GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR / REPLACEMENT OF STREET LIGHT, SECURITY LIGHT IN DOMESTIC AREA AND 33 SU SITE 1A AND 1B AT AF STN JODHPUR
2021_MES_474395_1
8483/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
Exempted
14 Oct 2021
10 Sept 2021
8 Oct 2021
10 Sept 2021
6 Oct 2021
24 Sept 2021
Amount
Supply and fixing in replacement steel tubular swaged poles type 410 SP-55, 11 metres long complete with CI base plate and final including top cover bracket of required size, painting to the complete pole with two coats of aluminium paint , over one coat of primer complete including zebra painting, numbering the poles with paint; including required excavation & earthwork, PCC (1:4:8) in foundation, PCC (1:3:6) in coping, reqd formwork with & including dismantling the old unserviceable steel pole any length by breaking the old PCC foundation and removal of all the debries out side MOD land complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement PVC Junction box, pole mounting type of size 300mm x 200mm x 105mm or nearest size, central with linked door control, for street light including one 6 Amps MCB SP with aluminium bus bar TPN for controlling the Street Lights complete, including mounting the junction box on pole with suitable arrangement with required MS clamp, nuts & bolts complete all as specified & directed by the Engineer-in-Charge.
Supply, Laying, Testing and Commissioning in replacement of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables 16 Sqmm 04 core (heavy duty) 1100 Volts grade with stranded Aluminium conductor complete all as specified by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth for foundation/cable trench/laying of pipe line/taking out pipe etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil to a distance not exceeding 50 metres and deposing where directed at a level not exceeding 1.5 metres above the starting point complete all as specified and directed by Engineer-in-charge.
Supply and filling dry, clean sand in trenches for cushioning of underground cable including punning down complete all as specified and directed. Note:- Only Punned down thickness shall be maesured and paid
Laying only 40 to 50 mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and not less than 50 cm in length retreived from excavation, laid dry abutting each other for under ground protection complete all as specified and directed.
Supply & fixing in replacement LED street light fitting 70 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED street light fitting 90 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement LED Flood Light Fitting 150 Watt with IP 66 protection and impact resistance of IK-07, 230 Volts, made up of pressure die cast aluminium housing with high efficient LED as lighting source, heat resistance toughned glass with frame, potted driver & all connected acessories complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs GI pipe bracket, made out of 40mm dia light grade GI pipe, fabricated into shape and size as required, not less than 1.2 metre long complete with two MS clamps of MS flat iron 40mm x 6mm with bolts, nuts and washer complete all fixed on poles/walls complete all as specified & directed by the Engineer-in-Charge.
Attending day to day street / security light (of any type and make, installed at various locations of DOMESTIC AREA & 33 SU SITE 1A & 1B at AF station jodhpur) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), GI bracket, replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, MCB, MCCB, Contactor etc replacement of straight through joint and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under srl item no.14 to 19 of this BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply only 6 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only electric driver for 50 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 75 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 100 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 150 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified and directed by the Engineer-in-Charge.
Attending day to day complaints of existing 12 m high highmast light (of any type, make and wattage installed at various locations in DOMESTIC AREA & 33 SU SITE 1A & 1B at AF station jodhpur) received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of flexible wire, MH choke, MH/Sodium lamp, ignitor, lamp holder, driver, SPD, PCB, Contactor, MCB, MCCB replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment etc, properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under srl item no.14 to 19 of this BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply & fixing in replacement 80mm bore, brass single headed hydrant valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement RRL HOSE pipe 15 metre long complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement PVC insulated copper cable of 2.5 Sqmm 2 core complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement PVC conduit of 20mm from junction box to GI pole complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Automatic street light switch using NATURE SWITCH for automatic switching of street light based on lux level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (input- output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric proof, termoite proof and FR grade SMC junction box conforming to IP-54 the contactors, MCBs and copper circuit wiring should be enough to take three phase load of 8KW, Contactor Rating 25-32Amps, MCB SP 32Amps, complete all as specified and directed by the Engineer-in-Charge. Make:- Cat part No Swadeep 02EC-8KW3P or equavelent in Legrand / Siemens / L&T .
GANPATI ENTERPRISES
LOKESH ELECTRICAL WORKS CONTRACTOR
Nvimal Engineers and Contractor
Achal Sales
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .