| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | ₹2.4 L | L1 | Accepted-AOC since the lowest |
| 2 | L2₹2.4 LRejected-Finance VILL BUZRUCKCHANDRA P O BKTPP P S SADAIPUR BIRBHUM 731104 | BIRBHUM | BIRBHUM | WEST BENGAL | 731104 | ₹2.4 L | L2 | Rejected-Finance MORE THAN THE LOWEST |
| 3 | L3₹2.4 LRejected-Finance | ₹2.4 L | L3 | Rejected-Finance MORE THAN THE LOWEST |
| 4 | L4₹2.4 LRejected-Finance UNNAYAN BHAWAN BLOCK A 7TH FLOOR SALT LAKE CITY KOLKATA 700091 WEST BENGAL INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹2.4 L | L4 | Rejected-Finance MORE THAN THE LOWEST |
| 5 | Rejected-Technical AG 112 SALT LAKE CITY SECTOR II UNIT 608 6TH FLOOR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | - | - | Rejected-Technical Submitted document not at per with the N.I.T. |
Tender Value
₹2.4 L
EMD Value
₹4,733
Closing Date
9 Mar 2026, 11:00 amClosed
The Assistant Engineer, BNWSD-I, Purta Bhavan
The Assistant Engineer, BNWSD-I, Purta Bhavan, Room No 125
Emergent repairing of the Godown lying in the Ground floor of the premise of West Bengal Board of Primary Education in Acharya Prafulla Chandra Bhavan, DK-7/1,Sector-II, Salt Lake City,Kolkata-91, during the year 2025-2026.
2026_WBPWD_1017235_1
AE/BNWSD-I/NIT-12e/2025-2026
Open Tender
CIVIL WORKS
21 days
Purta Bhavan, Salt Lake, Sector I, Kolkata-700091
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,733
Yes
18 Mar 2026
2 Mar 2026
11 Mar 2026
3 Mar 2026
9 Mar 2026
3 Mar 2026
Taking out Mirzapur or glazed porcelain tiles carefully by chiselling from walls or floor including stacking serviceable material as directed
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. a) 25 mm thick
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar (a) 10 mm thick plaster
(i) With 1:6 cement mortar (a) 20 mm thick plaster
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) i) Standard Quality
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 32 mm thick shutters (single leaf)
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (i) 100mm. X 58mm. X 1.90mm
Iron socket bolt of approved quality fitted and fixed complete. (a) 225mm long x 10mm dia bolt
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white
(b) On steel or other metal surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white
Providing and fixing of factory made UPVC casement window ( White colour) ( U value-1.9-1.3 w/m 2k, flame resistant, self extinguishing, lead free) comprising Upvc multi-chambered frame, Sash, & Mullion with having wallthickness of 2.3 mm ( +0.2mm) duly reinforced wit G.I section 1.6mm ( + 0.2mm) made from a) Fixed window frame of size 67 x 62 mm & Mullion ( if required) of size 67x78mm both having wall thickness of 2.3+0.2mm
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II) (i) 8mm thick
Supplying and affixing optically clear polyester sun control window film having acrylic pressure sensitive adhesive on one side & an acrylic abrasion resistant coating on the other, with composition of infrared absorbing carbon & free from any optical defect. The film characteristics should conform to ASTM E308, ASTM E903, ASTM E84 and ASHIRAE. The film should be pasted after preparatory works without any cracking, delamination, bubbling, discolouring and variation in total transmission of light across the width at any portion along the length doesn't exceed 2% over the average including scaffolding & relevant others to complete in all respect as per manufacturer's specification & direction of Engineer -in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) Normal Quality : Film Thickness - 1.0 Mil, Glare Reduction > 45%, U factor < 1.15
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 1.27 MB
BOQ_2499571.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid