete all as specified & directed.
Dismantling old broken cement concrete pole coping complete & M&L for PCC 1:3:6 with 20 mm graded aggregate for coping of poles and stay including form work.
M&L for Maintenance and attending complaints / breakdowns at INS Viswakarma, BV Yard, CTW and In-Living Complex area comprising of LT panels, over head lines/ underground LT cables upto main distribution boards at buildings including repairs of day to day maintenance of LT panels/Perimeter lights for smooth & trouble free LT power supply as directed by Engr-In-charge including rectification of minor defects to electrical controls gear/accessories.
Note :- The rate quoted is inclusive for the following :-
(i) (a) Attending minor repairs/breakdowns without involving any new (major) materials. (b) Cost includes the tools for attending break down and minor materials like lugs and PVC tapes,Job Cards and Complaint registers etc. (c) Major repairs,Break downs invloving S&F of materials such as cables,Joints,MCCBs etc are out side the scope of this item and shall be measured and paid separately.
(ii) Contractor should ensure to carry out the work through qualified Technician/Electrician and assisted by the helper. Necessary tools & plants and transportation charges are deemed to be included in the unit rate quoted. (iii) On completion of the task/attending break down necessary Job card duly signed by the stake holder.
MONITOR ENGINEERING WORKS
SRI SRK ENGINEERS
Datha Engineering Enterprises
VENKATESWARA ENGINEERS AND CONTRACTORS
MSN ENGINEERING WORKS
SUPREET CONSTRUCTIONS
SRI MAHALAKSHMI CONSTRUCTIONS
DELTA CONSTRUCTIONS
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
AARAV POWER CONTROLS
GS ENGINEERS
Saket Enterprises
Bhuvaneswari Electrical Works
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .