Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.0 Cr+₹98.5 L (47.8%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹3.0 Cr+₹98.5 L (47.8%) | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
23 Aug 2022, 6:00 pmClosed
CWE (AF) Borjhar
HQ CWE (AF) Borjhar Military Engineer Services PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele 0361 2841626
MODERNISATION AND UPGRADATION OF MES INSTALLATIONS (PHASE-I) AT AFS TEZPUR (2ND CALL)
2022_MES_531873_2
CWE(AF)/TEZ/TOKEN-03 OF 2022-23
Open Tender
Construction Works
Item Rate
365 days
Tezpur
Please refer tender documents
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Tezpur
₹2.8 L
Yes
15 Sept 2022
1 Aug 2022
25 Aug 2022
1 Aug 2022
23 Aug 2022
8 Aug 2022
Amount
B/R Works Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering and removing all as directed
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws with neoprene and EPDM washers. complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws .complete all as specified and directed.
M&L PCC 1:2:4 type B-1, using 20 mm graded stone aggregate as in seismetic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in unframed work and removing all as directed
M & L for 2nd class hard wood timber scantling, clean sawn as in frame work, fixed with nails complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat pink primer complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10cm girth or width, not otherwise described and applyng one coats synthetic enamel paint complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutters from the frame) not exceeding 1.5 sqm each complete including removing all as directed.
Supply and fix for PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
Supply and fix for factory made PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and as directed.
S & F butt hinges 75mm long cold rolled medium weight complete all as specified and as directed.
S & F for 150mm long aluminium handles, cast type, anodised complete all as specified and as directed.
S & F in for 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
S & F in anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S & F in for anodized aluminum window with one or more rebates, anodized aluminium window, sliding type shutters, sliding on two way aluminium channel, without sash bars, sliding on separate track, made out of aluminium section weighing 0.55 Kg/RM and necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, fittings such as suitable anodized aluminium locking type handle etc. and of , complete all as specified and as directed.
S & F in 4mm thick sheet glass exc 0.5sqm each pane, complete all as specified and as directed.
Taking down chowkat or frame (without taking off shutter from the frame) exceeding 1.5 and not exceeding 4 sqm complete all as directed.sqm each including removing complete all as directed.
S & F for 2nd class hard wood in plain, solid, straight chowkats and framed, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F Pressed steel frames for doors mild steel sheet of 1.25mm thick with size of frame 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,
S & F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, section-8, cluse 8.24 (a) complete all as specified and as directed.
S & F 35mm thick factory made plain framed, panelled shutter with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S & F butt hinges 100mm long cold rolled medium weight complete all as specified and as directed.
S & F 150mm long mild steel pressed handles, oval type, stove enameled black complete all as specified and as directed.
S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long all as specified and directed by Engineer - in – Charge .
S & F 250mm long mild steel sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S & F for mild steel works as in hold fast and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S & F in repair MS Helical Door springs 300mm long ordinary rat tail pattern including roller and roller palate complete all as specified and as directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples complete all as specified and as directed.
S & F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples or with wooden beading or any other fixing arrangements complete all as specified and as directed.
S & F in repairs vitreous china squatting pan,”Orissa” pattern, size 580mmX440mm, white, with integral foot rests, ‘S’ trap (excluding flushing cistern and flush pipe) and provision of lime concrete bedding including demolition fo existing WC and removal of debris from the site complete all as directed.
S & F in repair 10 litres capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
M & L 15mm bore GI pipe medium grade with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
M & L 20mm bore GI pipe medium grade with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
S & F in repairs 15mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in repair for vitreous china wash basin, white, flat back, size of 550mm x 400mm including cutting for and pinning in ends of bracket or erecting stand and including 32mm dia waste pipe & brackets including waste coupling of size 32/40 of PTMT complete all as specified and as directed.
S & F in repair 15mm stop valve/ angular stop cock fancy type chromium plated alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or union complete all as specified and as directed.
S & F in repair 15mm bore bib taps, chromium plated with CP flange screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S & F in repairs 50mm bore low density poly ethylene pipes (LDPE) of pressure rating 6 Kg/Square cm fixed to walls, ceiling or in floors etc. complete all as specified and as directed.
S & F Swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gms) or union all as specified and directed .
M & L for prepration of old plastered or unplastered external surfaces of walls and applying one coat of cement base paint complete all as specified
S & F in repair for vitreous china urinal flat back, (Half stall type) Vitreous China urinals, bowl type (back to corner wall type), complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
Demoiton of Brickwork built in cement mortar or cement lime mortar etc including removing all as directed
M & L for Brick work with sub class ‘B’ using old size bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified.
M&L for brick work as in half brick thick wall with sub class "B" bricks straight or curved on plan to any radius with old size bricks locaaly available built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete including removing rubbishes off the premises all as directed.
M&L 10 mm thick cement plaster in CM (1:6) on fair faces of brick work incl finished even and fair without using extra cement complete all as specified and directed.
M&L preparation of the newly plastered surfaces and applying two coat of Oil bound distemper over a coat of primer etc all as specified and directed .
M&L 15 mm thick cement plaster in CM (1:4) in two layers (5mm thick mixed with approved water proofing compound @ 2% weight of cement over backing layer of 10 mm thick) on fair faces of brick work incl finished even and fair without using extra cement. complete all as specified and directed.
M&L preparation of the newly plastered surfaces and applying two coat of cement based paint over a coat of primer etc all as specified and directed
Demoliton of (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing all as directed.
M & L for 75mm thick cement concrete type C2 1:3:6 (40 mm graded aggregate) as in plinth protection laid in bays n exc 3 mtr with construction joints filled with a mixture of sand and bitumin including finishing surfaces even and smooth without using extra cement including complete all as directed by Engr in charge.
M&L for prepration of old plastered or unplastered surfaces and applying one coat of oil bound distemper complete all as directed.
Demoliton of (reinforced) Concrete of any description and in any position not otherwise specifically provided for complete and removing all as directed.
M&L for RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) as in slab supported on walls, beams and column in floors, roof landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed. (Note : Reinforcement shall be measured and paid seperately under relevant items)
M&L TMT bar 10 mm and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.
M&L form work to edges of concrete flats sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5cm but not exc 10cm wide for rough finished surfaces of concrete, flat complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L granite tiles/stone 20mm thick machine cut as in floor/slabs etc, bedded and jointed with grey cement slurry and pointed wikth white cement with admixture of pigment to match shade of granite stone including grinding and polishing including screed bed 15mm thick in CM (1:4) complete all as specified and directed.
M&L for Kota Stone slab 18 - 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes . complete all as specified and directed.
M&L for pre-polished Kota stone slab 15 - 18 mm thick in riser of steps, skirting, dado including 10mm thick plaster in CM (1:3) for reciving the tiles and jointed . complete all as sepcified and directed.
M&L coloured glazed ceramic tiles 450mm x 300 mmx 7 mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10mm thick plaster in CM(1:3) on brick work for fixing of tile . complete all as specified and as directed.
M & L non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm (300x300mm) as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed orbedding layer in CM (1:6) for laying floor finishes . complete all as specified and as directed.
M&L for Complete removal of existing treatment, including preparation of plastered or unplastered surfaces of wall, concrete surfaces, and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489: 2004n Alkali & fungal resistance, dirt resistance exterior paint of required shade ( company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior applied @ 0.90 litre/10 Sqm over new surfaces (weather coat ) in any shade or colour as approved.complete all as specified and directed.
Dismantling water tanks and removing to store Exc 500 Ltr & n exc 1000 Ltr complete and removing all as directed.
S & F in repair for 1000 Litres capacity rotational moulded poly ethylene water storage tanks two layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I with & including PVC float valve 20mm bore, tank cover, wash out pipe, overflow pipe, tank nipple,after complete all as specified and as directed.
M&L Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder upto 5 -10 mm depth without damaging existing rebars, carefully removing unsound weak/ loose concrete/ cover & concrete around the rebars upto 10 mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis outside the premises, etc, complete all as specified and directed necessary scaff -folding complete all as specified and directed
M&L Making V groove of 10mm wide and 30mm deep or upto the extend of joint/crack present at site over joint/ crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed by Engineer-In-Charge.The groove shall be cut on the concrete surface along the joint/crack over RCC structure to be repairedcomplete all as specified and directed. Note: Work to be executed by the authorised applicator of manufacturer only.complete all as specified and directed.
M&LSealing of exposed 'V' groove of 10mm wide and 30mm deep with Sikagard 694 F(I) or equivalnt solvent-free, moisture tolerant, thixotropic, two part structural adhesive and epoxy repair mortar cum surface levelling mortar. Note: Work to be executed by the authorised applicator of manufacturers only.complete all as specified and directed.
M&L for Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the joint & crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive SikaDur 31 or equivalent to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
M&L for Grouting injecting two part, low viscosity, moisture insensitive injection-liquid at damp substrate location, based on high strength epoxy resin Sikadur®-53 UF or equivalent by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 500 mPas at +30°C and should comply according to ASTM C 882 and should have below properties. Compressive strength >= 50 N/mm2 (7 days) according to ASTM C 579; Tensile Strength ~ 30 N/mm2 (after 14 days at +30°C cure) (According to ISO 527); Tensile Adhesion Strength >8 N/mm2 (failure in concrete) after 14 days at +30°C cure. Seal the nozzle with Sikagard 694 F (I) or equivalent thixotropic epoxy putty after the refusal of grout material from the nozzle. Note: leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost.
M&L for cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer Sika RustOff 100 or equivalent rust remover with brush on the existing rebar for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and as directed by Engr-in-charge Note: Work to be executed by the authorised applicator of manufacturer only.
M&L Providing and Application of Sika Friazinc R or equivalent as passivator/ Anti corrossion coating to the steel reinforcement shall be applied . The material shall be two component,cement based polymer modified two component coating for corrosion protection.The material shall be prepacked and ready to use. It shall be fully compatible with the reinstatement methods adopted complete all as specified and as directed by Engr-in-charge.This shall include surface preparation and errection of steel porps as required for the application. complete all as specified and directed. Note: Work to be executed by the authorised applicator of manufacturer only.
M&L of two component solvent free epoxy bonding agent Sika Sikadur 32LP or equivalent for bonding old to new concrete . The ready to use epoxy bonding agent shall be applied over old concrete using brush after cleaning of surface of all dust or latiance.The material is supplied as a two part material in preweighed quantities for ready onsite mixing and use. The material shall exhibits the following properties Compressive strength 50 N/mm2 at 7D Flexural strenght 35N/mms at 7 D , Shear strength 10N/mm2 at 7D and Tensile strength 20 N/mm2 and Bond Strength of 10N/mm2.The new concrete shall be placed within the open time as specified by the manufacturer to ensure maximum bonding and application shall be as per the manufacturer instruction , complete all as specified and as directed by Engr-in-charge. Note: Work to be executed by the authorised applicator of manufacturer only.
Rebuilding the section of damaged RCC elements to its original size in thickness of 25mm by hand or spray application by Providing and applying Sika MonoTop®- 122F single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar.
Providing & Applying of SikaTopseal 107 or equivalent inside of the wall & floor of the tank, a two components ready to use polymer modified cementatious coating certified for portable water in three coats with glass fiber mesh of =>45 GSM . The thicknessof coating shall not be less than 1.5mm. (Note:- Scaffolding, debris disposal and enabling items will be paid separately). complete all as specified and directed.
Applying three coats Sikagard67 or equivalent, a water based epoxy coating certified for portable water on all over the concrete surface from inside. The coating shall be applied using roller brush application. complete all as specified and directed.
Anti-Carbonation Protective Coating for Exterior Providing, and applying single component, high build, elastomeric, crack-bridging, resistant to CO2 & SO2 and Chloride ion diffusion, UV resistant, breathable acrylic coating, with elongation at break exceeding 200% Sikagard - 550 W IN applied in two coats (each coat 100 micron DFT) on acrylic based primer at an average total thickness of 200 microns DFT in two coats including acrylic resin based primer Sikagard® 552 IN Primer W as per the recommendation of the manufacturers. Item rate inclusive of all materials, labours, supervision, tools, tackles, transportation, scaffolding/ temporary supports/working platform etc., complete as per specification and as directed.
Repair of column & beam for large section. Providing and erecting steel props (up to full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required and as directed by the Engineer-in-charge. complete all as specified and directed.
M&L Prepration of existing surfaces like chipping of unsound weak / loose concrete/cover of reinforcement and removal of debries to a designated location (upto full height) block to support the structure proisionally during repair work and maintaining them in positioin till required, complete all specified and directed by the Engineer-in-charge.complete all as specified and directed. (Note:- Scaffolding, debris disposal and enabling items will be paid separately).complete all as specified and directed.
M&L Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, diet etc, complete and proving, applying two coats of alkaline rust converting primer Sika RustOff-100 or equivalent with a coverage of 350gm/sqm on the existing rebar and allowing it to react with rust for 6 hrs and forma corroson resistant, insoluable and adherant protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats.complete all as specified and directed.
M&L Providing and application of zinc rich epoxy antocorrosive protective coating for rebar corrosion protection system Sika Friazinc R® or equivalent in 2 coats of 0.4 kg/m2. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/mm2 according to ASTM C 882-78. complete all as specified and directed.
M&L Making V groove of 10mm wide and 30mm deep or upto the extend of crack present at site over crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower as directed by Engineer-In-Charge. complete all as specified and directed. The groove shall be cut on the concrete surface along the crack over beam or column to be repaired. Note: Work to be executed by the authorised applicator of manufacturer only.
M&L Sealing of exposed 'V' groove of 10mm wide and 30mm deep with Sikagard 694 F(I) or equivalnt solvent-free, moisture tolerant, thixotropic, two part structural adhesive and epoxy repair mortar cum surface levelling mortar. Note: Work to be executed by the authorised applicator of manufacturers only.complete all as specified and directed.
M&L for Drilling & fixing 12mm dia up to 50-75 mm long injection packer in structural members at the interval of 300 mm in staggered manner in reinforced conrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive SikaDur 31 or equivalent to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
M&L for Grouting injecting two part, low viscosity, moisture insensitive injection-liquid at damp substrate location, based on high strength epoxy resin Sikadur®-53 UF or equivalent by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 500 mPas at +30°C and should comply according to ASTM C 882 and should have below properties. Compressive strength >= 50 N/mm2 (7 days) according to ASTM C 579; Tensile Strength ~ 30 N/mm2 (after 14 days at +30°C cure) (According to ISO 527); Tensile Adhesion Strength >8 N/mm2 (failure in concrete) after 14 days at +30°C cure. Seal the nozzle with Sikagard 694 F (I) or equivalent thixotropic epoxy putty after the refusal of grout material from the nozzle. Note: leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost.complete all as specified and directed.
Provision of Additional Rebar M&L Providing and fixing additional corrosion resistant hot dip galvanised steel rebar TMT or height grade as per required diameter in various structrural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive Sika AnchorFix - 2+ Tropical or equivalent complete all as specified and directed.
Drilling & Rebaring of 16mm dia x 160mm deep
Concrete Section Buildup with Jacketing of column & beam by microconcrete and High performance structural mortar in small sections. M&L Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required and as per directions of Engineer-in-charge with with Sikadur®-32 LP in consumption of 0.4 kg/m2. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strenghth should be 10 MPa.complete all as specified and directed.
M&L Rebuilding the section of damaged RCC elements to its original size in thickness of 40mm by hand or spray application by Providing and applying Sika MonoTop®-122F single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar.complete all as specified and directed.
M & L for water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete all as specified and directed by the Engineer-in-charge.
M&L Rebuilding the section of damaged RCC elements to its original size or as per consultants recommendation in thickness of 40-100mm by providing and casting with ready to use non shrink, cementitious free flow micro-concrete SikaRep Microcrete-4 or equivalent having compressive strength > 60 N/mm2 (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and supporting formwork, all lead lift, mixing, placing, de-shuttering, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any to satisfaction of Engineer-in-charge and curing. complete all as specified and directed.
Anti-Carbonation Protective Coating M&L Providing, and applying single component, high build, elastomeric, crack-bridging, resistant to CO2 & SO2 and Chloride ion diffusion, UV resistant, breathable acrylic coating, with elongation at break exceeding 200% Sikagard - 550 W IN applied in two coats (each coat 100 micron DFT) on acrylic based primer at an average total thickness of 200 microns DFT in two coats including acrylic resin based primer Sikagard® 552 IN Primer W as per the recommendation of the manufacturers. Item rate inclusive of all materials, labours, supervision, tools, tackles, transportation, scaffolding/ temporary supports/working platform etc., complete as per specification and as directed.
Taking down cement plaster including ,tarfelt from old concrete roof/chajja and cleaning by picking ,sweeping and washing down with water to remove dust etc Brushing neat cement slurry with 3.0Kg of cement per Sqm and M&L for rendering 10mm thick in CM (1:3) on roof slab/chajja finished even and smooth without using extra cement with water proofing compound @ 3% by weight of cement complete all as as specified and directed . Note : water proofing compound shall be measured and paid separately. complete all as specified and directed.
M& L for water proofing treatment with APP based polymeric membrane 3 mm thick (minimum) weighing 3.00 Kg per sqm reinforced with polyster non woven fabric shall be applied over and including one coat of water based bituminous emulsion primer on newly plastered surface @ 0.40 Kg / Sqm duly thermo fused by flame torch all as specified in method of application manual of the manufacturer complete all as specified and as directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3
M&L Cement concrete type B0 (1:2:4) ( using 12.5 mm graded aggregate ) in roof curb, mud stop or roof kerbs ,round or chamfered on edges including demolition of old one complete all as specified and as directed.
Supply only Integral water proofing compound ISI marked.
Disconnecting existing water storage tanks 500 ltrs to 1000 ltrs capacity, setting aside (for lowering if required) for repair,cleaning ,etc and hosting if required reconnecting and refixing in position including cleaning, removing all scale dirt etc form tanks and from mouths of circulating pipe, repalcement old tank nipple, unions, stop cock, tank cover etc complete all as specified and as directed.
S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drill for fixing of steel sheeting or other covering etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guiders) and also fastening and fixing confirming to Fe-410-w E-250 quality A including dismantling of existing gate/board complete all as specified and directed.
M&L for preparation of new steel or iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of old steel surfaces of any description over 10cm girth or width, not otherwise described and applyng one coats synthetic enamel paint complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft/loose soil
M&L Hardcore with broken stone of gauge n exc 63mm, deposited, spread and levelled in layers n exc, deposited, spread and levelled in layers n exc 15cm thick, watered and rolled / rammed to a true surface.
M&L for 100mm thick plain cement concrete (1:4:8) type D2 using 40mm graded aggregates as in path, hard standing complete all as specified and directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B1 using 20mm graded aggregates as in path, hard standing complete all as specified and directed.
M&L Sand filling under under interlocking tiles including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver blocks of any shape and size confroming to IS15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as directed.
Dismantling of Chain link fencing, wire mesh of any type and in any position by unscrewing nuts fillets, clamps etc. complete including removing all as directed.
Dismantling of galvanised mild steel two strand barbed wire from all existing mild steel or RCC fencing post etc. complete including removing all as directed.
Dismantling security post or struts ( mild steel or RCC) of any section, including taking out embedded in concrete portion and making good disturbed ground complete all as specified and as directed.
Supply and fix Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
Supply only Chain link MS galvanised fencing, any size or type etc complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire etc complete all as specified and directed. Note :- (a) Supply of Galvanized steel wire chain link fecncing, Mild steel round bars, Mild steel flat, Nuts, Bolts & Washers will be measured and paid separately under relevent items.
S & F for galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2.00 mm dia, barbs at 75 mm spacings and straining, tightening and fixing to MS nibs embedded in pre-cast RCC fencing post or angle iron post, struts, etc. securing and tying at crossing with galvanished mild steel wire complete all as specified and as directed. Note :- Each line wire to be measured separately.
E/M WORKS Excavating in trenches not exc. 1.50M wide and not exc. 1.50M in depth for foundation laying of pipeline, cable etc and getting out in soft /loose soil complete all as specified and directed.
Returning filling in soft/loose soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 Cms complete all as specified and directed.
Removing excavated soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as directed.
Supply, laying, connecting and testing 150mm bore, ductile iron pipes socket and spigot class K-9 suitable for including rubber gasket joint in standard working length conforming to IS 8329 laid in trenches complete all as specified and directed.
M&L Cast iron sluice valve, size 150mm dia, heavy duty (PN-1.6) long body with flanged ends, brass spindle, both end flanged with iron wheel head conforming to IS including jointing and jointing materials, nuts, bolts, rubber gasket, and washers etc complete all as specified and directed.
Supply and fix 100mm bore cast iron non return valve with bypass arrangements heavy duty (IS-5312), class PN-1.6, drilled holes for bolt, including necessary rubber gasket joint with nut and bolts complete all as specified and directed.
Supply and fixt foot valve with G M working parts as per IS-4038 of size 80mm dia including necessary rubber gasket joint complete with nuts and bolts all as specified and directed.
Cast Iron Air release Valves with two air Outlets, 150 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed.
Supply, install,testing and commissioning pumping set centrifugal, electric driven motor 15 WHP, 3 phase, 415 volts, 4"x3" suction and delivery, capacity 550 LPM 50 mtr head (incl angle iron base & PCC foundation), and fixing of fully automatic Star Delta Starter of 15 HP capacity with three phase, 415 volts relay range ground mounted on 50MM x 6mm flat iron clamp duly grouted in wall minimum clearance 2" from wall including connections with lugs testing coplete all as specified and directed. Make : Kirloskar /Beacon or equivellent
Supply and fix for 100mm bore GI tubing medium grade laid in trenches with all fittings such as bend, unions, tee, elbow, reducer including testing complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not ness than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth laid surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, connected to earth lead GI strip 32 x 6mm dia by means of bolts, nuts, check-nuts and wahsers of galvanized iron pipe light grade with funnel and wire mesh complete including excavation and earth work, RCC chamber and cover in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate etc all as specified and shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completionand directed.
Material and labour for valve chamber 900 x 900 x 900 mm (internal ) withn brick masonary valve chamber, PCC foundation, plastering and necessary excavation and earth work in hard/ dense soil, MS sheet cover 3.15 mm thickness along with angle iron frame of size 40 x 40 x 6mm with locking arrangement with necessary fixing matrials like hinges, nut/bolts etc and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc all as specified.
Supplying laying and testing PVC insulated and sheathed flat cable with stranded copper conductor cable of size 3 core 10 Sqmm 1100 volts grade complete all as specified and as directed .
M&L for Chlorine/chemical dosing system CDS series consisting of FRP solution preparation cumsetting tank of capacity 200ltrs. with lid,port hole,inlet/outlet/drain commection, level gauge etc and fitted with speed reducing motor and SS-316 agitator. Make: RMCO, Model: CDS-200
S&F mild steel work as in joist channel, angles or tee sections plates fixed independently with or without connecting plates etc out to required length and shape including two coats of synthetic enamel paint over one coat of red-oxide primer all as directed (Work for lifting assy of Submersible Pump Set).
Supply and fixing Chain pully block, triple spur gear, 2 ton capacity, manually operated completed with hooks high tensile forged steel confirming to IS : 3815 and load confirming to IS: 6216 and hand chain to IS: 2429 (Part-I) complete and fixing tripod made out of 3 Nos MS ERW, 80mm bore (4 mtr, long) each pipe coupled with heavy grade bolt and nut which can with stand 2 Ton load including 3 Nos MS plate 10mm thick of size 300mmx300mm duly welded at the bottom of pipe complete all as specified and as directed.
Supply and fixing preassure gauge in pipe line 100 mm dia ,0 to 14 Kg / cm2 including all necessary fittings complete all as specified and as directed .
Dismantling of ACSR Conductor, Line Separator, Service feeder or distribution span from the existing LT overhaed lines etc. complete and removing all as directed.
Dismantling and taking down insulators any type and size from the existing LT overhaed lines, complete and removing all as directed.
Dismantling and taking down cross arms or MS Chanel or angle iron etc. from the existing LT line, complete and removing all as directed.
Supply, installation, testing & commissioning of 50 KVA 3 phase oil cooled servo controlled voltage stabilizer microcontroller based with 1st fill of oil, auto/manual reset with time delay programmable, three phase AC input frequency 47 Hz to 53 Hz, oil cooled on load stepless indoor type and designed for input variation between 300 V to 480 V with output voltage stabilised at 415 V with accuracy +/- 1% and speed of correction 60-70 volt per second with manual bypass & input MCCB rolling contact brentford type, suitable for balanced/unbalanced load including filling of transformer oil confirming to IS-335 complete all as specified and directed.
Supply, installation, commissioning and testing of 11 KV, 3 Phase, 3 Wire 50 Hz, outdoor type 630 amp, 350 mva with 01 incomming and 01 outgoing facility VCB Panels boards horizontal draw out horizontal isolation floor mounting manually operated panel with 230 Volt motor mechanism & 24V DC shunt/close coil and other fittings & accessories. 26.3 KA breaking capacity for 3 Sec, totally enclosed with extended copper busbar of 630 Amps for each phase metal clade indoor extensible type flush front, horizontal isolation horizontal draw out type with electrical and mechanical interlock and automatic safety shutter gare including pad locking arrangement, isolation plug assemble with Vacuum interrupters with each pole individually encapsulated by epoxy insulations to make it dust proof and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB) manual and automatic motor charge independent closing/tripping spring, trip free operating mechanism with closing and tripping push bottems and mechanical breaker interconnected with HT sleeve, copper bus bur of 630 Amps including all prospection, indication, operation, monitoring and control and accessories as per specification.Closing and tripping coil of VCB should be of continuous rating to achieve minimum failure 11 KV Epoxy Resin Cast Current Transformer CT Ratio : 100-50/5+5A Core I CL 1.0 with 15 VA burden for metering, Core II CL 5P 10 with 15 VA burden for Protection.
Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
M/L brick sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specefied and directed.
M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C-1 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site.
S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
S&F Galvanised Iron Pipe 32mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 Core. (Note : Item is Considered for Voltage Stabilizer Connection)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 Core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 Core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 Core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 Core
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. ( GI strip upto 7.5m including testing consider in this item).
M&L galvanised iron 32×6mm strip as earthing lead, complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm.
S&F cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 sqmm to 95 sqmm
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
Taking down/out unserviceable or serviceable HT UG Cables of nominal Cross Sectional Area 70/95 sqmm 3 core and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Relaying of existing cable, GI Pipes, etc. complete all as specified and as directed. (NOTE FOR ITEM No 160 and 161 : (This item is taken for rerouting of existing HT/LT CABLE)
Taking down/out unserviceable or serviceable LT UG Cables of any size and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Relaying of existing cable, GI Pipes, etc. complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded aggregate) as in foundation, filling and mass concrete, platform etc including necessary forrmwork complete all as specified and as directed. Note :- Item shall be used for PCC footpath/ hard standing in the outdoor type sub-station complex / near 4 pole structure.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Supply only Electric rubber hand gloves 11 KV
Supply only Electric rubber hand gloves 33 KV
S&F Cable Junction Box 155X210X92mm in size, made out of thermoplastic sheet having IP 66/69 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium strip clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed. Make : Cat No. KF 1616 B of HENSEL or equivalent model in SPELSBERG/RITTAL/SINTEX.
S&F Mild Steel Chequered Plates confirming to Gde Fe 410 - O or Fe 310 - O (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, square cut to required size for Cable Duct Cover, complete all as specified and as directed.
S & F Structural steel work of angle, confirming to Gde Fe 410 - O or Fe 310 - O fixed independently as in fencing, brackets, for duct etc complete all as specified and directed.
Supplying and laying PVC insulated and FR PVC sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 electric control cable with copper conductor, 1100 volts grade, cross sectional area 1.50 sqmm 3 core including taking down U/S cable, complete all as specified and directed. (MAKE – Finolex/Havells/KDK/Harsh)
M&L Straight Through (Heat shrink) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area exc. 25 Sqmm but not exc. 50 Sqmm, 3.5/4 Core and Testing complete all as specified and as directed.
Repairing of electric pole coping by dismantling of PCC , welding of electric pole by using three No. angle of 500 mm length and size 40mmx5 mm around the pole, after that painting of red oxide with single coat of black synthetic enamel paint and making the coping of size 450 mm x 450 mm x 450 mm with suitable slop Complete all as specifed and directed. Note :- (i) PCC for Coping shall be consider seperately. (ii) Welding , angle cost, and painting shall be included in quoted rate.
Flint India
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .