Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.7 LAccepted-AOC PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹78.4 L+₹4.6 L (6.30%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L2 | Rejected-Finance Higher Bid Value |
Tender Value
₹76 L
EMD Value
₹1.4 L
Closing Date
4 Jan 2020, 6:00 pmClosed
CWE EZHIMALA
CWE EZHIMALA INA EZHIMALA PO KANNUR KERALA 670310
Provision of interconnection for existing bore well and sump with filtration plant to RL-30 pump house at INA Ezhimala
2019_MES_308342_1
80394/E8
Open Tender
Civil Works - Water Works
Item Rate
90 days
EZHIMALA
As per NIT
2 documents required · 2 mandatory
₹1,000
GE (Maint) Ezhimala
₹1.4 L
Yes
16 Jan 2020
21 Dec 2019
6 Jan 2020
21 Dec 2019
4 Jan 2020
27 Dec 2019
21 Dec 2019 - 27 Dec 2019
Amount
LIST OF ITEMS OF WORKS
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation over areas n.exc. 1.50m deep and getting out in hard/dense soil complete all as specified and as directed.
Excavation over areas n.exc. 1.50m deep and getting out in soft/disintegrated rock complete all as specified and as directed.
Excavation over areas depth exc. 1.50m but n.exc.3.00m and getting out in hard/dense soil complete all as specified and as directed.
Excavation over areas depth exc. 1.50m but n.exc.3.00m and getting out in soft/disintegrated rock complete all as specified and as directed.
Excavation over areas depth exc. 1.50m but n.exc.3.00m and getting out in hard rock by chiseling complete all as specified and as directed.
Excavation in trenches n exc. 1.50m wide and n exc 1.50m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sqm on plan and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and wall ramming in layers not exc 25cm thick with soil obtained from excavation complete all as specified and as directed.
Spreading, levelling, watering and wellk ramming in layers n exc. 25 cm thick in filling under floor with soil/rock obtained from excavation complete all as specified and as directed.
Removal of surplus excavated spoil to a distance exc. 1.50Km and n.exc. 5.0Km and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Removal of surplus excavated spoil to a distance n exc 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping with and including use and waste of formwork complete all as specified and as directed.
M&L for RCC M-30 (Ready Mix Concrete) using 20mm graded stone aggregate as in footings complete all as specified and as directed.
M&L for RCC M-30 (Ready Mix Concrete) using 20mm graded stone aggregate as in walls complete all as specified and as directed.
M&L for RCC M-30 (Ready Mix Concrete) using 20mm graded stone aggregate as in beams, slab supported on walls etc complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slabs/lintel including use and waste of form work set in cement mortar 1:4 complete all as specified and as directed.
M&L for precast cement concrete block masonry with solid blocks type C1, 1:3:6 (using 20mm graded stone aggregate), exc. 10 cm in width and setting in mortar CM 1:6 complete all as specified and as directed.
Use and waste of formwork to sides of footings, rough finished flat vertical surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to faces of walls, rough finished curved vertical surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams/slabs/lintel beams, rough finished flat surfaces of concrete complete all as specified and as directed.
S&F 9mm thick prelaminatd particle board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to aluminium/timber frame work complete all as specified and as directed.
S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc. complete all as specified and as directed.
S&F aluminium powder coated door shutters, aluminium section weighing 0.55Kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F aluminium powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F 100mm size brass, 4 levers mortise lock, vertical type complete all as specified and as directed.
S&F 150mm long aluminium, anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and overall length of cover plate 140mm complete all as specified and as directed.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staple complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.50Sqm in each pane complete all as specified and as directed.
M&L for TMT bars 10mm dia and over Corrosion Resistant Steel, cut to length bent to shape required including cranking bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Supply, fabricate and fix mild steel work as in bands, straps, supports or stays for rainwater, plate washer etc and similar small articles conforming to Fe.290. Gde-E-165 complete all as specified and as directed.
Supply, fabricate and fix mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, ladders framed balusters, railing etc. and similar work conforming to Fe.290. Gde-E-165 complete all as specified and as directed.
Supply, fabricate, erect and fix in position mild steel work in tubular trusses (circular and rectangular) and including shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 for round tubes and conforming to IS 4923-1968 Grade St-240 for square or rectangular tube complete all as specified and as directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, tile pattern having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 100 mm thick,(using 40 mm graded stone aggregate ) as in filling and mass concrete.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) 50mm thick as in floor and finishing top surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 75mm thick cement concrete1:3:6 type C2 (using 40 mm graded stone aggregate) finished top surface even and smooth without using extra cement as in plinth protection etc. complete all as specified and as directed.
Rendering 15mm thick plaster in CM 1:4 on concrete surfaces with using water proofing compound complete all as specified and as directed. NOTE :- Water proofing compound shall be measured and paid separately under resepctive item of BOQ.
Rendering 15mm thick plaster in CM 1:3 on brick or concrete surfaces other than fair faces of internal walls and finishing the surface even and smooth, mixing with WPC complete all as specified and as directed. NOTE :- Water proofing compound shall be measured and paid separately under resepctive item of BOQ.
Rendering 15mm thick plaster in CM 1:6 on brick or concrete surfaces other than fair faces of internal walls and finishing the surface even and smooth complete all as specified and as directed.
Rendering 10mm thick plaster in CM 1:4 on concrete surfaces finished surface even and smooth without using extra cement, using WPC complete all as specified and as directed. NOTE :- Water proofing compound shall be measured and paid separately under resepctive item of BOQ.
Supply only water proofing compound of make IMPERMO/ACCOPROOF complete all as specified and as directed.
Preparing new plastered surfaces of walls and applying two coats of oil emulsion distemper over priming chalk whiting complete all as specified and as directed.
Preparing new plastered surfaces of walls and applying two coats of antifungal paint Apex ultima or equivalent over one coat of primer complete all as specified and as directed.
Preparing new surfaces of any description over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed.
Forming construction joint 60mm deep X 10mm wide filled with sealing compound type 'A' complete all as specified and as directed.
M&L for 150mm wide PVC water bar with rubber coating at every construction joint complete all as specified and as directed.
Supply, laying and testing galvanized iron pipe, 'medium grade' 50mm dia including all fittings complete all as specified and as directed.
Supply, laying and testing galvanized iron pipe 'medium grade' 40mm dia ncluding all fittings complete all as specified and as directed.
S&F gun metal gate valve, with iron wheels head, screwed both ends for iron pipe of size 50mm (2") dia complete all as specified and as directed.
S&F gun metal gate valve, with iron wheels head, screwed both ends for iron pipe of size 40mm (1.5") dia complete all as specified and as directed.
Supply and fix Monoblock pump set suitable for 415V, 3 phase suction delivery 80X65, head 22.0m and discharge 19Lps having capacity 10 HP/7.5 KW complete all as specified and as directed. NOTE:- Unit rate quoted by the tenderer shall deemed to include foot valve, sucion pipe.
Supply and fix Horizontal open submersible pump set suitable for 415V, 3 phase suction delivery 80X65, head 22.0m and discharge 19 Lps having capacity 10 HP/7.5 KW complete all as specified and as directed. NOTE:- Unit rate quoted by the tenderer shall deemed to include foot valve, sucion pipe.
Supply and fix Monoblock pump set suitable for 415V, 3 phase suction delivery 80X65, head 22.0m and discharge 11.6 Lps having capacity 5 HP/3.7 KW complete all as specified and as directed. NOTE:- Unit rate quoted by the tenderer shall deemed to include foot valve, sucion pipe.
Supply and fixing petrol engine driven mono block pump set of capacity 3HP with flexible hose 30.0m complete all as specified and as directed. Make :-Honda/Crompton
Supply, laying and testing ductile iron pipe spigot and socket ends, centrifigully cast class K-9 of size 100 mm (4") dia complete all as specified and as directed.
Supply, laying and testing cast iron pipes with spigot and socket ends centrifigully cast class LA, of size 80 mm (3") dia complete all as specified and as directed.
Tyton joints with rubber gasket for DI spigot and socket pipes and fitting of the size 100 mm dia complete all as specified and as directed.
Tyton joints with rubber gasket for DI spigot and socket pipes and fitting of the size 100 mm dia complete all as specified and as directed.
Supply and install Non return valve 100mm dia bore and fixing up in cast iron water supply mains complete all as specified and as directed.
Supply and fix sluice valve, flanged end of class PN 1.6 with stainless steel spindle with all accessories suitable for size 80mm bore, confirming to IS specification complete all as specified and as directed.
Supply and fix sluice valve, flanged end of class PN 1.6 with stainless steel spindle with all accessories suitable for size 80mm bore, confirming to IS specification complete all as specified and as directed.
Supply and fix DI Specials suitable for K-9 pipes, bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socketetc) Tee pieces single branch:Y" juction, double branch, cross all sockets or socket and spicgot collars,caps and plugs) complete all as specified and as directed.
Supply and fix CI Specials suitable for K-9 pipes, bends (any type, radiusand angle) tapers any type, (straight, bend, increasing, decreasing or double socketetc) Tee pieces single branch:Y" juction, double branch, cross all sockets or socket and spicgot collars,caps and plugs) complete all as specified and as directed.
Road cutting of size 30cm width and 60cm depth in any specification and making good with PCC 1:2 :4 type B-1 (using 20mm graded stone aggregate) complete all as specified and as directed.
Supply, laying, testing and commissioning in trenches/wall/floor under ground electric cable XLPE insulated, armoured heavy duty with aluminium conductor 1100 volts grade of cross sectional area 50 Sqmm, 3.5 core complete all as specified and as directed.
Supply, spreading and punning natural river sand/riddled earth for cushioning/protection tp cable complete all as specified and as directed. NOTE :- Punned thickness shall be measured and paid.
Supply and laying unreinforced precast concrete cable cover, class LV type-I, flat of size 250mmX150mmX40mm complete all as specified and as directed.
Supply, install, testing and commissioning Pressure filter of flow rate capatity 50000 litre/hr (Maximum flow rate 30-50m3/hr and back wash flow rate 3-50m3/hr) of size1200mm diax1150 mm vertical height,shell thickness 6mm made constructed in mild steel with two coats of FRP coating inside and outside surfaces all as per manufactures specification and drawing complete including and comprising following:- (a) Inlet distributor set , (b) 05 Nos butterfly valves of 80 mm dia and set of mutually operated multi port valves, (c) Initial charging of filter media consisting washed pebbles, coarse gravel,fine sand and silx, (d) Set of inlet and outlet sample valves,(e) 08 mm thick MS dish end,(f) Chlorine re-generation,(g) Re-generation chemicals with necessary pipe works, (h) Valves and fittings of suitable size dia for connecting the filter equipment from installation point to water source, (j) Foundation of 2600mmx2600mm with 50cm RR peackage with 10 cm thick PCC 1:2:4 including 10 mm thick external plaster and cement base painting. (Note:- (i) Different size/type of filter media and sand shall be measured and paid separetly under respetive item of these schedule. ii) Cost of pipe ,valves,transportation charges ,installation and testing charges shall deemed to be included in this item. (iii) Contractor has to submit detailed specification and drawing of pressure filter from the manufactures for approval). Make :- Cochin Aqua Purifiers/ION Exchange india Ltd /CAP.
Supply and laying filter media of different size/grades of pebbles 5 to 10 mm, silex, fine sand and coarse gravel etc complete all as specified and as directed.
Supply and laying iron removal media type MN O2 complete all as specified and as directed.
Supply and fixing Chlorine dozing pump with tank capacity of 100 ltrs complete all as specified and as directed.
Supply, fixing, testing and commissioning LT feeder pillar panel cubical type, double door opening fabricated using 2.0 mm thick MS sheet and on angle iron frame of 40x40mm angle iron frame, smoke grey powder coated, all as per IS specification and consisting of following :- (a) Model type DU 200 MCCB 200 Amps, 4 Pole, BC 25KA - 01 No (incoming) (b) MCCB 63 Amps, FP - 06 Nos (Out going) (c) MCB 40 Amps,DP - 02 Nos (Out going) (d) DOL starter for 10 HP mono block pump set-04 Nos (e) Supply and fix cencer system automatic on/off for 10HP Pump -04 Nos (f) Digital Volt meter - 01 set (g) Digital Ammmeter - 01 set (h) Aluminium busbar, 200 Amps capacity suitable for 4 wire, Note:- (i) The unit rate quoted by the tenderer is deemed to include : (a) Conncting of incoming and outgoing cable with necessary glands and lugs (b) Outgoing copper cable of suitable size from panel board to pump set.
Supply, fixing, testing and commissioning LT feeder pillar panel cubical type, double door opening fabricated using 3.15mm thick MS sheet and on angle iron frame of 40x40mm angle iron frame, smoke grey powder coated, all as per IS specification and consisting of following :- (a) Model type DU63 MCCB 63 Amps, 4 Pole,BC 25KA - 01 Nos (incoming) (b) MCCB 32mps, FP - 03 Nos (Out going) (c) DOL starter for 10 HP pump set.-04 Nos (d) Digital Volt meter - 01 set (e) Digital Ammeter - 01 set (f) Aluminium bus bar, 200 Amps capacity suitable for 4 wire, 415 volt, 50 Hz AC system. (g) Censer system automatic On/Off for 10 HP pump- 04 Nos Note:- (i) The unit rate quoted by the tenderer is deemed to include : (a) Conncting of incoming and outgoing cable with necessary glands and lugs (b) Outgoing copper cable of suitable size from panel board to pump set.
LUCKY ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .