Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
24 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
MAINTENANC
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650 V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650 V.Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected.
Similar Nature of Work: Supply, installation, testing and commissioning of LT/HT electrical GS assets ORSupply, installation, testing and commissioning of electrification or rewiring of building/workshop. ORSupply, installation, testing and commissioning of Yard/circulating area/street lighting/tunnel/facade lighting. ORSupply, installation, testing and commissioning of high-mast lighting. ORSupply, installation, testing and commissioning of glow signages. ORSupply, installation, testing and commissioning of LT/HT electrical GS sub-station with at least 50% capacity of proposed sub-station ORRepair/overhauling of LT/HT electrical GS assets including LT/HT sub-stations.
49 conditions · 8 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc., and corresponding documents shall be submitted by the tenderer as per the composition of the Firm.
The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA of GCC and shall be valid for a period of 90 days beyond thebid validity period. Non-submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non- submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids.
Eligibility criteria: Eligibility criteria shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
Tender Form (First sheet, Second sheet) of The GCC April 2022.
Certificate format (Affidavit) which available as Annexure - V in Mandatory documents. A facility has already created for online submission of Annexure V of GCC in IREPS module; uploading of physically signed Annexure V by tenderer has been discontinued
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc.
The corresponding documents shall be submitted by the tenderer as per the composition of the Firm: Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) above. HUF: (i) A copy of a notarized affidavit on Stamp Paper declaring that he who is submitting the tender onbehalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. Partnership Firm: (i) All documents as mentionedin para18 of the Tender Form (Second Sheet). Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company(backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above. LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders/contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were/are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para10 of the Tender Form (Second Sheet). Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents andcreate liability against the Society/Trust.(iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as per Clause No.5 of PART -1 of The GCC, April 2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Guntakal Division: Gooty- Re-flooring of ROH shed and allied works at BOXN ROH depot-Electrical Arrangements
GTL-EM-41-2026-27~SCOR
GTL-EM-41-2026-27
Open
Works - General
6 Months
Anantapur, Andhra Pradesh
₹0
₹2.2 L
2 Sept 2026
2 Sept 2026
10 Sept 2026
325 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 52,07,490.65 | ||
| details. | Item Breakup for | — | — | ||
| Supply and Erection of LED street light fittings of 70W with suitable driver with all connected materials as per attached Railway specification. | — | — | — | 1,86,600 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of RCCB 2P 25A 30mA with metal enclosure. RCCB conforming to IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity as advised by the site supervisor with all necessary accessories complete | — | — | — | 27,189 | |
| details. | Item Breakup for | — | — | ||
| Supply, Erection, Testing and Commissioning of RCCB 4P 63A 100mA Sensitivity conforming to o IS 12640 (Part 1) : 2024 with 10 kA short circuit withstand capacity with all necessary accessories complete as advised by the site supervisor. | — | — | — | 37,899 | |
| details. | Item Breakup for | — | — | ||
| Fabrication and erection of 14 SWG CRCA sheet steel enclosure of suitable size for outdoor distribution Panel with IP 55 protection, plinth-mounted with double door, including cutting, bending, drilling, welding, and revetting etc, complete with cleaning with 7 tank process and painting with EPOXY powder coating including cost and conveyance of all materials and labour charges. The MDBs shall be mounted on suitable required size of CC plinth (CC plinth cost will be paid separately)/ wall mounted and secured with bolts, nuts and washers as advised by Engineer at site. The panel comprising of 500A tinned Copper Bus Bar(RYB & N of same size) as per IS 613: 2000 or latest amendment required shape supported with appropriate DMC / SMC barriers and colour coded with heat shrinkable sleeves, LT 3 Phase Digital Multifunction energy meter with 3 lines LCD display for measuring all the parameters( Voltage/ Current/ Power/Frequency/power factor /kw/kwh/ kvar/kvarh) , Current T/Fs, indication lamps for incoming & outgoing feeders. support insulators, neutral links, Incoming & outgoing terminals, suitable cable termination glands , grommets, lugs, connecting wires and all other accessories suit with the following switchgear and accessories. Suitable busbars has to provided for the incoming of all the MCCB's from main busbar. The cables should be properly terminated in the switchgear with necessary lugs and all necessary accessories complete. Drawing approval should be taken before fabrication. The panel should conform to IS/IEC 61439 in all respects. The panel should comprise of the following Switchgear Supply and installation of 250 A 4P MCCB, 36 KA, Micro processor based adjustable with LSIG protection communcation capable conform to IEC 60947-2 model no. 4205 39 of Legrand make or it's equivalent with extended ROM , spreader links (2 sets), - 1 nos Supply and installation of DPX3 160 thermal magnetic-based release; Icu = 36K A; 100A 4 Pole MCCB conform to IEC 60947-2 of model no. 4200 95 of Legrand make with extended ROM , spreader links (2 sets), - 2 nos Supply and installation of 160 A 4P MCCB, 36 KA, microprocessor-based, adjustable with LSIG protection, conform to IEC 60947-2 model no. 4205 37 of Legrand make or it's equivalent with extended ROM , spreader links (2 sets), 2 Nos.Supply and erection of LT 3 Phase Digital Multifunction energy meter with 3 lines LCD display for measuring all the parameters( Voltage/ Current/ Power/Frequency/power factor /kw/kwh/ kvar/kvarh) on existing box panel board, including connections complete.- 1 nos. Supply and erection of LED indicator lamps on the existing box panel board- 5 sets of 3 nos( RYB). The panel should conform to RDSO Lr no: RDSO-EEM0LKO(GENE)/4/2026 Dated 21-07-2026. | — | — | — | 2,29,911 | |
| details. | Item Breakup for | — | — | ||
| Supply and Laying of 4-core 150 sq mm XLPE-insulated underground armoured aluminium cable with heat-resistant insulation as per IS 7098(Part 1): 1988 or latest amendment. Connecting of cables is to be done with proper Al/Cu lugs of appropriate size. | — | — | — | 3,95,270 | |
| details. | Item Breakup for | — | — | ||
| Supply fixing, of HDPE pipe of 75 mm outer dia of PE-100,PN6 class as per IS 4984- 2016 or latest amendment with suitable couplings and clamps for cable laying with all necessary accessories complete. | — | — | — | 90,500 | |
| details. | Item Breakup for | — | — | ||
| Supply and Laying of 4 core 70 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988. | — | — | — | 2,64,620 | |
| details. | Item Breakup for | — | — | ||
| Supply and laying of HDPE pipe of PE-80 grade in PN-4 size outer dia 63 mm as per IS 4984-2016 or latest amendment with suitable couplings and clamps for cable laying with all necessary accessories complete. | — | — | — | 1,63,500 | |
| details. | Item Breakup for | — | — | ||
| Supply and Laying of LTUG 4 core 50 sqmm XLPE insulated PVC sheathed Aluminium armoured cable as per IS 7098(Part 1)1988 or latest amendment. Make Torrentt, Polycab, Havells, KEI, Gloster. Connecting of cables is to be done with proper Al/Cu lugs of approprate size. | — | — | — | 3,44,680 | |
| details. | Item Breakup for | — | — | ||
| Supply and Laying of 4 core 35 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS standard IS 7098(Part 1): 1988 or latest amendment. | — | — | — | 1,22,340 | |
| details. | Item Breakup for | — | — | ||
| Supply of Laying LTUG 4 core 25 sqmm XLPE insulated PVC sheathed Aluminium armoured cable as per IS 7098(Part 1)1988 or latest amendment. Laying of LTUG cable in the trench and connected at both the ends complete. | — | — | — | 1,02,740 | |
| details. | Item Breakup for | — | — | ||
| Supply & Laying of HDPE pipe of 50 mm outer dia of PE-100,PN6 class as per IS 4984- 2016 or latest amendment with suitable couplings and clamps for cable laying with all necessary accessories complete. | — | — | — | 80,000 | |
| details. | Item Breakup for | — | — | ||
| Supply and running of 8 SWG GI earth continuity wire complete with connections. | — | — | — | 36,000 | |
| details. | Item Breakup for | — | — | ||
| Supply and laying of HOFR Aluminium Conductor welding cable with general purpose HOFR compound covering as per IS:9857/1990 (Re affirmed 2020) with Amendment No.1/2007.with the following nominal area of conductor cable are at 60% duty cycle and 30 degree centigrade ambient temperature of the size 120 Sq mm, | — | — | — | 18,358 | |
| details. | Item Breakup for | — | — | ||
| Supply of 3 core 10 sq mm Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments | — | — | — | 2,34,990 | |
| details. | Item Breakup for | — | — | ||
| Excavation of cable trench in all types soil (rocky soil) of size of size 400mm wide x 1 mtr. deep, and making good of the same to its original form and shape after complete including all connected materials and works up to the satisfaction of the Engineer at Site.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge. | — | — | — | 2,34,090 | |
| details. | Item Breakup for | — | — | ||
| Excavation of cable trench in cement concrete bed flooring by using power drill to a depth of 1.0 Mtr and a width of 0.3mtr. After laying the pipe and refilling the trench with excavated earth and undertaking cement concrete bed flooring to its original shape as was prevailing earlier to the satisfaction of Railways site Engineer.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge. | — | — | — | 1,34,028 | |
| details. | Item Breakup for | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 1.5 sq. mm FRLS Cu. Conductor | — | — | — | 90,000 | |
| details. | Item Breakup for | — | — | ||
| Supply, laying, connecting and commissioning of Single core 2.5 Sq.mm. 1100 PVC (FRLS) insulated multi stranded copper conductor wires confirming to IS:694/1990 and ISI marked in existing PVC conduit pipe | — | — | — | 60,000 | |
| details. | Item Breakup for | — | — | ||
| Supply, running, Connecting of 1 core 4Sqmm FRLS, PVC insulated Copper conductor cable of Havells make/Finolex/L&T make with necessary accessories like cable ties etc. | — | — | — | 38,000 | |
| details. | Item Breakup for | — | — | ||
| Supply, running, Connecting of 1 core 6Sqmm FRLS, PVC insulated Copper conductor cable of Havells make/Finolex/L&T make with necessary accessories like cable ties etc. | — | — | — | 93,000 | |
| details. | Item Breakup for | — | — | ||
| "Supply and fixing of Jumbo Ceiling Rose- with auto safe lock equivalent to model no: GM 8224 of GM make" | — | — | — | 1,410 | |
| details. | Item Breakup for | — | — | ||
| — | — | — | 5,500 | ||
| and erection of 6A make comply with | tio n :- S u p p l y Legrand/Havells/GM/Goldmedal | — | — | ||
| — | — | — | switch | ||
| details. | Item Breakup for | — | — | ||
| Supply, fixing, connecting and commissioning of 6A 5pin modular plug socket, with 6A modular control switch on existing control board with wiring. | — | — | — | 10,539.9 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 16 Amps 3/5 pin flush type power plug and socket with modular type switch control including all accessories. Make/Brand: Legrand/C&S/L&T/Indo-Asian/Havells only. | — | — | — | 4,335.75 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 16A SP MCB of B curve IS/IEC 60898-1 (2002) 10 kA breaking capacity IP20 protected terminals | — | — | — | 15,240 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of surface mounting plastic gang box-4 module of model no:JS 04 0 0 3 of GM make with 4 module cover plate(With support frame) of model no:PK SB 04 004 - CASABLANCA of GM make or equivalent modular Legrand/Havells make comply with IEC 60669-1 including all accessories complete. | — | — | — | 4,161.08 | |
| details. | Item Breakup for | — | — | ||
| Supply and Fixing of Surface mounting plastic gang box-8 module of model no:JS 08 0 0 6 of GM make with 8 module cover plate With support frame) of model no:PK SB 08 011 - CASABLANCA of GM make or equivalent modular Legrand/Havells make comply with IEC 60669-1 including all accessories complete. | — | — | — | 10,607.52 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of surface mounting plastic gang box-12 module of model no:JS 12 008 of GM make with 12 module cover plate With support frame) of model no:PK SB 12 007 - CASABLANCA of GM make or equavalant Legrand/Havells make comply with IEC 60669-1 including all accessories complete. | — | — | — | 8,041.8 | |
| details. | Item Breakup for | — | — | ||
| Supply and Running of 25 mm dia, Ivory coloured PVC conduit ( ISI marked) of wall thickness not less than 2 mm along with junction boxes, bends, elbows and all accessories etc. as required as per site requirement. Running of conduit, fixing with suitableclamps and nuts in groove / open /shelter | — | — | — | 72,960 | |
| details. | Item Breakup for | — | — | ||
| Supply and running of 32 mm dia, Ivory colouredPVC conduit of wall thickness not lessthan 2 mm with junction boxes, bends, elbows and all accessories etc as required as per site requirement. Running of conduit, fixing with suitableclamps and nuts in groove / open /shelter | — | — | — | 11,854 | |
| details. | Item Breakup for | — | — | ||
| Cutting of groove in the wall,plastering of surface to the original forc oncealing of the conduit in the wall(Laying and fixing of conduit will bepaid separately) | — | — | — | 4,200 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of 19mm size rigid conduit pipes of 2mm thickness PVC pipe (ISI mark) concealed in wall with all required accessories conforming to IS 9537.3.1983 along with accessories ( bends, elbow, deep junction boxes(3 way, 4 Way) etc | — | — | — | 23,000 | |
| details. | Item Breakup for | — | — | ||
| Supply and laying of 25mm casing and capping of ISI standard with necessary screws (the distance between the screws shall not exceed 0.5 m) including joints bends and all necessary accessories complete. | — | — | — | 32,000 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 25 mm flexible Galvanised steel with PVC coating conduit pipe as per IS 3480 | — | — | — | 23,900 | |
| details. | Item Breakup for | — | — | ||
| Supply and Fixing of BLDC wall-mounted fans of 400 mm, 35 W, equivalent to Model Renesa of Atomberg Make | — | — | — | 17,110 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of Heavy duty BLDC Air Circulator Wall Mouting Fan 600MM Sweep, 1440 RPM, 230V,AC 50Hz with spped regulator, power consumtopn at speed 1: 100 watts, speed 3: 170Watts, rated speed: 1400 rpm, air delivery : 717 CMM with reverse polarity protection, over voltage protection, short circuit protection, blocked blade protection comfirming to IS- 2997/1997 with two years warranty, Make-Bajaj, Usha, Almonard or Crompton Greaves, Airzon, Orient, RR electric. | — | — | — | 1,35,580 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of SMC junction Box of Size 530 x 450 x 175mm of Model No: Sintex GSJB 5345 to fixing of 4-Pole MCCB and termination of cable to extend supplyMake: Sintex, Hensel etc... | — | — | — | 1,21,740 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of 120 Sq.mm Stud Type Power terminal blocks Din rail mounted of Model No. CBB120 of Connect well Make. | — | — | — | 30,281 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of Partition Plate Suitable for 95 sq.mm to 150 sq.mm terminal blocks of Model No.PPCBB1 of Connect well Make. | — | — | — | 7,040 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of junction box suitable for model no.GSJB306-T of size 275mm X135mm X 110mm with 4 nos of connectors and suitable clamps for fixing , Fire retardant -Class FV- 0 as per IS:11731 Part-II or V-0 as per UL-94 Makes :Sintex/Hensel/L&T.(fixing should be required as per instruction of site supervisor). Suitable clamps for fixing (MS Clapms 02 Sets for each Box with necessary bolts and nuts as per site condition for GI channels/poles as per the directions of Site engineer. | — | — | — | 34,000 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 40/50/63A 4P MCB C Curve , 10 KA capacity with necessary connections and all accessores complete. Makes : legrand/L&T/C&S /Siemens/Schnider/ABB/Havells | — | — | — | 1,66,440 | |
| details. | Item Breakup for | — | — | ||
| Supply and installation of DPX3 160 thermal magnetic based release ; Icu = 36K A; 100A 4 Pole MCCB conform to IEC 60947-2 of model no. 4200 95 of Legrand make with extended ROM , spreader links (2 sets), Make: Legrand,ABB,Siemens,Schneider,L&T(D-Shine). | — | — | — | 1,85,000 | |
| details. | Item Breakup for | — | — | ||
| "Supply of Floor Mounted Hot, Cold and Normal Water Dispenser Brand: BLUE STAR (DetailedDescription/Specification as per Product # 1 of GeM Contract No. GEMC-511687728372059 dt.30/05/2023)" | — | — | — | 19,996 | |
| details. | Item Breakup for | — | — | ||
| Supply of Cold Water High Pressure Washer wtth 110-139 bar, 5 m length hose pipe, 500-599 L/h, with pump RPM: 1450 | — | — | — | 32,000 | |
| details. | Item Breakup for | — | — | ||
| Supply erection, testing and comissionin of Maintenance free earthing with all necessary accessories complete according to IS 3043-1987 and as per RDSO spec No: rdso/spec/ps/0109(rev.0)-2008 Amendment'1'. | — | — | — | 42,939 | |
| details. | Item Breakup for | — | — | ||
| Excavation of earth for one pit in any soil and refilling as per Drg. No ETI/OHE/P/7021 and RDSO specification No.RDSO-TI0LKO(PSI@41&47@2020 dt.25.08.2021. | — | — | — | 3,293.3 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of Earth Elecrode as per RDSO Drg No.ETI/OHE/P/ 7021 (MOD.A) or if any latest.Earth electrodes shall be procured from RDSOapproved sources only , List of RDSO approved sources is enclosed (Annexure-RDSO List). | — | — | — | 16,876.6 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of Charcoal | — | — | — | 5,031 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of Salt | — | — | — | 3,479 | |
| details. | Item Breakup for | — | — | ||
| Provision of RCC earthpit hollow box of size300 mm x 300 mm x300mm with 50 mmwall thickness as perDrg. no.SDO/RDSO/E&B/001 byusing M20 Gradeprecast RCC. It includesfixing of earth pits at various locations (All the required men, materialand transportation are to be arranged bycontractor). Inspection by Consignee. | — | — | — | 5,498.7 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of RCC precast slabs with hook to cover Earth pitsof dimensions as shownin IRSEM drg no 19-D6.All the requiredmaterials for this worki.e. stones, cement, ironand sand etc. are to besupplied by contractor.).Inspection by Consignee. | — | — | — | 1,165.5 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of LED HI-Bay 100Watt as per specification attached | — | — | — | 2,95,345.6 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of 70 sqmm stud type power terminal blocks Din rail mounted Model: Connect well CBB70. | — | — | — | 30,600 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of Partition Plate Suitable for 50 sq.mm to 70 sq.mm terminal blocks of Model No.PPCBB of Connect well Make. | — | — | — | 6,424 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of STEEL SCREW END CLAMP FOR DIN35-15 | — | — | — | 5,320 | |
| details. | Item Breakup for | — | — | ||
| Supply and Erection of 16 Sq.mm Standard feed through terminal blocks of Model No. CTS16U of Connect well Make. | — | — | — | 7,110 | |
| details. | Item Breakup for | — | — | ||
| Supply and erection of Din 35 rail 1mtr length of model no:CA701-15-1M of connectwell | — | — | — | 18,300 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of aluminium lugs for cable size of 70 sqmm of model no: 4S-ALS- 556 of dowells Make | — | — | — | 3,300 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of aluminium lugs for cable size of 95 sqmm | — | — | — | 12,000 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 120 sqmm aluminium lugs of model no: 4S-ALS-531 of dowels make | — | — | — | 5,500 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of Cable end termination aluminum lugsfor 16 sqmm XLPE aluminum cable | — | — | — | 2,214 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 6 sqmm ring type copper of model no:RS-7017 of dowels make | — | — | — | 550 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 10 sqmm ring type copper of model no:RS-7120 of dowels make | — | — | — | 750 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing and connecting P-17 Tempra plg and socket IK 08,of 32A, 3P+E+ N -DP of model no.5078 62 of legrand make or equivalent in Hensel/L&T/Havells/ABB/SEIMENS as per IS/IEC 60309-1 (2002) | — | — | — | 2,77,920 | |
| details. | Item Breakup for | — | — | ||
| Supply, running and termination of 3 core 6 sqmm PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 | — | — | — | 38,970 | |
| details. | Item Breakup for | — | — | ||
| Supply, running, Connecting of 4 core 10 Sqmm PVC heavy duty insulated mutlti stranded Copper conductor cable with necessary accessories like cable ties etc as per IS 694 | — | — | — | 86,030 | |
| details. | Item Breakup for | — | — | ||
| Supply & Laying of Hot Dip Galvanized Iron Strip of size 25x6 mm/ 32x6mm/40x6 mm in ground below 0.30 Mtr./ in floor below 0.05 Mtr. from pit to equipment and connection as required and as per direction of site in-charge. | — | — | — | 13,959 | |
| details. | Item Breakup for | — | — | ||
| Supply, laying and connecting of 25x3mm GI Flat. Hot-dip galvanized should be according to IS-2629:1990 & IS4759:1990. The thickness of galvanizing shall not be less than 75 microns It is to be laid & connected from equipment to earth electrode for continuity complete in all respects | — | — | — | 6,600 | |
| details. | Item Breakup for | — | — | ||
| "Design, Fabrication, supply, installing and fixing of 300mm width, 62.5 mm depth, 2mm thick sizes perforated G.Itray (cable Tray) including Horizontal stiffener to avoid sag of tray and vertical bends reducers, tees, crossmembers and other accessories including fixing with suitable G.I. Clamps / G.I. angles / G.I. flats and withnecessary connected hardware etc." | — | — | — | 1,62,200 | |
| details. | Item Breakup for | — | — | ||
| Supply and laying of GI earth continuity wire of 6 SWG for providing earth inter connections to the cables etc. | — | — | — | 3,600 | |
| details. | Item Breakup for | — | — | ||
| Supply, fixing, testing, connecting and commissioning of 1.5 Ton capacity Hi wall split inverter Air conditioner 5 star rated with hermitically sealed Copper Condensor and ISEER > 5.6, R- 32 Refrigerant including all accessories & fixing of Outdoor Mounting Stand etc. with required lenght of the cables and refrigerant pipes between indoor and outdoor units Note: (1) AC unit supplied to railways must match with the BEE Star Rating valid as on the date of supply. (2)The Product must be registered, on the name of Consignee, with OEM, after successful installation | — | — | — | 1,10,356.3 | |
| details. | Item Breakup for | — | — | ||
| Supply, fixing, testing, connecting and commissioning of Wall Mounted Stabilizer, with auto Cut-Off, Overload Protection, Time Delay feature, suitable for 1.5 Ton capacity split Air conditioning unit complete with all accessories etc | — | — | — | 3,500 | |
| details. | Item Breakup for | — | — | ||
| supply and fixing of 16A combined unit with concealed metal box with 4M cover Plate + 16A c curve MCB + 16A Socket + 16A Magnus plug top equiivalent to model no: AA 4 068 of GM make(glossy white) for AC points | — | — | — | 1,348.6 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 16A combined unit with plastic surface box with 3M Cover Plate + 16A MCB + 16A Raised Socket + 16A plug top of model no: AA 3 173 of GM make Make/Brand: Legrand/ C&S/L&T/Indo-Asian/Havells/GM only. | — | — | — | 1,018 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of 350W LED flood light per as per specification attached | — | — | — | 62,700 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of metal flush box-4 module of model no:JIM 04 003 of GM FOURFIVE make with 4 module cover plate(With support frame) of model no:PK SB 04 004 - CASABLANCA of GM make or equavalant modular Legrand/Havells/L&T/Schneider/Anchor make comply with IEC 60669-1 including all accessories complete. | — | — | — | 8,920 | |
| details. | Item Breakup for | — | — | ||
| Supply and fixing of metal flush box-2 module of model no:JM 02 001 of GM FOURFIVE make with 2 module cover plate(With support frame) of model no:PK SB 02 002 - CASABLANCA of GM make or equavalant modular Legrand/Havells/L&T/Schneider/Anchor make comply with IEC 60669-1 including all accessories complete. | — | — | — | 4,020 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Technicalspecifications--9-26.pdf
ATTACHMENT
Scopeofworkforwiring.pdf
ATTACHMENT
CPWDGeneralspecelectricalworks_compressed.pdf CPWD General Specification
ATTACHMENT
CEGE Technical Circular
ATTACHMENT
ListofLikelySuppliers.pdf
ATTACHMENT
GCC Apr 2022 with Correction slips
ATTACHMENT
JPO Digging of cables
ATTACHMENT
EarthingSpecificationMFEandOther.pdf
ATTACHMENT
RITESInspection.pdf
ATTACHMENT
FirepreventionGuideline.pdf
ATTACHMENT
NITIREPSWorks.pdf
ATTACHMENT
CEGETechnicalCircular07-04-2022_compressed.pdf
ATTACHMENT
GCC_April-2022WithCorrectionSlips._compressed.pdf
ATTACHMENT
RlyBd-JPO-DiggingofCables2013-Re-Circulatedin2022-LATEST.pdf
ATTACHMENT
CPWDGeneralspecelectricalworks_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .